Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
NMR Biomed ; : e5159, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634301

RESUMO

Over the last decade, it has become evident that cerebrospinal fluid (CSF) plays a pivotal role in brain solute clearance through perivascular pathways and interactions between the brain and meningeal lymphatic vessels. Whereas most of this fundamental knowledge was gained from rodent models, human brain clearance imaging has provided important insights into the human system and highlighted the existence of important interspecies differences. Current gold standard techniques for human brain clearance imaging involve the injection of gadolinium-based contrast agents and monitoring their distribution and clearance over a period from a few hours up to 2 days. With both intrathecal and intravenous injections being used, which each have their own specific routes of distribution and thus clearance of contrast agent, a clear understanding of the kinetics associated with both approaches, and especially the differences between them, is needed to properly interpret the results. Because it is known that intrathecally injected contrast agent reaches the blood, albeit in small concentrations, and that similarly some of the intravenously injected agent can be detected in CSF, both pathways are connected and will, in theory, reach the same compartments. However, because of clear differences in relative enhancement patterns, both injection approaches will result in varying sensitivities for assessment of different subparts of the brain clearance system. In this opinion review article, the "EU Joint Programme - Neurodegenerative Disease Research (JPND)" consortium on human brain clearance imaging provides an overview of contrast agent pharmacokinetics in vivo following intrathecal and intravenous injections and what typical concentrations and concentration-time curves should be expected. This can be the basis for optimizing and interpreting contrast-enhanced MRI for brain clearance imaging. Furthermore, this can shed light on how molecules may exchange between blood, brain, and CSF.

2.
J Cereb Blood Flow Metab ; : 271678X241230741, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315044

RESUMO

White matter hyperintensities (WMH), perivascular spaces (PVS) and lacunes are common MRI features of small vessel disease (SVD). However, no shared underlying pathological mechanism has been identified. We investigated whether SVD burden, in terms of WMH, PVS and lacune status, was related to changes in the cerebral arterial wall by applying global cerebral pulse wave velocity (gcPWV) measurements, a newly described marker of cerebral vascular stiffness. In a population-based cohort of 190 individuals, 66-85 years old, SVD features were estimated from T1-weighted and FLAIR images while gcPWV was estimated from 4D flow MRI data. Additionally, the gcPWV's stability to variations in field-of-view was analyzed. The gcPWV was 10.82 (3.94) m/s and displayed a significant correlation to WMH and white matter PVS volume (r = 0.29, p < 0.001; r = 0.21, p = 0.004 respectively from nonparametric tests) that persisted after adjusting for age, blood pressure variables, body mass index, ApoB/A1 ratio, smoking as well as cerebral pulsatility index, a previously suggested early marker of SVD. The gcPWV displayed satisfactory stability to field-of-view variations. Our results suggest that SVD is accompanied by changes in the cerebral arterial wall that can be captured by considering the velocity of the pulse wave transmission through the cerebral arterial network.

3.
Anesthesiology ; 140(4): 669-678, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37756527

RESUMO

BACKGROUND: Adequate cerebral perfusion is central during general anesthesia. However, perfusion is not readily measured bedside. Clinicians currently rely mainly on mean arterial pressure (MAP) as a surrogate, even though the relationship between blood pressure and cerebral blood flow is not well understood. The aim of this study was to apply phase-contrast magnetic resonance imaging to characterize blood flow responses in healthy volunteers to commonly used pharmacologic agents that increase or decrease arterial blood pressure. METHODS: Eighteen healthy volunteers aged 30 to 50 yr were investigated with phase-contrast magnetic resonance imaging. Intra-arterial blood pressure monitoring was used. First, intravenous noradrenaline was administered to a target MAP of 20% above baseline. After a wash-out period, intravenous labetalol was given to a target MAP of 15% below baseline. Cerebral blood flow was measured using phase-contrast magnetic resonance imaging and defined as the sum of flow in the internal carotid arteries and vertebral arteries. Cardiac output (CO) was defined as the flow in the ascending aorta. RESULTS: Baseline median cerebral blood flow was 772 ml/min (interquartile range, 674 to 871), and CO was 5,874 ml/min (5,199 to 6,355). The median dose of noradrenaline was 0.17 µg · kg-1 · h-1 (0.14 to 0.22). During noradrenaline infusion, cerebral blood flow decreased to 705 ml/min (606 to 748; P = 0.001), and CO decreased to 4,995 ml/min (4,705 to 5,635; P = 0.01). A median dose of labetalol was 120 mg (118 to 150). After labetalol boluses, cerebral blood flow was unchanged at 769 ml/min (734 to 900; P = 0.68). CO increased to 6,413 ml/min (6,056 to 7,464; P = 0.03). CONCLUSIONS: In healthy, awake subjects, increasing MAP using intravenous noradrenaline decreased cerebral blood flow and CO. These data do not support inducing hypertension with noradrenaline to increase cerebral blood flow. Cerebral blood flow was unchanged when decreasing MAP using labetalol.


