J Thorac Cardiovasc Surg ; 130(2): 520-7, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16077422

RESUMO

BACKGROUND: It was hypothesized that native heart valves function as if they were simple tubes with sides that collapse when external pressure is applied. Because "form follows function," this hypothesis could theoretically be confirmed by implanting a simple tube into the anatomic position of any native heart valve and documenting that under the same anatomic constraints and physiologic conditions as the native valve, the tube would assume the form of that native valve. If the hypothesis were thus proved, it would follow that a tissue valve based on a tubular design would have superior flow dynamics and stress distribution and would therefore be expected to outlast currently available tissue valves. Such a tubular tissue valve, the 3F Aortic Bioprosthesis (3F Therapeutics, Inc, Lake Forest, Calif) was designed and tested in vitro against a commercially available stentless aortic bioprosthesis. METHODS: With the use of state-of-the-art testing equipment, some of which had to be developed especially to test this truly stentless bioprosthesis in vitro, transvalvular gradients, effective orifice areas, degree of transvalvular laminar flow, finite element analysis of the distribution of leaflet stress, and accelerated wear testing for long-term durability were evaluated for the new 3F Aortic Bioprosthesis in comparison with the St Jude Medical Toronto SPV aortic bioprosthesis (St Jude Medical, Inc, St Paul, Minn). RESULTS: The valve gradients were lower and the effective orifice areas were greater for the 3F Aortic Bioprosthesis at all valve sizes and under all test conditions, including cardiac outputs ranging from 2.0 to 7.0 L/min, mean perfusion pressures from 40 to 200 mm Hg, and aortic compliances of 4% and 16%. The transvalvular flow across the 3F Aortic Bioprosthesis in vitro was qualitatively smooth, with a minimum of surrounding vortices. Maximum stress occurred in the belly of the leaflets of the 3F Aortic Bioprosthesis, with minimum stress at the commissural posts. The 3F Aortic Bioprosthesis was superior to the Toronto SPV valve in accelerated wear tests. CONCLUSIONS: These in vitro studies show that a tissue aortic valve designed on the basis of the proved engineering principle that form follows function has better hemodynamics, flow dynamics, stress distribution, and durability when compared under identical in vitro conditions with an excellent commercially available tissue aortic valve.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Fenômenos Biomecânicos , Técnicas In Vitro , Modelos Cardiovasculares , Desenho de Prótese
3.
J Bacteriol ; 183(10): 3098-107, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11325938

RESUMO

The yeast Yarrowia lipolytica is distantly related to Saccharomyces cerevisiae, can be genetically modified, and can grow in both haploid and diploid states in either yeast, pseudomycelial, or mycelial forms, depending on environmental conditions. Previous results have indicated that the STE and RIM pathways, which mediate cellular switching in other dimorphic yeasts, are not required for Y. lipolytica morphogenesis. To identify the pathways involved in morphogenesis, we mutagenized a wild-type strain of Y. lipolytica with a Tn3 derivative. We isolated eight tagged mutants, entirely defective in hyphal formation, from a total of 40,000 mutants and identified seven genes homologous to S. cerevisiae CDC25, RAS2, BUD6, KEX2, GPI7, SNF5, and PPH21. We analyzed their abilities to invade agar and to form pseudomycelium or hyphae under inducing conditions and their sensitivity to temperature and to Calcofluor white. Chitin staining was used to detect defects in their cell walls. Our results indicate that a functional Ras-cyclic AMP pathway is required for the formation of hyphae in Y. lipolytica and that perturbations in the processing of extracellular, possibly parietal, proteins result in morphogenetic defects.


Assuntos
Genes Fúngicos/genética , Proteínas de Saccharomyces cerevisiae , Leveduras/crescimento & desenvolvimento , Leveduras/genética , Proteínas de Ciclo Celular/genética , Proteínas de Ciclo Celular/metabolismo , Elementos de DNA Transponíveis , Proteínas de Ligação a DNA/genética , Proteínas de Ligação a DNA/metabolismo , Proteínas Fúngicas/genética , Proteínas Fúngicas/metabolismo , Regulação Fúngica da Expressão Gênica , Proteínas de Homeodomínio/genética , Proteínas de Homeodomínio/metabolismo , Proteínas dos Microfilamentos/genética , Proteínas dos Microfilamentos/metabolismo , Dados de Sequência Molecular , Morfogênese/genética , Mutagênese Insercional , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo , Proteínas ras/genética , Proteínas ras/metabolismo , ras-GRF1/genética , ras-GRF1/metabolismo
4.
Int J Occup Environ Health ; 6(4): 312-7, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11114124

