Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthodont Res ; 67(3): 384-391, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-36288959

RESUMO

PURPOSE: We aimed to evaluate the effectiveness of photoreactive 2-methacryloyloxyethyl phosphorylcholine (MPC) in inhibiting Candida albicans biofilm formation on polymethyl methacrylate (PMMA) and assess its mechanism and need for re-application by evaluating its interaction with salivary mucin and durability during temperature changes. METHODS: PMMA discs were used as specimens. The MPC coating was applied using the spray and cure technique for the treatment groups, whereas no coating was applied to the control. The MPC treatment (MT) groups were further differentiated based on the number of thermal cycles involved (0, 1000, 2500, and 5000). The optical density was measured to assess mucin adsorption (MA). Contact angle (CA) was calculated to evaluate surface hydrophilicity. The presence of MPC components on the PMMA surface was assessed using X-ray photoelectron spectroscopy (XPS). C. albicans biofilms were evaluated qualitatively (scanning electron microscope images) and quantitatively (colony-forming units (CFUs)). Statistical analysis was conducted using two-way analysis of variance and Tukey's multiple comparison test. RESULTS: MA rate and CA increased significantly in the MT groups, which exhibited significantly fewer CFUs and thinner biofilms than those of the control group. Based on the XPS, MA, and CFU evaluations, the durability and efficacy of the MPC coating were considered stable up to 2500 thermal cycles. Additionally, a significant interaction was observed between mucin concentration and MPC efficacy. CONCLUSIONS: The photoreactive MPC coating, which was resistant to temperature changes for approximately 3 months, effectively prevented C. albicans biofilm formation by modifying surface hydrophilicity and increasing mucin adsorption.


Assuntos
Resinas Acrílicas , Candida albicans , Resinas Acrílicas/química , Polímeros , Polimetil Metacrilato/farmacologia , Polimetil Metacrilato/química , Propriedades de Superfície , Biofilmes , Mucinas
2.
Dent J (Basel) ; 10(5)2022 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-35621528

RESUMO

Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use.

3.
Int J Implant Dent ; 7(1): 111, 2021 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-34773513

RESUMO

BACKGROUND: Implant-assisted removable partial dentures (IARPDs) have recently become popular, but little information is available on the treatment outcomes based on the Kennedy classification and attachment types. OBJECTIVE: The objective of this review was to evaluate the treatment outcomes of IARPD delivered for distal extension edentulous areas based on the differences in the Kennedy classification and attachment type. MATERIALS AND METHODS: English-language clinical studies on IARPD published between January 1980 and February 2020 were collected from MEDLINE (via PubMed), the Cochrane Library (via the Cochrane Central Register of Controlled Trials), Scopus online database, and manual searching. Two reviewers selected the articles based on pre-determined inclusion and exclusion criteria, followed by data extraction and analysis. RESULTS: Eighty-one studies were selected after evaluating the titles and abstracts of 2410 papers. Nineteen studies were finally included after the perusal of the full text. Fourteen studies focused on Class I, 4 studies investigated both Class I and II, and only 1 study was conducted on Kennedy's class II. Eight types of attachments were reported. The ball attachment was the most frequently used attachment, which was employed in 8 of the included studies. The implant survival rate ranged from 91 to 100%. The reported marginal bone loss ranged from 0.3 mm to 2.30 mm. The patient satisfaction was higher with IARPD than with conventional RPDs or that before treatment. The results of prosthetic complications were heterogeneous and inconclusive. CONCLUSION: IARPD exhibited favorable clinical outcomes when used as a replacement for distal extension edentulous areas. The comparison between the clinical outcomes of Kennedy's class I and II was inconclusive owing to the lack of studies focusing on Kennedy Class II alone. The stud attachment was the most commonly used type in IARPDs. Overall, the different attachment systems did not influence the implant survival rate and patient satisfaction. Further high-quality studies are needed to investigate the attachment systems used in IARPD.


Assuntos
Implantes Dentários , Prótese Parcial Removível , Prótese Dentária Fixada por Implante , Humanos , Satisfação do Paciente , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...