Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Pediatr Res ; 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702380

RESUMO

Neonatology is a pediatric sub-discipline focused on providing care for newborn infants, including healthy newborns, those born prematurely, and those who present with illnesses or malformations requiring medical care. The European Training Requirements (ETR) in Neonatology provide a framework for standardized quality and recognition of equality of training throughout Europe. The latest ETR version was approved by the Union of European Medical Specialists (UEMS) in April 2021. Here, we present the curriculum of the European School of Neonatology Master of Advanced Studies (ESN MAS), which is based on the ETR in Neonatology and aims to provide a model for effective and standardized training and education in neonatal medicine. We review the history and theory that form the foundation of contemporary medical education and training, provide a literature review on best practices for medical training, pediatric training, and neonatology training specifically, including educational frameworks and evidence-based systems of evaluation. The ESN MAS Curriculum is then evaluated in light of these best practices to define its role in meeting the need for a standardized empirically supported neonatology training curriculum for physicians, and in the future for nurses, to improve the quality of neonatal care for all infants. IMPACT STATEMENT: A review of the neonatology training literature was conducted, which concluded that there is a need for standardized neonatology training across international contexts to keep pace with growth in the field and rapidly advancing technology. This article presents the European School of Neonatology Master of Advanced Studies in Neonatology, which is intended to provide a standardized training curriculum for pediatricians and nurses seeking sub-specialization in neonatology. The curriculum is evaluated in light of best practices in medical education, neonatology training, and adult learning theory.

2.
Matern Health Neonatol Perinatol ; 10(1): 9, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38689326

RESUMO

BACKGROUND: Blood pressure is a vital hemodynamic marker during the neonatal period. However, normative values are often derived from small observational studies. Understanding the normative range would help to identify ideal thresholds for intervention to treat hypotension or hypertension. Therefore, the aim of this study was to assess observed blood pressure values in neonates who have not received any blood-pressure modifying treatments from birth to three months postnatal age and whether these vary according to birth weight, gestational age and postnatal age. METHODS: This was a systematic review. A literature search was conducted in MEDLINE, PubMed, Embase, Cochrane Library, and CINAHL from 1946 to 2017 on blood pressure in neonates from birth to 3 months of age (PROSPERO ID CRD42018092886). Unpublished data were included where appropriate. RESULTS: Of 3,587 non-duplicate publications identified, 30 were included (one unpublished study). Twelve studies contained data grouped by birth weight, while 23 contained data grouped by gestational age. Study and clinical heterogeneity precluded meta-analyses thus results are presented by subgroup. A consistent blood pressure rise was associated with increasing birth weight, gestational age, and postnatal age. In addition, blood pressure seemed to rise more rapidly in the most preterm and low birth weight neonates. CONCLUSION: Despite blood pressure increasing with birth weight, gestational age, and postnatal age, there was marked blood pressure variability observed throughout. To better define hypotension and hypertension, future studies should develop consistent approaches for factors related to blood pressure variability, including the method and timing of measurement as well as statistical control of relevant patient characteristics.