RESUMO

The author describes the chain of frustrated attempts to regulate the use of the toxic pesticide endosulfan in the Philippines in the face of opposition from its internationally powerful manufacturer. Risk assessment, although purportedly a science-based system to protect public health and the environment, has failed to do so, particularly in vulnerable third-world countries. The precautionary principle, based on preventing risk rather than assessing established risk, holds hope for resolution of the problem.


Assuntos
Indústria Química , Endossulfano , Saúde Ambiental/legislação & jurisprudência , Hidrocarbonetos Clorados , Inseticidas , Medição de Risco , Animais , Países em Desenvolvimento , Ecossistema , Endossulfano/efeitos adversos , Feminino , Contaminação de Alimentos , Humanos , Inseticidas/efeitos adversos , Masculino , Camundongos , Neoplasias/induzido quimicamente , Filipinas , Intoxicação/mortalidade , Política , Revelação da Verdade
8.
Ann Biomed Eng ; 23(6): 750-9, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8572425

RESUMO

In vitro experiment was performed on a stented bovine jugular vein valve (VV, 14 mm I.D. x 2 cm long) and a stentless bovine jugular vein valve conduit (10 mm I.D. x 6 cm long) in a hydraulic flow loop with a downstream oscillatory pressure source to mimic respiratory changes. Simultaneous measurements were made on the valve opening area, conduit and sinus diameter changes using a specially designed laser optic system. Visualization of flow fields both proximal and distal to the venous valve, and the valve opening area were simultaneously recorded by using two video cameras. Laser Doppler anemometer surveys were made at three cross sections: the valve inlet, the valve exist, and 2 cm downstream of the venous valve to quantity flow reflux at valve closure. The experiment confirmed that the VV is a pressure-operated rather than a flow-driven device and that little or no reflux is needed to close the valve completely. The experiment further demonstrated that the VV sinus expands rapidly against back pressure, a critical character to consider in venous prosthesis design.


Assuntos
Hemorreologia , Modelos Cardiovasculares , Veias/fisiologia , Animais , Velocidade do Fluxo Sanguíneo , Prótese Vascular , Bovinos , Complacência (Medida de Distensibilidade) , Hemodinâmica/fisiologia , Humanos , Técnicas In Vitro , Veias Jugulares , Fluxometria por Laser-Doppler , Desenho de Prótese
9.
Bol Asoc Med P R ; 87(7-9): 130-4, 1995.
Artigo em Espanhol | MEDLINE | ID: mdl-8703267

RESUMO

UNLABELLED: Radical prostatectomy has become the gold standard treatment for localized prostate cancer. With the introduction of Laparoscopy Lymphadenectomy for Staging of Prostate Cancer in 1991, interest in the perineal approach to radical prostatectomy has been renewed. Historically, the perineal approach has proven to be less morbid than the retropubic counterpart. Herein, the authors report their experience with 98 male patients with clinically localized T2B (or less) Cancer of the Prostate who underwent Laparoscopic Lymphadenectomy of which 83, subsequently, had a radical perineal prostatectomy. The mean follow up of this group of patients was 16.5 months. Clinicopathological results are discussed and compared with the results of radical retropubic prostatectomy in the literature. IN CONCLUSION: (1) laparoscopic lymphadenectomy with radical perineal prostatectomy are less morbid, with a faster recovery rate than the standard radical retropubic prostatectomy approach. (2) as better non-surgical methods evolve in predicting the status of the pelvic lymph nodes, reserving laparoscopic lymphadenectomy for patients with high risk of developing lymph nodes' metastasis, the perineal prostatectomy and laparoscopic lymph node dissection are becoming the state of the art treatment in patients with localized prostate cancer.


