Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 13(3)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36979598

RESUMO

An electrochemical biosensor was fabricated using nanoparticles of acetylcholinesterase (AChE) and choline oxidase (ChO)/Pt nanoparticles (PtNPs)/porous graphene oxide nanosheet (GONS) composite. A pencil graphite electrode (PGE) was used for the electrodeposition of nanocomposite and the determination of acetylcholine (ACh), a neurotransmitter. Various techniques such as scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), Fourier-transform infrared (FTIR) spectra and cyclic voltammetry (CV) were used for characterization. This biosensor (AChENPs-ChONPs/GONS/PtNPs/PGE) indicated a very short response time (3 s), a lower limit of detection (0.001 µM), good linearity (0.001-200 µM), longer storage stability (6 months) and better reproducibility. The percent analytical recoveries of added acetylcholine in serum (5.0 and 10 µM) were found to be 97.6 ± 0.7 and 96.5 ± 0.3 for the present biosensor. The coefficients of variation were obtained to be 8% and 3.25%, correspondingly. The biosensor was applied to measure the ACh amount in the serum of healthy individuals and patients with Alzheimer's disease. The number of interferents had no effect on the biosensor at their physiological concentrations.


Assuntos
Técnicas Biossensoriais , Grafite , Nanopartículas Metálicas , Nanocompostos , Nanopartículas , Humanos , Acetilcolina , Acetilcolinesterase/química , Reprodutibilidade dos Testes , Enzimas Imobilizadas/química , Nanopartículas/química , Grafite/química , Técnicas Biossensoriais/métodos , Eletrodos , Nanopartículas Metálicas/química
2.
Micromachines (Basel) ; 13(11)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36363867

RESUMO

A notable diagnostic for the detection of hemolytic diseases is bilirubin, a by-product of haemoglobin breakdown. The concentration of bilirubin ranges from 0.3 to 1.9 mg in 100 mL of blood. Low blood bilirubin levels are associated with a greater risk of coronary heart disease and anaemia. Hyperbilirubinemia results from a serum bilirubin level of more than 2.5 mg/100 mL. Therefore, it is very crucial to check the serum bilirubin level. Analytical equipment for point-of-care testing must be portable, small, and affordable. A unique method is used to detect bilirubin selectively using paper-based screen-printed carbon electrodes that were covalently linked with nanoparticles, that serves as a key biomarker for jaundice. In order to create an electrochemical biosensor, bilirubin oxidase was immobilised on electrodes modified with AgNPs. The morphology of Ag nanoparticles in terms of size and shape was determined using both UV- Vis Spectroscopy and transmission electron microscopy (TEM). The biosensor's analytical response was assessed using potentiostat (Cyclic voltammetry (CV) and linear sweep voltammetry (LSV)). The developed paper-based sensor provided optimum feedback and a broad linear range of 1 to 9 µg/mL for bilirubin, with a lower LOD of 1 µg/mL. Through tests of bilirubin in artificial blood serum, the viability is confirmed. The method that is being used makes it possible to create and use an inexpensive, miniature electrochemical sensor.

3.
3 Biotech ; 11(2): 87, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33495723

RESUMO

The influenza virus is classified into four types A, B, C, and D, but type A and B are responsible for major illnesses in people with influenza A being the only virus responsible for flu pandemics due to the presence of two surface proteins called hemagglutinin (H) and neuraminidase (N) on the virus. The two subtypes of influenza A virus, H1N1 and H3N2, have been known to cause many flu pandemics. Both subtypes change genetically and antigenically to produce variants (clades and subclades, also know as groups and subgroups). H3N2 tends to change rapidly, both genetically and antigenically whereas that of H1N1 generally tends to have smaller changes. Influenza A (H3N2) viruses have evolved to form many separate, genetically different clades that continue to co-circulate. Influenza A(H3N2) viruses have caused significant deaths as per WHO report. The review describes methods for detection of influenza A(H3N2) viruses by conventional serological methods as well as the advanced methods of molecular biology and biosensors. All these methods are based on different parameters and have different targets but the goal is to improve specificity and increase sensitivity. Amongst the molecular methods, real-time polymerase chain reaction (RT-PCR) is considered a gold standard test due to its many advantages whereas a number of other molecular methods are time-consuming, complex to perform or lack specificity. The review also considers bio-sensing methods for simple, rapid, highly sensitive, and specific detection of H3N2. The classification and principle of various H3N2 biosensors are also discussed.

