Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 31(5): 919-24, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20167651

RESUMO

BACKGROUND AND PURPOSE: Color has been shown to facilitate both visual search and recognition tasks. It was our purpose to examine the impact of a color-coding algorithm on the interpretation of 2D-DSA acquisitions by experienced and inexperienced observers. MATERIALS AND METHODS: Twenty-six 2D-DSA acquisitions obtained as part of routine clinical care from subjects with a variety of cerebrovascular disease processes were selected from an internal data base so as to include a variety of disease states (aneurysms, AVMs, fistulas, stenosis, occlusions, dissections, and tumors). Three experienced and 3 less experienced observers were each shown the acquisitions on a prerelease version of a commercially available double-monitor workstation (XWP, Siemens Healthcare). Acquisitions were presented first as a subtracted image series and then as a single composite color-coded image of the entire acquisition. Observers were then asked a series of questions designed to assess the value of the color-coded images for the following purposes: 1) to enhance their ability to make a diagnosis, 2) to have confidence in their diagnosis, 3) to plan a treatment, and 4) to judge the effect of a treatment. The results were analyzed by using 1-sample Wilcoxon tests. RESULTS: Color-coded images enhanced the ease of evaluating treatment success in >40% of cases (P < .0001). They also had a statistically significant impact on treatment planning, making planning easier in >20% of the cases (P = .0069). In >20% of the examples, color-coding made diagnosis and treatment planning easier for all readers (P < .0001). Color-coding also increased the confidence of diagnosis compared with the use of DSA alone (P = .056). The impact of this was greater for the naïve readers than for the expert readers. CONCLUSIONS: At no additional cost in x-ray dose or contrast medium, color-coding of DSA enhanced the conspicuity of findings on DSA images. It was particularly useful in situations in which there was a complex flow pattern and in evaluation of pre- and posttreatment acquisitions. Its full potential remains to be defined.


Assuntos
Algoritmos , Angiografia Digital/métodos , Colorimetria/métodos , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
AJNR Am J Neuroradiol ; 30(7): 1337-41, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19461063

RESUMO

BACKGROUND AND PURPOSE: Recent advances in flat panel detector angiographic equipment have provided the opportunity to obtain physiologic and anatomic information from angiographic examinations. To exploit this possibility, one must understand the factors that affect the bolus geometry of an intra-arterial injection of contrast medium. It was our purpose to examine these factors in a canine model. MATERIALS AND METHODS: Under an institutionally approved protocol conforming to Guide for the Care and Use of Laboratory Animals of the National Institutes of Health, 7 canines were placed under general anesthesia with isoflurane and propofol. Through a 5F catheter placed into the right common carotid artery, a series of biplane angiographic acquisitions was obtained to examine the effects caused by variation in the volume of injection, the rate of injection, the duration of injection, the concentration of contrast medium, and the catheter position on arterial, capillary, and venous opacification. The results of each injection protocol were determined from analysis of a time-contrast concentration curve derived from locations over an artery, in brain parenchyma, and over a vein. The curve was generated from 2D digital subtraction angiography acquisitions by using prototype software. The area under the curve, the amplitude of the curve, and the time to peak (TTP) were analyzed separately for each injection parameter. RESULTS: Changes in the injection protocols resulted in predictable changes in the time-concentration curves. The injection parameter that contributed most to maximum opacification was the volume of contrast medium injected. When the injection rate was fixed and the volume was varied, there was an increase in opacification (maximal) proportional to the injected volume. The injected volume also had an indirect (secondary) impact on the temporal characteristics of the opacification. The time-concentration curve became wider, and the peak was shifted to the right as the injection duration increased. The impact of injected volume on maximal opacification was significant (P < .0001), regardless of the site of measurement (artery, tissue, and vein); however, the impact on the temporal characteristics of the time-concentration curve reached statistical significance only in measurements made in the artery and the vein (P < .05), but not in the tissue (P > .1). The impact of injected volume on maximal opacification became nonproportional in the tissue and vein when the volume was very large (>12 mL). Increasing the concentration of contrast medium resulted in a nonproportional increase in the height of the time-concentration curves (P < .05). Injection rate had an impact on both maximal opacification and TTP. The impact on TTP occurred only when the injection rate was very slow (1 mL/s). Changes of concentration had a similar impact on the time-concentration curve. Catheter position did not cause significant alterations in the shape of the curves. CONCLUSIONS: There were predictable effects from modification of injection parameters on the contrast bolus geometry and on time-concentration curves as measured in an artery, brain parenchyma, or a vein. The amplitude, TTP, and area under the time-concentration curve depend mainly and proportionally on the amount of iodine traversing the vasculature per second. Other injection parameters were of less importance in defining bolus geometry. These findings mimic those observed in studies of parameters affecting bolus geometry following an intravenous injection.


