Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38457321

RESUMO

We present a mm-sized, ultrasonically powered lensless CMOS image sensor as a progress towards wireless fluorescence microscopy. Access to biological information within the tissue has the potential to provide insights guiding diagnosis and treatment across numerous medical conditions including cancer therapy. This information, in conjunction with current clinical imaging techniques that have limitations in obtaining images continuously and lack wireless compatibility, can improve continual detection of multicell clusters deep within tissue. The proposed platform incorporates a 2.4×4.7 mm2 integrated circuit (IC) fabricated in TSMC 0.18 µm, a micro laser diode (µLD), a single piezoceramic and off-chip storage capacitors. The IC consists of a 36×40 array of capacitive trans-impedance amplifier-based pixels, wireless power management and communication via ultrasound and a laser driver all controlled by a Finite State Machine. The piezoceramic harvests energy from the acoustic waves at a depth of 2 cm to power up the IC and transfer 11.5 kbits/frame via backscattering. During Charge-Up, the off-chip capacitor stores charge to later supply a high-power 78 mW µLD during Imaging. Proof of concept of the imaging front end is shown by imaging distributions of CD8 T-cells, an indicator of the immune response to cancer, ex vivo, in the lymph nodes of a functional immune system (BL6 mice) against colorectal cancer consistent with the results of a fluorescence microscope. The overall system performance is verified by detecting 140 µm features on a USAF resolution target with 32 ms exposure time and 389 ms ultrasound backscattering.

2.
Biomed Opt Express ; 15(3): 1761-1776, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38495694

RESUMO

In curative-intent cancer surgery, intraoperative fluorescence imaging of both diseased and healthy tissue can help to ensure the successful removal of all gross and microscopic diseases with minimal damage to neighboring critical structures, such as nerves. Current fluorescence-guided surgery (FGS) systems, however, rely on bulky and rigid optics that incur performance-limiting trade-offs between sensitivity and maneuverability. Moreover, many FGS systems are incapable of multiplexed imaging. As a result, clinical FGS is currently limited to millimeter-scale detection of a single fluorescent target. Here, we present a scalable, lens-less fluorescence imaging chip, VISION, capable of sensitive and multiplexed detection within a compact form factor. Central to VISION is a novel optical frontend design combining a low-numerical-aperture fiber optic plate (LNA-FOP) and a multi-bandpass interference filter, which is affixed to a custom CMOS image sensor. The LNA-FOP acts as a planar collimator to improve resolution and compensate for the angle-sensitivity of the interference filter, enabling high-resolution and multiplexed fluorescence imaging without lenses. We show VISION is capable of detecting tumor foci of less than 100 cells at near video framerates and, as proof of principle, can simultaneously visualize both tumors and nerves in ex vivo prostate tissue.

3.
bioRxiv ; 2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-37904924

RESUMO

In curative-intent cancer surgery, intraoperative fluorescence imaging of both diseased and healthy tissue can help to ensure successful removal of all gross and microscopic disease with minimal damage to neighboring critical structures, such as nerves. Current fluorescence-guided surgery (FGS) systems, however, rely on bulky and rigid optics that incur performance-limiting trade-offs between sensitivity and maneuverability. Moreover, many FGS systems are incapable of multiplexed imaging. As a result, clinical FGS is currently limited to millimeter-scale detection of a single fluorescent target. Here we present a scalable, lens-less fluorescence imaging chip, VISION, capable of sensitive and multiplexed detection within a compact form factor. Central to VISION is a novel optical frontend design combining a low-numerical-aperture fiber optic plate (LNA-FOP) and a multi-bandpass interference filter, which is affixed to a custom CMOS image sensor. The LNA-FOP acts as a planar collimator to improve resolution and compensate for the angle-sensitivity of the interference filter, enabling high-resolution and multiplexed fluorescence imaging without lenses. We show VISION is capable of detecting tumor foci of less than 100 cells at near video framerates and, as proof of principle, can simultaneously visualize both tumor and nerves in ex vivo prostate tissue.