4.
Enzyme Microb Technol ; 123: 30-38, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30686348

RESUMO

The nanoparticles of commercially available pyruvate oxidase (POx) from Aerococcus species were prepared by desolvation method, which were then characterized and covalently immobilized onto gold electrode (AuE) to construct an improved model of amperometric pyruvate biosensor. The POxNPs/Au electrode was analyzed morphologically by scanning electron microscopy (SEM). On the other hand, cyclic voltammetry studies (CV) and electrochemical impedance spectroscopy (EIS) helped in deciphering the electrochemical properties of the electrode at different stages of construction. The biosensor showed optimum response within 7.5 s, at a potential of 0.28 V, pH 5.5 and 35 °C. A linear relationship was observed between biosensor response i.e. current (µA) and pyruvate concentration in the range, 0.01 µM - 5000 µM, with a lower detection limit of 0.67 µM. The analytical recovery of added pyruvate in sera was 99.0% and 99.5% within and between batch coefficient of variation (CV) were 0.045% and 0.040% respectively. The working electrode displayed an excellent correlation coefficient (R2 = 0.99%) between levels of pyruvate in sera, as detected by the standard spectrophotometric method and the present biosensor. The biosensor was utilized for detection of total pyruvate level in sera of apparently healthy individuals and patients suffering from cardiogenic stress, more specifically cardiac failure. The activity of the biosensor deteriorated by 25%, after its regular use over a period of 240 days, while being stored dry at 4°C.


Assuntos
Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/química , Ouro/química , Nanopartículas Metálicas/química , Ácido Pirúvico/sangue , Choque Cardiogênico/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Choque Cardiogênico/diagnóstico
5.
ACS Omega ; 3(10): 13020-13027, 2018 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-30411026

RESUMO

The present report employed nanobroom (NB)-shaped two-dimensional molybdenum diselenide (MoSe2) for the preparation of a sensing matrix for the detection of Salmonella paratyphi. An aptamer specific to salmonella was immobilized onto MoSe2NB-modified fluorine-doped tin oxide via glutaraldehyde cross-linking. Structural and morphological characterizations were performed using UV-vis spectroscopy, scanning electron microscopy, Fourier transform infrared spectroscopy, and X-ray diffraction techniques. Characterizations confirmed the nanobroom morphology and nanosize of the MoSe2 material. Electrochemical studies revealed a good linear detection range of 10-2-10-10 CFU/mL with low detection limit of 1 × 10-10 CFU/mL and with R 2 = 0.98. The developed preferable nanobroom-shaped sensing matrix can provide a promising platform for rapid and accurate detection of Salmonella in real samples due to its tremendous stability and sensitivity.

6.
Biosensors (Basel) ; 8(3)2018 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-30110986

RESUMO

The present study was aimed to develop "fluorine doped" tin oxide glass electrode with a MoSe2 nano-urchin based electrochemical biosensor for detection of Escherichia. coli Shiga toxin DNA. The study comprises two conductive electrodes, and the working electrodes were drop deposited using MoSe2 nano-urchin, and DNA sequences specific to Shiga toxin Escherichia. coli. Morphological characterizations were performed using Fourier transforms infrared spectrophotometer; X-ray diffraction technique and scanning electron microscopy. All measurements were done using methylene blue as an electrochemical indicator. The proposed electrochemical geno-sensor showed good linear detection range of 1 fM⁻100 µM with a low detection limit of 1 fM where the current response increased linearly with Escherichia. coli Shiga toxin dsDNA concentration with R2 = 0.99. Additionally, the real sample was spiked with the dsDNA that shows insignificant interference. The results revealed that the developed sensing platform significantly improved the sensitivity and can provide a promising platform for effective detection of biomolecules using minute samples due to its stability and sensitivity.