Assuntos
Laparoscopia , Excisão de Linfonodo/métodos , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Idoso , Estudos de Avaliação como Assunto , Seguimentos , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
10.
ASAIO J ; 41(1): 89-94, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7727828

RESUMO

Suboptimal hemodynamic performance, tissue calcification, and limitation in long-term durability have been encountered clinically after aortic valve replacement with currently available bioprostheses. It is believed that some of these problems may be caused, directly or indirectly, by the stents of the bioprostheses. To address these deficiencies, the authors undertook the development of the Edwards Prima Stentless Bioprosthesis. This study was designed to evaluate the hemodynamic performance of the Edwards Prima Stentless Bioprosthesis in a pulse duplicator system. The stented Carpentier-Edwards Porcine Bioprosthesis (Baxter Healthcare Corp., Irvine, CA), which has been used in United States clinics for more than 10 years, was used as a control device. The flow fields in the vicinity of the test bioprostheses were inspected with color Doppler flow mapping. The transvalvular pressure gradients were measured invasively with a catheter and calculated with the Doppler determined velocity using a simplified Bernoulli equation. Additionally, the leakage volumes were determined with an electromagnetic flowmeter. In the Doppler flow mapping study, during systole, a central flow was observed distal to the stentless and stented bioprostheses. The central flow distal to the stentless bioprosthesis was broader than that observed distal to its stented counterpart. During diastole, no regurgitation was detected by color Doppler flow mapping in either the stentless or stented groups. The Doppler determined transvalvular pressure gradients correlated well with those measured by catheter (r = 0.990). Moreover, it was learned that the transvalvular pressure gradients of the stentless bioprosthesis were less than those of its stented counterpart, especially for the smaller sizes.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Bioprótese/normas , Pressão Sanguínea/fisiologia , Próteses Valvulares Cardíacas/normas , Animais , Valva Aórtica/fisiologia , Insuficiência da Valva Aórtica/fisiopatologia , Materiais Biocompatíveis , Calcinose/etiologia , Débito Cardíaco/fisiologia , Ecocardiografia Doppler em Cores , Hemodinâmica , Modelos Lineares , Fluxo Pulsátil/fisiologia , Reologia , Stents/efeitos adversos , Suínos , Gravação de Videoteipe
11.
Med Eng Phys ; 16(6): 458-64, 1994 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7858776

RESUMO

The closing motion of the occluder leaflets in bileaflet type mechanical heart valves (MHV) was monitored with a laser sweeping technique. The angular displacements of the leaflets were registered with precision of 0.2 microsecond steps. Experimental measurements were made using five 29 mm Edwards-Duromedics including three original specification (EDOS) and two modified specification (EDMS), and two 29 mm St Jude Medical MHVs. The testing valve was installed in the mitral position of a physiologic pulsatile mock circulatory flow loop using water-glycerine solution as the testing fluid. Each valve was tested by: (1) direct mounting the valve on metal washers, and (2) mounting the valve with its sewing ring. Experiments were carried out at pulse rates of 70, 90, and 120 beats min-1, with the corresponding cardiac output of 5, 6, and 7.5 litres min-1, and maximum left ventricular pressure gradients (dp/dt) of 1,800, 3,000 and 5,600 mm Hg s-1, respectively. The maximum leaflet closing velocity of each of the tested valve types are presented. The difference in leaflet closing movements between the direct rigid mounting and the sewing ring mounting are discussed. The details of the laser sweeping technique are presented.


Assuntos
Velocidade do Fluxo Sanguíneo , Próteses Valvulares Cardíacas/normas , Fenômenos Biomecânicos , Pressão Sanguínea , Débito Cardíaco , Próteses Valvulares Cardíacas/classificação , Humanos , Fluxometria por Laser-Doppler , Teste de Materiais , Valva Mitral , Modelos Cardiovasculares , Fluxo Pulsátil , Rotação , Processamento de Sinais Assistido por Computador
12.
J Appl Biomater ; 5(2): 159-62, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-10147176