Assuntos
Labetalol , Humanos , Labetalol/farmacologia , Labetalol/uso terapêutico , Pressão Sanguínea , Norepinefrina , Voluntários Saudáveis , Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética
4.
J Appl Physiol (1985) ; 134(2): 242-252, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36548513

RESUMO

Pulsation of the cerebral blood flow (CBF) produces intercranial pressure (ICP) waves. The aim of this study is to determine whether externally modifying ICP pulsatility alters parenchymal blood flow pulsatility. A cardiac-gated inflatable device was inserted in the lateral epidural space of 12 anesthetized canines (canis familiaris) and used to cause reduction, inversion, and augmentation of the ICP pulse. CBF in each hemisphere was measured using laser Doppler velocimetry. A significant increase in both mean CBF and its amplitude was observed for reduction as well as inversion of the ICP pulse, with larger changes observed for the inversion protocol. Significant increases in the mean CBF were also observed ipsilaterally for the augmentation protocol together with indications of reduced CBF amplitude contralaterally. External alteration of the ICP pulse thus caused significant changes in parenchymal blood flow pulsatility. The inverse relationship between the ICP and CBF amplitude suggests that the changes did not occur via modification of the intracranial Windkessel mechanism. Thus, the effects likely occurred in the low-pressure vessels, i.e., capillaries and/or venules, rather than the high-pressure arteries. Future MRI studies are however required to map and quantify the effects on global cerebral blood flow.NEW & NOTEWORTHY This study demonstrated that external modification of ICP pulsatility, using a cardiac-gated inflatable device implanted epidurally in canines, alters brain tissue blood flow pulsatility. Specifically, decreasing systolic ICP increased blood flow pulsatility in brain tissue. The results suggest that the altered CBF pulsatility is unlikely to depend on modification of the Windkessel effect on the feeding arterial system but was rather an effect directly on tissue and the lower pressure distal vessels.


Assuntos
Circulação Cerebrovascular , Hemodinâmica , Animais , Cães , Pressão Sanguínea/fisiologia , Circulação Cerebrovascular/fisiologia , Encéfalo , Imageamento por Ressonância Magnética , Pressão Intracraniana/fisiologia
5.
Fluids Barriers CNS ; 19(1): 2, 2022 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-34983575

RESUMO

INTRODUCTION: The treatment of hydrocephalus has been a topic of intense research ever since the first clinically successful use of a valved cerebrospinal fluid shunt 72 years ago. While ample studies elucidating different phenomena impacting this treatment exist, there are still gaps to be filled. Specifically, how intracranial, intrathecal, arterial, and venous pressures react and communicate with each other simultaneously. METHODS: An in-vivo sheep trial (n = 6) was conducted to evaluate and quantify the communication existing within the cranio-spinal, arterial, and venous systems (1 kHz sampling frequency). Standardized intrathecal infusion testing was performed using an automated infusion apparatus, including bolus and constant pressure infusions. Bolus infusions entailed six lumbar intrathecal infusions of 2 mL Ringer's solution. Constant pressure infusions were comprised of six regulated pressure steps of 3.75 mmHg for periods of 7 min each. Mean pressure reactions, pulse amplitude reactions, and outflow resistance were calculated. RESULTS: All sheep showed intracranial pressure reactions to acute increases of intrathecal pressure, with four of six sheep showing clear cranio-spinal communication. During bolus infusions, the increases of mean pressure for intrathecal, intracranial, arterial, and venous pressure were 16.6 ± 0.9, 15.4 ± 0.8, 3.9 ± 0.8, and 0.1 ± 0.2 mmHg with corresponding pulse amplitude increases of 2.4 ± 0.3, 1.3 ± 0.3, 1.3 ± 0.3, and 0.2 ± 0.1 mmHg, respectively. During constant pressure infusions, mean increases from baseline were 14.6 ± 3.8, 15.5 ± 4.2, 4.2 ± 8.2, and 3.2 ± 2.4 mmHg with the corresponding pulse amplitude increases of 2.5 ± 3.6, 2.5 ± 3.0, 7.7 ± 4.3, and 0.7 ± 2.0 mmHg for intrathecal, intracranial, arterial, and venous pulse amplitude, respectively. Outflow resistances were calculated as 51.6 ± 7.8 and 77.8 ± 14.5 mmHg/mL/min for the bolus and constant pressure infusion methods, respectively-showing deviations between the two estimation methods. CONCLUSIONS: Standardized infusion tests with multi-compartmental pressure recordings in sheep have helped capture distinct reactions between the intrathecal, intracranial, arterial, and venous systems. Volumetric pressure changes in the intrathecal space have been shown to propagate to the intraventricular and arterial systems in our sample, and to the venous side in individual cases. These results represent an important step into achieving a more complete quantitative understanding of how an acute rise in intrathecal pressure can propagate and influence other systems.


