Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38649588

RESUMO

BACKGROUND: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. METHODS: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. RESULTS: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. CONCLUSIONS: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment.

2.
J Am Heart Assoc ; 12(8): e028661, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-37042261

RESUMO

Background Idiopathic ventricular fibrillation (VF) is a diagnosis of exclusion following normal cardiac investigations. We sought to determine if exercise-induced changes in electrical substrate could distinguish patient groups with various ventricular arrhythmic pathophysiological conditions and identify patients susceptible to VF. Methods and Results Computed tomography and exercise testing in patients wearing a 252-electrode vest were combined to determine ventricular conduction stability between rest and peak exercise, as previously described. Using ventricular conduction stability, conduction heterogeneity in idiopathic VF survivors (n=14) was compared with those surviving VF during acute ischemia with preserved ventricular function following full revascularization (n=10), patients with benign ventricular ectopy (n=11), and patients with normal hearts, no arrhythmic history, and negative Ajmaline challenge during Brugada family screening (Brugada syndrome relatives; n=11). Activation patterns in normal subjects (Brugada syndrome relatives) are preserved following exercise, with mean ventricular conduction stability of 99.2±0.9%. Increased heterogeneity of activation occurred in the idiopathic VF survivors (ventricular conduction stability: 96.9±2.3%) compared with the other groups combined (versus 98.8±1.6%; P=0.001). All groups demonstrated periodic variation in activation heterogeneity (frequency, 0.3-1 Hz), but magnitude was greater in idiopathic VF survivors than Brugada syndrome relatives or patients with ventricular ectopy (7.6±4.1%, 2.9±2.9%, and 2.8±1.2%, respectively). The cause of this periodicity is unknown and was not replicable by introducing exercise-induced noise at comparable frequencies. Conclusions In normal subjects, ventricular activation patterns change little with exercise. In contrast, patients with susceptibility to VF experience activation heterogeneity following exercise that requires further investigation as a testable manifestation of underlying myocardial abnormalities otherwise silent during routine testing.


Assuntos
Síndrome de Brugada , Complexos Ventriculares Prematuros , Humanos , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Sistema de Condução Cardíaco , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/complicações , Eletrocardiografia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Sobreviventes
3.
Cardiovasc Eng Technol ; 13(2): 219-233, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34453278

RESUMO

PURPOSE: Left atrial (LA) rapid AF activity has been shown to co-localise with areas of successful atrial fibrillation termination by catheter ablation. We describe a technique that identifies rapid and regular activity. METHODS: Eight-second AF electrograms were recorded from LA regions during ablation for psAF. Local activation was annotated manually on bipolar signals and where these were of poor quality, we inspected unipolar signals. Dominant cycle length (DCL) was calculated from annotation pairs representing a single activation interval, using a probability density function (PDF) with kernel density estimation. Cumulative annotation duration compared to total segment length defined electrogram quality. DCL results were compared to dominant frequency (DF) and averaging. RESULTS: In total 507 8 s AF segments were analysed from 7 patients. Spearman's correlation coefficient was 0.758 between independent annotators (P < 0.001), 0.837-0.94 between 8 s and ≥ 4 s segments (P < 0.001), 0.541 between DCL and DF (P < 0.001), and 0.79 between DCL and averaging (P < 0.001). Poorer segment organization gave greater errors between DCL and DF. CONCLUSION: DCL identifies rapid atrial activity that may represent psAF drivers. This study uses DCL as a tool to evaluate the dynamic, patient specific properties of psAF by identifying rapid and regular activity. If automated, this technique could rapidly identify areas for ablation in psAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia , Análise Espacial
4.
Heart Rhythm ; 19(4): 516-524, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34915187