RESUMO

Concerns with the currently available bioprostheses are calcification, long-term durability, and suboptimal hemodynamic performance. It is well known that these concerns are all more or less related to the cross-linking reagent, glutaraldehyde or formaldehyde, used in fixing bioprostheses. To address these concerns, we undertook the development of a porcine bioprosthesis fixed with a polyepoxy compound. In the development of this polyepoxy compound valve, it was found that the porcine leaflets fixed with polyepoxy compound were softer and more pliable than those fixed with glutaraldehyde. In this study, a special microtoming technique was developed to section the biological tissue so that the fixation uniformity in distinct layers of porcine aortic wall could be characterized. The fixation index and the denaturation temperature measurements in distinct layers of aortic walls showed that the cross-linking density was uniform throughout the entire aortic wall for the polyepoxy compound fixed porcine valve. It was also noted that the fixation index of the polyepoxy compound fixed aortic wall (91.5 +/- 0.5, n = 3) was not significantly different from that of its valvular leaflet (90.6 +/- 0.8, n = 3). Similarly, the denaturation temperature of the polyepoxy compound fixed aortic wall (80.4 +/- 0.9 degrees C, n = 5) was statistically comparable to that of its valvular leaflet (79.0 +/- 0.5 degrees C, n = 5). The results of this study indicated that polyepoxy compound can adequately fix the entire porcine aortic wall as well as its valvular leaflets.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Bioprótese , Compostos de Epóxi/química , Próteses Valvulares Cardíacas/instrumentação , Animais , Calcinose , Formaldeído , Glutaral/química , Humanos , Teste de Materiais , Desenho de Prótese , Ovinos , Fixação de Tecidos/métodos
13.
J Biomed Mater Res ; 28(6): 677-84, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8071378

RESUMO

Collagen from a native tissue is fixed with a polyepoxy compound (PC) for use as a new biologic prosthetic material. Prior studies have shown that this biomaterial has comparable properties with collagen fixed with glutaraldehyde (GA), and thus has great promise for biomedical applications. A prior kinetic study indicated that the reaction between the functional groups of collagen and the multifunctional epoxy EX-313 is a 2.5th-order reaction. The purpose of this study was to understand the mechanism of the amino acid-PC reactions in a fixation process. Bovine arteries were fixed with a monofunctional PC (EX-131) and a multifunctional PC (EX-313) as a function of fixation time. A sequential fixation with a second fixative was used to identify the available remaining reactive sites from a prior fixation. The denaturation temperature (Td) was measured on each sample. Because the denaturation temperature is a direct indication of crosslinking of individual amino acids with the fixative, the increase in Td of a subsequent fixation may be indicative of the available remaining amino acids. The fixation index was measured on each sample to reflect the increase of fixation completion in a sequential fixation process. The fixation index and crosslink data also revealed that the reactive amino acids for EX-131 and EX-313 may not be exactly the same. The data in this study suggest that a monofunctional fixative can pre-react with the amino acids of collagen to effectively block further fixation of collagen with a second fixative. This amino acid masking may be associated with collagen branching. Collagen branching and its effect on denaturation temperature are described.


Assuntos
Bioprótese , Compostos de Epóxi , Fixadores , Polipropilenos , Animais , Prótese Vascular , Bovinos , Colágeno/química , Reagentes de Ligações Cruzadas , Técnicas In Vitro , Teste de Materiais , Artérias Torácicas/química
14.
ASAIO J ; 40(2): 192-8, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-8003758

RESUMO

Concerns with currently available bioprostheses are calcification, long-term durability, and functional and hemodynamic performance. It has been well known that these concerns are all more or less related to the fixatives, glutaraldehyde or formaldehyde, used in preserving bioprostheses. To address these concerns, we undertook the development of a porcine bioprosthesis fixed with an epoxy compound. It was discovered that the porcine leaflets fixed with the epoxy compound appeared more natural than those preserved with glutaraldehyde. The performance of this newly developed epoxy compound bioprosthesis (three samples) was evaluated in a juvenile sheep model. The results were compared to those of its glutaraldehyde counterpart (three samples). Two-dimensional echocardiographic inspection of the valvular leaflet motion indicated that the epoxy compound leaflets were more pliable than their glutaraldehyde counterparts. In addition, the epoxy compound valve appeared to open more widely than the glutaraldehyde valve. Color Doppler flow mapping demonstrated that the blood flow distal to the epoxy compound valve was slightly broader than that observed distal to the glutaraldehyde valve. Moreover, at retrieval, less calcium and pannus ingrowth were observed in the epoxy compound valve than its glutaraldehyde counterpart. The results of this preliminary evaluation indicated that the performance of this newly developed epoxy compound valve was at least equivalent to its glutaraldehyde counterpart, if not better.