Assuntos
Pressão Arterial/fisiologia , Pressão do Líquido Cefalorraquidiano/fisiologia , Infusão Espinal , Espaço Subaracnóideo/fisiologia , Pressão Venosa/fisiologia , Animais , Pressão Intracraniana/fisiologia , Ovinos
6.
Acta Neurochir (Wien) ; 163(12): 3353-3368, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34453214

RESUMO

BACKGROUND: Idiopathic intracranial hypertension (IIH) is a rare disease of unknown aetiology related possibly to disturbed cerebrospinal fluid (CSF) dynamics and characterised by elevated intracranial pressure (ICP) causing optic nerve atrophy if not timely treated. We studied CSF dynamics of the IIH patients based on the available literature and our well-defined cohort. METHOD: A literature review was performed from PubMed between 1980 and 2020 in compliance with the PRISMA guideline. Our study includes 59 patients with clinical, demographical, neuro-ophthalmological, radiological, outcome data, and lumbar CSF pressure measurements for suspicion of IIH; 39 patients had verified IIH while 20 patients did not according to Friedman's criteria, hence referred to as symptomatic controls. RESULTS: The literature review yielded 19 suitable studies; 452 IIH patients and 264 controls had undergone intraventricular or lumbar CSF pressure measurements. In our study, the mean CSF pressure, pulse amplitudes, power of respiratory waves (RESP), and the pressure constant (P0) were higher in IIH than symptomatic controls (p < 0.01). The mean CSF pressure was higher in IIH patients with psychiatric comorbidity than without (p < 0.05). In IIH patients without acetazolamide treatment, the RAP index and power of slow waves were also higher (p < 0.05). IIH patients with excess CSF around the optic nerves had lower relative pulse pressure coefficient (RPPC) and RESP than those without (p < 0.05). CONCLUSIONS: Our literature review revealed increased CSF pressure, resistance to CSF outflow and sagittal sinus pressure (SSP) as key findings in IIH. Our study confirmed significantly higher lumbar CSF pressure and increased CSF pressure waves and RAP index in IIH when excluding patients with acetazolamide treatment. In overall, the findings reflect decreased craniospinal compliance and potentially depleted cerebral autoregulation resulting from the increased CSF pressure in IIH. The increased slow waves in patients without acetazolamide may indicate issues in autoregulation, while increased P0 could reflect the increased SSP.


Assuntos
Hipertensão Intracraniana , Pseudotumor Cerebral , Pressão do Líquido Cefalorraquidiano , Comorbidade , Cavidades Cranianas , Humanos , Hipertensão Intracraniana/epidemiologia
7.
J Cereb Blood Flow Metab ; 41(10): 2769-2777, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33853409

RESUMO

Intracranial arterial stiffening is a potential early marker of emerging cerebrovascular dysfunction and could be mechanistically involved in disease processes detrimental to brain function via several pathways. A prominent consequence of arterial wall stiffening is the increased velocity at which the systolic pressure pulse wave propagates through the vasculature. Previous non-invasive measurements of the pulse wave propagation have been performed on the aorta or extracranial arteries with results linking increased pulse wave velocity to brain pathology. However, there is a lack of intracranial "target-organ" measurements. Here we present a 4D flow MRI method to estimate pulse wave velocity in the intracranial vascular tree. The method utilizes the full detectable branching structure of the cerebral vascular tree in an optimization framework that exploits small temporal shifts that exists between waveforms sampled at varying depths in the vasculature. The method is shown to be stable in an internal consistency test, and of sufficient sensitivity to robustly detect age-related increases in intracranial pulse wave velocity.