RESUMO

BACKGROUND: The ganglionated plexuses (GPs) of the intrinsic cardiac autonomic system may play a role in atrial fibrillation (AF). OBJECTIVE: We hypothesized that ablating the ectopy-triggering GPs (ET-GPs) prevents AF. METHODS: GANGLIA-AF (ClinicalTrials.gov identifier NCT02487654) was a prospective, randomized, controlled, 3-center trial. ET-GPs were mapped using high frequency stimulation, delivered within the atrial refractory period and ablated until nonfunctional. If triggered AF became incessant, atrioventricular dissociating GPs were ablated. We compared GP ablation (GPA) without pulmonary vein isolation (PVI) against PVI in patients with paroxysmal AF. Follow-up was for 12 months including 3-monthly 48-hour Holter monitors. The primary end point was documented ≥30 seconds of atrial arrhythmia after a 3-month blanking period. RESULTS: A total of 102 randomized patients were analyzed on a per-protocol basis after GPA (n = 52; 51%) or PVI (n = 50; 49%). Patients who underwent GPA had 89 ± 26 high frequency stimulation sites tested, identifying a median of 18.5% (interquartile range 16%-21%) of GPs. The radiofrequency ablation time was 22.9 ± 9.8 minutes in GPA and 38 ± 14.4 minutes in PVI (P < .0001). The freedom from ≥30 seconds of atrial arrhythmia at 12-month follow-up was 50% (26 of 52) with GPA vs 64% (32 of 50) with PVI (log-rank, P = .09). ET-GPA without atrioventricular dissociating GPA achieved 58% (22 of 38) freedom from the primary end point. There was a significantly higher reduction in antiarrhythmic drug usage postablation after GPA than after PVI (55.5% vs 36%; P = .05). Patients were referred for redo ablation procedures in 31% (16 of 52) after GPA and 24% (12 of 50) after PVI (P = .53). CONCLUSION: GPA did not prevent atrial arrhythmias more than PVI. However, less radiofrequency ablation was delivered to achieve a higher reduction in antiarrhythmic drug usage with GPA than with PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Gânglios/cirurgia , Átrios do Coração , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
5.
Front Physiol ; 12: 712454, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34858198

RESUMO

Background: Atrial fibrillation (AF) and ventricular fibrillation (VF) are complex heart rhythm disorders and may be sustained by distinct electrophysiological mechanisms. Disorganised self-perpetuating multiple-wavelets and organised rotational drivers (RDs) localising to specific areas are both possible mechanisms by which fibrillation is sustained. Determining the underlying mechanisms of fibrillation may be helpful in tailoring treatment strategies. We investigated whether global fibrillation organisation, a surrogate for fibrillation mechanism, can be determined from electrocardiograms (ECGs) using band-power (BP) feature analysis and machine learning. Methods: In this study, we proposed a novel ECG classification framework to differentiate fibrillation organisation levels. BP features were derived from surface ECGs and fed to a linear discriminant analysis classifier to predict fibrillation organisation level. Two datasets, single-channel ECGs of rat VF (n = 9) and 12-lead ECGs of human AF (n = 17), were used for model evaluation in a leave-one-out (LOO) manner. Results: The proposed method correctly predicted the organisation level from rat VF ECG with the sensitivity of 75%, specificity of 80%, and accuracy of 78%, and from clinical AF ECG with the sensitivity of 80%, specificity of 92%, and accuracy of 88%. Conclusion: Our proposed method can distinguish between AF/VF of different global organisation levels non-invasively from the ECG alone. This may aid in patient selection and guiding mechanism-directed tailored treatment strategies.

6.
Am J Cardiol ; 160: 53-59, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34610873

RESUMO

A multivariate risk score model was proposed by Sieira et al in 2017 for sudden death in Brugada syndrome; their validation in 150 patients was highly encouraging, with a C-index of 0.81; however, this score is yet to be validated by an independent group. A total of 192 records of patients with Brugada syndrome were collected from 2 centers in the United Kingdom and retrospectively scored according to a score model by Sieira et al. Data were compiled summatively over follow-up to mimic regular risk re-evaluation as per current guidelines. Sudden cardiac death survivor data were considered perievent to ascertain the utility of the score before cardiac arrest. Scores were compared with actual outcomes. Sensitivity in our cohort was 22.7%, specificity was 57.6%, and C-index was 0.58. In conclusion, up to 75% of cardiac arrest survivors in this cohort would not have been offered a defibrillator if evaluated before their event. This casts doubt on the utility of the score model for primary prevention of sudden death. Inherent issues with modern risk scoring strategies decrease the likelihood of success even in robustly designed tools such as the Sieira score model.


