1.
Comput Biol Med ; 149: 105945, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35994934

RESUMO

Burn scar treatment is a difficult subject to address since the improper therapy can have a significant impact on people's quality of life. The evaluation of medical therapy over time should be based on objective measurement of the severity of burn scars and their progression. Unfortunately, most clinical assessments of scars are still reliant on physicians' subjective exams of patients. A profitable method to overcome the limitations of subjective assessment could be to leverage 3D scanning technologies. These could be used to retrieve the surface topology of burns. Accordingly, the goal of this study is to provide an objective approach for analysing the surface topology of burn scars using 3D scanning and roughness-based evaluation. In particular, two types of ISO-compliant profile and surface filters (Gaussian and Wavelet) derived from the analysis of roughness in the mechanical sector are implemented to discriminate form from roughness of scars. Once retrieved, the roughness surface is processed to derive a set of statistical parameters describing the scar surface topology. Three case studies were used to derive these parameters (a synthetic surface, an ostrich-skin surface and a set of scars). After the surface's roughness was determined, a comparison between healthy and unhealthy skin could be established. The devised methods prove their effectiveness in correctly retrieving the main surface characteristics of a burn scar. Therefore, by using the proposed method it will be possible to evaluate the effectiveness of medical therapy by comparing the healthy and scarred skin of a single subject.


Assuntos
Queimaduras , Cicatriz , Queimaduras/diagnóstico por imagem , Queimaduras/terapia , Cicatriz/diagnóstico por imagem , Humanos , Qualidade de Vida , Pele/diagnóstico por imagem
2.
Sensors (Basel) ; 21(22)2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34833847

RESUMO

RGB-D cameras are employed in several research fields and application scenarios. Choosing the most appropriate sensor has been made more difficult by the increasing offer of available products. Due to the novelty of RGB-D technologies, there was a lack of tools to measure and compare performances of this type of sensor from a metrological perspective. The recent ISO 10360-13:2021 represents the most advanced international standard regulating metrological characterization of coordinate measuring systems. Part 13, specifically, considers 3D optical sensors. This paper applies the methodology of ISO 10360-13 for the characterization and comparison of three RGB-D cameras produced by Intel® RealSense™ (D415, D455, L515) in the close range (100-1500 mm). ISO 10360-13 procedures, which focus on metrological performances, are integrated with additional tests to evaluate systematic errors (acquisition of flat objects, 3D reconstruction of objects). The present paper proposes an off-the-shelf comparison which considers the performance of the sensors throughout their acquisition volume. Results have exposed the strengths and weaknesses of each device. The D415 device showed better reconstruction quality on tests strictly related to the short range. The L515 device performed better on systematic depth errors; finally, the D455 device achieved better results on tests related to the standard.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...