Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eye (Lond) ; 37(14): 3009-3014, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36928228

RESUMO

OBJECTIVE: To investigate the relationship between cystoid macular oedema (CMO) measured in preterm infants using hand-held spectral domain optical coherence tomography (HH SD-OCT), with gestational age at birth (GA), birthweight (BW), diagnosis of retinopathy of prematurity (ROP) and the presence or absence of the external limiting membrane (ELM). METHODS: We conducted a prospective mixed cross-sectional/longitudinal observational study of 112 participants (23 to 36 weeks GA; n = 25 with, and n = 87 without, CMO). Retinal images were acquired using 344 HH SD-OCT (n = 66 with and n = 278 without, CMO) between 31 to 44 weeks postmenstrual age (PMA). CMO type ('fovea' and 'dome') was measured using thickness, width, area and peak. RESULTS: CMO was observed in 22.9% of preterm infants, and 19.2% of images. The mean values for  thickness, width, area and peak of 'dome' CMO were 128.47 µm (SD +/- 34.23), 3624.45 µm (SD +/- 1323.03), 0.49 mm2 (SD +/- 0.28) and 279.81 µm (SD +/- 13.57) respectively. The mean values for  thickness, width, area and peak of 'fovea' CMO were 64.37 µm (SD +/- 17.11), 2226.28 µm (SD +/- 1123.82), 0.16 mm2 (SD +/- 0.11) and 95.03 µm (SD +/- 26.99) respectively. Thickness, area width and peak were significantly greater for 'dome CMO compared with 'fovea' CMO (P < 0.0001 for thickness, area and peak; P < 0.01 for width). Area and width significantly decreased with PMA for 'dome' and 'fovea' CMO (p = 0.0028; p < 0.001 respectively). No association was found between the presence of ROP and the detection of CMO or detection of CMO with absence of ELM. CONCLUSIONS: HH -OCT in preterm infants demonstrates that the severity of CMO appearance improves each week for both fovea and dome CMO.


Assuntos
Edema Macular , Retinopatia da Prematuridade , Lactente , Humanos , Recém-Nascido , Edema Macular/diagnóstico por imagem , Recém-Nascido Prematuro , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Estudos Transversais , Retinopatia da Prematuridade/diagnóstico
3.
Br J Ophthalmol ; 94(8): 1007-11, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19955200

RESUMO

BACKGROUND/AIMS: Little is known about the effectiveness of occlusion therapy in hospital settings. A retrospective analysis was conducted to assess modalities, outcome and hospital costs of children treated for amblyopia with patching in a UK clinic. METHODS: Notes of 322 children with amblyopia discharged after occlusion treatment were selected consecutively and reviewed. Data collated included age at presentation, amblyopia type, visual acuity (VA; before/after occlusion and at discharge), number of prescribed hours of occlusion, duration of patching treatment, number of glasses prescribed and number of visits attended or failed to attend. Hospital treatment costs were estimated. RESULTS: Mixed amblyopes were prescribed the longest amount of patching (mean 2815 h over 23 months) followed by strabismic (1984 h) and anisometropic (1238 h) amblyopes. 319 amblyopes received glasses and five atropine treatment. The percentage of patients reaching VA of 6/12 was best in the anisometropic and strabismic groups (>75%) and worse in mixed amblyopia (64%). Average hospital costs were estimated at pound1365. CONCLUSION: Although the mean duration of treatment was long, involving many hospital visits, the visual outcome was variable, unsatisfactory (<6/9) and more expensive than necessary. As compliance has been identified as a major problem methods to improve amblyopia treatment are needed, possibly by using educational/motivational intervention.


Assuntos
Ambliopia/terapia , Privação Sensorial , Ambliopia/economia , Ambliopia/fisiopatologia , Criança , Pré-Escolar , Óculos/estatística & dados numéricos , Custos Hospitalares/estatística & dados numéricos , Humanos , Lactente , Auditoria Médica , Ambulatório Hospitalar/economia , Cooperação do Paciente , Estudos Retrospectivos , Medicina Estatal/economia , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Acuidade Visual
4.
Strabismus ; 16(1): 29-32, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18306120

RESUMO

INTRODUCTION: Smoking cannabis has been described to reduce acquired pendular nystagmus in MS, but its effect on congenital nystagmus is not known. PURPOSE: To report the effect of smoking cannabis in a case of congenital nystagmus. METHODS: A 19-year-old male with congenital horizontal nystagmus presented to the clinic after smoking 10 mg of cannabis. He claimed that the main reason for smoking cannabis was to improve his vision. At the next clinic appointment, he had not smoked cannabis for 3weeks. Full ophthalmologic examination and eye movement recordings were performed at each visit. RESULTS: Visual acuity improved by 3 logMar lines in the left eye and by 2 logMar lines in the right eye after smoking cannabis. The nystagmus intensities were reduced by 30% in primary position and 44%, 11%, 10% and 40% at 20-degree eccentricity to the right, left, elevation and depression, respectively, after smoking cannabis. CONCLUSION: Cannabis may be beneficial in the treatment of congenital idiopathic nystagmus (CIN). Further research to clarify the safety and efficacy of cannabis in patients with CIN, administered for example by capsules or spray, would be important.


