Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Foot Ankle Int ; 36(12): 1475-82, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26219908

RESUMO

BACKGROUND: Operative management of chronic exertional compartment syndrome of the tibialis anterior muscle compartment (ant-CECS) usually involves the use of a fasciotome. Collateral tissue damage such as hematoma and nerve damage may occur during the procedure. The current report assessed the feasibility and safety of an alternative tool for the operative management of ant-CECS. METHODS: The system had a speculum-like hollow tube that was inserted via a 2-cm skin incision and allowed for the protected advancement of a fasciotome. The device was tested in patients with bilateral ant-CECS. Symptoms were prospectively scored before and after surgery using a 5-category verbal rating scale (VRS). Fourteen patients (age 26 ± 10 years) were analyzed. Complications and operative efficacy were determined using physical examination and questionnaires after 21 (range = 16-25) months. RESULTS: Technical operative success rate was 100% (28/28 legs). Operation time was 10 ± 2 minutes per leg (range = 6-14). Perioperative complications were not observed. One superficial wound infection was treated nonoperatively. Significant reductions in pain (-2.2 ± 1.1 on 5-point VRS, P < .001), tightness (-1.9 ± 1.6, P = .01), cramps (-1.4 ± 1.6, P = .009), muscle weakness (-1.6 ± 1.2, P < .001), and altered sensibility (-1.3 ± 1.4, P = .005) were registered 21 months postoperatively. CONCLUSION: This fasciotome was simple to use and allowed for a safe fasciotomy in patients with leg ant-CECS. A randomized controlled trial comparing the present device with a widely used fasciotome was under way at the time of writing of this study.


Assuntos
Síndromes Compartimentais/cirurgia , Fasciotomia , Extremidade Inferior/cirurgia , Instrumentos Cirúrgicos , Adolescente , Adulto , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Segurança do Paciente , Satisfação do Paciente , Esforço Físico , Volta ao Esporte , Adulto Jovem
2.
J Vasc Surg ; 45(5): 968-73, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17376642

RESUMO

BACKGROUND: A hemodialysis arteriovenous fistula (AVF) requires surgical modification in patients with cardiac overload or dialysis access-associated steal syndrome (DASS). Creation of an artificial stenosis (banding) within the AVF may be used, but this technique lacks the guidance of objective parameters. The aim of this pilot study was to identify indicators that reflect AVF flow in dialysis patients with either access-related cardiac overload (CO) or DASS requiring corrective surgery. METHODS: Patients underwent serial measurements of subclavian venous saturation (Sat(ven)), access flow (Flow(us)), and index digital pressures (P(dig)) during a corrective banding procedure. RESULTS: Data were obtained in 14 individuals (9 men; mean age, 53 +/- 6 years) during 16 studies (CO, n = 8; DASS, n = 8). Before surgery, correlations between preoperative flow, Sat(ven) and P(dig) were not significant. Stepwise banding of the AVF altered Sat(ven) in both groups from a mean of 91% +/- 1% (open AVF) to 84% +/- 2% (closed AVF, P < .001). The CO patients demonstrated a larger drop (-13%) compared with the DASS patients (-4%). Values of P(dig) increased from 68 +/- 9 to 90 +/- 9 mm Hg (P < .001), and both groups demonstrated a similar +23 mm Hg increase. In concert, the digital brachial index also significantly improved in all patients from 0.60% +/- 0.09% to 0.74% +/- 0.10%. Linearity was present between alterations in Flow(us) and Sat(ven) in all patients, but mostly in the CO patients (r(2) = 0.96). CONCLUSIONS: Stepwise banding of hemodialysis fistulas leads to dose-dependent decreases in flow and ipsilateral subclavian venous saturation combined with augmented digital pressures in patients with cardiac overload and dialysis associated steal syndrome. Intraoperative measurements of venous saturation and digital pressures may have the potential of guiding surgical correction in these patients.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Débito Cardíaco Elevado/etiologia , Isquemia/etiologia , Diálise Renal , Adulto , Braço/irrigação sanguínea , Derivação Arteriovenosa Cirúrgica/métodos , Feminino , Mãos/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Pletismografia , Polietilenotereftalatos , Fluxo Sanguíneo Regional , Veia Subclávia/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA