Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Oper Dent ; 46(5): 537-546, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34929042

RESUMO

The aim of this in vitro study was to quantitatively evaluate the internal gap of resin composites of high-and low-viscosity used in single- and incremental-fill techniques in Class I cavities exposed to thermal cycling (TC) using optical coherence tomography (OCT). Cavities of 4-mm depth and 3-mm diameter were prepared in 36 third molars randomly distributed into four groups, according to viscosity of restorative resin-based composite (high or low viscosity, all from 3M Oral Care) and technique application (bulk or incremental fill) used (n=9): RC, high-viscosity, incremental-fill, resin-based composite (Filtek Z350 XT Universal Restorative); BF, high-viscosity, bulk-fill, resin-based composite (Filtek One Bulk Fill); LRC, lowviscosity, incremental-fill, resin-based composite (Filtek Z350 XT Flowable Universal Restorative); and LBF, low-viscosity, bulk-fill, resin-based composite (Filtek Flowable Restorative). Single Bond Universal Adhesive system (3M Oral Care) was used in all the experimental groups. The incremental-fill technique was used for RC and LRC groups (2-mm increments), and a single-layer technique was used for BF and LBF groups, as recommended by the manufacturer. The internal adaptation of the resin at all dentin walls was evaluated before and after TC (5000 cycles between 5°C and 55°C) using OCT images. Five images of each restored tooth were obtained. Images were analyzed using ImageJ software that measured the entire length of the gaps at the dentin-restoration interface. The length of gaps (µm) was analyzed using two-way repeated measures ANOVA and the Tukey tests (α=0.05). There was a significant interaction between material types and TC (p=0.006), and a significant difference among all material types (p<0.0001), before and after TC (p<0.0001). Increased internal gaps at the dentin-restoration interface were noticed after TC for all groups. RC presented the lowest value of internal gap before and after TC, while LBF showed the highest values of internal gap after TC. In conclusion, TC negatively affected the integrity of internal gap, whereas high-viscosity, incremental-fill, resin-based composite presented better performance in terms of internal adaptation than low-viscosity, bulk-fill materials in Class I cavities.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Resinas Compostas/química , Resinas Compostas/uso terapêutico , Materiais Dentários/química , Restauração Dentária Permanente/métodos , Humanos , Teste de Materiais , Tomografia de Coerência Óptica , Viscosidade
2.
Oper Dent ; 46(5): 547-558, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35486506

RESUMO

AIM: To evaluate the influence of different enamel etching times on the bond strength of two self-adhesive resin cements (RCs) with and without thermocycling (TMC). METHODS: One hundred twenty bovine teeth were used. Blocks of enamel (8×4×2mm) were obtained, polished, and randomly divided into two groups, according to the RC used: MaxCem Elite or RelyX U200. Groups were subdivided into four groups (n=16), according to the etching time: Control (0 seconds), 5 seconds, 10 seconds, and 20 seconds. Three RC cylinders (1-mm diameter) were built on each enamel block. The specimens were submitted to two storage conditions: 24 hours in distilled water or TMC (5000 cycles/5°C-55°C). Afterward, the specimens were submitted to the shear bond strength (SBS) test. The failure modes and adhesive interfaces were analyzed by scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). Data were analyzed with three-way analysis of variance (ANOVA) and Tukey test (α=0.05). RESULTS: Etching increased the SBS for both the RCs,especially forthe groups etched for 5 and 10 seconds. TMC affected negatively the SBS of the control groups (p<0.05). No resin tags were observed in control groups, and the formation of tags was time dependent. CONCLUSION: The 10 seconds etching time was more effective in increasing the enamel-resin bond strength. TMC negatively affected bond strength in specimens without acid etching.