Assuntos
Artérias/patologia , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Cerebrais/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Análise de Onda de Pulso/métodos , Rigidez Vascular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade
8.
Acta Ophthalmol ; 99(5): e679-e685, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33210819

RESUMO

PURPOSE: To examine feasibility of phase-contrast magnetic resonance imaging (PCMRI) and to assess blood flow rate in the ophthalmic artery (OA) in patients with normal tension glaucoma (NTG) compared with healthy controls. METHODS: Sixteen patients with treated NTG and 16 age- and sex-matched healthy controls underwent PCMRI using a 3-Tesla scanner and ophthalmological examinations. OA blood flow rate was measured using a 2D PCMRI sequence with a spatial resolution of 0.35 mm2 . RESULTS: The blood flow rate in the NTG group was 9.6 ± 3.9 ml/min [mean ± SD] compared with 11.9 ± 4.8 ml/min in the control group. Resistance Index (RI) and Pulsatility Index (PI) were 0.73 ± 0.08 and 1.36 ± 0.29, respectively, in the NTG group and 0.68 ± 0.13 and 1.22 ± 0.40, respectively, in the healthy group. The mean visual field index (VFI) was 46% ± 25 for the worse NTG eyes. The measured differences observed between the NTG group and the control group in blood flow rate (p = 0.12), RI (p = 0.18) and PI (p = 0.27) were non-significant. CONCLUSIONS: This case-control study, using PCMRI, showed a slight, but non-significant, reduction in OA blood flow rate in the NTG patients compared with the healthy controls. These results indicate that blood flow may be of importance in the pathogenesis of NTG. Considering that only a limited portion of the total OA blood flow supplies the ocular system and the large inter-individual differences, a larger study or more advanced PCMRI technique might give the answer.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Intraocular/fisiologia , Glaucoma de Baixa Tensão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Artéria Oftálmica/diagnóstico por imagem , Idoso , Estudos de Viabilidade , Feminino , Humanos , Glaucoma de Baixa Tensão/diagnóstico , Masculino , Artéria Oftálmica/fisiopatologia , Estudos Prospectivos , Curva ROC , Ultrassonografia Doppler em Cores
9.
Invest Ophthalmol Vis Sci ; 61(12): 17, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33074299

RESUMO

Purpose: To investigate if decrease of IOP affects the volumetric blood flow rate in the ophthalmic artery (OA) in patients with previously untreated ocular hypertension. Methods: Subjects with untreated ocular hypertension (n = 30; mean age 67 ± 8 years; 14 females) underwent ophthalmologic examination and a 3-Tesla magnetic resonance imaging investigation. The magnetic resonance imaging included three-dimensional high-resolution phase-contrast magnetic resonance imaging to measure the OA blood flow rate. The subjects received latanoprost once daily in the eye with higher pressure, the untreated eye served as control. The same measurements were repeated approximately 1 week later. Results: The mean OA blood flow rate before and after treatment was 12.4 ± 4.4 and 12.4 ± 4.6 mL/min in the treated eye (mean ± SD; P = 0.92) and 13.5 ± 5.2 and 13.4 ± 4.1 mL/min in the control eye (P = 0.92). There was no significant difference between the treated and control eye regarding blood flow rate before (P = 0.13) or after treatment (P = 0.18), or change in blood flow rate after treatment (0.1 ± 3.1 vs. -0.1 ± 4.0 mL/min, P = 0.84). Latanoprost decreased the IOP by 7.2 ± 3.1 mm Hg in the treated eye (P < 0.01). Conclusions: The results indicate that a significant lowering of IOP does not affect the blood flow rate of the OA in ocular hypertension subjects. The ability to maintain blood supply to the eye independent of the IOP could be a protective mechanism in preserving vision in subjects with ocular hypertension.


