Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Abdom Radiol (NY) ; 49(2): 414-424, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37853236

RESUMO

OBJECTIVES: To investigate the clinical value of pre-treatment quantitative contrast-enhanced ultrasound (CEUS) in assessing the response of colorectal liver metastases (CRLM) to chemotherapy plus targeted therapy. METHODS: This study retrospectively enrolled 50 CRLM patients from the Zhongshan Hospital, Fudan University as the training cohort and 14 patients from Shanghai Tenth People's Hospital as the testing cohort. Patients underwent the CEUS examination before receiving chemotherapy (CAPOX, FOLFOX, FOLFIRI, or FOLFOXIRI) plus targeted therapy (Bevacizumab or Cetuximab). The therapy response was determined according to Response Evaluation Criteria in Solid Tumors version 1.1 based on pre-treatment CT and 3-month follow-up CT after therapy. Dynamic analysis was performed by VueBox® software. Time-intensity curves with quantitative perfusion parameters were obtained. In the training cohort, univariable and multivariable logistic regression analyses were used to develop the predictive model of therapy response. The predictive performance of the developed model was validated in the testing cohort. RESULTS: After the logistic regression analyses, the peak enhancement (PE) (odds ratio = 1.640; 95% confidence intervals [CI] 1.022-2.633) and time to peak (TTP) (odds ratio = 0.495; 95% CI 0.246-0.996) were determined as independent predictive factors. PE and TTP generated from VueBox® were not affected by ultrasound instruments and contrast agent dosage in therapy response evaluation (P > 0.05). The logistic regression model achieved satisfactory prediction performance (area under the curve: 0.923 in the training cohort and 0.854 in the testing cohort). CONCLUSION: CEUS with dynamic quantitative perfusion analysis, which presents high consistency, has potential practical value in predicting the response of CRLM to chemotherapy plus targeted therapy.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Estudos Retrospectivos , China , Bevacizumab/uso terapêutico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/secundário
2.
Ultrasound Med Biol ; 50(1): 142-149, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37852872

RESUMO

OBJECTIVE: The aim of the work described here was to evaluate the role of contrast-enhanced ultrasound (CEUS) in response evaluation for unresectable advanced hepatocellular carcinoma (HCC) treated with tyrosine kinase inhibitors (TKIs) plus anti-programmed cell death protein-1 (PD-1) antibody therapy. METHODS: A prospective cohort of consecutive patients with HCC who received combined TKI/anti-PD-1 antibody treatment for unresectable HCC between January 2022 and October 2022 was included in this study. The patients underwent unenhanced ultrasound (US) and CEUS examinations before treatment and at follow-up. Changes in the largest diameters of the target tumor on unenhanced US and the largest diameters of the enhancing target tumors on CEUS were evaluated. Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1 with unenhanced US and magnetic resonance imaging/computed tomography (MRI/CT) and modified RECIST (mRECIST) with CEUS and CEMRI/CT were used to assess treatment response. RESULTS: A total of 24 HCC patients (23 men and 1 woman; mean age: 56.5 ± 8.5 y; Barcelona Clinic Liver Cancer stage C, 62.5%; 29 intrahepatic target tumors) were studied. Calculations of degree of necrosis in the target tumors revealed no significant differences between CEUS and CEMRI/CT (44.5 ± 36.2% vs. 45.3 ± 36.8%, p = 0.862). As for the differentiation of responders from non-responders, the agreement between RECIST version 1.1 of unenhanced US and mRECIST-CEUS was poor (κ coefficient = 0.233). Meanwhile, there was a high degree of concordance between mRECIST-CEUS and mRECIST-CEMRI/CT (κ coefficient = 0.812). CONCLUSION: CEUS proved to be superior to baseline US and is comparable to CEMRI/CT in defining treatment outcome for combined TKI/anti-PD-1 antibody therapy.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/tratamento farmacológico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Meios de Contraste
3.
Diagnostics (Basel) ; 13(3)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36766467

RESUMO

OBJECTIVE: Ultrasound (US) plays an important role in the diagnosis and management of breast diseases; however, effective breast US screening is lacking in rural and remote areas. To alleviate this issue, we prospectively evaluated the clinical availability of 5G-based telerobotic US technology for breast examinations in rural and remote areas. METHODS: Between September 2020 and March 2021, 63 patients underwent conventional and telerobotic US examinations in a rural island (Scenario A), while 20 patients underwent telerobotic US examination in a mobile car located in a remote county (Scenario B) in May 2021. The safety, duration, US image quality, consistency, and acceptability of the 5G-based telerobotic US were assessed. RESULTS: In Scenario A, the average duration of the telerobotic US procedure was longer than that of conventional US (10.3 ± 3.3 min vs. 7.6 ± 3.0 min, p = 0.017), but their average imaging scores were similar (4.86 vs. 4.90, p = 0.159). Two cases of gynecomastia, one of lactation mastitis, and one of postoperative breast effusion were diagnosed and 32 nodules were detected using the two US methods. There was good interobserver agreement between the US features and BI-RADS categories of the identical nodules (ICC = 0.795-1.000). In Scenario B, breast nodules were detected in 65% of the patients using telerobotic US. Its average duration was 10.1 ± 2.3 min, and the average imaging score was 4.85. Overall, 90.4% of the patients were willing to choose telerobotic US in the future, and tele-sonologists were satisfied with 85.5% of the examinations. CONCLUSION: The 5G-based telerobotic US system is feasible for providing effective breast examinations in rural and remote areas.

4.
Clin Hemorheol Microcirc ; 82(1): 53-62, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35599476

RESUMO

BACKGROUND: Two-dimensional (2D) - shear wave elastography (SWE) has made promising advances in the diagnostic of breast lesions. However, few studies have assessed whether the diagnostic effectiveness of different platforms employing 2D-SWE is equal or different. OBJECTIVE: To compare the diagnostic effectiveness of 2D-SWE techniques from two different systems in differentiating malignant breast lesions from benign ones. METHODS: A total of 84 breast lesions were retrospectively analyzed by experienced radiologists using 2D-SWE on two ultrasound systems, i.e. system-1 (LOGIQ E9 system, GE Healthcare, Wauwatosa, WI, USA), and system-2 (Aixplorer US system, SuperSonic Imagine, Aix-en-Provence, France). Qualitative and quantitative parameters including color sign, the maximum elasticity modulus values (E-max), the mean elasticity modulus values (E-mean) and standard deviation (E-sd) of elasticity modulus values in two 2D-SWE systems were analyzed. The diagnostic performance between system-1 and system-2 were evaluated in terms of the areas under the receiver operating characteristic curves (AUROCs). RESULTS: Among the 84 lesions in this study, 66 (78.6%) were benign and 18 (21.4%) were malignant. E-max in system-1 showed the best diagnostic performance with a cut-off value of 174.5 kPa with the associated sensitivity and specificity of 100.0% and 80.3% respectively. Meanwhile, E-sd in system-2 displayed the best diagnostic performance with a cut-off value of 12.7 kPa, with the associated sensitivity and specificity of 94.4% and 80.3% respectively. The diagnostic performance of the two 2D-SWE systems was not statistically different according to receiver operating characteristic curve (ROC) analysis of E-max, E-mean, and E-sd. CONCLUSION: For identifying breast lesions, system-1 and system-2 appear to be similar in diagnostic performance. However, different cut-off values for different parameters might be selected to obtain the best diagnostic performance for the two 2D-SWE systems.


Assuntos
Técnicas de Imagem por Elasticidade , Mama/diagnóstico por imagem , Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia Mamária/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...