Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Legal Med ; 136(3): 841-852, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35258670

RESUMO

OBJECTIVES: To assess the performance of knee MRI for forensic age prediction and classification for 12-, 14-, 16-, and 18-year thresholds. METHODS: The ossification stages of distal femoral epiphyses and proximal tibial epiphyses were assessed using an integrated staging system by Schmeling et al. and Kellinghaus et al. for knee 3.0T MRI with T1-weighted turbo spin-echo (T1-TSE) in sagittal orientation among 852 Chinese Han individuals (483 males and 369 females) aged 7-30 years. Regression models for age prediction were constructed and their performances were evaluated based on mean absolute deviation (MAD) values. In addition, the performances of age classification were assessed using receiver operating characteristic (ROC) analyses. RESULTS: The intra- and inter-observer agreement levels were very good (κ > 0.80). The complete fusion of those two types of epiphyses took place before 18.0 years in our study participants. The minimum MAD values were 2.51 years (distal femur) and 2.69 years (proximal tibia) in males, and 2.75 years (distal femur) and 2.87 years (proximal tibia) in females. The specificity values of constructed prediction models were all above 90% for the 12-, 14-, and 16-year thresholds, compared to the 74.8-84.6% for the 18-year threshold. Better performances of age prediction and classification were observed in males by distal femoral epiphyses. CONCLUSIONS: Ossification stages via 3.0T MRI of the knee with T1-TSE sequence using an integrated staging system could be a reliable noninvasive method for age prediction or for age classification for 12-, 14-, and 16-year thresholds, especially in males by distal femoral epiphyses. However, assessments based on the full bony fusion of the distal femoral epiphysis and proximal tibial epiphysis seemed not reliable for age classification for the 18-year threshold in the Chinese Han population.


Assuntos
Determinação da Idade pelo Esqueleto , Epífises , Determinação da Idade pelo Esqueleto/métodos , China , Epífises/diagnóstico por imagem , Feminino , Fêmur/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Osteogênese , Tíbia/diagnóstico por imagem
2.
Leg Med (Tokyo) ; 52: 101912, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34090258

RESUMO

Age estimation is an important topic of human identification in forensic practice, especially coming to biological samples in crime scene, such as blood, saliva, semen. As rate-limiting enzyme in Nucleotide excision repair (NER) that was associated with aging, Excision repair cross-complementation group 5 (ERCC5) was considered to be a candidate biomarker for individual age estimation. The ERCC5 mRNA and protein expression levels association with age have been demonstrated in our previous study. However, very little is known about relationship DNA-based quantification of ERCC5 with age. In this study, we detected ERCC5 level in peripheral blood from a Chinese Han population by SYBR qPCR assay to gain better insight into the quantitative relationship with age. The results showed ERCC5 level declined with individual age with a negative correlation(r = -0.8, R2 = 0.63, P < 0.001). The data model for age estimation based on ERCC5 level was Y = -31.352X + 14.436 ± 10.28 (Y: age, year; X: CqTBP-CqERCC5; standard error: year). The accuracy about the data model for age estimation was about 73.33%. The mean absolute difference (MAD) values were 8.22, 8.09 and 8.38 in total, male and female, respectively. Furthermore, ERCC5 quantification for age estimation was also applicable for stored blood samples under low temperature up to 6 months. It was suggested that the ERCC5 quantification was expected to be a valuable additional method for individual age estimation, especially in cases where traditional morphologic method is absent or inefficient in forensic practice.


Assuntos
Envelhecimento , Reparo do DNA , China , DNA , Feminino , Humanos , Masculino , RNA Mensageiro
3.
J Orthop Translat ; 23: 152-158, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32913707