Assuntos
Pressão Intraocular/fisiologia , Hipertensão Ocular/fisiopatologia , Artéria Oftálmica/fisiopatologia , Idoso , Anti-Hipertensivos/uso terapêutico , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Feminino , Humanos , Latanoprosta/uso terapêutico , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/tratamento farmacológico , Estudos Prospectivos , Fluxo Sanguíneo Regional/fisiologia , Tonometria Ocular
10.
Neurosurgery ; 87(6): 1299-1310, 2020 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-32533835

RESUMO

BACKGROUND: We have previously reported a method and device capable of manipulating ICP pulsatility while minimally effecting mean ICP. OBJECTIVE: To test the hypothesis that different modulations of the intracranial pressure (ICP) pulse waveform will have a differential effect on cerebral blood flow (CBF). METHODS: Using an epidural balloon catheter attached to a cardiac-gated oscillating pump, 13 canine subjects underwent ICP waveform manipulation comparing different sequences of oscillation in successive animals. The epidural balloon was implanted unilaterally superior to the Sylvian sulcus. Subjects underwent ICP pulse augmentation, reduction and inversion protocols, directly comparing time segments of system activation and deactivation. ICP and CBF were measured bilaterally along with systemic pressure and heart rate. CBF was measured using both thermal diffusion, and laser doppler probes. RESULTS: The activation of the cardiac-gate balloon implant resulted in an ipsilateral/contralateral ICP pulse amplitude increase with augmentation (217%/202% respectively, P < .0005) and inversion (139%/120%, P < .0005). The observed changes associated with the ICP mean values were smaller, increasing with augmentation (23%/31%, P < .0001) while decreasing with inversion (7%/11%, P = .006/.0003) and reduction (4%/5%, P < .0005). CBF increase was observed for both inversion and reduction protocols (28%/7.4%, P < .0001/P = .006 and 2.4%/1.3%, P < .0001/P = .003), but not the augmentation protocol. The change in CBF was correlated with ICP pulse amplitude and systolic peak changes and not with change in mean ICP or systemic variables (heart rate, arterial blood pressure). CONCLUSION: Cardiac-gated manipulation of ICP pulsatility allows the study of intracranial pulsatile dynamics and provides a potential means of altering CBF.


Assuntos
Circulação Cerebrovascular , Hipertensão Intracraniana , Animais , Pressão Arterial , Pressão Sanguínea , Cães , Humanos , Pressão Intracraniana
11.
J Neurosurg ; : 1-6, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30497143

RESUMO

OBJECTIVEIntracranial pressure (ICP), outflow resistance (Rout), and amplitude of cardiac-related ICP pulsations (AMPs) are established parameters to describe the CSF hydrodynamic system and are assumed, but not confirmed, to be disturbed in idiopathic normal pressure hydrocephalus (INPH). The aim of this study was to compare the CSF hydrodynamic profile between patients with INPH and healthy volunteers.METHODSSixty-two consecutive INPH patients (mean age 74 years) and 40 healthy volunteers (mean age 70 years) were included. Diagnosis was made by two independent neurologists who assessed patients' history, neurological status, and MRI studies. A CSF dynamic investigation through the lumbar route was performed: ICP and other CSF dynamic variables were blinded to the neurologists during the diagnostic process and were not used for establishing the diagnosis of INPH.RESULTSRout was significantly higher in INPH (Rout 17.1 vs 11.1; p < 0.001), though a substantial number of INPH subjects had normal Rout. There were no differences between INPH patients and controls regarding ICP (mean 11.5 mm Hg). At resting pressure, there was a trend that AMP in INPH was increased (2.4 vs 2.0 mm Hg; p = 0.109). The relationship between AMP and ICP was that they shared the same slope, but the curve was significantly shifted to the left for INPH (reduced P0 [p < 0.05]; i.e., higher AMP for the same ICP).CONCLUSIONSThis study established that the CSF dynamic profile of INPH deviates from that of healthy volunteers and that INPH should thus be regarded as a disease in which intracranial hydrodynamics are part of the pathophysiology.Clinical trial registration no.: NCT01188382 (clinicaltrials.gov).