Assuntos
Técnicas Biossensoriais/métodos , DNA Bacteriano/análise , Técnicas Eletroquímicas/métodos , Molibdênio/química , Nanoestruturas/química , Compostos de Selênio/química , Toxina Shiga/genética , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Eletrodos , Escherichia coli/química , Escherichia coli/genética , Azul de Metileno/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Compostos de Estanho/química
7.
Int J Nanomedicine ; 13(T-NANO 2014 Abstracts): 117-120, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30880958

RESUMO

This paper reports the fabrication of highly sensitive metformin sensor based on Prussian blue (PB) nanocubes/carbon nanosphere (CNS) heterostructures composed of a perfect cube and spherical composite on a fluorine-doped tin oxide surface. Due to the excellent biocompatibility of PB nanocubes the PB/CNS based Mf sensor exhibited a wide linear range of 0.001-10 mM with a response duration of less than 5 s and a detection limit (based on signal to noise ratio) of 0.1 µM.


Assuntos
Técnicas Biossensoriais/métodos , Carbono/química , Ferrocianetos/química , Metformina/análise , Nanosferas/química , Espectroscopia Dielétrica , Eletrodos , Limite de Detecção , Nanosferas/ultraestrutura , Difração de Raios X
8.
Indian J Med Res ; 139(4): 603-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24927348

RESUMO

BACKGROUND & OBJECTIVES: Reusable biostrip consisting enzymes immobilized onto alkylamine glass beads affixed on plasticized PVC strip for determination of triglyceride (TG) suffers from high cost of beads and their detachments during washings for reuse, leading to loss of activity. The purpose of this study was to develop a cheaper and stable biostrip for investigation of TG levels in serum. METHODS: A reusable enzyme-strip was prepared for TG determination by co-immobilizing lipase, glycerol kinase (GK), glycerol-3-phosphate oxidase (GPO) and peroxidase (HRP) directly onto plasticized polyvinyl chloride (PVC) strip through glutaraldehyde coupling. The method was evaluated by studying its recovery, precision and reusability. RESULTS: The enzyme-strip showed optimum activity at pH 7.0, 35 o C and a linear relationship between its activity and triolein concentration in the range 0.1 to 15 mM. The strip was used for determination of serum TG. The detection limit of the method was 0.1 mM. Analytical recovery of added triolein was 96 per cent. Within and between batch coefficients of variation (CV) were 2.2 and 3.7 per cent, respectively. A good correlation (r=0.99) was found between TG values by standard enzymic colrimetric method employing free enzymes and the present method. The strip lost 50 per cent of its initial activity after its 200 uses during the span of 100 days, when stored at 4 o C. INTERPRETATION & CONCLUSIONS: The nitrating acidic treatment of plasticized PVC strip led to glutaraldehyde coupling of four enzymes used for enzymic colourimetric determination of serum TG. The strip provided 200 reuses of enzymes with only 50 per cent loss of its initial activity. The method could be used for preparation of other enzyme strips also.


Assuntos
Análise Química do Sangue/instrumentação , Enzimas Imobilizadas/metabolismo , Cloreto de Polivinila/metabolismo , Fitas Reagentes/metabolismo , Triglicerídeos/sangue , Glicerol Quinase/metabolismo , Glicerolfosfato Desidrogenase/metabolismo , Peroxidase do Rábano Silvestre/metabolismo , Concentração de Íons de Hidrogênio , Cinética , Lipase/metabolismo , Microscopia Eletrônica de Varredura , Espectroscopia de Infravermelho com Transformada de Fourier , Temperatura
9.
Enzyme Microb Technol ; 57: 55-62, 2014 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-24629268