4.
Pediatr Pulmonol ; 59(1): 19-30, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37690457

RESUMO

INTRODUCTION: Respiratory infections and wheeze have a considerable impact on the health of young children and consume significant healthcare resources. We aimed to evaluate the effect of environmental factors on respiratory infections and symptoms in early childhood. METHODS: Environmental risk factors including: daycare attendance; breastfeeding; siblings; damp within the home; environmental tobacco smoke (ETS); child's bedroom flooring; animal exposure; road traffic density around child's home; and solid fuel pollution within home were assessed in children recruited to the GO-CHILD multicentre prospective birth cohort study. Follow-up information on respiratory infections (bronchiolitis, pneumonia, otitis media and cold or flu), wheeze and cough symptoms, healthcare utilisation and medication prescription was collected by postal questionnaires at 12 and 24 months. Log binomial and ordered logistic regression models were fitted to the data. RESULTS: Follow-up was obtained on 1344 children. Daycare was associated with increased odds of pneumonia (odds ratio [OR] = 2.39, 95% confidence interval [CI]: 1.04-5.49), bronchiolitis (OR = 1.40, 1.02-1.90), otitis media (OR = 1.68, 1.32-2.14) and emergency department attendance for wheeze (RR = 1.81, 1.17-2.80). Breastfeeding beyond 6 months was associated with a reduced odds of bronchiolitis (OR = 0.55, 0.39-0.77) and otitis media (OR = 0.75, 0.59-0.99). Siblings at home was associated with an increased odds of bronchiolitis (OR = 1.65, 1.18-2.32) and risk of reliever inhaler prescription (RR = 1.37, 1.02-1.85). Visible damp was associated with an increased odds of wheeze (OR = 1.85, 1.11-3.19), and risk of reliever inhaler (RR = 1.73, 1.04-2.89) and inhaled corticosteroid prescription (RR = 2.61, 1.03-6.59). ETS exposure was associated with an increased odds of primary care attendance for cough or wheeze (OR = 1.52, 1.11-2.08). Dense traffic around the child's home was associated with an increased odds of bronchiolitis (OR = 1.32, 1.08-2.29). CONCLUSION: Environmental factors likely influence the wide variation in infection frequency and symptoms observed in early childhood. Larger population studies are necessary to further inform and guide public health policy to decrease the burden of respiratory infections and wheeze in young children.


Assuntos
Bronquiolite , Otite Média , Pneumonia , Infecções Respiratórias , Poluição por Fumaça de Tabaco , Animais , Humanos , Pré-Escolar , Estudos de Coortes , Estudos Prospectivos , Fatores de Risco , Infecções Respiratórias/epidemiologia , Infecções Respiratórias/etiologia , Poluição por Fumaça de Tabaco/efeitos adversos , Bronquiolite/complicações , Pneumonia/complicações , Otite Média/epidemiologia , Otite Média/etiologia , Tosse/complicações , Sons Respiratórios/etiologia
5.
Int J Infect Dis ; 137: 63-70, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37839504

RESUMO

OBJECTIVES: At the beginning of the COVID-19 pandemic, delayed umbilical cord clamping (CC) at birth may have been commonly discouraged despite a lack of convincing evidence of mother-to-neonate SARS-CoV-2 transmission. We aimed to systematically review guidelines, and reports of practice and to analyze associations between timing of CC and mother-to-neonate SARS-CoV-2 transmission during the early phases of the pandemic. METHODS: Major databases were searched from December 1, 2019, to July 20, 2021. INCLUSION: studies and guidelines describing CC practice in women with SARS-CoV-2 infection during pregnancy until 2 postnatal days, giving birth to live-born neonates. EXCLUSION: no extractable data. Two reviewers independently screened studies for eligibility and assessed study quality. Pooled prevalence rates were calculated. RESULTS: Forty-eight studies (1476 neonates) and 40 guidelines were included. Delayed CC was recommended in 70.0% of the guidelines. Nevertheless, delayed CC was reported less often than early CC: 262/1476 (17.8%) vs 511/1476 (34.6%). Neonatal SARS-CoV-2 positivity rates were similar following delayed (1.2%) and early CC (1.3%). Most SARS-CoV-2 transmissions (93.3%) occurred in utero. CONCLUSION: Delayed CC did not seem to increase mother-to-neonate SARS-CoV-2 transmission. Due to its benefits, it should be encouraged even in births where the mother has a SARS-CoV-2 infection. SYSTEMATIC REVIEW REGISTRATION: Prospero CRD42020199500.


Assuntos
COVID-19 , Complicações Infecciosas na Gravidez , Recém-Nascido , Gravidez , Feminino , Humanos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Clampeamento do Cordão Umbilical , SARS-CoV-2 , Pandemias , Complicações Infecciosas na Gravidez/epidemiologia , Complicações Infecciosas na Gravidez/prevenção & controle , Transmissão Vertical de Doenças Infecciosas/prevenção & controle
6.
Semin Perinatol ; 47(5): 151791, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37357042

RESUMO

In 2014 the World Health Organisation recommended providing placental blood to all newborn infants by waiting for at least one minute before clamping the umbilical cord. Mounting evidence supports providing a placental transfusion at the time of birth for all infants. The optimal time before clamping and cutting the umbilical cord is still not yet known, and debate exists around other cord management issues. The newborn's transition phase from intra- to extra-uterine life and the effects of blood volume on the many necessary adaptations are understudied. How best to support these adaptations guides our suggested research questions. Parents' perceptions of enrolling their unborn infant into a study play important parts in the conduct of such trials. This article aims to address these topics and suggest research questions for further studies.