Assuntos
Síndrome de Brugada/terapia , Morte Súbita Cardíaca/epidemiologia , Síndrome de Brugada/complicações , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Medição de Risco , Síndrome do Nó Sinusal/fisiopatologia , Síncope/fisiopatologia , Reino Unido/epidemiologia
7.
Heart Rhythm O2 ; 2(5): 439-445, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34667958

RESUMO

BACKGROUND: His bundle pacing (HBP) can be achieved in 2 ways: selective HBP (S-HBP), where the His bundle is captured alone, and nonselective HBP (NS-HBP), where local myocardium is also captured, resulting a pre-excited electrocardiogram appearance. OBJECTIVE: We assessed the impact of this ventricular pre-excitation on left and right ventricular dyssynchrony. METHODS: We recruited patients who displayed both S-HBP and NS-HBP. We performed noninvasive epicardial electrical mapping for left and right ventricular activation time (LVAT and RVAT) and pattern. RESULTS: Twenty patients were recruited. In the primary analysis, the mean within-patient change in LVAT from S-HBP to NS-HBP was -5.5 ms (95% confidence interval: -0.6 to -10.4, noninferiority P < .0001). NS-HBP did not prolong RVAT (4.3 ms, -4.0 to 12.8, P = .296) but did prolong QRS duration (QRSd, 22.1 ms, 11.8 to 32.4, P = .0003). In patients with narrow intrinsic QRS (n = 6), NS-HBP preserved LVAT (-2.9 ms, -9.7 to 4.0, P = .331) but prolonged QRS duration (31.4 ms, 22.0 to 40.7, P = .0003) and mean RVAT (16.8 ms, -5.3 to 38.9, P = .108) compared to S-HBP. Activation pattern of the left ventricular surface was unchanged between S-HBP and NS-HBP, but NS-HBP produced early basal right ventricular activation that was not seen in S-HBP. CONCLUSION: Compared to S-HBP, local myocardial capture during NS-HBP produces pre-excitation of the basal right ventricle resulting in QRS duration prolongation. However, NS-HBP preserves the left ventricular activation time and pattern of S-HBP. Left ventricular dyssynchrony is not an important factor when choosing between S-HBP and NS-HBP in most patients.

8.
JACC Clin Electrophysiol ; 7(8): 988-999, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33812836

RESUMO

OBJECTIVES: This first-in-human feasibility study was undertaken to translate the novel low-voltage MultiPulse Therapy (MPT) (Cardialen, Inc., Minneapolis, Minnesota), which was previously been shown to be effective in preclinical studies in terminating atrial fibrillation (AF), into clinical use. BACKGROUND: Current treatment options for AF, the most common arrhythmia in clinical practice, have limited success. Previous attempts at treating AF by using implantable devices have been limited by the painful nature of high-voltage shocks. METHODS: Forty-two patients undergoing AF ablation were recruited at 6 investigational centers worldwide. Before ablation, electrode catheters were placed in the coronary sinus, right and/or left atrium, for recording and stimulation. After the induction of AF, MPT, which consists of up to a 3-stage sequence of far- and near-field stimulation pulses of varied amplitude, duration, and interpulse timing, was delivered via temporary intracardiac leads. MPT parameters and delivery methods were iteratively optimized. RESULTS: In the 14 patients from the efficacy phase, MPT terminated 37 of 52 (71%) of AF episodes, with the lowest median energy of 0.36 J (interquartile range [IQR]: 0.14 to 1.21 J) and voltage of 42.5 V (IQR: 25 to 75 V). Overall, 38% of AF terminations occurred within 2 seconds of MPT delivery (p < 0.0001). Shorter time between AF induction and MPT predicted success of MPT in terminating AF (p < 0.001). CONCLUSIONS: MPT effectively terminated AF at voltages and energies known to be well tolerated or painless in some patients. Our results support further studies of the concept of implanted devices for early AF conversion to reduce AF burden, symptoms, and progression.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/cirurgia , Cardioversão Elétrica , Eletrodos , Átrios do Coração , Humanos , Minnesota
9.
J Cardiovasc Electrophysiol ; 32(2): 428-438, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33345379