RESUMO

Xanthine (3,7-dihydro-purine-2,6-dione) is generated from guanine by guanine deaminase and hypoxanthine by xanthine oxidase (XOD). The determination of xanthine in meat indicates its freshness, while its level in serum/urine provides valuable information about diagnosis and medical management of certain metabolic disorders such as xanthinuria, hyperurecemia, gout and renal failure. Although chromatographic methods such a HPLC, capillary electrophoresis and mass spectrometry are available for quantification of xanthine in biological materials, these suffer from certain limitations such as complexity, time consuming sample preparation and requirement of expensive apparatus and trained persons to operate. Immobilized XOD based biosensors have emerged as simple, rapid, sensitive and economic tools for determination of xanthine in food industries and clinical diagnosis. This review article describes the various immobilization methods of XOD and different matrices used for construction of xanthine biosensors, their classification, analytical performance and applications along with their merits and demerits. The future perspectives for improvement of present xanthine biosensors are also discussed.


Assuntos
Técnicas Biossensoriais/métodos , Xantina/análise , Técnicas Biossensoriais/tendências , Testes de Química Clínica/métodos , Enzimas Imobilizadas , Análise de Alimentos/métodos , Humanos , Doenças Metabólicas/diagnóstico , Doenças Metabólicas/metabolismo , Xantina Oxidase
10.
Enzyme Microb Technol ; 57: 69-77, 2014 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-24629270

RESUMO

A method is described for construction of a highly sensitive electrochemical biosensor for detection of glutamate. The biosensor is based on covalent immobilization of glutamate oxidase (GluOx) onto polypyrrole nanoparticles and polyaniline composite film (PPyNPs/PANI) electrodeposited onto Au electrode. The enzyme electrode was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), X-ray diffraction (XRD), transmission electron microscopy (TEM), Fourier transform infra-red spectroscopy (FTIR) and electrochemical impedance spectroscopy (EIS). The biosensor showed optimum response within 3s at pH 7.5 (0.1 M sodium phosphate) and 35 °C, when operated at 50 mV s⁻¹. It exhibited excellent sensitivity (detection limit as 0.1 nM), fast response time and wider linear range (from 0.02 to 400 µM). Analytical recovery of added glutamate (5 mM and 10 mM) was 95.56 and 97%, while within batch and between batch coefficients of variation were 3.2% and 3.35% respectively. The enzyme electrode was used 100 times over a period of 60 days, when stored at 4 °C. The biosensor measured glutamate level in food stuff, which correlated well with a standard colorimetric method (r=0.99).


Assuntos
Aminoácido Oxirredutases , Técnicas Biossensoriais/métodos , Ácido Glutâmico/análise , Compostos de Anilina , Espectroscopia Dielétrica , Enzimas Imobilizadas , Análise de Alimentos/métodos , Ouro , Índia , Microscopia Eletrônica de Varredura , Nanopartículas/química , Nanopartículas/ultraestrutura , Polímeros , Pirróis , Difração de Raios X
11.
Anal Biochem ; 444: 47-56, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24090871

RESUMO

The glycated hemoglobin (HbA1c) level in blood is a measure of long-term glycemic status in patients with diabetes mellitus. Current clinical methods for determination of the HbA1c level include electrophoresis/electroendosmosis, ion exchange chromatography, high-performance liquid chromatography, boronate affinity chromatography, immunoassay, and liquid chromatography-tandem mass spectroscopy in addition to fluorometry and colorimetry. These methods have certain drawbacks such as being complex, time-consuming, and requiring expensive apparatus and trained persons to operate. These drawbacks were overcome by biosensing methods. We review these biosensors, which are based on (i) measurement of electrons, that is, current generated from splitting of hydrogen peroxide released during oxidation of fructosyl valine by immobilized fructosyl amino acid oxidase, which is directly proportional to HbA1c concentration, and (ii) direct measurement of HbA1c by some specific reaction. HbA1c biosensors work optimally within 4 to 1800 s, between pH 7.0 and 9.0 and between 25 and 45 °C, and in the range of 1 to 10,000 µM, with a detection limit between 20 and 500 µM and sensitivity between 4.6 nA and 21.5 µA mM⁻¹ cm⁻² and stable over a period of 5 to 90 days. We suggest the ways to modify existing HbA1c biosensors, leading to simple, reliable, and economical sensors ideally suited for point-of-care treatment.


