1.
Ear Hear ; 25(3): 230-41, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15179114

RESUMO

OBJECTIVE: The aim of this study was to investigate the benefits of the preprocessing scheme "Adaptive Dynamic Range Optimization" (ADRO) in children using Nucleus cochlear implants. Previous research with adults indicates improved speech perception in quiet and improved sound quality in everyday listening environments with the ADRO scheme. DESIGN: Children were given 4 wk of take-home experience with ADRO, with a minimum of 2 wk in which ADRO was "locked-in." After 1 wk of ADRO use and again after 4 wk of ADRO use, Bench-Kowal-Bamford (BKB) sentence perception in quiet at a low input level of 50 dB SPL (unweighted root mean square) and sentence perception in noise were compared with the child's everyday (Standard) program and the ADRO program. Children also rated the loudness of a variety of environmental sounds and indicated which program provided the best hearing in a variety of everyday listening situations. RESULTS: On average, BKB sentence perception in quiet at 50 dB SPL was significantly better with the ADRO program compared with the Standard program. The group mean improvement was 8.60%. Similarly, group mean scores for BKB sentences presented at 65 dB SPL in multitalker babble were significantly higher with the ADRO program (an improvement of 6.87%). The ADRO program was the preferred program in 46% of the listening situations, whereas the Standard program was preferred in 26% of situations. Everyday sounds were not unacceptably loud with ADRO. CONCLUSIONS: There was an ADRO benefit for this group of children in quiet and in noise. These findings suggest that young children would benefit from the ADRO programming option being locked in along with other processor settings in the SPrint processor once their MAP levels have stabilized. Some older children and teenagers may choose to use ADRO selectively for specific listening situations.


Assuntos
Implantes Cocleares , Perda Auditiva/terapia , Percepção da Fala , Estimulação Acústica/instrumentação , Adolescente , Adulto , Análise de Variância , Criança , Humanos , Satisfação do Paciente , Ajuste de Prótese/métodos , Análise de Regressão , Medida da Produção da Fala , Inquéritos e Questionários , Resultado do Tratamento
2.
Ear Hear ; 23(1 Suppl): 18S-27S, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11885571

RESUMO

OBJECTIVE: The main objective of this study was to assess whether speech perception and speech production in children using the Nucleus 24 cochlear implant system improved with a change in speech processing strategy from the SPEAK to the Advanced Combination Encoder (ACE) strategy. The major difference between the two strategies is that ACE uses a higher stimulation rate (in this study the stimulation rate was 900 Hz per channel) compared with the SPEAK strategy, where the stimulation rate is 250 Hz per channel. Information also was obtained regarding the adjustment period after conversion to the ACE strategy. DESIGN: An ABA experimental design was used where scores were initially obtained using the SPEAK strategy' (in the initial A time interval), and subsequently performance was assessed using the ACE strategy (B time interval) and then again with the SPEAK strategy (second A time interval). The duration of the B interval was 10 wk, and the duration for the second A interval was 4 wk. Seven children aged between 9 and 16 yr who had at least 6 mo experience with the SPEAK strategy participated. Open-set monosyllabic CNC word perception in quiet and Speech Intelligibility Test sentence perception in noise was evaluated at the end of each of the time intervals. Word perception was also monitored at fortnightly intervals during the B time interval. Speech production was assessed at the end of the initial A time interval and at the end of the B time interval. RESULTS: Mean word and phoneme scores for open-set words in quiet for the group of seven children were significantly higher with the ACE strategy as compared with the SPEAK strategy scores obtained in both of the A time intervals. For sentences in noise, mean scores using the ACE strategy as well as the SPEAK strategy at the second A evaluation point were significantly higher than the scores using the SPEAK strategy measured at the first A time interval. This suggests that learning effects may have influenced outcomes. For some subjects, an initial decrease in scores was found during the initial 2-wk period after fitting the ACE strategy; however, scores subsequently were found to be similar to or higher than those when using the initial SPEAK strategy. Analysis of speech production assessments showed an improvement in the medial consonant scores after using the ACE strategy. CONCLUSIONS: This study demonstrated that some children were able to benefit from the additional information provided by the ACE strategy as compared with the SPEAK strategy. However, the differences in overall performance between the two strategies appear to be relatively small.


Assuntos
Estimulação Acústica/instrumentação , Implante Coclear , Surdez/reabilitação , Percepção da Fala/fisiologia , Adolescente , Criança , Desenho de Equipamento , Feminino , Humanos , Masculino , Medida da Produção da Fala