RESUMO

BACKGROUND: His bundle pacing (HBP) is an alternative to biventricular pacing (BVP) for delivering cardiac resynchronization therapy (CRT) in patients with heart failure and left bundle branch block (LBBB). It is not known whether ventricular activation times and patterns achieved by HBP are equivalent to intact conduction systems and not all patients with LBBB are resynchronized by HBP. OBJECTIVE: To compare activation times and patterns of His-CRT with BVP-CRT, LBBB and intact conduction systems. METHODS: In patients with LBBB, noninvasive epicardial mapping (ECG imaging) was performed during BVP and temporary HBP. Intrinsic activation was mapped in all subjects. Left ventricular activation times (LVAT) were measured and epicardial propagation mapping (EPM) was performed, to visualize epicardial wavefronts. Normal activation pattern and a normal LVAT range were determined from normal subjects. RESULTS: Forty-five patients were included, 24 with LBBB and LV impairment, and 21 with normal 12-lead ECG and LV function. In 87.5% of patients with LBBB, His-CRT successfully shortened LVAT by ≥10 ms. In 33.3%, His-CRT resulted in complete ventricular resynchronization, with activation times and patterns indistinguishable from normal subjects. EPM identified propagation discontinuity artifacts in 83% of patients with LBBB. This was the best predictor of whether successful resynchronization was achieved by HBP (logarithmic odds ratio, 2.19; 95% confidence interval, 0.07-4.31; p = .04). CONCLUSION: Noninvasive electrocardiographic mapping appears to identify patients whose LBBB can be resynchronized by HBP. In contrast to BVP, His-CRT may deliver the maximum potential ventricular resynchronization, returning activation times, and patterns to those seen in normal hearts.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Fascículo Atrioventricular , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento , Função Ventricular Esquerda
10.
Front Physiol ; 11: 570203, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33304272

RESUMO

BACKGROUND: Conduction velocity (CV) heterogeneity and myocardial fibrosis both promote re-entry, but the relationship between fibrosis as determined by left atrial (LA) late-gadolinium enhanced cardiac magnetic resonance imaging (LGE-CMRI) and CV remains uncertain. OBJECTIVE: Although average CV has been shown to correlate with regional LGE-CMRI in patients with persistent AF, we test the hypothesis that a localized relationship exists to underpin LGE-CMRI as a minimally invasive tool to map myocardial conduction properties for risk stratification and treatment guidance. METHOD: 3D LA electroanatomic maps during LA pacing were acquired from eight patients with persistent AF following electrical cardioversion. Local CVs were computed using triads of concurrently acquired electrograms and were co-registered to allow correlation with LA wall intensities obtained from LGE-CMRI, quantified using normalized intensity (NI) and image intensity ratio (IIR). Association was evaluated using multilevel linear regression. RESULTS: An association between CV and LGE-CMRI intensity was observed at scales comparable to the size of a mapping electrode: -0.11 m/s per unit increase in NI (P < 0.001) and -0.96 m/s per unit increase in IIR (P < 0.001). The magnitude of this change decreased with larger measurement area. Reproducibility of the association was observed with NI, but not with IIR. CONCLUSION: At clinically relevant spatial scales, comparable to area of a mapping catheter electrode, LGE-CMRI correlates with CV. Measurement scale is important in accurately quantifying the association of CV and LGE-CMRI intensity. Importantly, NI, but not IIR, accounts for changes in the dynamic range of CMRI and enables quantitative reproducibility of the association.

