Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Zhejiang Univ Sci B ; 25(2): 168-180, 2024 Feb 15.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38303499

RESUMO

Energy metabolism is fundamental for life. It encompasses the utilization of carbohydrates, lipids, and proteins for internal processes, while aberrant energy metabolism is implicated in many diseases. In the present study, using three-dimensional (3D) printing from polycarbonate via fused deposition modeling, we propose a multi-nuclear radiofrequency (RF) coil design with integrated 1H birdcage and interchangeable X-nuclei (2H, 13C, 23Na, and 31P) single-loop coils for magnetic resonance imaging (MRI)/magnetic resonance spectroscopy (MRS). The single-loop coil for each nucleus attaches to an arc bracket that slides unrestrictedly along the birdcage coil inner surface, enabling convenient switching among various nuclei and animal handling. Compared to a commercial 1H birdcage coil, the proposed 1H birdcage coil exhibited superior signal-excitation homogeneity and imaging signal-to-noise ratio (SNR). For X-nuclei study, prominent peaks in spectroscopy for phantom solutions showed excellent SNR, and the static and dynamic peaks of in vivo spectroscopy validated the efficacy of the coil design in structural imaging and energy metabolism detection simultaneously.


Assuntos
Imageamento por Ressonância Magnética , Prótons , Animais , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-Ruído , Desenho de Equipamento
2.
NMR Biomed ; 37(2): e5049, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37767723

RESUMO

Magnetic resonance imaging (MRI)/magnetic resonance spectroscopy (MRS) employing proton nuclear resonance has emerged as a pivotal modality in clinical diagnostics and fundamental research. Nonetheless, the scope of MRI/MRS extends beyond protons, encompassing nonproton nuclei that offer enhanced metabolic insights. A notable example is phosphorus-31 (31 P) MRS, which provides valuable information on energy metabolites within the skeletal muscle and cardiac tissues of individuals affected by diabetes. This study introduces a novel double-tuned coil tailored for 1 H and 31 P frequencies, specifically designed for investigating cardiac metabolism in rabbits. The proposed coil design incorporates a butterfly-like coil for 31 P transmission, a four-channel array for 31 P reception, and an eight-channel array for 1 H reception, all strategically arranged on a body-conformal elliptic cylinder. To assess the performance of the double-tuned coil, a comprehensive evaluation encompassing simulations and experimental investigations was conducted. The simulation results demonstrated that the proposed 31 P transmit design achieved acceptable homogeneity and exhibited comparable transmit efficiency on par with a band-pass birdcage coil. In vivo experiments further substantiated the coil's efficacy, revealing that the rabbit with experimentally induced diabetes exhibited a lower phosphocreatine/adenosine triphosphate ratio compared with its normal counterpart. These findings emphasize the potential of the proposed coil design as a promising tool for investigating the therapeutic effects of novel diabetes drugs within the context of animal experimentation. Its capability to provide detailed metabolic information establishes it as an indispensable asset within this realm of research.


Assuntos
Diabetes Mellitus , Imageamento por Ressonância Magnética , Animais , Coelhos , Imageamento por Ressonância Magnética/métodos , Prótons , Desenho de Equipamento , Espectroscopia de Ressonância Magnética/métodos , Imagens de Fantasmas
3.
Magn Reson Imaging ; 102: 179-183, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37356599

RESUMO

Combining multimodal approaches with functional magnetic resonance imaging (fMRI) has catapulted the research on brain circuitries of non-human primates (NHPs) into a new era. However, many studies are constrained by a lack of appropriate RF coils. In this study, a single loop transmit and 16-channel receive array coil was constructed for brain imaging of macaques at 7 Tesla (7 T). The 16 receive channels were mounted on a 3D-printed helmet-shaped form closely fitting the macaque head, with fourteen openings arranged for multimodal devices around the cortical regions. Coil performance was evaluated by quantifying and comparing signal-to-noise ratio (SNR) maps, noise correlations, g-factor maps and flip-angle maps with a 28-channel commercial knee coil. The in vivo results suggested that the macaque coil has higher SNR in cortical regions and better acceleration ability in parallel imaging, which may benefit revealing mesoscale organizations in the brain.


Assuntos
Encéfalo , Macaca , Animais , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cabeça , Razão Sinal-Ruído , Neuroimagem/métodos , Imagens de Fantasmas , Desenho de Equipamento
4.
Neuroimage ; 276: 120185, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37244320

RESUMO

OBJECTIVE: Blood-oxygen-level-dependent functional MRI allows to investigte neural activities and connectivity. While the non-human primate plays an essential role in neuroscience research, multimodal methods combining functional MRI with other neuroimaging and neuromodulation enable us to understand the brain network at multiple scales. APPROACH: In this study, a tight-fitting helmet-shape receive array with a single transmit loop for anesthetized macaque brain MRI at 7T was fabricated with four openings constructed in the coil housing to accommodate multimodal devices, and the coil performance was quantitatively evaluated and compared to a commercial knee coil. In addition, experiments over three macaques with infrared neural stimulation (INS), focused ultrasound stimulation (FUS), and transcranial direct current stimulation (tDCS) were conducted. MAIN RESULTS: The RF coil showed higher transmit efficiency, comparable homogeneity, improved SNR and enlarged signal coverage over the macaque brain. Infrared neural stimulation was applied to the amygdala in deep brain region, and activations in stimulation sites and connected sites were detected, with the connectivity consistent with anatomical information. Focused ultrasound stimulation was applied to the left visual cortex, and activations were acquired along the ultrasound traveling path, with all time course curves consistent with pre-designed paradigms. The existence of transcranial direct current stimulation electrodes brought no interference to the RF system, as evidenced through high-resolution MPRAGE structure images. SIGNIFICANCE: This pilot study reveals the feasibility for brain investigation at multiple spatiotemporal scales, which may advance our understanding in dynamic brain networks.


