RESUMO
Recent literature indicates that torsion of the left ventricle (LV) is a promising predictor for response to cardiac resynchronisation therapy (CRT). Among patients with severe heart failure, 45 to 75% of patients show rigid body rotation, where the base and apex rotate in the same direction, instead of normal, opposite rotation. The occurrence of this phenomenon seems to be a good indicator for response to CRT. From this review, it can be concluded that LV torsion might be a welcome addition to current selection criteria.
RESUMO
New developments and expanding indications have resulted in a significant increase in the number of patients with pacemakers and internal cardioverterdefibrillators (ICDs). Because of its unique capabilities, magnetic resonance imaging (MRI) has become one of the most important imaging modalities for evaluation of the central nervous system, tumours, musculoskeletal disorders and some cardiovascular diseases. As a consequence of these developments, an increasing number of patients with implanted devices meet the standard indications for MRI examination. Due to the presence of potential life-threatening risks and interactions, however, pacemakers and ICDs are currently not approved by the Food and Drug Administration (FDA) for use in an MRI scanner. Despite these limitations and restrictions, a limited but still growing number of studies reporting on the effects and safety issues of MRI and implanted devices have been published. Because physicians will be increasingly confronted with the issue of MRI in patients with implanted devices, this overview is given. The effects of MRI on an implanted pacemaker and/or ICDs and vice versa are described and, based on the current literature, a strategy for safe performance of MRI in these patients is proposed. (Neth Heart J 2010;18:31-7.).
RESUMO
AIMS: One-third of dilated cardiomyopathy patients receiving a biventricular pacing-device do not respond to this form of therapy. Therefore, the utility of mechanical dyssynchrony by real-time 3D echocardiography (RT3DE) for predicting systolic response to biventricular pacing, of which maximal rate of pressure rise (dP/dt(max)) served as the gold-standard, was evaluated. METHODS AND RESULTS: Seventeen consecutive heart failure patients (aged 64 +/- 10 years, 8 male, 6 ischaemic cardiomyopathy, mean QRS duration 136 +/- 32 ms) underwent RT3DE and biventricular pacing. Post-processing software provided data of global left ventricular (LV) function and the systolic dyssynchrony index of 17 LV segments (SDI(17), %) for mechanical dyssynchrony. During biventricular pacing, percentual change in dP/dt(max) compared to the non-pacing mode, DeltadP/dt(max) was measured invasively with conductance catheters. LV ejection fraction was 31 +/- 10%, SDI(17) was 10.2 +/- 4.2% and percentual DeltadP/dt(max) during biventricular pacing was 14.5 +/- 12.4. A significant correlation (r = 0.729, P = 0.001) was found between SDI(17) and percentual DeltadP/dt(max), and between QRS duration and percentual DeltadP/dt(max) (r = 0.721, P = 0.001). CONCLUSION: The present study suggests that mechanical dyssynchrony measured by RT3DE shows a good correlation with invasively determined acute haemodynamic response to biventricular pacing in patients with symptomatic dilated cardiomyopathy. Future studies are needed to further define the clinical utility of RT3DE in identifying patients who are most likely to respond to cardiac resynchronization therapy.