12.
Circ Arrhythm Electrophysiol ; 13(3): e008237, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32064900

RESUMO

BACKGROUND: The mechanisms sustaining myocardial fibrillation remain disputed, partly due to a lack of mapping tools that can accurately identify the mechanism with low spatial resolution clinical recordings. Granger causality (GC) analysis, an econometric tool for quantifying causal relationships between complex time-series, was developed as a novel fibrillation mapping tool and adapted to low spatial resolution sequentially acquired data. METHODS: Ventricular fibrillation (VF) optical mapping was performed in Langendorff-perfused Sprague-Dawley rat hearts (n=18), where novel algorithms were developed using GC-based analysis to (1) quantify causal dependence of neighboring signals and plot GC vectors, (2) quantify global organization with the causality pairing index, a measure of neighboring causal signal pairs, and (3) localize rotational drivers (RDs) by quantifying the circular interdependence of neighboring signals with the circular interdependence value. GC-based mapping tools were optimized for low spatial resolution from downsampled optical mapping data, validated against high-resolution phase analysis and further tested in previous VF optical mapping recordings of coronary perfused donor heart left ventricular wedge preparations (n=12), and adapted for sequentially acquired intracardiac electrograms during human persistent atrial fibrillation mapping (n=16). RESULTS: Global VF organization quantified by causality pairing index showed a negative correlation at progressively lower resolutions (50% resolution: P=0.006, R2=0.38, 12.5% resolution, P=0.004, R2=0.41) with a phase analysis derived measure of disorganization, locations occupied by phase singularities. In organized VF with high causality pairing index values, GC vector mapping characterized dominant propagating patterns and localized stable RDs, with the circular interdependence value showing a significant difference in driver versus nondriver regions (0.91±0.05 versus 0.35±0.06, P=0.0002). These findings were further confirmed in human VF. In persistent atrial fibrillation, a positive correlation was found between the causality pairing index and presence of stable RDs (P=0.0005,R2=0.56). Fifty percent of patients had RDs, with a low incidence of 0.9±0.3 RDs per patient. CONCLUSIONS: GC-based fibrillation analysis can measure global fibrillation organization, characterize dominant propagating patterns, and map RDs using low spatial resolution sequentially acquired data.


Assuntos
Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Animais , Fibrilação Atrial/cirurgia , Modelos Animais de Doenças , Ratos , Ratos Sprague-Dawley
13.
JACC Clin Electrophysiol ; 5(6): 705-715, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31221358

RESUMO

OBJECTIVES: This study sought to test specialized processing of laser Doppler signals for discriminating ventricular fibrillation (VF) from common causes of inappropriate therapies. BACKGROUND: Inappropriate implantable cardioverter-defibrillator (ICD) therapies remain a clinically important problem associated with morbidity and mortality. Tissue perfusion biomarkers, implemented to assist automated diagnosis of VF, sometimes mistake artifacts and random noise for perfusion, which could lead to shocks being inappropriately withheld. METHODS: The study tested a novel processing algorithm that combines electrogram data and laser Doppler perfusion monitoring as a method for assessing circulatory status. Fifty patients undergoing VF induction during ICD implantation were recruited. Noninvasive laser Doppler and continuous electrograms were recorded during both sinus rhythm and VF. Two additional scenarios that might have led to inappropriate shocks were simulated for each patient: ventricular lead fracture and T-wave oversensing. The laser Doppler was analyzed using 3 methods for reducing noise: 1) running mean; 2) oscillatory height; and 3) a novel quantification of electromechanical coupling which gates laser Doppler relative to electrograms. In addition, the algorithm was tested during exercise-induced sinus tachycardia. RESULTS: Only the electromechanical coupling algorithm found a clear perfusion cut off between sinus rhythm and VF (sensitivity and specificity of 100%). Sensitivity and specificity remained at 100% during simulated lead fracture and electrogram oversensing. (Area under the curve running mean: 0.91; oscillatory height: 0.86; electromechanical coupling: 1.00). Sinus tachycardia did not cause false positive results. CONCLUSIONS: Quantifying the coupling between electrical and perfusion signals increases reliability of discrimination between VF and artifacts that ICDs may interpret as VF. Incorporating such methods into future ICDs may safely permit reductions of inappropriate shocks.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Eletrocardiografia , Falha de Equipamento , Fluxometria por Laser-Doppler , Processamento de Sinais Assistido por Computador , Fibrilação Ventricular/diagnóstico , Idoso , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Taquicardia Sinusal
14.
Heart Rhythm ; 16(9): 1357-1367, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31170484

