Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Connect Tissue Res ; 60(2): 95-106, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-29560747

RESUMO

AIM: The horse joint, due to its similarity with the human joint, is the ultimate model for translational articular cartilage repair studies. This study was designed to determine the critical size of cartilage defects in the equine carpus and serve as a benchmark for the evaluation of new cartilage treatment options. MATERIAL AND METHODS: Circular full-thickness cartilage defects with a diameter of 2, 4, and 8 mm were created in the left middle carpal joint and similar osteochondral (3.5 mm in depth) defects in the right middle carpal joint of 5 horses. Spontaneously formed repair tissue was examined macroscopically, with MR and µCT imaging, polarized light microscopy, standard histology, and immunohistochemistry at 12 months. RESULTS: Filling of 2 mm chondral defects was good (77.8 ± 8.5%), but proteoglycan depletion was evident in Safranin-O staining and gadolinium-enhanced MRI (T1Gd). Larger chondral defects showed poor filling (50.6 ± 2.7% in 4 mm and 31.9 ± 7.3% in 8 mm defects). Lesion filling in 2, 4, and 8 mm osteochondral defects was 82.3 ± 3.0%, 68.0 ± 4.6% and 70.8 ± 15.4%, respectively. Type II collagen staining was seen in 9/15 osteochondral defects but only in 1/15 chondral defects. Subchondral bone pathologies were evident in 14/15 osteochondral samples but only in 5/15 chondral samples. Although osteochondral lesions showed better neotissue quality than chondral lesions, the overall repair was deemed unsatisfactory because of the subchondral bone pathologies. CONCLUSION: We recommend classifying 4 mm as critical osteochondral lesion size and 2 mm as critical chondral lesion size for cartilage repair research in the equine carpal joint model.


Assuntos
Articulações do Carpo/patologia , Cartilagem Articular/patologia , Cavalos/anatomia & histologia , Animais , Articulações do Carpo/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Imageamento por Ressonância Magnética , Microscopia de Polarização , Fatores de Tempo , Cicatrização , Microtomografia por Raio-X
2.
Ultrasound Med Biol ; 36(5): 833-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20420972

RESUMO

During the last decade, a major effort has been devoted to developing surgical methods for repairing localized articular cartilage lesions. Despite some promising results no ultimate breakthrough in surgical cartilage repair has been achieved. Improvements in repair techniques would benefit from more sensitive and quantitative methods for long-term follow-up of cartilage healing. In this study, the potential of a new ultrasound technique for detecting the compositional and structural changes in articular cartilage after surgery, using recombinant human type II collagen gel and spontaneous repair was, investigated. Rabbit knee joints containing intact (n = 13) and surgically (n = 8) or spontaneously (n = 5) repaired tissue were imaged in situ at 6 months after the operation using a clinical intravascular high-frequency (40 MHz) ultrasound device. Based on the ultrasound raw data, ultrasound reflection coefficient (R), integrated ultrasound reflection coefficient (IRC), apparent integrated backscattering coefficient (AIB) and ultrasound roughness index (URI) were determined for each sample. URI was significantly higher in both repair groups than in intact cartilage (p < 0.05). The reflection parameters (R and IRC) were significantly lower in surgically repaired cartilage (p < 0.05) than in intact cartilage. Furthermore, AIB was significantly higher in surgically repaired cartilage than in intact tissue (p < 0.05). To conclude, the integrity of the rabbit articular cartilage repair could be quantitatively evaluated with the nondestructive ultrasound approach. In addition, clinically valuable qualitative information on the changes in cartilage integration, structure and composition could be extracted from the ultrasound images. In the present study, the structure and properties of repaired tissue were inferior to native tissue at 6 months after the operation. The applied ultrasound device and probes are FDA approved and, thus, applicable for the quantitative in vivo evaluation of human articular cartilage.


Assuntos
Cartilagem Articular/lesões , Cartilagem Articular/cirurgia , Traumatismos do Joelho/diagnóstico por imagem , Traumatismos do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Ultrassonografia de Intervenção/métodos , Animais , Cartilagem Articular/diagnóstico por imagem , Coelhos , Resultado do Tratamento