Assuntos
Materiais Biocompatíveis , Bioprótese , Compostos de Epóxi , Próteses Valvulares Cardíacas , Animais , Ecocardiografia Doppler , Valvas Cardíacas/diagnóstico por imagem , Hemodinâmica/fisiologia , Desenho de Prótese , Fluxo Pulsátil , Reologia , Ovinos , Suínos
15.
J Heart Valve Dis ; 3(1): 49-52, 1994 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8162215

RESUMO

A novel hybrid methodology for prediction of valve related complications in patients with implanted artificial heart valves is discussed. Artificial neural networks provided a mechanism for prediction of postoperative valve-related deaths based on preoperative patient information and valve parameters. Then bootstrap methodology was applied for estimating prediction errors and maximizing prediction accuracy. Data from a clinical trial with 10 years of follow-up on 789 patients implanted with Carpentier-Edwards Pericardial Bioprosthesis were used. A random subset of the data was reserved for validation of the final outcome. The remaining patients' records were repeatedly divided into two groups, using resampling strategy provided by the bootstrap methodology. One of the groups was used for training the neural net and the other one for testing the trained network and determining error rates. Patient information, such as sex, age, NYHA class and anticoagulation therapy, as well as valve parameters, such as size and the date of implant were used as the network inputs. Calculated error rates were then used for assessing the distribution of the error, further optimization of the neural network, and constructing confidence intervals for the error rates. Thus, reliable statistical estimation was obtained on the prediction accuracy. Additionally this new hybrid methodology allowed us to optimize the neural network even further, raising the accuracy of prediction to 78%.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas/mortalidade , Redes Neurais de Computação , Feminino , Seguimentos , Previsões , Humanos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Risco , Resultado do Tratamento
16.
J Vasc Surg ; 18(4): 577-84; discussion 584-6, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8411465

RESUMO

PURPOSE: A prosthetic venous valve must be biocompatible and nonthrombogenic and function in the venous circulation. Biocompatibility and thrombogenicity of our prosthesis have been examined in prior animal experiments, and 91% of valve conduits including early prototypes are patent at 3 weeks. However, evaluation of valve function is much more difficult in animals; therefore in this study the function of excised valves was evaluated ex vivo. METHODS: Nine bovine jugular vein conduits, each with one bileaflet venous valve, were harvested and placed in a venous flow simulator. Flows and pressures were adjusted to mimic human respiratory and hydrostatic variations. Each valve and conduit was tested for variations in valve diameter and sinus expansion in response to flow. Valve opening and closing times and valve competence were measured in response to pressure changes. After testing, each specimen was glutaraldehyde fixed and assessed a second time. RESULTS: Valve orifice area increased in response to flow in both fresh and fixed tissues. Maximum valve orifice area was reduced by fixation (27.7%) at full flows (p < 0.05). Valve sinus dimensions increased in response to increased pressure until maximum expansion was achieved (33 mm Hg). This was reduced 15.3% in fixed tissue (p < 0.05). Valve opening times (at < 1 mm Hg gradient) were slightly longer in fixed compared with fresh tissue (0.43 +/- 0.09 vs 0.41 +/- 0.13 second; p < 0.05). Valve closing times were comparable in both states (0.43 +/- 0.08 vs 0.49 +/- 0.07 second). Three fresh and seven fixed specimens that were subjected to 287 mm Hg back pressure exhibited minimal reflux. CONCLUSIONS: Size and availability make the bovine jugular vein valve an ideal venous valve substitute. Glutaraldehyde fixation renders the tissue biocompatible and nonthrombogenic while preserving anatomic integrity and leaflet strength and flexibility. Mounted and stented in a sewing sleeve, this prosthesis could represent the first generally applicable clinical solution to chronic venous insufficiency and venous hypertension.


Assuntos
Bioprótese , Prótese Vascular , Veias , Adulto , Animais , Pressão Sanguínea/fisiologia , Bovinos , Estudos de Avaliação como Assunto , Feminino , Hemodinâmica/fisiologia , Cavalos , Humanos , Técnicas In Vitro , Veias Jugulares/anatomia & histologia , Veias Jugulares/fisiologia , Macropodidae , Masculino , Modelos Cardiovasculares , Desenho de Prótese , Fluxo Sanguíneo Regional/fisiologia , Ovinos , Propriedades de Superfície , Tromboflebite/patologia , Tromboflebite/fisiopatologia , Tromboflebite/cirurgia , Veias/patologia , Veias/fisiopatologia
17.
J Heart Valve Dis ; 2(5): 504-8, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8269158