RESUMO

AIM: Osteoporotic vertebral compressive fractures (VCFs) â€‹are known to be commonly missed in X-rays indicated for pulmonary or heart diseases. In this study, we investigated the underreporting status of VCF in back pain clinic patients when the spine was the focus of interest. MATERIALS AND METHODS: This is a retrospective analysis of 105 female cases (mean: 72 years, range: 55-93 years) from a tertiary hospital in China (facility A, FA). The patients with back and/or leg pain were referred for a spine X-ray. The images were retrieved and transferred to a central reading facility (facility B, FB), where images were double-read by two readers experienced in evaluating osteoporotic vertebral compressive deformity (VCD)/VCF. A qualitative VCD with <20%, 20-25%, 25-40%, and >40% vertebral body height loss was recorded as minimal, mild, moderate, and severe grades, respectively. A â€‹VCD coexisted with endplate/cortex fracture (ECF) was VCF. FB readings were considered as the reference. RESULTS: There were 34 true negative cases where FA and FB had a consensus. In 7 cases with minimal VCD, 3 cases with ECF, and 7 cases with minimal or mild VCFs, the FA readings were false negative. No standalone singular moderate or severe VCD/VCF in a patient was missed in FA's reports. In 25 FA reading positive cases with multiple VCFs, one VCF was missed in 8 cases, more than one VCF was missed in 15 cases, and one additional ECF was missed in 2 cases. In 14 cases, FA and FB had VCF number agreement, with the term 'vertebral fracture' was used appropriately in FA reports. In 15 cases, FA and FB had agreement in VCF number; however, the appropriate term 'vertebral fracture' was not used in FA reports; instead the terms of 'compressive change' or 'wedging change' were used. In most VCFs, severity grading was not given in FA. In 13 VCFs where grading was reported, all were marked as 'mild', including seven mild VCFs, five moderate VCFs, and even one severe VCF. CONCLUSION: Among the patients with VCD/VCF, the false negative rate among was 23.9% (17/71), but the missed cases were all minimal or mild grades. One or more VCFs were missed in 32.4% (23/71) of the cases with multiple VCFs. Appropriate severity grading was not reported for most cases. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The underreporting rate of osteoporotic vertebral compressive fracture in back pain clinic patients in a typical tertiary hospital setting in China compared favorably with literature reports. However, there is a general lack of awareness of vertebral endplate/cortex fracture sign and vertebral fracture severity grading, while minimal and mild VCD with endplate/cortex fracture may have clinical significance. Moreover, after one VCF is spotted in a patient, it is highly advisable to carefully check the whole spine so that multiple VCFs will not be missed.

4.
SLAS Technol ; 25(5): 474-483, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32292088

RESUMO

Liver vessel density can be evaluated by an imaging biomarker diffusion-derived vessel density (DDVD): DDVD/area(b0b2) = Sb0/ROIarea0 - Sb2/ROIarea2, where Sb0 and Sb2 refer to the liver signal when b is 0 or 2 (s/mm2); ROIarea0 and ROIarea2 refer to the region of interest (ROI) on b = 0 or 2 images; and Sb2 may be replaced by Sb15 (b = 15). This concept was validated in this study. Liver diffusion images were acquired at 1.5 T. For a scan-rescan repeatability study of six subjects, b values of 0 and 2 were used. The validation study was composed of 26 healthy volunteers and 19 consecutive suspected chronic viral hepatitis B patients, and diffusion images with b values of 0, 2, 15, 20, 30, 45, 50, 60, 80, 100, 200, 300, 600, and 800 were acquired. Four patients did not have liver fibrosis, and the rest were four stage 1, three stage 2, four stage 3, and one stage 4 patients, respectively. The intraclass correlation coefficient for repeatability was 0.994 for DDVD/area(Sb0Sb2) and 0.978 for DDVD/area(Sb0Sb15). In the validation study, DDVD/area(Sb0Sb2) and area(Sb0Sb15) were 14.80 ± 3.06 and 26.58 ± 3.97 for healthy volunteers, 10.51 ± 1.51 and 20.15 ± 2.21 for stage 1-2 fibrosis patients, and 9.42 ± 0.87 and 19.42 ± 1.89 for stage 3-4 fibrosis patients. For 16 patients where IVIM analysis was performed, a combination of DDVD/area, PF, and Dfast achieved the best differentiation for nonfibrotic livers and fibrotic livers. DDVD/area were weakly correlated with PF or Dfast. Both DDVD/area(Sb0Sb2) and area(Sb0Sb15) are useful imaging biomarkers to separate fibrotic and nonfibrotic livers, with fibrotic livers having lower measurements.


Assuntos
Biomarcadores/metabolismo , Imagem de Difusão por Ressonância Magnética , Hepatite B/complicações , Cirrose Hepática/diagnóstico , Cirrose Hepática/virologia , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Estudo de Prova de Conceito , Adulto , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
5.
Arch Osteoporos ; 15(1): 41, 2020 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-32144508

