Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Indian J Orthop ; 52(6): 651-656, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30532307

RESUMO

BACKGROUND: Cervical pedicle screw fixation through posterior approach has shown greater cervical stability advantage. The cervical pedicle screw fixation technique through posterior approach is demanding. The key to the technique is the choice of point and angle of screw entrance. The angle of screw placement is variable. Morphometric measurements of the cervical pedicle are a prerequisite for individualized screw. CT imaging has become the most reliable and important means to obtain cervical pedicle's measurement data and morphology in vivo. This study explores the feasibility and application of precise in vivo measurements by multi-slice computed tomography (MSCT) for individualized cervical transpedicular screw placement at C3-C7 in Chinese healthy population. MATERIALS AND METHODS: 80 adults who underwent cervical examination by enhanced and nonenhanced computed tomography angiography, respectively, were selected and submitted to bone algorithm reconstruction for slice thickness and interval of 0.75 mm to acquire clear images and detailed bone structures. Simulation of individualized screw placement was performed with a 4.0 mm diameter screw with the help of postprocessing workstation. Pedicle transverse angle (PTA) and sagittal angle (PSA) were measured using the single- and double-line methods (analog nailing, 4.0 mm in diameter) in 160 pairs of C3-C7 pedicles, setting positive and negative values for cranial direction and foot side PSAs, respectively. Comparison of the measured change scope in PTA and PSA between the two methods was carried out; the range was defined as the error range. RESULTS: Significantly, different results (P < 0.05) were obtained between the single- and double-line methods in the error ranges of PTA and PSA in C3-C7 pedicles. Interestingly, the double-line method was better in simulating the actual needs of individualized nailing. The mean values of PTA and PSA were 42.9°, 45.5°, 42.4°, 37.1°, 29.0° and 8.4°, 5.0°, -4.0°, and -7.8°, -8.1°, respectively, with the double-line method. CONCLUSION: MSCT reconstruction techniques can determine the direction and required parameters for individualized screw placement. In addition, accurate in vivo measurements of PTA and PSA, particularly PSA, provide the orthopedic surgeon with theoretical guidance and reliable basis in screw placement.

2.
J Xray Sci Technol ; 24(6): 807-820, 2016 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-27612046

RESUMO

PURPOSE: To assess the application value of submillisievert coronary CT angiography (CCTA) in patients with a high heart rate (HR) acquired with adaptive prospective ECG-triggered sequence acquisition and iterative reconstruction on the secondary generation dual-source CT. MATERIALS AND METHODS: A total of 120 consecutive high-HR patients suspected with coronary artery disease underwent CCTA and invasive coronary angiography (ICA) within two weeks. Patients were randomly assigned into three groups: group A (n = 40), where the patients underwent retrospectively ECG-triggered acquisition CCTA at 100 kVp; group B (n = 40), where the patients received adaptive prospective ECG-triggered sequence acquisition at 100 kVp; and group C (n = 40), where the patients performed adaptive prospective ECG-triggered sequence acquisition at 80 kVp with iterative reconstruction. The mean CT values, signal noise ratios (SNR) and contrast noise ratios (CNR) in the ascending aorta and coronary arteries of the three groups were measured and compared. The image quality and radiation dose among the three groups were compared. The consistency of displaying the coronary stenosis of each group was assessed compared with the results of ICA as the gold standard. RESULTS: There was no significant difference in gender, age and body mass index (BMI) (all P > 0.05). The mean attenuations, SNRs and CNRs in the ascending aorta and coronary artery were not significantly different between group A and group B (P > 0.05). The mean attenuations of group C were significantly higher than group A and group B (P < 0.01), but the image noise and CNR were significantly lower in group C (P < 0.01). The number of appreciable segments among the three groups was not significantly different on a per-segment and per-vessel basis (P > 0.05). The subjective image quality among the three groups was not significantly different (P > 0.05). With the ICA result as a reference standard, there was good consistency in the evaluation of the coronary stenosis degree between CCTA and ICA (r > 0.75), as well as in the assessment of the coronary stenosis rate using the Bland- Altman analysis. The mean radiation dose in group B was half of that in group A. Moreover, the mean radiation dose in group C was less than one sixth of that in group A and less than 1 mSv (0.7±0.2 mSv). CONCLUSIONS: For patients with high HR, adaptive prospective ECG-triggered sequence acquisition on the FLASH dual-source CT results in equal image quality and half of the radiation dose reduction compared with retrospectively ECG-triggered spiral acquisition at the same tube voltage (100 kVp) and same R-R interval of exposure. In addition, adaptive prospective ECG-triggered sequence acquisition combined with low tube voltage and iterative reconstruction can further reduce the radiation dose to the submillisievert level without compromising image quality and the accuracy of assessing the coronary stenosis degree, and can be popularized as a routine technique.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Eletrocardiografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Adulto , Idoso , Calibragem , Estudos de Coortes , Simulação por Computador , Desenho de Equipamento , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
3.
Chin Med J (Engl) ; 128(12): 1636-42, 2015 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-26063366

RESUMO

BACKGROUND: To evaluate the utility of rabbit ladderlike model of radiation-induced lung injury (RILI) for the future investigation of computed tomography perfusion. METHODS: A total of 72 New Zealand rabbits were randomly divided into two groups: 36 rabbits in the test group were administered 25 Gy of single fractionated radiation to the whole lung of unilateral lung; 36 rabbits in the control group were sham-radiated. All rabbits were subsequently sacrificed at 1, 6, 12, 24, 48, 72 h, and 1, 2, 4, 8,1 6, 24 weeks after radiation, and then six specimens were extracted from the upper, middle and lower fields of the bilateral lungs. The pathological changes in these specimens were observed with light and electron microscopy; the expression of tumor necrosis factor-α (TNF-a) and transforming growth factor-ß1 (TGF-ß1) in local lung tissue was detected by immunohistochemistry. RESULTS: (1) Radiation-induced lung injury occurred in all rabbits in the test group. (2) Expression of TNF-a and TGF-ß1 at 1 h and 48 h after radiation, demonstrated a statistically significant difference between the test and control groups (each P < 0.05). (3) Evaluation by light microscopy demonstrated statistically significant differences between the two groups in the following parameters (each P < 0.05): thickness of alveolar wall, density of pulmonary interstitium area (1 h after radiation), number of fibroblasts and fibrocytes in interstitium (24 h after radiation). The test group metrics also correlated well with the time of postradiation. (4) Evaluation by electron microscopy demonstrated statistically significant differences in the relative amounts of collagen fibers at various time points postradiation in the test group (P < 0.005), with no significant differences in the control group (P > 0.05). At greater than 48 h postradiation the relative amount of collagen fibers in the test groups significantly differ from the control groups (each P < 0.05), correlating well with the time postradiation (r = 0.99318). CONCLUSIONS: A consistent and reliable rabbit model of RILI can be generated in gradient using 25 Gy of high-energy X-ray, which can simulate the development and evolution of RILI.


Assuntos
Lesão Pulmonar/etiologia , Lesões por Radiação/etiologia , Animais , Modelos Animais de Doenças , Feminino , Lesão Pulmonar/diagnóstico por imagem , Lesão Pulmonar/metabolismo , Masculino , Coelhos , Lesões por Radiação/diagnóstico por imagem , Lesões por Radiação/metabolismo , Radiografia , Fator de Crescimento Transformador beta1/metabolismo , Fator de Necrose Tumoral alfa/metabolismo , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...