RESUMO

A novel approach to the prediction of valve-related complications in patients with implanted artificial heart valves is discussed. Adaptive artificial neural networks were used to identify patients at high risk of valve-related events based on preoperative data. Data from a clinical trial on 789 subjects with Carpentier-Edwards pericardial bioprostheses were used. Patients' records were divided into two groups, one of which was used for training the neural network and the other for testing the trained network and determining error rates. Patient information such as age, sex, NYHA class and anticoagulation therapy, as well as valve information such as size and the date of implant, were used as the network inputs. The neural net had a single output variable indicating the risk that an individual patient would develop a valve-related complication resulting in death. The results show that a trained neural network was able to predict valve-related deaths in the specified time interval of 1981-1991 with a high degree of accuracy. The neural network was also successful in classifying patients into high and low risk categories.


Assuntos
Próteses Valvulares Cardíacas , Redes Neurais de Computação , Complicações Pós-Operatórias/etiologia , Animais , Bioprótese , Causas de Morte , Seguimentos , Próteses Valvulares Cardíacas/mortalidade , Humanos , Complicações Pós-Operatórias/mortalidade , Vigilância de Produtos Comercializados , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Suínos
18.
19.
ASAIO J ; 39(3): M532-6, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8268592

RESUMO

The concerns about currently available bioprosthetic heart valves are calcification, long-term durability, and functional and hemodynamic performance. These concerns are all more or less related to the cross-linking reagents, glutaraldehyde or formaldehyde, used in fixing bioprostheses. To address these concerns, the authors undertook the development of a porcine heart valve cross-linked with an epoxy compound. This study compared the cross-linking characteristics, shrink temperature, and moisture content of porcine heart valves fixed with epoxy compounds or glutaraldehyde. Two types of epoxy compounds, Denacol EX-313 and EX-810, or a 0.625% glutaraldehyde were used to fix the porcine aortic valves procured from a slaughter house. Samples of each group were removed at various elapsed fixation times. The shrink temperature and moisture content of the valvular leaflet and distinct layers of aortic wall of each sample were measured. Fresh porcine aortic valve was used as a control. It was found that the shrink temperature of the glutaraldehyde leaflet was the highest, whereas the moisture content of the EX-313 leaflet was the greatest among the three test groups. No significant difference in shrink temperature was observed among the epoxy compound fixed inner, middle, outer, and entire aortic walls. This implied that the cross-linking density of the epoxy compound valve was uniform throughout the entire aortic wall. The same also was observed for the glutaraldehyde fixed aortic wall.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Bioprótese , Reagentes de Ligações Cruzadas , Compostos de Epóxi , Glutaral , Próteses Valvulares Cardíacas , Fixação de Tecidos , Animais , Valva Aórtica , Desenho de Prótese , Suínos
20.
ASAIO J ; 39(3): M691-4, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8268626

RESUMO

This study was performed to evaluate the degree of complement activation by three bovine arterial graft materials: Bioflow (Bio-Vascular Inc., a bovine artery fixed with dialdehyde starch), BioPolyMeric (St. Jude Medical Inc., a collagen conduit of bovine arterial origin, tanned with glutaraldehyde and covered with a Dacron mesh), and Denaflex (Baxter Edwards CVS Division, a bovine artery fixed with polyepoxy compounds). The grafts were rinsed by following the manufacturer's recommended procedures and thereafter incubated with normal human serum. CH50 assays were performed on the serum after incubation, and the percentage of complement activation for each sample was calculated relative to its control serum. The results indicated that the BioPolyMeric grafts activated the most complement, with about a 48% decrease in the CH50. The BioPolyMeric graft is composed of an outer polyester mesh and an inner collagenous tubing, exhibiting a nonreversible negative surface charge. After the polyester mesh was removed, the BioPolyMeric graft showed the highest complement activation in this study, suggesting that the glutaraldehyde fixed graft is more prone to complement activation than either the polyepoxy compound or dialdehyde starch fixed grafts. The complement fragment, C5a, generated during complement activation is strongly chemotactic for polymorphonuclear leukocytes and monocytes, which likely play early and long-lasting roles in regulating tissue reaction to the implanted graft.


Assuntos
Bioprótese , Prótese Vascular , Ativação do Complemento/imunologia , Teste de Materiais , Resinas Epóxi , Glutaral , Humanos , Desenho de Prótese , Amido/análogos & derivados , Curtume , Fixação de Tecidos
SELEÇÃO DE REFERÊNCIAS