RESUMO

PURPOSE: Opportunities exist to detect osteoporotic vertebral deformities (VDs) on frontal radiograph (FR) indicated for lung or abdominal diseases, while literature have been mostly based on lateral radiograph (LR). This study analyzed the detectability of moderate and severe grades VD on FR. METHODS: There were 105 female cases (mean 72 years, range 55~93 year), who were referred for digital spine FR and LR with back and/or leg pain. The LR and FR were read, osteoporotic VDs with < 20%, 20-25%, 25-40%, and > 40% vertebral body height loss were recorded as minimal, mild, moderate, and severe grades, respectively. After a 10-month interval, only FRs were read again, and each vertebra was classified as (1) no notable VD, (2) with notable VD, and (3) ambiguous. The first reading was the reference, while the second reading was allowed to miss minimal/mild VCD and endplate/cortex fracture. RESULTS: Counting by subjects, for 98 cases, the two reading sessions had agreement, including 43 "true negative" cases and 55 true positive cases. There were two false positive cases, and five ambiguous cases. In total, 1286 vertebra were assessed, FR reading had 1126 vertebrae "true negative," 130 vertebrae true positive, one vertebra false negative, 3 vertebrae false positive, and 26 ambiguous vertebrae (65.4% being true negative and 34.6% being true positive). Most of the disagreements were associated with kyphosis or poor X-ray projection. Nineteen illustrative cases are presented graphically. CONCLUSION: Moderate and severe grades of VD are identifiable on FR as long as the involved vertebrae are clearly filmed.


Assuntos
Cifose/diagnóstico por imagem , Fraturas por Osteoporose/diagnóstico por imagem , Radiografia/métodos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Ilustração Médica , Pessoa de Meia-Idade , Coluna Vertebral/diagnóstico por imagem
6.
Quant Imaging Med Surg ; 9(3): 371-385, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31032185

RESUMO

BACKGROUND: Recent two studies reported that intravoxel incoherent motion (IVIM) analysis can separate healthy livers and viral hepatitis B (VHB) induced liver fibrosis. However, in these two studies the starting b value for bi-exponential decay analysis was b =10 and 15 s/mm2 respectively. The current study has two primary aims. The first is to further confirm the diagnostic value of IVIM in detecting liver fibrosis. The second is to test whether by sampling very low b value densely, then b =0 s/mm2 image could be included to improve IVIM's diagnostic performance. METHODS: This was a prospective study with data acquired at the Third Xiangya Hospital of Central South University, Changsha, China. Healthy volunteers and patients suspected of VHB induced liver fibrosis with liver biopsy performed, as well as hepatocellular carcinoma patients scheduled for surgery, were recruited. All the hepatocellular carcinoma patients had liver fibrosis. After exclusions based on pre-defined criteria for image data quality, for IVIM analysis this study included 20 healthy volunteers; 4 chronic VHB patients with biopsy showing no liver fibrosis; 11 stage-1 liver fibrosis patients, 10 stage-2 liver fibrosis patients, 2 stage-3 liver fibrosis patients, and 5 stage-4 liver fibrosis patients. In the liver fibrosis patients, 1, 19, and 8 cases had inflammation grade-0, grade-1, and grade-2 respectively. The reference IVIM bi-exponential decay curve fitting analysis was segmented fitting performed with b =2 s/mm2 image as the starting point and a threshold-b of 60 s/mm2. This reference fitting method was compared with threshold-b of 40 s/mm2, full fitting, fitting starting from b =0, 5, and 10 s/mm2 respectively. The potential correlation between IVIM readouts and liver function was assessed for the liver fibrosis patients. RESULTS: Based on the smaller coefficient of variation (CoV) for the volunteer group and the smaller patient/volunteer ratios [= (mean measurement for patient groups)/(mean measurement for healthy volunteers)], the comparison of fitting methods favored the reference approach starting from b =2 s/mm2 with a threshold-b of 60 s/mm2. The IVIM measures of four patients without liver fibrosis resembled those of healthy subjects. PF offered the best diagnostic value for separating healthy livers and fibrotic livers, and a threshold of PF =0.1406 separated all fibrotic livers and healthy livers with an exception of one hepatocellular carcinoma patient (fibrosis grade-2/inflammation grade-2). The correlation between fibrosis grading and inflammation grading was weakly positive; while compared with fibrotic livers with inflammation grade-1, fibrotic livers with inflammation grade-2 showed a trend of higher Dfast. A weak correlation is shown with lower PF and lower Dfast associated with lower total protein, lower albumin; higher alanine transaminase, higher aspartate transaminase; higher total bilirubin, and higher direct bilirubin. CONCLUSIONS: Segmented-fitting with threshold-b =60 s/mm2 and starting from non-zero very low b value outperforms other methods. IVIM has high sensitivity in detecting liver fibrosis, and PF and Dfast have potential correlation with serum liver function biomarkers. IVIM measures and liver fibrosis grading are not in a linear relationship.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...