Assuntos
Recém-Nascido Prematuro , Placenta , Recém-Nascido , Gravidez , Feminino , Humanos , Transfusão de Sangue , Parto , Cordão Umbilical
7.
Am J Perinatol ; 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37339678

RESUMO

OBJECTIVE: Cerebral sonography (CS) through the anterior fontanelle is a neonatal brain imaging method that has become an integral part of modern neonatal bedside care for both screening and diagnostic purposes. Premature infants with cognitive delay have a reduction in cerebellar size at term corrected age on magnetic resonance imaging (MRI). We aimed to determine the level of agreement between postnatal MRI and CS for cerebellar biometry and to determine the level of agreement within one and between different examiners. STUDY DESIGN: Cerebellar sonography and MRI measurements of the cerebellum from 30 term infants was assessed by Bland-Altman plots. Measurements between both modalities were compared using Wilcoxon's signed rank test. A p-value < 0.01 was considered statistically significant. Intraclass correlation coefficients (ICC) for intra- and interrater reliabilities of CS measurements were calculated. RESULTS: There was no statistically significant difference between CS and MRI for linear measurements, but the measurements of perimeter and surface area differed significantly between the two techniques. There was a systematic bias between both modalities for most measurements except for anterior-posterior (AP) width and vermis height (VH). For measurements that were not statistically different from MRI, we found excellent intrarater ICC for the AP width, VH, and cerebellar width. The interrater ICC was excellent for the AP width and VH, but poor for the transverse cerebellar width. CONCLUSION: With a strict imaging protocol, cerebellar measurements of the AP width and the VH can be used as an alternative to MRI for diagnostic-screening purposes in a neonatal department where multiple clinicians perform bedside CS. KEY POINTS: · Abnormal cerebellar growth and injuries affect neurodevelopmental outcome.. · Cerebral sonography through the anterior fontanelle is used for bedside imaging.. · Postnatal sonographic cerebellar measurements are not validated against MRI.. · Measuring vermis height and anterior-posterior width are reliable.. · Measuring transverse cerebellar width through anterior fontanelle is unreliable..

8.
Children (Basel) ; 10(2)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36832512

RESUMO

Births involving shoulder dystocia or tight nuchal cords can deteriorate rapidly. The fetus may have had a reassuring tracing just before birth yet may be born without any heartbeat (asystole). Since the publication of our first article on cardiac asystole with two cases, five similar cases have been published. We suggest that these infants shift blood to the placenta due to the tight squeeze of the birth canal during the second stage which compresses the cord. The squeeze transfers blood to the placenta via the firm-walled arteries but prevents blood returning to the infant via the soft-walled umbilical vein. These infants may then be born severely hypovolemic resulting in asystole secondary to the loss of blood. Immediate cord clamping (ICC) prevents the newborn's access to this blood after birth. Even if the infant is resuscitated, loss of this large amount of blood volume may initiate an inflammatory response that can enhance neuropathologic processes including seizures, hypoxic-ischemic encephalopathy (HIE), and death. We present the role of the autonomic nervous system in the development of asystole and suggest an alternative algorithm to address the need to provide these infants intact cord resuscitation. Leaving the cord intact (allowing for return of the umbilical cord circulation) for several minutes after birth may allow most of the sequestered blood to return to the infant. Umbilical cord milking may return enough of the blood volume to restart the heart but there are likely reparative functions that are carried out by the placenta during the continued neonatal-placental circulation allowed by an intact cord.