Assuntos
Colagem Dentária , Cimentos de Resina , Condicionamento Ácido do Dente , Animais , Bovinos , Cimentos Dentários , Esmalte Dentário , Cimentos de Resina/química
3.
J Dent Res ; 98(3): 347-354, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30612505

RESUMO

The major goal in restorative dentistry is to develop a true regenerative approach that fully recovers hydroxyapatite crystals within the caries lesion. Recently, a rationally designed self-assembling peptide P11-4 (Ace-QQRFEWEFEQQ-NH2) has been developed to enhance remineralization on initial caries lesions, yet its applicability on dentin tissues remains unclear. Thus, the present study investigated the interaction of P11-4 with the organic dentin components as well as the effect of P11-4 on the proteolytic activity, mechanical properties of the bonding interface, and nanoleakage evaluation to artificial caries-affected dentin. Surface plasmon resonance and atomic force microscopy indicated that P11-4 binds to collagen type I fibers, increasing their width from 214 ± 4 nm to 308 ± 5 nm ( P < 0.0001). P11-4 also increased the resistance of collagen type I fibers against the proteolytic activity of collagenases. The immediate treatment of artificial caries-affected dentin with P11-4 enhanced the microtensile bonding strength of the bonding interface ( P < 0.0001), reaching values close to sound dentin and decreasing the proteolytic activity at the hybrid layer; however, such effects decreased after 6 mo of water storage ( P < 0.05). In conclusion, P11-4 interacts with collagen type I, increasing the resistance of collagen fibers to proteolysis, and improves stability of the hybrid layer formed by artificial caries-affected dentin.


Assuntos
Colagem Dentária , Cárie Dentária , Dentina/metabolismo , Colágeno , Adesivos Dentinários , Glicosiltransferases , Humanos , Teste de Materiais , Proteólise , Cimentos de Resina , Resistência à Tração
4.
JDR Clin Trans Res ; 3(1): 35-46, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29276776

RESUMO

Chédiak-Higashi syndrome (CHS), a rare autosomal recessive disorder caused by mutations in the lysosomal trafficking regulator gene (LYST), is associated with aggressive periodontitis. It is suggested that LYST mutations affect the toll-like receptor (TLR)-mediated immunoinflammatory response, leading to frequent infections. This study sought to determine the periodontal status of patients with classic (severe) and atypical (milder) forms of CHS and the immunoregulatory functions of gingival fibroblasts in CHS patients. In contrast to aged-matched healthy controls, atypical (n = 4) and classic (n = 3) CHS patients presented with mild chronic periodontitis with no evidence of gingival ulceration, severe tooth mobility, or premature exfoliation of teeth. As a standard of care, all classic CHS patients had undergone bone marrow transplantation (BMT). Primary gingival fibroblasts obtained from atypical and BMT classic CHS patients displayed higher protein expression of TLR-2 (1.81-fold and 1.56-fold, respectively) and decreased expression of TLR-4 (-2.5-fold and -3.85-fold, respectively) at baseline when compared with healthy control gingival fibroblasts. When challenged with whole bacterial extract of Fusobacterium nucleatum, both atypical and classic CHS gingival fibroblasts failed to up-regulate TLR-2 and TLR-4 expression when compared with their respective untreated groups and control cells. Cytokine multiplex analysis following F. nucleatum challenge showed that atypical CHS gingival fibroblasts featured significantly increased cytokine expression (interleukin [IL]-2, IL-4, IL-5, IL-6, IL-10, IL-12, interferon-γ, tumor necrosis factor-α), whereas classic CHS cells featured similar/decreased cytokine expression when compared with treated control cells. Collectively, these results suggest that LYST mutations in CHS patients affect TLR-2 and TLR-4 expression/function, leading to dysregulated immunoinflammatory response, which in turn may influence the periodontal phenotype noted in CHS patients. Furthermore, our results suggest that atypical CHS patients and classic CHS patients who undergo BMT early in life are less susceptible to aggressive periodontitis and that hematopoietic cells play a critical role in mitigating the risk of aggressive periodontitis in CHS. Knowledge Transfer Statement: Results from this study can be used to create awareness among clinicians and researchers that not all CHS patients exhibit historically reported aggressive periodontitis, especially if they have atypical CHS disease or have received bone marrow transplantation. LYST mutations in CHS patients may affect TLR-2 and TLR-4 expression/function leading to dysregulated immunoinflammatory response, which in turn may influence the periodontal phenotype noted in CHS patients.

5.
Oper Dent ; 42(6): 606-615, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28708007

RESUMO

The aim of this study was to evaluate the influence of different concentrations of hydrofluoric acid (HF) associated with varied etching times on the microshear bond strength (µSBS) of a resin cement to a lithium disilicate glass ceramic. Two hundred seventy-five ceramic blocks (IPS e.max Press [EMX], Ivoclar Vivadent), measuring 8 mm × 3 mm thickness, were randomly distributed into five groups according to the HF concentrations (n=50): 1%, 2.5%, 5%, 7.5%, and 10%. Further random distribution into subgroups was performed according to the following etching times (n=10): 20, 40, 60, 120, and 20 + 20 seconds. After etching, all blocks were treated with a silane coupling agent followed by a thin layer of an unfilled resin. Three resin cement cylinders (∅=1 mm) were made on each EMX surface, which was then stored in deionized water at 37°C for 24 hours before testing. The µSBS was in a universal testing machine at a crosshead speed of 1 mm/min until failure. Data were submitted to two-way analysis of variance, and multiple comparisons were performed using the Tukey post hoc test (α=0.05). One representative EMX sample was etched according to the description of each subgroup and evaluated using scanning electron microscopy for surface characterization. The HF concentrations of 5%, 7.5%, and 10% provided significantly higher µSBS values than 1% and 2.5% (p<0.05), regardless of the etching times. For 1% and 2.5% HF, the etching times from 40 to 120 seconds increased the µSBS values compared with 20 seconds (p<0.05), but etching periods did not differ within the 5%, 7.5%, and 10% HF groups (p>0.05). The effect of re-etching was more evident for 1% and 2.5% HF (p<0.05). Different HF concentrations/etching times directly influenced the bond strength and surface morphology of EMX.


Assuntos
Cerâmica/uso terapêutico , Colagem Dentária/métodos , Corrosão Dentária/métodos , Porcelana Dentária/uso terapêutico , Ácido Fluorídrico/uso terapêutico , Análise do Estresse Dentário , Ácido Fluorídrico/administração & dosagem , Técnicas In Vitro , Resistência ao Cisalhamento
7.
Oper Dent ; 42(1): E16-E23, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27689769

RESUMO

The present study aimed to characterize the pattern and volume of polymerization shrinkage of flowable resin composites, including one conventional, two bulk fill, and one self-adhesive. Standardized class I preparations (2.5 mm depth × 4 mm length × 4 mm wide) were performed in 24 caries-free human third molars that were randomly divided in four groups, according to the resin composite and adhesive system used: group 1 = Permaflo + Peak Universal Bond (PP); group 2 = Filtek Bulk Fill + Scotchbond Universal (FS); group 3 = Surefil SDR + XP Bond (SX); and group 4 = Vertise flow self-adhering (VE) (n=6). Each tooth was scanned three times using a microcomputed tomography (µCT) apparatus. The first scan was done after the cavity preparation, the second after cavity filling with the flowable resin composite before curing, and the third after it was cured. The µCT images were imported into three-dimensional rendering software, and volumetric polymerization shrinkage percentage was calculated for each sample. Data were submitted to one-way analysis of variance and post hoc comparisons. No significant difference was observed among PP, FS, and VE. SX bulk fill resin composite presented the lowest values of volumetric shrinkage. Shrinkage was mostly observed along the occlusal surface and part of the pulpal floor. In conclusion, polymerization shrinkage outcomes in a 2.5-mm deep class I cavity were material dependent, although most materials did not differ. The location of shrinkage was mainly at the occlusal surface.


Assuntos
Resinas Compostas/química , Restauração Dentária Permanente/métodos , Microtomografia por Raio-X , Cimentos Dentários , Adesivos Dentinários , Humanos , Técnicas In Vitro , Teste de Materiais , Dente Serotino , Polimerização , Distribuição Aleatória , Cimentos de Resina , Propriedades de Superfície
8.
Oper Dent ; 41(2): 162-70, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26266651

RESUMO

The present study evaluated the tooth/noncarious cervical lesion restoration interface when using different adhesive systems and resin composites, submitted to thermal cycling (TC), using optical coherence tomography (OCT). Noncarious cervical lesion (NCCL) preparations (0.7 mm depth × 2 mm diameter) were performed on 60 human third molars and randomly divided into six groups, according to the adhesive system and resin composite used: group 1 = Adper Single Bond 2 (SB2) + Aelite LS Posterior (AP); group 2 = SB2 + Venus Diamond (VD); group = SB2 + Filtek Z250XT (Z250); group 4 = Clearfil SE Bond (CSE) + AP; group 5 = CSE + VD; group 6 = CSE + Z250. Selective enamel etching was performed for 30 seconds on groups 4, 5, and 6, while groups 1, 2, and 3 were etched for 30 seconds in enamel and 15 seconds in dentin. All groups were evaluated using OCT before and after TC (n=10). Images were analyzed using Image J software; enamel and dentin margins were separately evaluated. Data from OCT were submitted to PROC MIXED for repeated measurements and Tukey Kramer test (α = 0.05). No marginal gaps were observed in etched enamel, either before or after TC, for all adhesive and resin composite systems. A significant interaction was found between adhesive system and TC for the dentin groups; after TC, restorations with CSE showed smaller gaps at the dentin/restoration interface compared with SB2 for all resin composites. Increased gap percentages were noticed after TC compared with the gaps before TC for all groups. In conclusion, TC affected marginal integrity only in dentin margins, whereas etched enamel margins remained stable even after TC. Dentin margins restored with CSE adhesive system showed better marginal adaptation than those restored with SB2. Resin composites did not influence marginal integrity of NCCL restorations.