Assuntos
Angiografia Digital/métodos , Artérias/metabolismo , Capilares/metabolismo , Angiografia Cerebral/métodos , Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Veias/metabolismo , Animais , Capilares/diagnóstico por imagem , Cães , Injeções Intra-Arteriais , Taxa de Depuração Metabólica , Organização e Administração
3.
AJNR Am J Neuroradiol ; 30(5): 917-22, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19299488

RESUMO

BACKGROUND AND PURPOSE: Cerebral blood volume (CBV) is an important parameter in estimating the viability of brain tissue following an ischemic event. We tested the hypothesis that C-arm CT measurements of CBV would correlate well with those made with perfusion CT (PCT). MATERIALS AND METHODS: CBV was measured in 12 canines by using PCT and C-arm CT. Two measurements with each technique were made on each animal; a different injection protocol was used for each of these techniques. PCT was performed by using a 64-section V-scanner. C-arm CT was performed by using a biplane Artis dBA system. PCT images were transferred to a commercially available workstation for postprocessing and analysis; C-arm CT images were transferred to a commercially available workstation for postprocessing and analysis by using prototype software. From each animal, 2 sections from each technique were selected for analysis. RESULTS: There was good agreement of both the color maps and absolute numbers between the 2 techniques. The maximum and mean deviations of values between the 2 techniques for the first 5 animals were 30.20% and 7.82%; for the second 7 animals, these values were 26.79% and 7.40%. The maximum and mean deviations between the 2 C-arm CT studies performed on the first 5 animals were 33.15% and 12.24%; for the second 7 animals, these values were 41.15% and 10.89%. CONCLUSIONS: In these healthy animals, measurement of CBV with C-arm CT compared well with measurements made with PCT.


Assuntos
Determinação do Volume Sanguíneo/métodos , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Angiografia Cerebral/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Cães
4.
Abdom Imaging ; 30(3): 259-62, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15688106

RESUMO

BACKGROUND: We have successfully applied sequential volumetric analysis of abdominal aortic aneurysms to exclude endoleak in patients who have an aortic endostent. This study compared the effect of variable operator experience on volumetric calculation accuracy. METHODS: Four operators with different experience levels calculated abdominal aneurysm volumes in 10 patients at two different times (>/= 1 week apart). The four reviewers were ranked as having a high level of experience (one full-time laboratory worker specializing in three dimensions with 3 years of experience), a moderate level of experience (one part-time laboratory worker specializing in three dimensions/computed tomographic technician with 1 year of part-time experience), and a low level of experience (two individuals taught volumetric measurements for the purposes of this study: a fellow in abdominal imaging and a computed tomographic technician). All volumes were calculated with a GE Advantage 4.0 workstation (General Electric, Waukesha, WI, USA). RESULTS: Mean aneurysm volume and volume difference between two measurements were calculated for four operators. The average (standard deviation) percent volume differences were 1.2% (0.2%) for the experienced reader, 3.2% (0.3%) for the moderately experienced reader, and 6.0% (1.0%) and 5.8% (1.1%) for the two readers with light experience. Differences between averages were statistically significant (p < 0.005). CONCLUSION: We have defined a percent margin of error for aortic aneurysm volume measurement and have shown a direct correlate to level of experience. Diagnosis of endoleak based on aneurysm volume enlargement on serial scans needs to account for the level of operator experience.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Humanos , Variações Dependentes do Observador , Análise e Desempenho de Tarefas , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...