Sci Rep ; 12(1): 10445, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35729240

RESUMO

The optimization work of a newly proposed 20-in. photomultiplier tube based on dynode and microchannel plates (Dynode-MCP-PMT) are conducted in this paper. Three-dimensional models are developed in CST STUDIO SUITE to systematically investigate the effects of the size and bias voltage of the two focusing electrodes, dynode and the glass envelop handle based on the Finite Integral Technique and Monte Carlo method. Results predict that the collection efficiency and the transit time spread of the optimized design are substantially improved which are 100% and 3.7 ns.


Assuntos
Desenho de Equipamento , Eletrodos , Método de Monte Carlo