Assuntos
Técnicas Biossensoriais , Hemoglobinas Glicadas/análise , Humanos
12.
Biosens Bioelectron ; 44: 64-9, 2013 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-23395724

RESUMO

A method is described for the construction of a highly sensitive electrochemical biosensor for the detection of bilirubin. The sensor is based on covalent immobilization of bilirubin oxidase (BOx) onto zirconia coated silica nanoparticles (SiO2@ZrONPs)/chitosan (CHIT) composite electrodeposited onto Au electrode. The enzyme electrode was characterized by scanning electron microscopy (SEM), Fourier transform infra-red spectroscopy (FTIR), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The biosensor showed optimum response within 2s at pH 8.5 (0.1M Tris-HCl) and 35°C, when operated at 20 mV s(-1). The biosensor exhibited excellent sensitivity (detection limit as 0.1 nM), fast response time and wider linear range (from 0.02 to 250 µM). Analytical recovery of added bilirubin was 95.56-97.0%. Within batch and between batch coefficients of variation were 3.2% and 3.35% respectively. The enzyme electrode was used 150 times over a period of 120 days, when stored at 4°C. The biosensor measured bilirubin levels in sera of apparently healthy and persons suffering from jaundice, which correlated well with a standard colorimetric method (r=0.99).


Assuntos
Bilirrubina/sangue , Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/metabolismo , Nanopartículas/química , Oxirredutases atuantes sobre Doadores de Grupo CH-CH/metabolismo , Dióxido de Silício/química , Zircônio/química , Quitosana/química , Enzimas Imobilizadas/química , Feminino , Ouro/química , Humanos , Limite de Detecção , Masculino , Modelos Moleculares , Oxirredutases atuantes sobre Doadores de Grupo CH-CH/química
13.
Anal Bioanal Chem ; 405(10): 3049-62, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23392406

RESUMO

Sulfite is used as a preservative in a variety of food and pharmaceutical industries to inhibit enzymatic and nonenzymatic browning and in brewing industries as an antibacterial and antioxidizing agent. Convenient and reproducible analytical methods employing sulfite oxidase are an attractive alternative to conventional detection methods. Sulfite biosensors are based on measurement of either O2 or electrons generated from splitting of H2O2 or heat released during oxidation of sulfite by immobilized sulfite oxidase. Sulfite biosensors can be grouped into 12 classes. They work optimally within 2 to 900 s, between pH 6.5 and 9.0, 25 and 40 °C, and in the range from 0 to 50,000 µM, with detection limit between 0.2 and 200 µM. Sulfite biosensors measure sulfite in food, beverages, and water and can be reused 100-300 times over a period of 1-240 days. The review presents the principles, merits, and demerits of various analytical methods for determination of sulfite, with special emphasis on sulfite biosensors.


Assuntos
Técnicas Biossensoriais/métodos , Análise de Alimentos , Conservantes de Alimentos/análise , Sulfitos/análise
14.
Anal Biochem ; 430(1): 16-23, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22863983

RESUMO

A method is described for construction of a highly sensitive amperometric biosensor for measurement of total phenolic compounds in wine by immobilizing laccase covalently onto nanocomposite of silver nanoparticles (AgNPs)/zinc oxide nanoparticles (ZnONPs) electrochemically deposited onto gold (Au) electrode. Scanning electron microscopy, X-ray diffraction, and electrochemical impedance spectroscopy were applied for characterization of the surface morphology of the modified electrode, and cyclic voltammetry was used to investigate the electrochemical properties of the proposed electrode toward the oxidation of guaiacol. The linearity between the oxidation current and the guaiacol concentration was obtained in a range of 0.1 to 500µM with a detection limit of 0.05µM (signal-to-noise ratio (S/N)=3) and sensitivity of 0.71µAµM(-1)cm(-2). The electrode showed increased oxidation and reduced reduction current with the deposition of AgNPs/ZnONPs on it. R(CT) values of ZnONPs/Au, AgNPs/ZnONPs/Au, and laccase/AgNPs/ZnONPs/Au electrode were 220, 175, and 380Ω, respectively. The biosensor showed an optimal response within 8s at pH 6.0 (0.1M acetate buffer) and 35°C when operated at 0.22V against Ag/AgCl. Analytical recovery of added guaiacol was 98%. The method showed a good correlation (r=0.99) with the standard spectrophotometric method, with the regression equation being y=1.0053x-3.5541. The biosensor lost 25% of its initial activity after 200 uses over 5months.