Assuntos
Fumar Maconha , Nistagmo Congênito/tratamento farmacológico , Adulto , Movimentos Oculares , Humanos , Masculino , Acuidade Visual
6.
Br J Ophthalmol ; 90(7): 839-43, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16556621

RESUMO

BACKGROUND: Pharmacological treatment has been successful in some forms of acquired neurological nystagmus. However, drugs are not known to be effective in idiopathic infantile nystagmus or nystagmus associated with ocular diseases. METHODS: The authors retrospectively analysed Snellen visual acuity (VA), subjective visual function, and eye movement recordings of 23 patients with nystagmus (13 secondary to multiple sclerosis, three associated with other neurological diseases, two idiopathic infantile, and five with associated ocular diseases) treated with gabapentin or memantine. RESULTS: With gabapentin, 10 of 13 patients with nystagmus secondary to multiple sclerosis (MS) showed some improvement. Memantine improved the VA in all three patients with MS who did not improve on gabapentin. There was no change of nystagmus in other neurological disorders. Patients with congenital nystagmus showed reduction of nystagmus and their VA changes depended on the ocular pathology. CONCLUSION: Gabapentin and memantine may be effective in acquired nystagmus secondary to MS. To the authors' knowledge this is the first series of patients showing that gabapentin is effective in improving nystagmus in congenital nystagmus/nystagmus associated with ocular pathology. Memantine may be useful as an alternative drug in treating patients with nystagmus.


Assuntos
Aminas/uso terapêutico , Ácidos Cicloexanocarboxílicos/uso terapêutico , Antagonistas de Aminoácidos Excitatórios/uso terapêutico , Memantina/uso terapêutico , Nistagmo Congênito/tratamento farmacológico , Nistagmo Patológico/tratamento farmacológico , Ácido gama-Aminobutírico/uso terapêutico , Adolescente , Adulto , Idoso , Gabapentina , Humanos , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Esclerose Múltipla/fisiopatologia , Nistagmo Congênito/fisiopatologia , Nistagmo Patológico/etiologia , Nistagmo Patológico/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento , Testes Visuais
9.
Br J Ophthalmol ; 88(6): 796-802, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15148215

RESUMO

BACKGROUND/AIMS: Few studies have investigated normal response characteristics of torsional optokinetic nystagmus (tOKN). The authors have investigated the effect of stimulus velocity and central/peripheral stimulation on tOKN. METHODS: Torsional OKN was elicited using a sinusoidal grating rotating at velocities of 3 degrees /s to 1000 degrees /s in clockwise and anticlockwise directions. To investigate the effect of central stimulation, stimulus size was varied from 2.86 degrees to 50.8 degrees. An artificial scotoma placed over a 50.8 degrees stimulus was varied from 2.86 degrees to 43.2 degrees to investigate peripheral stimulation. Eight subjects participated in each experiment and torsional eye movements were recorded using video-oculography. The mean slow phase velocity (MSPV) and gain were calculated. RESULTS: The maximum gain occurred in response to 8 degrees /s stimulation. The MSPV increased up to a stimulus velocity of 200 degrees /s achieving a maximum of 3 degrees /s in both directions. MSPV was linearly correlated with the log of stimulus velocity. The smallest field size, rotating at 40 degrees /s, evoked 10% of the gain elicited by the largest display. When the most peripheral stimulus was used, the gain was maintained at 50% of the gain evoked when the full display was used. CONCLUSIONS: A wide range of stimulus velocities can elicit tOKN and peripheral field stimulation contributes significantly to its response.


Assuntos
Nistagmo Optocinético/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anormalidade Torcional , Gravação em Vídeo , Testes Visuais
10.
J Neurosci Methods ; 85(2): 153-9, 1998 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-9874151

RESUMO

This report describes the set-up and evaluation of a novel system for producing precise finger movements, for tests of movement perception. The specifications were to construct a system using commercially available components that were easy to use but which offered both flexibility and also high precision control. The system was constructed around an industrial AC induction motor with an optical encoder, controlled by an AC servo digital control module that could be programmed using a simple, high-level language. This set-up fulfilled the requirements regarding position and velocity control for a range of movements and also the facility for the subject to move the joint voluntarily while still attached to the motor. However a number of problems were encountered, the most serious being the level of vibration and the inability to vary the torque during movements. The vibration was reduced to the point where it did not affect the subject, by the introduction of mechanical dampening using an anti-vibration coupling and a pneumatic splint. The torque control could not be modified during rotation and so the system could only be operated using constant torque for any given movement.


Assuntos
Estimulação Elétrica/instrumentação , Articulações dos Dedos/fisiologia , Movimento/fisiologia , Computadores , Desenho de Equipamento , Humanos , Rotação , Torque , Vibração , Volição
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...