Assuntos
Resinas Compostas/química , Cimentos Dentários/química , Restauração Dentária Permanente/métodos , Dente Serotino/diagnóstico por imagem , Tomografia de Coerência Óptica , Condicionamento Ácido do Dente , Preparo da Cavidade Dentária , Adaptação Marginal Dentária , Materiais Dentários/química , Humanos , Cimentos de Resina
9.
Oper Dent ; 40(6): E250-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26266656

RESUMO

OBJECTIVE: The objective of this study was to evaluate the color stability of Icon-infiltrated white spot lesions after staining and the bleaching effect on the infiltrated and stained surfaces. METHODS AND MATERIALS: Enamel-dentin specimens (N=30, 5 × 5 × 3 mm, 1-mm enamel + 2-mm dentin thickness) were prepared from bovine incisors and randomly allocated into three groups (n=10): control, demineralized, and infiltrated. Artificial enamel subsurface lesions were created using 50 mL of 0.05 M acetate buffer solution. Specimens were produced by Icon application in enamel caries-like lesions, according to the manufacturer's instruction. Baseline color readings were assessed using a spectrophotometer, and CIE L*a*b* measurements of each specimen were performed using a white background. To simulate extrinsic dietary staining, specimens were placed into a 4-mL coffee infusion, three times daily for 15 minutes, for 14 days. After the staining procedure, color measurements were performed again. Then, bleaching procedures were performed using 16% carbamide peroxide gel for four hours daily for 21 days, and a final color assessment was performed. To compare the baseline and final measurements, t-test was used (α =0.05). The statistical comparison between the groups was performed using the one-way analysis of variance and Tukey tests (α =0.05). RESULTS: Coffee staining provided a significant reduction of L* values and an increase of a* and b* in all groups (control, decayed, and infiltrated). The bleaching procedure provided a significant increase in L* and decrease of a* and b* values in all groups. There was no significant difference in ΔE values between decayed and infiltrated groups before bleaching, and after bleaching, the infiltrated group showed the lowest ΔE values. CONCLUSION: It can be concluded that enamel infiltrated with Icon presents significant alteration of color after staining when compared with sound enamel. However, if there is discoloration of the infiltrant, the bleaching treatment can be used successfully.


Assuntos
Cor , Cárie Dentária/terapia , Resinas Sintéticas/química , Coloração e Rotulagem , Clareamento Dental , Animais , Bovinos , Restauração Dentária Permanente , Teste de Materiais , Distribuição Aleatória , Resinas Sintéticas/administração & dosagem , Soluções , Espectrofotometria , Descoloração de Dente
10.
Oper Dent ; 39(3): E109-17, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24289802

RESUMO

OBJECTIVES: The aim of this in vitro study was to investigate the effect of chemical degradation on the surface roughness (Ra) and hardness (Knoop hardness number [KHN]) of nano restorative materials. METHODS: Disc-shaped specimens (5-mm diameter; 2-mm thick) of Filtek Z350 and TPH Spectrum composites and the Vitremer and Ketac Nano light-curing glass ionomer cements were prepared according to the manufacturers' instructions. After 24 hours, polishing procedures were performed and initial measurements of Ra and KHN were taken. The specimens were divided into 12 groups (n=10) according to material and storage media: artificial saliva, orange juice, and Coca-Cola. After 30 days of storage, the specimens were reevaluated for Ra and KHN. The pH values of the storage media were measured weekly. Data were tested for significant differences by repeated-measures three-way analysis of variance and Tukey tests (p<0.05). RESULTS: Composites were found to present lower roughness values and higher hardness values than the ionomeric materials under all storage conditions. After degradation, the KHN of all experimental samples decreased significantly, while the Ra of the ionomeric materials increased, depending on the media, with a markedly negative impact of Coca-Cola and orange juice. There was no difference among the storage media for Filtek Z350 with regard to the KHN values. Nanofillers did not show any influence on the roughness and hardness of resin-modified glass ionomer cements and resin composites concerning their degradation resistance.