9.
Matern Health Neonatol Perinatol ; 8(1): 9, 2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36414979

RESUMO

BACKGROUND: Reducing the global new-born mortality is a paramount challenge for humanity. There are approximately 786,323 live births in the UK each year according to the office for National Statistics; around 10% of these newborn infants require assistance during this transition after birth. Each year around, globally around 2.5 million newborns die within their first month. The main causes are complications due to prematurity and during delivery. To act in a timely manner and prevent further damage, health professionals should rely on accurate monitoring of the main vital signs heart rate and respiratory rate. AIMS: To present a clinical perspective on innovative, non-invasive methods to monitor heart rate and respiratory rate in babies highlighting their advantages and limitations in comparison with well-established methods. METHODS: Using the data collected in our recently published systematic review we highlight the barriers and facilitators for the novel sensor devices in obtaining reliable heart rate measurements. Details about difficulties related to the application of sensors and interfaces, time to display, and user feedback are explored. We also provide a unique overview of using a non-invasive respiratory rate monitoring method by extracting RR from the pulse oximetry trace of newborn babies. RESULTS: Novel sensors to monitor heart rate offer the advantages of minimally obtrusive technologies but have limitations due to movement artefact, bad sensor coupling, intermittent measurement, and poor-quality recordings compared to gold standard well established methods. Respiratory rate can be derived accurately from pleth recordings in infants. CONCLUSION: Some limitations have been identified in current methods to monitor heart rate and respiratory rate in newborn babies. Novel minimally invasive sensors have advantages that may help clinical practice. Further research studies are needed to assess whether they are sufficiently accurate, practical, and reliable to be suitable for clinical use.

10.
Pediatr Pulmonol ; 57(11): 2824-2833, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35949104

RESUMO

BACKGROUND: Mannose-binding lectin (MBL) is an important component of the innate immune system. Polymorphisms in the MBL2 gene and promoter region are directly associated with MBL-deficiency. We sought to determine the association between MBL genotype on the frequency of common childhood respiratory infections, respiratory symptoms, and atopic outcomes in early childhood. METHODS: MBL2 gene variants were analyzed in newborns recruited to the GO-CHILD multicenter prospective cohort study. Follow-up for respiratory infection and atopy diagnoses and symptoms, healthcare utilization, and medication prescription were conducted by postal questionnaires at 12 and 24 months. RESULTS: Genotyping and follow-up were completed in 1004 children. Genotypes associated with MBL-deficiency were associated with an increased risk of bronchiolitis (relative risk [RR] 1.95, 95% confidence interval [CI] 1.33-2.85) and pneumonia (RR 2.46, 95% CI 1.16-5.22). MBL-deficient genotypes were associated with an increased risk of wheeze with shortness of breath episodes (RR 1.22, 95% CI 1.04-1.43), emergency department attendance (RR 1.90 95% CI 1.13-3.19), and hospital admission (RR 2.01, 95% CI 1.04-3.89) for wheeze. MBL-deficient genotypes were associated with a reduced risk of developing atopic dermatitis (RR 0.72, 95% CI 0.53-0.98). CONCLUSION: The positive association between MBL-deficient genotypes and bronchiolitis and pneumonia, as well as a severe wheeze phenotype in some young children, supports the hypothesis that MBL is an important component of innate immunity in the vulnerable period before the maturation of the adaptive immune system. Identification of disease-modifying genotypes may help target preventative strategies in high-risk infants.


Assuntos
Bronquiolite , Lectina de Ligação a Manose , Transtornos Respiratórios , Infecções Respiratórias , Bronquiolite/genética , Pré-Escolar , Estudos de Coortes , Predisposição Genética para Doença , Genótipo , Humanos , Lectina de Ligação a Manose/deficiência , Lectina de Ligação a Manose/genética , Erros Inatos do Metabolismo , Estudos Prospectivos , Infecções Respiratórias/epidemiologia , Infecções Respiratórias/genética
11.
BMC Pregnancy Childbirth ; 22(1): 593, 2022 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-35883044