4.
bioRxiv ; 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38106190

RESUMO

We present a mm-sized, ultrasonically powered lensless CMOS image sensor as a progress towards wireless fluorescence microscopy. Access to biological information within the tissue has the potential to provide insights guiding diagnosis and treatment across numerous medical conditions including cancer therapy. This information, in conjunction with current clinical imaging techniques that have limitations in obtaining images continuously and lack wireless compatibility, can improve continual detection of multicell clusters deep within tissue. The proposed platform incorporates a 2.4×4.7 mm2 integrated circuit (IC) fabricated in TSMC 0.18 µm, a micro laser diode (µLD), a single piezoceramic and off-chip storage capacitors. The IC consists of a 36×40 array of capacitive trans-impedance amplifier-based pixels, wireless power management and communication via ultrasound and a laser driver all controlled by a Finite State Machine. The piezoceramic harvests energy from the acoustic waves at a depth of 2 cm to power up the IC and transfer 11.5 kbits/frame via backscattering. During Charge-Up, the off-chip capacitor stores charge to later supply a high-power 78 mW µLD during Imaging. Proof of concept of the imaging front end is shown by imaging distributions of CD8 T-cells, an indicator of the immune response to cancer, ex vivo, in the lymph nodes of a functional immune system (BL6 mice) against colorectal cancer consistent with the results of a fluorescence microscope. The overall system performance is verified by detecting 140 µm features on a USAF resolution target with 32 ms exposure time and 389 ms ultrasound backscattering.

5.
Sci Rep ; 12(1): 7229, 2022 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-35508477

RESUMO

Millimeter-scale multi-cellular level imagers enable various applications, ranging from intraoperative surgical navigation to implantable sensors. However, the tradeoffs for miniaturization compromise resolution, making extracting 3D cell locations challenging-critical for tumor margin assessment and therapy monitoring. This work presents three machine-learning-based modules that extract spatial information from single image acquisitions using custom-made millimeter-scale imagers. The neural networks were trained on synthetically-generated (using Perlin noise) cell images. The first network is a convolutional neural network estimating the depth of a single layer of cells, the second is a deblurring module correcting for the point spread function (PSF). The final module extracts spatial information from a single image acquisition of a 3D specimen and reconstructs cross-sections, by providing a layered "map" of cell locations. The maximum depth error of the first module is 100 µm, with 87% test accuracy. The second module's PSF correction achieves a least-square-error of only 4%. The third module generates a binary "cell" or "no cell" per-pixel labeling with an accuracy ranging from 89% to 85%. This work demonstrates the synergy between ultra-small silicon-based imagers that enable in vivo imaging but face a trade-off in spatial resolution, and the processing power of neural networks to achieve enhancements beyond conventional linear optimization techniques.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Processamento de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Redes Neurais de Computação
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 7399-7403, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892807

RESUMO

Real-time monitoring of cellular-level changes inside the body provides key information regarding disease progression and therapy assessment for critical care including cancer therapy. Current state-of-the-art oncological imaging methods impose unnecessary latencies to detect small cell foci. Invasive methods such as biopsies, on the other hand, cause disruption if deployed on a repeated basis. Therefore, they are not practical for real-time assessments of the tumor tissue. This work presents a proof-of-concept design for an implantable fluorescence lensless image sensor to address the pervasive challenge of real-time tracking of the immune response in immunotherapy. The 2.4x4.7 mm2 integrated circuit (IC) prototype consists of a 36 by 40 pixel array, a laser driver and a power management unit harvesting power and transferring 11.5 kbits/frame through a wireless ultrasound link while implanted 2 cm deep inside the body. Compared to prior art, this is the first full-fledged wireless system implementing chip-scale fluorescence microscopy to the best of our knowledge.Clinical relevance- This prototype can be used to personalize immunotherapy for the 50% of cancer patients who do not initially respond to the therapy.


Assuntos
Neoplasias , Próteses e Implantes , Fluorescência , Humanos , Imunidade , Neoplasias/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...