Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 10(22)2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34830533

RESUMO

BACKGROUND: The effectiveness of mandibular advancement devices has been solidly demonstrated in the past. They are considered a valid alternative treatment to continuous positive airway pressure for patients with obstructive sleep apnea. Nevertheless, the relationship between polysomnographic parameters and the increase in the volume of the upper airway in patients with obstructive sleep apnea syndrome has not been clearly established so far. This study aimed to determine the impact of these oral appliances upon the volume of the airway after the device titration phase and correlate it with the degree of mandibular advancement and the improvement of polysomnographic parameters. METHODS: All patients were diagnosed by polysomnography and were treated with a customized, titratable mandibular advancement device. Three-dimensional volumetric measurements were performed using cone beam computed tomography. RESULTS: The present study included 45 patients diagnosed with obstructive sleep apnea hypopnea syndrome (mild in 23 patients, moderate in 11 and severe in 11). Forty-four percent of the patients presented with an apnea hypopnea index <5/h at the end of treatment. The volume of the upper airway increased an average of 4.3 ± 5.9 cm3, this represents a percentage increase of 20.9%, which was significantly correlated with an apnea hypopnea index and a minimum oxygen saturation improvement. CONCLUSIONS: The mandibular advancement device used was found to be effective in improving polysomnographic parameters. Moreover, the oral appliance was able to significantly increase the tridimensional dimensions of the upper airway. Moreover, this finding was correlated with a reduction in the apnea hypopnea index (p = 0.007) and an increase on minimum oxygen saturation (p = 0.033).

2.
J Oral Rehabil ; 48(8): 927-936, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33977548

RESUMO

BACKGROUND: The efficiency of the mandibular advancement device (MAD) in patients with obstructive sleep apnoea syndrome (OSAS) has been demonstrated. Nevertheless, the behaviour of the upper airway once MAD is placed and titrated, and its correlation with the apnoea-hypopnoea index (AHI) is still under discussion. OBJECTIVES: To analyse the morphological changes of the upper airway through a bi- and three-dimensional study and correlate it with the polysomnographic variable, AHI. METHODS: Patients were recruited from two different hospitals for the treatment of OSAS with a custom-made MAD. A cone-beam computer tomography and a polysomnography were performed at baseline and once the MAD was titrated. RESULTS: A total of 41 patients completed the study. Treatment with MAD reduced the AHI from 22.5 ± 16.8 to 9.2 ± 11.6 (p ≤ .05). There was a significant increase of the total airway volume with MAD from 21.83 ± 7.05 cm3 to 24.19 ± 8.19 cm3 , at the expense of the oropharynx. Moreover, the correlation between the improvement of the AHI and the augmentation of the volume of the upper airway was not statistically significant. CONCLUSIONS: The oral device used in this prospective study increased the mean upper pharyngeal airway volume and significantly reduced the AHI. Future studies that measure the muscular tone are needed to completely understand the association between the AHI and the physiological and anatomical response of the upper airway.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Placas Oclusais , Polissonografia , Estudos Prospectivos , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
3.
Eur Arch Otorhinolaryngol ; 275(7): 1903-1911, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29679154

RESUMO

PURPOSE: This study aimed to determine the effectiveness of a mandibular advancement device in a sample of obstructive sleep apnea syndrome patients by the evaluation of respiratory and neurophysiologic parameters and clinical symptoms. Second, the influence of certain predictor factors related with the patient and the intraoral device, were considered in the final response with this treatment option. METHODS: Forty-one patients constituted the final sample. Outcomes were measured using polysomnography, Epworth sleepiness scale and an analogue visual snoring scale, before treatment and once the device was properly titrated. RESULTS: Mean apnea-hypopnea index decreased from 22.5 ± 16.8 to 9.1 ± 11.6 (p ≤ 0.05), influencing only gender and Fujita index as predictor factors. The oxygen saturation, arousal index, percentages of sleep stages and sleep efficiency significantly improved with the mandibular advancement device (MAD) placement. The snoring index improved in absolute terms in 6.1 units and the excessive daytime sleepiness was reduced from 12.2 ± 4.7 to 8.5 ± 3.8 (p ≤ 0.00). CONCLUSIONS: The successful treatment rate with the MAD was 65.8%. The placement and posterior regulation of the intraoral appliance efficiently reduced the apnea-hypopnea index, improved the sleep quality and the clinical symptomatology associated. Obstructive sleep apnea syndrome is a highly prevalent disease. and dentists should be aware of the benefits enhanced by this prosthetic device, considered the first treatment option by certain physicians.


Assuntos
Avanço Mandibular/instrumentação , Apneia Obstrutiva do Sono/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Prospectivos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/fisiopatologia , Fases do Sono , Ronco/etiologia , Ronco/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...