14.
Ophthalmology ; 125(3): 361-368, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29096996

RESUMO

PURPOSE: To test the hypothesis that normal-tension glaucoma (NTG) is caused by an increased pressure difference across the lamina cribrosa (LC) related to a low intracranial pressure (ICP). DESIGN: Prospective case-control study. PARTICIPANTS: Thirteen NTG patients (9 women; median 71 [range: 56-83] years) were recruited for investigation with the same protocol as 11 healthy volunteers (8 women; 47 [30-59] years). A larger control group (n = 51; 30 women; 68 [30-81] years) was used only for ICP comparison in supine position. METHODS: ICP and intraocular pressure (IOP) were simultaneously measured in supine, sitting, and 9° head-down tilt (HDT) positions. Trans-lamina cribrosa pressure difference (TLCPD) was calculated using ICP and IOP together with geometric distances estimated from magnetic resonance imaging to adjust for hydrostatic effects. MAIN OUTCOME MEASURES: ICP, IOP, and TLCPD in different body positions. RESULTS: Between NTG patients and healthy volunteers, there were no differences in ICP, IOP, or TLCPD in supine, sitting, or HDT (P ≥ 0.11), except for IOP in HDT (P = 0.04). There was no correlation between visual field defect and TLCPD, IOP, or ICP and in any body position (P ≥ 0.39). Mean ICP in supine was 10.3 mmHg (SD = 2.7) in the NTG group (n = 13) and 11.3 (2.2) mmHg in the larger control group (n = 51) (P = 0.24). CONCLUSIONS: There was no evidence of reduced ICP in NTG patients as compared with healthy controls, either in supine or in upright position. Consequently, the hypothesis that NTG is caused by an elevated TLCPD from low ICP was not supported.


Assuntos
Pressão Intracraniana/fisiologia , Pressão Intraocular/fisiologia , Glaucoma de Baixa Tensão/fisiopatologia , Postura/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tonometria Ocular
15.
Fluids Barriers CNS ; 14(1): 17, 2017 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-28623925

RESUMO

BACKGROUND: Intracranial pressure (ICP) is directly related to cranial dural venous pressure (P dural ). In the upright posture, P dural is affected by the collapse of the internal jugular veins (IJVs) but this regulation of the venous pressure has not been fully understood. A potential biomechanical description of this regulation involves a transmission of surrounding atmospheric pressure to the internal venous pressure of the collapsed IJVs. This can be accomplished if hydrostatic effects are cancelled by the viscous losses in these collapsed veins, resulting in specific IJV cross-sectional areas that can be predicted from flow velocity and vessel inclination. METHODS: We evaluated this potential mechanism in vivo by comparing predicted area to measured IJV area in healthy subjects. Seventeen healthy volunteers (age 45 ± 9 years) were examined using ultrasound to assess IJV area and flow velocity. Ultrasound measurements were performed in supine and sitting positions. RESULTS: IJV area was 94.5 mm2 in supine and decreased to 6.5 ± 5.1 mm2 in sitting position, which agreed with the predicted IJV area of 8.7 ± 5.2 mm2 (equivalence limit ±5 mm2, one-sided t tests, p = 0.03, 33 IJVs). CONCLUSIONS: The agreement between predicted and measured IJV area in sitting supports the occurrence of a hydrostatic-viscous pressure balance in the IJVs, which would result in a constant pressure segment in these collapsed veins, corresponding to a zero transmural pressure. This balance could thus serve as the mechanism by which collapse of the IJVs regulates P dural and consequently ICP in the upright posture.


Assuntos
Pressão Venosa Central/fisiologia , Veias Jugulares/fisiopatologia , Postura , Choque/patologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiologia , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelos Cardiovasculares , Choque/diagnóstico por imagem , Ultrassonografia
16.
J Neurosurg ; 126(5): 1629-1640, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27419825

RESUMO

OBJECT Intracranial pressure (ICP) pulsations are generally considered a passive result of the pulsatility of blood flow. Active experimental modification of ICP pulsations would allow investigation of potential active effects on blood and CSF flow and potentially create a new platform for the treatment of acute and chronic low blood flow states as well as a method of CSF substance clearance and delivery. This study presents a novel method and device for altering the ICP waveform via cardiac-gated volume changes. METHODS The novel device used in this experiment (named Cadence) consists of a small air-filled inelastic balloon (approximately 1.0 ml) implanted into the intracranial space and connected to an external programmable pump, triggered by an R-wave detector. Balloons were implanted into the epidural space above 1 of the hemispheres of 19 canines for up to 10 hours. When activated, the balloons were programed to cyclically inflate with the cardiac cycle with variable delay, phase, and volume. The ICP response was measured in both hemispheres. Additionally, cerebral blood flow (heat diffusion and laser Doppler) was studied in 16 canines. RESULTS This system, depending on the inflation pattern of the balloon, allowed a flattening of the ICP waveform, increase in the ICP waveform amplitude, or phase shift of the wave. This occurred with small mean ICP changes, typically around ± 2 mm Hg (15%). Bilateral ICP effects were observed with activation of the device: balloon inflation at each systole increased the systolic ICP pulse (up to 16 mm Hg, 1200%) and deflation at systole decreased or even inverted the systolic ICP pulse (-0.5 to -19 mm Hg, -5% to -1600%) in a dose-(balloon volume) dependent fashion. No aphysiological or deleterious effects on systemic pressure (≤ ±10 mm Hg; 13% change in mean pressure) or cardiac rate (≤ ± 17 beats per minute; 16% change) were observed during up to 4 hours of balloon activity. CONCLUSIONS The results of these initial studies using an intracranially implanted, cardiac-gated, volume-oscillating balloon suggest the Cadence device can be used to modify ICP pulsations, without physiologically deleterious effects on mean ICP, systemic vascular effects, or brain injury. This device and technique may be used to study the role of ICP pulsatility in intracranial hemo- and hydrodynamic processes and introduces the creation of a potential platform of a cardiac-gated system for treatment of acute and chronic low blood flow states, and diseases requiring augmentation of CSF substance clearance or delivery.