RESUMO

BACKGROUND: An intact umbilical cord allows the physiological transfusion of blood from the placenta to the neonate, which reduces infant iron deficiency and is associated with improved development during early childhood. The implementation of delayed cord clamping practice varies depending on mode of delivery, as well as gestational age and neonatal compromise. Emerging evidence shows that infants requiring resuscitation would benefit if respiratory support were provided with the umbilical cord intact. Common barriers to providing intact cord resuscitation is the availability of neonatal resuscitation equipment close to the mother, organizational readiness for change as well as attitudes and beliefs about placental transfusion within the multidisciplinary team. Hence, clinical evaluations of cord clamping practice should include implementation outcomes in order to develop strategies for optimal cord management practice. METHODS: The Sustained cord circulation And Ventilation (SAVE) study is a hybrid type I randomized controlled study combining the evaluation of clinical outcomes with implementation and health service outcomes. In phase I of the study, a method for providing in-bed intact cord resuscitation was developed, in phase II of the study the intervention was adapted to be used in multiple settings. In phase III of the study, a full-scale multicenter study will be initiated with concurrent evaluation of clinical, implementation and health service outcomes. Clinical data on neonatal outcomes will be recorded at the labor and neonatal units. Implementation outcomes will be collected from electronic surveys sent to parents as well as staff and managers within the birth and neonatal units. Descriptive and comparative statistics and regression modelling will be used for analysis. Quantitative data will be supplemented by qualitative methods using a thematic analysis with an inductive approach. DISCUSSION: The SAVE study enables the safe development and evaluation of a method for intact cord resuscitation in a multicenter trial. The study identifies barriers and facilitators for intact cord resuscitation. The knowledge provided from the study will be of benefit for the development of cord clamping practice in different challenging clinical settings and provide evidence for development of clinical guidelines regarding optimal cord clamping. TRIAL REGISTRATION: Clinicaltrials.gov, NCT04070560 . Registered 28 August 2019.


Assuntos
Recém-Nascido Prematuro , Ressuscitação , Pré-Escolar , Feminino , Serviços de Saúde , Humanos , Lactente , Recém-Nascido , Estudos Multicêntricos como Assunto , Placenta , Gravidez , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Cordão Umbilical
13.
Early Hum Dev ; 169: 105579, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35561518

RESUMO

Echocardiography was combined with pulse oximetry plethysmography to investigate postnatal cardiovascular adaptation in late preterm and term infants. Median (IQR) pleth variability decreased over three days and similar, day2 15%(12-18%) preterm versus 16%(15-18%) term infants. Median (IQR) pulse transit time heart rate normalised was lower in term babies, day2 0.55(0.51-0.63) versus 0.64(0.62-0.68).


Assuntos
Coração , Oximetria , Ecocardiografia , Frequência Cardíaca/fisiologia , Humanos , Lactente , Recém-Nascido , Oximetria/métodos , Estudos Prospectivos
14.
Children (Basel) ; 9(4)2022 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-35455560

RESUMO

We use a case of intact cord resuscitation to argue for the beneficial effects of an enhanced blood volume from placental transfusion for newborns needing resuscitation. We propose that intact cord resuscitation supports the process of physiologic neonatal transition, especially for many of those newborns appearing moribund. Transfer of the residual blood in the placenta provides the neonate with valuable access to otherwise lost blood volume while changing from placental respiration to breathing air. Our hypothesis is that the enhanced blood flow from placental transfusion initiates mechanical and chemical forces that directly, and indirectly through the vagus nerve, cause vasodilatation in the lung. Pulmonary vascular resistance is thereby reduced and facilitates the important increased entry of blood into the alveolar capillaries before breathing commences. In the presented case, enhanced perfusion to the brain by way of an intact cord likely led to regained consciousness, initiation of breathing, and return of tone and reflexes minutes after birth. Paramount to our hypothesis is the importance of keeping the umbilical cord circulation intact during the first several minutes of life to accommodate physiologic neonatal transition for all newborns and especially for those most compromised infants.