Assuntos
Técnicas Biossensoriais/métodos , Ouro/química , Lacase/metabolismo , Fenóis/análise , Prata/química , Vinho/análise , Óxido de Zinco/química , Técnicas Biossensoriais/instrumentação , Impedância Elétrica , Eletroquímica , Eletrodos , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Ganoderma/enzimologia , Lacase/química , Modelos Lineares , Nanopartículas Metálicas/química , Propriedades de Superfície
15.
Anal Biochem ; 430(2): 156-62, 2012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22906687

RESUMO

Measurement of hemoglobin A1c (HbA1c, glycated hemoglobin) level in blood provides the long-term glucose level in diabetic patients without the influence of short-term fluctuations. The existing methods for HbA1c determination, including biosensors, suffer from insufficient sensitivity, detection limit, response time, and storage stability. These problems were overcome in the current biosensor. A method is described for construction of an amperometric HbA1c biosensor by immobilizing a fructosyl amino acid oxidase (FAO) onto zinc oxide nanoparticles/polypyrrole (ZnONPs/PPy) hybrid film deposited onto gold (Au) electrode and using it as working electrode, Ag/AgCl as reference electrode, and platinum (Pt) as auxiliary electrode. The whole blood samples were hemolyzed and digested by protease before measuring their HbA1c level by the biosensor. The enzyme electrode detected fructosyl valine (FV) as low as 50µM at a signal-to-noise ratio of 3 within 2s at +0.27V versus Ag/AgCl, pH7.0, and 35°C with a linear working range of 0.1 to 3.0mM for FV and sensitivity of 38.42µAmM(-1). The electrode showed only a 30% loss of its initial response over a period of 160days when stored at 4°C. The biosensor measured HbA1c in whole blood of apparently healthy individuals and diabetic patients and found it to be in the ranges of 4.0% to 5.6% and 5.7% to 12.0%, respectively.


Assuntos
Aminoácido Oxirredutases/metabolismo , Técnicas Eletroquímicas , Hemoglobinas Glicadas/análise , Nanopartículas Metálicas/química , Polímeros/química , Pirróis/química , Óxido de Zinco/química , Adulto , Aminoácido Oxirredutases/química , Técnicas Biossensoriais , Eletrodos , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Feminino , Humanos , Masculino , Nanopartículas Metálicas/ultraestrutura , Pessoa de Meia-Idade , Razão Sinal-Ruído , Valina/análogos & derivados , Valina/análise
16.
Anal Biochem ; 429(1): 19-31, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22759777

RESUMO

Pesticides released intentionally into the environment and through various processes contaminate the environment. Although pesticides are associated with many health hazards, there is a lack of monitoring of these contaminants. Traditional chromatographic methods-high-performance liquid chromatography, capillary electrophoresis, and mass spectrometry-are effective for the analysis of pesticides in the environment but have certain limitations such as complexity, time-consuming sample preparation, and the requirement of expensive apparatus and trained persons to operate. Over the past decades, acetylcholinesterase (AChE) inhibition-based biosensors have emerged as simple, rapid, and ultra-sensitive tools for pesticide analysis in environmental monitoring, food safety, and quality control. These biosensors have the potential to complement or replace the classical analytical methods by simplifying or eliminating sample preparation and making field-testing easier and faster with significant decrease in cost per analysis. This article reviews the recent developments in AChE inhibition-based biosensors, which include various immobilization methods, different strategies for biosensor construction, the advantages and roles of various matrices used, analytical performance, and application methods for constructing AChE biosensors. These AChE biosensors exhibited detection limits and linearity in the ranges of 1.0×10(-11) to 42.19 µM (detection limits) and 1.0×10(-11)-1.0×10(-2) to 74.5-9.9×10(3)µM (linearity). These biosensors were stable for a period of 2 to 120days. The future prospects for the development of better AChE biosensing systems are also discussed.