Assuntos
Oclusão com Balão/instrumentação , Circulação Cerebrovascular/fisiologia , Pressão Intracraniana/fisiologia , Animais , Pressão Sanguínea/fisiologia , Volume Sanguíneo/fisiologia , Cães , Fluxometria por Laser-Doppler , Masculino
17.
Ann Neurol ; 80(2): 269-76, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27352140

RESUMO

OBJECTIVE: The discovery of a posture-dependent effect on the difference between intraocular pressure (IOP) and intracranial pressure (ICP) at the level of lamina cribrosa could have important implications for understanding glaucoma and idiopathic intracranial hypertension and could help explain visual impairments in astronauts exposed to microgravity. The aim of this study was to determine the postural influence on the difference between simultaneously measured ICP and IOP. METHODS: Eleven healthy adult volunteers (age = 46 ± 10 years) were investigated with simultaneous ICP, assessed through lumbar puncture, and IOP measurements when supine, sitting, and in 9° head-down tilt (HDT). The trans-lamina cribrosa pressure difference (TLCPD) was calculated as the difference between the IOP and ICP. To estimate the pressures at the lamina cribrosa, geometrical distances were estimated from magnetic resonance imaging and used to adjust for hydrostatic effects. RESULTS: The TLCPD (in millimeters of mercury) between IOP and ICP was 12.3 ± 2.2 for supine, 19.8 ± 4.6 for sitting, and 6.6 ± 2.5 for HDT. The expected 24-hour average TLCPD on earth-assuming 8 hours supine and 16 hours upright-was estimated to be 17.3mmHg. By removing the hydrostatic effects on pressure, a corresponding 24-hour average TLCPD in microgravity environment was simulated to be 6.7mmHg. INTERPRETATION: We provide a possible physiological explanation for how microgravity can cause symptoms similar to those seen in patients with elevated ICP. The observed posture dependency of TLCPD also implies that assessment of the difference between IOP and ICP in upright position may offer new understanding of the pathophysiology of idiopathic intracranial hypertension and glaucoma. Ann Neurol 2016;80:269-276.


Assuntos
Pressão Intracraniana/fisiologia , Pressão Intraocular/fisiologia , Postura/fisiologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neuroimagem
18.
J Neurol Neurosurg Psychiatry ; 86(2): 222-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24963125

RESUMO

BACKGROUND: The association between intracranial pressure (ICP) and different shunt valve opening pressures in relation to body positions is fundamental for understanding the physiological function of the shunt. OBJECTIVE: To analyse the ICP and ICP wave amplitude (AMP) at different shunt settings and body positions in patients with hydrocephalus. METHODS: In this prospective study 15 patients with communicating hydrocephalus were implanted with a ligated adjustable ventriculoperitoneal shunt. They also received a portable intraparenchymatous ICP-monitoring device. Postoperative ICP and AMP were recorded with the patients in three different body positions (supine, sitting and walking) and with the shunt ligated and open at high, medium and low valve settings. In each patient 12 10 min segments were coded, blinded and analysed for mean ICP and mean AMP using an automated computer algorithm. RESULTS: Mean ICP and mean AMP were lower at all three valve settings compared with the ligated shunt state (p<0.001). Overall, when compared with the supine position, mean ICP was 11.5±1.1 (mean±SD) mm Hg lower when sitting and 10.5±1.1 mm Hg lower when walking (p<0.001). Mean ICP was overall 1.1 mm Hg higher (p=0.042) when walking compared with sitting. The maximal adjustability difference (highest vs lowest valve setting) was 4.4 mm Hg. CONCLUSIONS: Changing from a supine to an upright position reduced ICP while AMP only increased at trend level. Lowering of the shunt valve opening pressure decreased ICP and AMP but the difference in mean ICP in vivo between the highest and lowest opening pressures was less than half that previously observed in vitro.