Assuntos
Resinas Compostas/metabolismo , Desgaste de Restauração Dentária , Cimentos de Ionômeros de Vidro/metabolismo , Óxido de Magnésio/metabolismo , Nanoestruturas , Cimento de Policarboxilato/metabolismo , Óxido de Zinco/metabolismo , Restauração Dentária Permanente/métodos , Dureza , Humanos , Técnicas In Vitro , Cura Luminosa de Adesivos Dentários , Propriedades de Superfície
11.
Oper Dent ; 37(5): 509-17, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22433031

RESUMO

Nanofillers have been incorporated into glass ionomer (GI) restorative materials to improve their mechanical and surface properties. The aim of this present laboratory study was to compare the superficial roughness (Ra) of nanofilled GI (Ketac N100) with that of conventional GI (Fuji IX GP), resin-modified GI (Vitremer), and a nanofilled resin composite (Filtek Supreme) after pH cycling and toothbrush abrasion. Ten specimens of each material were made using Teflon molds, which were polished using aluminum-oxide abrasive disks. Three measurements of Ra were made of each specimen to serve as baseline values. The specimens were submitted to pH cycling for 10 days in a demineralization solution for six hours (pH 4.3) and were then stored in remineralization solution for 18 hours (pH 7.0). Ra measurements were recorded after the pH cycling. Specimens were then submitted to toothbrush abrasion in a brushing machine with a 200g load for 30,000 cycles at 250 cycles/min. The Ra values were then recorded. The surface morphology of specimens from each group was analyzed using a scanning electron microscope. Data were analyzed by analysis of variance, Tukey, and t-tests. After toothbrushing, only Fuji IX GP (1.10 ± 0.80) showed Ra values that were statistically different from those of the other materials evaluated. Ketac N100 (0.68 ± 0.16) showed intermediate Ra values, but it did not differ statistically from the results associated with Vitremer (1.04 ± 0.46) and Filtek (0.30 ± 0.15). Ketac N100 showed intermediate values of superficial roughness among the conventional glass ionomer cement, resin-modified glass ionomer cements, and the nanofilled resin after chemical and mechanical degradation.


Assuntos
Resinas Compostas/química , Cimentos de Ionômeros de Vidro/química , Nanocompostos/química , Nanopartículas/química , Óxido de Alumínio/química , Polimento Dentário/instrumentação , Humanos , Concentração de Íons de Hidrogênio , Teste de Materiais , Microscopia Eletrônica de Varredura , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo , Escovação Dentária/instrumentação
12.
Oper Dent ; 37(2): 188-94, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22166106

RESUMO

The aim of this study was to assess Knoop hardness at different depths of a dual-cured self-adhesive resin cement through different thicknesses of Empress Esthetic® ceramic.Flattened bovine dentin was embedded in resin. The cement was inserted into a rubber mold (0.8 x 5 mm) that was placed between two polyvinyl chloride plastic films and placed over the flat dentin and light cured by Elipar Trilight-QTH (800 mW/cm2) or Ultra-Lumelight-emitting diode (LED 5; 1585 mW/cm2) over ceramic disks 1.4 or 2 mm thick. The specimens(n=6) were stored for 24 hours before Knoop hardness (KHN) was measured. The data were submitted to analysis of variance in a factorial split-plot design and Tukey's test (a=0.05).There was significant interaction among the study factors. In the groups cured by the QTHunit, an increase in ceramic thickness resulted in reduced cement hardness values at all depths, with the highest values always being found in the center (1.4 mm, 58.1; 2 mm, 50.1)and the lowest values at the bottom (1.4 mm,23.8; 2 mm, 20.2). When using the LED unit, the hardness values diminished with increased ceramic thickness only on the top (1.4 mm,51.5; 2 mm, 42.3). In the group with the 1.4-mm-thick disk, the LED curing unit resulted in similar values on the top (51.5) and center(51.9) and lower values on the bottom (24.2).However, when the cement was light cured through the 2-mm disk, the highest hardness value was obtained in the center (51.8), followed by the top (42.3) and bottom (19.9),results similar to those obtained with the QTH curing unit (center > top > bottom). The hardness values of the studied cement at different depths were dependent on the ceramic thickness but not on the light curing units used.