RESUMO

BACKGROUND: Bipolar electrogram voltage during sinus rhythm (VSR) has been used as a surrogate for atrial fibrosis in guiding catheter ablation of persistent atrial fibrillation (AF), but the fixed rate and wavefront characteristics present during sinus rhythm may not accurately reflect underlying functional vulnerabilities responsible for AF maintenance. OBJECTIVE: The purpose of this study was determine whether, given adequate temporal sampling, the spatial distribution of mean AF voltage (VmAF) better correlates with delayed-enhancement magnetic resonance imaging (MRI-DE)-detected atrial fibrosis than VSR. METHODS: AF was mapped (8 seconds) during index ablation for persistent AF (20 patients) using a 20-pole catheter (660 ± 28 points/map). After cardioversion, VSR was mapped (557 ± 326 points/map). Electroanatomic and MRI-DE maps were co-registered in 14 patients. RESULTS: The time course of VmAF was assessed from 1-40 AF cycles (∼8 seconds) at 1113 locations. VmAF stabilized with sampling >4 seconds (mean voltage error 0.05 mV). Paired point analysis of VmAF from segments acquired 30 seconds apart (3667 sites; 15 patients) showed strong correlation (r = 0.95; P <.001). Delayed enhancement (DE) was assessed across the posterior left atrial (LA) wall, occupying 33% ± 13%. VmAF distributions were (median [IQR]) 0.21 [0.14-0.35] mV in DE vs 0.52 [0.34-0.77] mV in non-DE regions. VSR distributions were 1.34 [0.65-2.48] mV in DE vs 2.37 [1.27-3.97] mV in non-DE. VmAF threshold of 0.35 mV yielded sensitivity of 75% and specificity of 79% in detecting MRI-DE compared with 63% and 67%, respectively, for VSR (1.8-mV threshold). CONCLUSION: The correlation between low-voltage and posterior LA MRI-DE is significantly improved when acquired during AF vs sinus rhythm. With adequate sampling, mean AF voltage is a reproducible marker reflecting the functional response to the underlying persistent AF substrate.


Assuntos
Fibrilação Atrial , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração , Imagem Cinética por Ressonância Magnética/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Correlação de Dados , Feminino , Fibrose/complicações , Fibrose/diagnóstico , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
15.
J Am Coll Cardiol ; 72(24): 3112-3122, 2018 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-30545450

