Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiology ; 249(1): 167-77, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18796675

RESUMO

PURPOSE: To introduce an educational intervention-specifically, a specialized training course-and perform a formative evaluation of the effect of the intervention on novice reader interpretation of computed tomography (CT) colonographic data. MATERIALS AND METHODS: The study was institutional review board approved. Ten normal and 50 abnormal cases, those of 60 patients with 93 polyps-61 polyps 6-9 mm in diameter and 32 polyps 10 mm or larger-were selected from a previously published trial. Seven novice readers underwent initial training that consisted of a 1-day course, reading assignments, a self-study computer module (with 61 limited data sets), observation of an expert interpreting three cases, and full interpretation of 10 cases with unblinding after each case. After training, the observers independently interpreted 60 cases by means of primary two-dimensional reading with unblinding after each case. For each case, the reading time and the location and maximal diameter of the polyp(s) were recorded. A t test was used to evaluate the observers' improvements, and empirical receiver operating characteristic (ROC) curves were constructed. RESULTS: By-patient sensitivities and specificities were determined for each observer. The lowest by-patient sensitivity at the 6 mm or larger polyp threshold was 86%, with 90% specificity. Four observers had 100% by-patient sensitivity at the 10 mm or larger polyp threshold, with 82%-97% specificity. For polyps 10 mm or larger, mean sensitivity and specificity were 98% and 92%, respectively. For the last 20 cases, the average interpretation time per case was 25 minutes. The range of areas under the ROC curve across observers was low: 0.86-0.95. CONCLUSION: In the described polyp-enriched cohort, novice CT colonographic data readers achieved high sensitivity and good specificity at formative evaluation of a comprehensive training program. Use of a similar comprehensive training method might reduce interreader variability in interpretation accuracy and be useful for reader certification.


Assuntos
Colonografia Tomográfica Computadorizada , Pólipos do Colo/diagnóstico por imagem , Educação Médica Continuada , Humanos , Sensibilidade e Especificidade , Ensino/métodos
2.
Radiol Clin North Am ; 45(3): 499-512, viii, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17601505

RESUMO

State-of-the-art multidetector row CT (MDCT) technology has revolutionized abdominal imaging. The ability of CT to determine if bowel obstruction is present, to localize the obstructive site, to determine degree of obstruction, to diagnose the presence of closed-loop obstruction, and to identify ischemia or perforation of the involved bowel is well established. This article illustrates the usefulness of MDCT in the evaluation of small bowel obstruction and related conditions in adults and emphasizes the benefits of advanced CT applications.


Assuntos
Obstrução Intestinal/diagnóstico , Intestino Delgado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Humanos , Intestino Delgado/patologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...