Assuntos
Cimentos de Resina/química , Silicatos de Alumínio/química , Animais , Bovinos , Lâmpadas de Polimerização Dentária/classificação , Porcelana Dentária/química , Dentina/ultraestrutura , Adesivos Dentinários/química , Dureza , Cura Luminosa de Adesivos Dentários/métodos , Teste de Materiais , Plásticos/química , Polimerização , Cloreto de Polivinila/química , Propriedades de Superfície , Temperatura , Fatores de Tempo
13.
Oper Dent ; 36(6): 670-7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21913859

RESUMO

The purpose of this study was to evaluate the biomechanical degradation of two nanofilled restorative materials (a resin-modified glass ionomer, Ketac N100 and a composite, Filtek Z350), compared with conventional materials (Vitremer and TPH Spectrum). Twenty specimens obtained from each material were divided into two storage groups (n=10): relative humidity (control) and Streptococcus mutans biofilm (biodegradation). After 7 days of storage, roughness values (Ra) and micrographs by scanning electron microscopy (SEM) were obtained. In a second experimental phase, the specimens previously subjected to biodegradation were fixed to the tooth-brushing device and abraded via toothbrushes, using dentifrice slurry (mechanical degradation). Next, these specimens were washed, dried, and reassessed by roughness and SEM. The data were submitted to repeated measures three-way analysis of variance (ANOVA) and Tukey tests (p<0.05). There was statistically significant interaction among factors: material, storage (humidity/biofilm), and abrasion (before/after). After biodegradation (S mutans biofilm storage), Ketac N100 presented the highest Ra values. Concerning bio plus mechanical challenge, TPH Spectrum, Ketac N100, and Vitremer presented the undesirable roughening of their surfaces, while the nano composite Filtek Z350 exhibited the best resistance to cumulative challenges proposed. The degraded aspect after biodegradation and the exposure of fillers after mechanical degradation were visualized in micrographs. This study demonstrated that the nanotechnology incorporated in restorative materials, as in composite resin and resin-modified glass ionomer, was important for the superior resistance to biomechanical degradation.


Assuntos
Resinas Compostas/química , Desgaste de Restauração Dentária , Cimentos de Ionômeros de Vidro/química , Nanoestruturas , Biofilmes , Biotransformação , Teste de Materiais , Microscopia Eletrônica de Varredura , Streptococcus mutans/metabolismo , Propriedades de Superfície
14.
Oper Dent ; 36(1): 43-51, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21488728

RESUMO

PURPOSE: This study evaluated the surface roughness, hydrophobicity and in situ dental biofilm associated with microfilled feldspar ceramics submitted to the different finishing and polishing procedures. METHODS AND MATERIALS: Samples were made according to the manufacturer's instructions and allocated to groups as follows: glaze (G1); glaze and diamond bur (G2); glaze, diamond bur and rubber tips (G3) and glaze, diamond bur, rubber tips and felt disks impregnated with a fine-aluminum oxide particle based paste (G4). Roughness was evaluated with a roughness analyzer (Ra). Hydrophobicity was determined by the contact angle of deionized water on samples. Biofilm was evaluated eight hours after formation in the oral environment using confocal laser-scanning microscopy (CLSM) and scanning-electron microscopy (SEM). RESULTS: Significant differences were found related to roughness (G1

Assuntos
Biofilmes , Placa Dentária/microbiologia , Polimento Dentário/métodos , Porcelana Dentária , Facetas Dentárias/microbiologia , Silicatos de Alumínio , Análise de Variância , Polimento Dentário/instrumentação , Porcelana Dentária/química , Humanos , Teste de Materiais , Microscopia Confocal , Microscopia Eletrônica de Varredura , Compostos de Potássio , Propriedades de Superfície , Molhabilidade
15.
Arch Oral Biol ; 53(11): 1023-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18675389