RESUMO

BACKGROUND: His bundle pacing is a new method for delivering cardiac resynchronization therapy (CRT). OBJECTIVES: The authors performed a head-to-head, high-precision, acute crossover comparison between His bundle pacing and conventional biventricular CRT, measuring effects on ventricular activation and acute hemodynamic function. METHODS: Patients with heart failure and left bundle branch block referred for conventional biventricular CRT were recruited. Using noninvasive epicardial electrocardiographic imaging, the authors identified patients in whom His bundle pacing shortened left ventricular activation time. In these patients, the authors compared the hemodynamic effects of His bundle pacing against biventricular pacing using a high-multiple repeated alternation protocol to minimize the effect of noise, as well as comparing effects on ventricular activation. RESULTS: In 18 of 23 patients, left ventricular activation time was significantly shortened by His bundle pacing. Seventeen patients had a complete electromechanical dataset. In them, His bundle pacing was more effective at delivering ventricular resynchronization than biventricular pacing: greater reduction in QRS duration (-18.6 ms; 95% confidence interval [CI]: -31.6 to -5.7 ms; p = 0.007), left ventricular activation time (-26 ms; 95% CI: -41 to -21 ms; p = 0.002), and left ventricular dyssynchrony index (-11.2 ms; 95% CI: -16.8 to -5.6 ms; p < 0.001). His bundle pacing also produced a greater acute hemodynamic response (4.6 mm Hg; 95% CI: 0.2 to 9.1 mm Hg; p = 0.04). The incremental activation time reduction with His bundle pacing over biventricular pacing correlated with the incremental hemodynamic improvement with His bundle pacing over biventricular pacing (R = 0.70; p = 0.04). CONCLUSIONS: His resynchronization delivers better ventricular resynchronization, and greater improvement in hemodynamic parameters, than biventricular pacing.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo/complicações , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/complicações , Idoso , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
16.
Europace ; 20(suppl_3): iii3-iii15, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30476057

RESUMO

AIMS: Atrial fibrillation (AF) wavefront dynamics are complex and difficult to interpret, contributing to uncertainty about the mechanisms that maintain AF. We aimed to investigate the interplay between rotors, wavelets, and focal sources during fibrillation. METHODS AND RESULTS: Arrhythmia wavefront dynamics were analysed for four optically mapped canine cholinergic AF preparations. A bilayer computer model was tuned to experimental preparations, and varied to have (i) fibrosis in both layers or the epicardium only, (ii) different spatial acetylcholine distributions, (iii) different intrinsic action potential duration between layers, and (iv) varied interlayer connectivity. Phase singularities (PSs) were identified and tracked over time to identify rotational drivers. New focal wavefronts were identified using phase contours. Phase singularity density and new wavefront locations were calculated during AF. There was a single dominant mechanism for sustaining AF in each of the preparations, either a rotational driver or repetitive new focal wavefronts. High-density PS sites existed preferentially around the pulmonary vein junctions. Three of the four preparations exhibited stable preferential sites of new wavefronts. Computational simulations predict that only a small number of connections are functionally important in sustaining AF, with new wavefront locations determined by the interplay between fibrosis distribution, acetylcholine concentration, and heterogeneity in repolarization within layers. CONCLUSION: We were able to identify preferential sites of new wavefront initiation and rotational activity, in order to determine the mechanisms sustaining AF. Electrical measurements should be interpreted differently according to whether they are endocardial or epicardial recordings.


Assuntos
Potenciais de Ação , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Fibras Colinérgicas , Átrios do Coração/inervação , Frequência Cardíaca , Animais , Fibrilação Atrial/diagnóstico , Remodelamento Atrial , Simulação por Computador , Modelos Animais de Doenças , Cães , Fibrose , Átrios do Coração/patologia , Modelos Cardiovasculares , Fatores de Tempo , Imagens com Corantes Sensíveis à Voltagem
17.
Comput Biol Med ; 102: 315-326, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30025847

RESUMO

Atrial and ventricular fibrillation are complex arrhythmias, and their underlying mechanisms remain widely debated and incompletely understood. This is partly because the electrical signals recorded during myocardial fibrillation are themselves complex and difficult to interpret with simple analytical tools. There are currently a number of analytical approaches to handle fibrillation data. Some of these techniques focus on mapping putative drivers of myocardial fibrillation, such as dominant frequency, organizational index, Shannon entropy and phase mapping. Other techniques focus on mapping the underlying myocardial substrate sustaining fibrillation, such as voltage mapping and complex fractionated electrogram mapping. In this review, we discuss these techniques, their application and their limitations, with reference to our experimental and clinical data. We also describe novel tools including a new algorithm to map microreentrant circuits sustaining fibrillation.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Eletrocardiografia , Coração/diagnóstico por imagem , Miocárdio/patologia , Fibrilação Ventricular/diagnóstico por imagem , Algoritmos , Animais , Linhagem Celular , Técnicas Eletrofisiológicas Cardíacas/métodos , Entropia , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Processamento de Sinais Assistido por Computador
18.
Circ Arrhythm Electrophysiol ; 10(5): e004899, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28500175