Assuntos
Acetilcolinesterase/metabolismo , Técnicas Biossensoriais/métodos , Inibidores da Colinesterase/farmacologia , Praguicidas/análise , Acetilcolinesterase/química , Animais , Enzimas Imobilizadas/antagonistas & inibidores , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Humanos
17.
Artigo em Inglês | MEDLINE | ID: mdl-22192070

RESUMO

A method is described for construction of an amperometric polyphenol biosensor employing nitrocellulose membrane-bound laccase purified from cell-free extract of Ganoderma lucidum onto a Pt electrode. The biosensor showed optimum response within 10s, at 0.4 V in 0.1M acetate buffer, pH 6.0, and 35°C. Detection limit of the biosensor was 3.0 × 10(-8)M. Analytical recovery of added guaiacol was 97.00%. Within batch and between batch coefficients of variation were <0.97% and <1.26%, respectively. The sensor measured total phenolic content in fruit juices and alcoholic beverages. The enzyme electrode was used 100 times over 4 months, when stored at 4°C.


Assuntos
Técnicas Biossensoriais/métodos , Colódio/química , Enzimas Imobilizadas/química , Lacase/química , Membranas Artificiais , Polifenóis/análise , Reishi/enzimologia , Bebidas Alcoólicas/análise , Antioxidantes/análise , Antioxidantes/química , Quitosana/química , Difusão , Eletroquímica , Enzimas Imobilizadas/metabolismo , Frutas/química , Glutaral/química , Concentração de Íons de Hidrogênio , Lacase/metabolismo , Limite de Detecção , Modelos Lineares , Fenômenos Mecânicos , Polifenóis/química , Porosidade , Propriedades de Superfície , Temperatura
18.
Biosens Bioelectron ; 31(1): 144-50, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-22035973

RESUMO

A sulfite oxidase (SO(X)) (EC 1.8.3.1) purified from Syzygium cumini leaves was immobilized onto carboxylated gold coated magnetic nanoparticles (Fe(3)O(4)@GNPs) electrodeposited onto the surface of a gold (Au) electrode through N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC)-N-hydroxy succinimide (NHS) chemistry. An amperometric sulfite biosensor was fabricated using SO(X)/Fe(3)O(4)@GNPs/Au electrode as working electrode, Ag/AgCl as standard and Pt wire as auxiliary electrode. The working electrode was characterized by Fourier Transform Infrared (FTIR) Spectroscopy, Cyclic Voltammetry (CV), Scanning Electron Microscopy (SEM) and Electrochemical Impedance Spectroscopy (EIS) before and after immobilization of SO(X). The biosensor showed optimum response within 2s when operated at 0.2V (vs. Ag/AgCl) in 0.1 M Tris-HCl buffer, pH 8.5 and at 35 °C. Linear range and detection limit were 0.50-1000 µM and 0.15 µM (S/N=3) respectively. Biosensor was evaluated with 96.46% recovery of added sulfite in red wine and 1.7% and 3.3% within and between batch coefficients of variation respectively. Biosensor measured sulfite level in red and white wines. There was good correlation (r=0.99) between red wines sulfite value by standard DTNB (5,5'-dithio-bis-(2-nitrobenzoic acid)) method and the present method. Enzyme electrode was used 300 times over a period of 4 months, when stored at 4 °C. Biosensor has advantages over earlier biosensors that it has excellent electrocatalysis towards sulfite, lower detection limit, higher storage stability and no interference by ascorbate, cysteine, fructose and ethanol.