15.
Eur J Pediatr ; 181(5): 1797-1807, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35112135

RESUMO

A newborn who receives a placental transfusion at birth from delayed cord clamping (DCC) obtains about 30% more blood volume than those with immediate cord clamping (ICC). Benefits for term neonates include higher hemoglobin levels, less iron deficiency in infancy, improved myelination out to 12 months, and better motor and social development at 4 years of age especially in boys. For preterm infants, benefits include less intraventricular hemorrhage, fewer gastrointestinal issues, lower transfusion requirements, and less mortality in the neonatal intensive care unit by 30%. Ventilation before clamping the umbilical cord can reduce large swings in cardiovascular function and help to stabilize the neonate. Hypovolemia, often associated with nuchal cord or shoulder dystocia, may lead to an inflammatory cascade and subsequent ischemic injury. A sudden unexpected neonatal asystole at birth may occur from severe hypovolemia. The restoration of blood volume is an important action to protect the hearts and brains of neonates. Currently, protocols for resuscitation call for ICC. However, receiving an adequate blood volume via placental transfusion may be protective for distressed neonates as it prevents hypovolemia and supports optimal perfusion to all organs. Bringing the resuscitation to the mother's bedside is a novel concept and supports an intact umbilical cord. When one cannot wait, cord milking several times can be done quickly within the resuscitation guidelines. Cord blood gases can be collected with optimal cord management.   Conclusion: Adopting a policy for resuscitation with an intact cord in a hospital setting takes a coordinated effort and requires teamwork by obstetrics, pediatrics, midwifery, and nursing.


Assuntos
Hipovolemia , Recém-Nascido Prematuro , Criança , Constrição , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Placenta , Gravidez , Cordão Umbilical
17.
Eur J Pediatr ; 181(3): 1117-1124, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34748081

RESUMO

Monitoring patent ductus arteriosus (PDA) in premature infants is currently performed intermittently using echocardiography which requires considerable expertise. The aim of this pilot study was to investigate whether PDA status could be assessed from standard neonatal intensive care monitoring. Electrocardiography (ECG) and blood pressure (BP) waveforms were acquired from extremely preterm infants using standard neonatal monitors. We developed software using MATLAB to analyse ECG and BP waveforms and their interrelationships in terms of pulse transit time (PTT) and pulse wave velocity (PWV). The times from peak systolic BP to diastolic trough (BPFt) and from the diastolic trough to peak systolic BP (BPRt) were also calculated. PTT, BPFt and BPRt were normalised for heart rate (HR) termed NPTT, NBPFt and NBPRt, respectively. ECG, invasive aortic BP monitoring and echocardiography were performed in 14 preterm infants < 29 weeks' gestation in the first 3 days after birth. The median (range) birth weight of the infants was 0.90 (0.48-1.31) kg, gestation 26.6 (24.0-28.7) weeks, PDA diameter 1.6 (0.8-3.6) mm and mean BP 32 (16-40) mmHg. We found a significant positive correlation between PDA diameter and NPTT (r = 0.69, P = 0.007) as well as NBPFt (r = 0.65, P = 0.012) and NBPRt (r = 0.71, P = 0.005). No relationship was found between PDA diameter and pulse pressure.Conclusions: Interrelationships between ECG and BP traces as well as BP waveform time analysis are straightforward to measure and associated with PDA diameter. The results of this pilot study suggest that this approach may help provide biomarkers for continuous monitoring PDA diameter and function. What is Known: • Patent ductus arteriosus (PDA) in premature infants is associated with increased risk of developing chronic lung disease, necrotising enterocolitis and cerebral injury. • Currently PDA is assessed intermittently using echocardiography which requires considerable expertise and sometimes is not well tolerated by critically ill preterm infants. What is New: • Blood pressure (BP) and ECG waveform interrelation and BP trace time analysis, taking account of heart rate, relate to PDA diameter. • ECG and BP waveform phase difference as well as BP waveform time analysis may be useful in the continuous assessment of PDA function.


Assuntos
Permeabilidade do Canal Arterial , Permeabilidade do Canal Arterial/diagnóstico por imagem , Humanos , Ibuprofeno/uso terapêutico , Lactente , Lactente Extremamente Prematuro , Recém-Nascido , Terapia Intensiva Neonatal , Projetos Piloto , Análise de Onda de Pulso
18.
J Perinatol ; 41(9): 2317-2329, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34365475

RESUMO

OBJECTIVE: A comprehensive understanding of the factors contributing to perinatal blood pressure is vital to ensure optimal postnatal hemodynamic support. The objective of this study was to review existing literature on maternal and perinatal factors influencing blood pressure in neonates up to 3 months corrected age. METHODS: A systematic search of published literature in OVID Medline, OVID Embase and the COCHRANE library identified publications relating to maternal factors affecting blood pressure of neonates up to corrected age of 3 months. Summary data were extracted and compared (PROSPERO CRD42018092886). RESULTS: Of the 3683 non-duplicate publications identified, 44 were eligible for inclusion in this review. Topics elicited were sociodemographic factors, maternal health status, medications, smoking during pregnancy, and cord management at birth. Limited data were available for each factor. Results regarding the impact of these factors on neonatal blood pressure were inconsistent across studies. CONCLUSIONS: There is insufficient evidence to draw definitive conclusions regarding the impact of various maternal and perinatal factors on neonatal blood pressure. Future investigations of neonatal cardiovascular therapies should account for these factors in their study design. Similarly, studies on maternal diseases and perinatal interventions should include neonatal blood pressure as part of their primary or secondary analyses.


Assuntos
Pressão Sanguínea , Feminino , Humanos , Lactente , Recém-Nascido , Gravidez
19.
J Perinatol ; 41(6): 1495-1504, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33850284

RESUMO

Placental transfusion results in a significant decrease in the risk of death for extremely preterm infants. With immediate cord clamping (ICC), these infants can leave up to one-half of their normal circulating in utero blood volume in the placenta. Extremely preterm infants are at highest risk of harm from ICC yet are currently the most likely to receive ICC. Receiving a placenta transfusion provides infants with life-saving components and enhanced perfusion. We present some lesser-known but important effects of placental transfusion. New research reveals that enhanced vascular perfusion causes an organ's endothelial cells to release angiocrine responses to guide essential functions. High progesterone levels and pulmonary artery pressure in the first few hours of life assist with neonatal adaptation. We propose that lack of essential blood volume may be a major factor contributing to inflammation, morbidities, and mortality that preterm infants frequently encounter.


Assuntos
Células Endoteliais , Placenta , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Gravidez
20.
Sensors (Basel) ; 21(3)2021 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-33540669

RESUMO

Heart rate monitoring is the predominant quantitative health indicator of a newborn in the delivery room. A rapid and accurate heart rate measurement is vital during the first minutes after birth. Clinical recommendations suggest that electrocardiogram (ECG) monitoring should be widely adopted in the neonatal intensive care unit to reduce infant mortality and improve long term health outcomes in births that require intervention. Novel non-contact electrocardiogram sensors can reduce the time from birth to heart rate reading as well as providing unobtrusive and continuous monitoring during intervention. In this work we report the design and development of a solution to provide high resolution, real time electrocardiogram data to the clinicians within the delivery room using non-contact electric potential sensors embedded in a neonatal intensive care unit mattress. A real-time high-resolution electrocardiogram acquisition solution based on a low power embedded system was developed and textile embedded electrodes were fabricated and characterised. Proof of concept tests were carried out on simulated and human cardiac signals, producing electrocardiograms suitable for the calculation of heart rate having an accuracy within ±1 beat per minute using a test ECG signal, ECG recordings from a human volunteer with a correlation coefficient of ~ 87% proved accurate beat to beat morphology reproduction of the waveform without morphological alterations and a time from application to heart rate display below 6 s. This provides evidence that flexible non-contact textile-based electrodes can be embedded in wearable devices for assisting births through heart rate monitoring and serves as a proof of concept for a complete neonate electrocardiogram monitoring system.


Assuntos
Leitos , Eletrocardiografia , Monitorização Fisiológica , Dispositivos Eletrônicos Vestíveis , Eletrodos , Humanos , Recém-Nascido , Têxteis
SELEÇÃO DE REFERÊNCIAS