RESUMO

BACKGROUND: Recent studies have demonstrated conflicting mechanisms underlying atrial fibrillation (AF), with the spatial resolution of data often cited as a potential reason for the disagreement. The purpose of this study was to investigate whether the variation in spatial resolution of mapping may lead to misinterpretation of the underlying mechanism in persistent AF. METHODS AND RESULTS: Simulations of rotors and focal sources were performed to estimate the minimum number of recording points required to correctly identify the underlying AF mechanism. The effects of different data types (action potentials and unipolar or bipolar electrograms) and rotor stability on resolution requirements were investigated. We also determined the ability of clinically used endocardial catheters to identify AF mechanisms using clinically recorded and simulated data. The spatial resolution required for correct identification of rotors and focal sources is a linear function of spatial wavelength (the distance between wavefronts) of the arrhythmia. Rotor localization errors are larger for electrogram data than for action potential data. Stationary rotors are more reliably identified compared with meandering trajectories, for any given spatial resolution. All clinical high-resolution multipolar catheters are of sufficient resolution to accurately detect and track rotors when placed over the rotor core although the low-resolution basket catheter is prone to false detections and may incorrectly identify rotors that are not present. CONCLUSIONS: The spatial resolution of AF data can significantly affect the interpretation of the underlying AF mechanism. Therefore, the interpretation of human AF data must be taken in the context of the spatial resolution of the recordings.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Eletrocardiografia/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Desenho de Equipamento , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
19.
Ann Biomed Eng ; 45(4): 910-923, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27921187

RESUMO

Extracellular electrograms recorded during atrial fibrillation (AF) are challenging to interpret due to the inherent beat-to-beat variability in amplitude and duration. Phase mapping represents these voltage signals in terms of relative position within the cycle, and has been widely applied to action potential and unipolar electrogram data of myocardial fibrillation. To date, however, it has not been applied to bipolar recordings, which are commonly acquired clinically. The purpose of this study is to present a novel algorithm for calculating phase from both unipolar and bipolar electrograms recorded during AF. A sequence of signal filters and processing steps are used to calculate phase from simulated, experimental, and clinical, unipolar and bipolar electrograms. The algorithm is validated against action potential phase using simulated data (trajectory centre error <0.8 mm); between experimental multi-electrode array unipolar and bipolar phase; and for wavefront identification in clinical atrial tachycardia. For clinical AF, similar rotational content (R 2 = 0.79) and propagation maps (median correlation 0.73) were measured using either unipolar or bipolar recordings. The algorithm is robust, uses standard signal processing techniques, and accurately quantifies AF wavefronts and sources. Identifying critical sources, such as rotors, in AF, may allow for more accurate targeting of ablation therapy and improved patient outcomes.


Assuntos
Potenciais de Ação , Algoritmos , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Processamento de Sinais Assistido por Computador , Feminino , Humanos , Masculino
20.
Artigo em Inglês | MEDLINE | ID: mdl-26736675

RESUMO

Registration of electroanatomic surfaces and segmented images for the co-localisation of structural and functional data typically requires the manual selection of fiducial points, which are used to initialise automated surface registration. The identification of equivalent points on geometric features by the human eye is heavily subjective, and error in their selection may lead to distortion of the transformed surface and subsequently limit the accuracy of data co-localisation. We propose that the manual trimming of the pulmonary veins through the region of greatest geometrical curvature, coupled with an automated angle-based fiducial-point selection algorithm, significantly reduces target registration error compared with direct manual selection of fiducial points.


Assuntos
Átrios do Coração/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Veias Pulmonares/anatomia & histologia , Algoritmos , Diagnóstico por Imagem , Eletrocardiografia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...