Assuntos
Hidrocefalia/fisiopatologia , Hidrocefalia/cirurgia , Pressão Intracraniana/fisiologia , Postura/fisiologia , Derivação Ventriculoperitoneal , Caminhada/fisiologia , Idoso , Feminino , Humanos , Masculino , Telemetria
19.
Med Biol Eng Comput ; 52(1): 75-85, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24151060

RESUMO

Disturbed cerebrospinal fluid (CSF) dynamics are part of the pathophysiology of normal pressure hydrocephalus (NPH) and can be modified and treated with shunt surgery. This study investigated the contribution of established CSF dynamic parameters to AMP(mean), a prognostic variable defined as mean amplitude of cardiac-related intracranial pressure pulsations during 10 min of lumbar constant infusion, with the aim of clarifying the physiological interpretation of the variable. AMP(mean) and CSF dynamic parameters were determined from infusion tests performed on 18 patients with suspected NPH. Using a mathematical model of CSF dynamics, an expression for AMP(mean) was derived and the influence of the different parameters was assessed. There was high correlation between modelled and measured AMP(mean) (r = 0.98, p < 0.01). Outflow resistance and three parameters relating to compliance were identified from the model. Correlation analysis of patient data confirmed the effect of the parameters on AMP(mean) (Spearman's ρ = 0.58-0.88, p < 0.05). Simulated variations of ±1 standard deviation (SD) of the parameters resulted in AMP(mean) changes of 0.6-2.9 SD, with the elastance coefficient showing the strongest influence. Parameters relating to compliance showed the largest contribution to AMP(mean), which supports the importance of the compliance aspect of CSF dynamics for the understanding of the pathophysiology of NPH.


Assuntos
Pressão do Líquido Cefalorraquidiano/fisiologia , Líquido Cefalorraquidiano/fisiologia , Hidrocefalia de Pressão Normal/líquido cefalorraquidiano , Hidrocefalia de Pressão Normal/fisiopatologia , Infusões Parenterais/métodos , Derivações do Líquido Cefalorraquidiano/métodos , Humanos , Modelos Teóricos
20.
J Appl Physiol (1985) ; 115(10): 1474-80, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24052030

RESUMO

The physiological effect of posture on intracranial pressure (ICP) is not well described. This study defined and evaluated three mathematical models describing the postural effects on ICP, designed to predict ICP at different head-up tilt angles from the supine ICP value. Model I was based on a hydrostatic indifference point for the cerebrospinal fluid (CSF) system, i.e., the existence of a point in the system where pressure is independent of body position. Models II and III were based on Davson's equation for CSF absorption, which relates ICP to venous pressure, and postulated that gravitational effects within the venous system are transferred to the CSF system. Model II assumed a fully communicating venous system, and model III assumed that collapse of the jugular veins at higher tilt angles creates two separate hydrostatic compartments. Evaluation of the models was based on ICP measurements at seven tilt angles (0-71°) in 27 normal pressure hydrocephalus patients. ICP decreased with tilt angle (ANOVA: P < 0.01). The reduction was well predicted by model III (ANOVA lack-of-fit: P = 0.65), which showed excellent fit against measured ICP. Neither model I nor II adequately described the reduction in ICP (ANOVA lack-of-fit: P < 0.01). Postural changes in ICP could not be predicted based on the currently accepted theory of a hydrostatic indifference point for the CSF system, but a new model combining Davson's equation for CSF absorption and hydrostatic gradients in a collapsible venous system performed well and can be useful in future research on gravity and CSF physiology.


Assuntos
Pressão Intracraniana , Veias Jugulares/fisiologia , Modelos Cardiovasculares , Postura , Absorção , Adaptação Fisiológica , Líquido Cefalorraquidiano/metabolismo , Cavidades Cranianas/fisiologia , Gravitação , Humanos , Pressão Hidrostática , Decúbito Dorsal , Pressão Venosa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...