RESUMO

Studies have evaluated dental hard tissues characteristics from animal species in order to be used as a substitute for human teeth. The aim of this study was to evaluate the radiodensity and hardness of human and bovine enamel and dentin, varying bovine teeth age. Five specimens (1mm thick) were obtained from animals aged 20 (B20), 30 (B30), 38 (B38) and 48 (B48)months and from 20 to 30-years-old human third molars (H). The radiographic images were taken with a phosphor plaque digital system (Digora Optime). The radiodensity was obtained and Knoop hardness (KHN) was recorded (100g for 15s--5 indentations per specimen). Data were analyzed by one-way ANOVA following Tukey's HSD test and Dunnet's two-sided t-test. Radiodensity was similar within enamel groups, but bovine dentin presented higher radiodensity than human one regardless of age groups. Enamel-KHN showed differences between B20-B30 and B38-B48-H, and dentin-KHN was similar within all groups. Enamel was always more radiodense than dentin and also presented higher KHN (p=0.001). The use of bovine enamel or dentin should take into consideration the teeth age, but as a general rule it should be recommended to select older bovine teeth due to better chances to find greater similarity with human teeth.


Assuntos
Bovinos/fisiologia , Esmalte Dentário/fisiologia , Dentina/fisiologia , Adulto , Envelhecimento/fisiologia , Animais , Esmalte Dentário/diagnóstico por imagem , Esmalte Dentário/ultraestrutura , Dentina/diagnóstico por imagem , Dentina/ultraestrutura , Dureza , Testes de Dureza/métodos , Humanos , Microscopia Eletrônica de Varredura , Modelos Animais , Dente Serotino/diagnóstico por imagem , Dente Serotino/fisiologia , Dente Serotino/ultraestrutura , Radiografia Dentária/métodos , Especificidade da Espécie , Adulto Jovem
16.
J Clin Pediatr Dent ; 25(2): 137-41, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11314213

RESUMO

The use of disinfectants on the dentin surface contributes to superficial cleaning and removal of remaining microorganisms of the carious process. However, the effect of these agents on the adhesion of resin materials to the dentin surface of primary teeth has not been established. This study evaluated the dentin micromorphological effects due to the use of antimicrobial agents in the different depths of dentin. Twenty-five buccal surfaces of primary molars were prepared from the sectioned teeth, ground flat and polished with silicon carbide paper of different grits. The surfaces were treated with 32% phosphoric acid with benzalkonium chloride (Bisco), 35% phosphoric acid gel (3 M), 3% benzalkonium chloride solution by itself or 10% maleic acid. All agents were applied for 15 seconds on the dentin surface. The samples were washed with distilled water, dried and coated with gold for observation of the dentin surface with the scanning electron microscope. The samples were subdivided according to the dentin depth in upper, middle and lower areas. The following was observed: presence of smear layer, opening of the dentin tubules, and inter and intratubular dentin morphology. The effects of the antimicrobial agents were compared in the different depths of the dentin. The results demonstrated that the surface conditioned with 3% benzalkonium chloride solution presented few disclosed dentin tubules. The use of the 32% phosphoric acid with benzalkonium chloride completely removed the smear layer and increased the diameter of the dentin tubule openings. The 35% phosphoric acid totally exposed the tubules in the upper area of the analyzed surface but partially exposed them in the middle and lower areas. The 10% maleic acid totally removed the smear layer, left all the tubules opened and conditioned the intertubular dentin. It was concluded that in the different depths of the dentin surface, conditioning with 10% maleic acid in primary teeth showed the most consistent micromorphological characteristics compared to the other agents used in this study.


Assuntos
Anti-Infecciosos Locais/farmacologia , Dentina/efeitos dos fármacos , Dente Decíduo/efeitos dos fármacos , Condicionamento Ácido do Dente , Anti-Infecciosos Locais/administração & dosagem , Compostos de Benzalcônio/administração & dosagem , Compostos de Benzalcônio/farmacologia , Compostos Inorgânicos de Carbono , Criança , Colagem Dentária , Polimento Dentário , Dentina/ultraestrutura , Humanos , Maleatos/administração & dosagem , Maleatos/farmacologia , Microscopia Eletrônica de Varredura , Microtomia , Ácidos Fosfóricos/administração & dosagem , Ácidos Fosfóricos/farmacologia , Resinas Sintéticas/química , Compostos de Silício , Camada de Esfregaço , Tensoativos , Dente Decíduo/ultraestrutura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...