Assuntos
Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Ouro/química , Nanopartículas de Magnetita/química , Sulfito Oxidase/química , Sulfitos/análise , Syzygium/enzimologia , Eletrodos , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Extratos Vegetais/química , Folhas de Planta/enzimologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Anal Bioanal Chem ; 401(8): 2599-608, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21877188

RESUMO

A sulfite oxidase (SOx) purified from leaves of Syzygium cumini (Jamun) was immobilized covalently onto a gold nanoparticles (AuNPs)/chitosan (CHIT)/carboxylated multiwalled carbon nanotubes (cMWCNTs)/polyaniline (PANI) composite that was electrodeposited onto the surface of a gold (Au) electrode. A novel and highly sensitive sulfite biosensor was developed that used this enzyme electrode (SOx/AuNPs/CHIT/cMWCNT/PANI/Au) as the working electrode, Ag/AgCl as the standard electrode, and Pt wire as the auxiliary electrode. The modified electrode was characterized by Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), scanning electron microscopy (SEM), and electrochemical impedance spectroscopy (EIS) before and after the immobilization of the SOx. The sensor produced its optimum response within 3 s when operated at 50 mVs(-1) in 0.1 M phosphate buffer, pH 7.0, and at 35 °C. The linear range and detection limit of the sensor were 0.75-400 µM and 0.5 µM (S/N = 3), respectively. The biosensor was employed to determine sulfite levels in fruit juices and alcoholic beverages. The enzyme electrode was used 300 times over a period of three months when stored at 4 °C.


Assuntos
Bebidas/análise , Técnicas Biossensoriais/métodos , Ouro/química , Nanopartículas/química , Nanotubos de Carbono/química , Sulfitos/análise , Bebidas Alcoólicas/análise , Compostos de Anilina/química , Quitosana/química , Técnicas Eletroquímicas/métodos , Eletrodos , Sensibilidade e Especificidade
20.
Anal Chim Acta ; 701(1): 66-74, 2011 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-21763810

RESUMO

An acetylcholinesterase (AChE) purified from maize seedlings was immobilized covalently onto iron oxide nanoparticles (Fe(3)O(4)NP) and carboxylated multi walled carbon nanotubes (c-MWCNT) modified Au electrode. An organophosphorus (OP) biosensor was fabricated using this AChE/Fe(3)O(4)/c-MWCNT/Au electrode as a working electrode, Ag/AgCl as standard and Pt wire as an auxiliary electrode connected through a potentiostat. The biosensor was based on inhibition of AChE by OP compounds/insecticides. The properties of nanoparticles modified electrodes were studied by scanning electron microscopy (SEM), Fourier transform infrared (FTIR), cyclic voltammograms (CVs) and electrochemical impedance spectroscopy (EIS). The synergistic action of Fe(3)O(4)NP and c-MWCNT showed excellent electrocatalytic activity at low potential (+0.4V). The optimum working conditions for the sensor were pH 7.5, 35°C, 600 µM substrate concentration and 10 min for inhibition by pesticide. Under optimum conditions, the inhibition rates of OP pesticides were proportional to their concentrations in the range of 0.1-40 nM, 0.1-50 nM, 1-50 nM and 10-100 nM for malathion, chlorpyrifos, monocrotophos and endosulfan respectively. The detection limits were 0.1 nM for malathion and chlorpyrifos, 1 nM for monocrotophos and 10nM for endosulfan. The biosensor exhibited good sensitivity (0.475 mA µM(-1)), reusability (more than 50 times) and stability (2 months). The sensor was suitable for trace detection of OP pesticide residues in milk and water.


Assuntos
Acetilcolinesterase/metabolismo , Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/metabolismo , Inseticidas/análise , Nanopartículas/química , Compostos Organofosforados/análise , Zea mays/enzimologia , Acetilcolinesterase/química , Animais , Espectroscopia Dielétrica , Enzimas Imobilizadas/química , Compostos Férricos/química , Ouro/química , Inseticidas/metabolismo , Leite/química , Nanopartículas/ultraestrutura , Nanotubos de Carbono/química , Nanotubos de Carbono/ultraestrutura , Compostos Organofosforados/metabolismo , Plântula/enzimologia , Sensibilidade e Especificidade , Espectroscopia de Infravermelho com Transformada de Fourier , Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...