Assuntos
Estimulação Transcraniana por Corrente Contínua , Animais , Haplorrinos , Projetos Piloto , Imageamento por Ressonância Magnética , Neuroimagem , Encéfalo/diagnóstico por imagem , Macaca , Desenho de Equipamento , Imagens de Fantasmas , Ondas de Rádio , Razão Sinal-Ruído
5.
Phys Med Biol ; 67(19)2022 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-36067784

RESUMO

Objective. Improving the local uniformity ofB1+field for awake monkey brain magnetic resonance imaging (MRI) at ultra-high fields while facilitating convenient placement and fixation of MRI-compatible multimodal devices for neuroscience study, can eventually advance our understanding of the primate's brain organization.Approach. A group of single-channel RF coils including conventional loop coils and loopole coils sharing the same size and shape were designed for comparison; their performance as the transmit coil was quantitatively evaluated through a series of numerical electromagnetic (EM) simulations, and further verified by using 7T MRI over a saline phantom and a monkeyin vivo. Main results. Compared to conventional loop coils, the optimized loopole coil brought up to 23.5%B1+uniformity improvement for monkey brain imaging in EM simulations, and this performance was further verified over monkey brain imaging at 7Tin vivo. Importantly, we have systematically explored the underlying mechanism regarding the relationship between loopole coils' current density distribution andB1+uniformity, observing that it can be approximated as a sinusoidal curve.Significance. The proposed loopole coil design can improve the imaging quality in awake and behaving monkeys, thus benefiting advanced brain research at UHF.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Desenho de Equipamento , Haplorrinos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
6.
IEEE Trans Biomed Eng ; 68(5): 1611-1618, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32991277

RESUMO

OBJECTIVE: The purpose of the present study was to fabricate a novel RF coil exclusively for visualizing submillimeter tissue structure and probing neuronal activity in cerebral cortex over anesthetized and awake animals on 7T human scanners. METHODS: A novel RF coil design has been proposed for visualizing submillimeter tissue structure and probing neuronal activity in cerebral cortex over anesthetized and awake animals on 7T human scanners: a local transmit coil was utilized to save space for auxiliary device installation; 16 receive-only loops were densely arranged over a 5 cm-diameter circular area, with a diameter of 1.3 cm for each loop. RESULTS: In anesthetized macaque experiments, 60 µm T2*-weighted images were successfully obtained with cortical gyri and sulci exquisitely visualized; over awake macaques, bilateral activations of visual areas including V1, V2, V4, and MST were distinctly detected at 1 mm; over the cat, robust activations were recorded in areas 17 and 18 (V1 and V2) as well as in their connected area of lateral geniculate nucleus (LGN) at 0.3 mm resolution. CONCLUSION: The promising brain imaging results along with flexibility in various size use of the presented design can be an effective and maneuverable solution to take one step close towards mesoscale cortical-related imaging. SIGNIFICANCE: High-spatial-resolution brain imaging over large animals by using ultra-high-field (UHF) MRI will be helpful to understand and reveal functional brain organizations and the underlying mechanism in diseases.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Encéfalo , Gatos , Córtex Cerebral/diagnóstico por imagem , Humanos , Macaca
7.
Magn Reson Imaging ; 68: 167-172, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32081631

RESUMO

Non-human primates (NHPs) are vital models for neuroscience research. These animals have been widely used in behavioral, electrophysiological, molecular, and more recently, multimodal neuroimaging and neuro-engineering studies. Several RF coil arrays have been designed for functional, high-resolution brain magnetic resonance imaging (MRI), but few have been designed to accommodate multimodal devices. In the present study, a 16-channel array coil was constructed for brain imaging of macaques at 3 Tesla (3 T). To construct this coil, a close-fitting helmet-shaped form was designed to host 16 coil loops for whole-brain coverage. This assembly is mountable onto stereotaxic head frame bars, and the coil functions while the monkey is in the sphinx position with a clear line of vision of stimuli presented from outside of the MRI system. In addition, 4 openings were allocated in the coil housing, allowing multimodal devices to directly access visual cortical regions such as V1-V4 and MT. Coil performance was evaluated in an anesthetized macaque by quantifying and comparing signal-to-noise ratios (SNRs), noise correlations, and g-factor maps to a vendor-supplied human pediatric coil frequently used for NHP MRI. The result from in vivo experiments showed that the NHP coil was well-decoupled, had higher SNRs in cortical regions, and improved data acquisition acceleration capability compared with a vendor-supplied human pediatric coil that has been frequently used in macaque MRI studies. Furthermore, whole-brain anatomic imaging, diffusion tensor imaging and functional brain imaging have also been conducted: the details of brain anatomical structure, such as cerebellum and brainstem, can be clearly visualized in T2-SPACE images; b0 SNR calculated from b0 maps was higher than the human pediatric coil in all regions of interest (ROIs); the time-course SNR (tSNR) map calculated for GRE-EPI images demonstrates that the presented coil can be used for high-resolution functional imaging at 3 T.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Tensor de Difusão , Imageamento por Ressonância Magnética , Neuroimagem , Aceleração , Algoritmos , Animais , Anisotropia , Tronco Encefálico/diagnóstico por imagem , Haplorrinos , Cabeça , Imageamento Tridimensional , Macaca , Masculino , Ondas de Rádio , Razão Sinal-Ruído , Córtex Visual/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...