Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Ultrasound ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38900364

RESUMO

A 62-year-old woman, with neuropathic pain and paresthesia in her right forefoot, showed a circumscribed soft tissue swelling on the sole between the second and third metatarsal. Ultrasound (US) imaging showed a well-defined lesion in the second intermetatarsal space, without vascularization sign at Power Doppler (PD). In the first hypothesis, these findings led to Morton's neuroma. Magnetic Resonance Imaging (MRI), demonstrated a dumbbell-shaped lesion between the II and the III metatarsal heads; it extended cranially to the subcutaneous fat of the dorsal slope. The MRI findings weren't compatible with a classic Morton's neuroma and were radiologically undetectable. The patient had a sub-total excisional biopsy. The anatomopathological features were specific to an apocrine hydroadenoma from an ectopic sweat gland. This rare pathology has not been previously described in the literature and it must be considered as a differential diagnosis due to the clinical presentation and the US appearance mimicking Morton's neuroma.

2.
Heliyon ; 7(8): e07705, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34401586

RESUMO

Obesity is a widespread pathology among the population related to an increase in mortality and morbidity of patients. Bariatric surgery provides several forms of treatment for obese patients. Laparoscopic mini/one anastomosis gastric bypass (MGB/OAGB) is a recent low risk bariatric surgical procedure common in a large number of countries in the treatment of severe obesity. MGB/OAGB, compared to other bariatric surgery techniques, offers the significant technical improvement of requiring only one anastomosis in place of two. In this scenario, diagnostic imaging takes a significant role in the postoperative period, to evaluate the outcomes of surgical treatment and to detect possible complications both in early and late postoperative period. The prevalent radiological procedure to investigate suspicions of clinical post-operative complications is Computed tomography (CT) with oral and intravenous contrast administration. This pictorial essay aims to illustrate and identify normal radiological aspects of MGB/OAGB and post-surgery complication imaging features. We think that this article will serve to familiarize all the specialists with the diagnostic imaging of MGB/OAGB.

3.
Insights Imaging ; 12(1): 26, 2021 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33598763

RESUMO

OBJECTIVES: Changes in mechanical loading as well as pathology can modify the Achilles tendon mechanical properties and therefore detection of these changes is relevant for the diagnosis and management of Achilles tendinopathy. The aim of this study was to evaluate strain and shear wave sonoelastography for their ability to detect changes in the Achilles tendon mechanical properties during a series of isometric contractions. METHODS: Longitudinal sonoelastography images of the Achilles tendon were acquired from 20 healthy participants using four different ultrasound devices; two implementing strain sonoelastography technology (SE1, SE2) and two, shear wave elastography technology (SWE1, SWE2). RESULTS: SE1 measured a decreasing strain ratio (tendon become harder) during the different contraction levels from 1.51 (0.92) to 0.33 (0.16) whereas SE2 mesaured a decreasing strain ratio from 1.08 (0.76) to 0.50 (0.32). SWE1 measured decreasing tendon stiffness during contractions of increasing intensity from 33.40 (19.61) to 16.19 (2.68) whereas SWE2 revealed increasing tendon stiffness between the first two contraction levels from 428.65 (131.5) kPa to 487.9 (121.5) kPa followed by decreasing stiffness for the higher contraction levels from 459.35 (113.48) kPa to 293.5 (91.18) kPa. CONCLUSIONS: Strain elastography used with a reference material was able to detect elasticity changes between the different contraction levels whereas shear wave elastography was less able to detect changes in Achilles tendon stiffness when under load. Inconsistent results between the two technologies should be further investigated.

4.
Neuroradiology ; 63(7): 1053-1060, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33392736

RESUMO

PURPOSE: To assess early microstructural changes of meningiomas treated with proton therapy through quantitative analysis of intravoxel incoherent motion (IVIM) and diffusion-weighted imaging (DWI) parameters. METHODS: Seventeen subjects with meningiomas that were eligible for proton therapy treatment were retrospectively enrolled. Each subject underwent a magnetic resonance imaging (MRI) including DWI sequences and IVIM assessments at baseline, immediately before the 1st (t0), 10th (t10), 20th (t20), and 30th (t30) treatment fraction and at follow-up. Manual tumor contours were drawn on T2-weighted images by two expert neuroradiologists and then rigidly registered to DWI images. Median values of the apparent diffusion coefficient (ADC), true diffusion (D), pseudo-diffusion (D*), and perfusion fraction (f) were extracted at all timepoints. Statistical analysis was performed using the pairwise Wilcoxon test. RESULTS: Statistically significant differences from baseline to follow-up were found for ADC, D, and D* values, with a progressive increase in ADC and D in conjunction with a progressive decrease in D*. MRI during treatment showed statistically significant differences in D values between t0 and t20 (p = 0.03) and t0 and t30 (p = 0.02), and for ADC values between t0 and t20 (p = 0.04), t10 and t20 (p = 0.02), and t10 and t30 (p = 0.035). Subjects that showed a volume reduction greater than 15% of the baseline tumor size at follow-up showed early D changes, whereas ADC changes were not statistically significant. CONCLUSION: IVIM appears to be a useful tool for detecting early microstructural changes within meningiomas treated with proton therapy and may potentially be able to predict tumor response.


Assuntos
Neoplasias Meníngeas , Meningioma , Terapia com Prótons , Imagem de Difusão por Ressonância Magnética , Humanos , Neoplasias Meníngeas/diagnóstico por imagem , Neoplasias Meníngeas/radioterapia , Meningioma/diagnóstico por imagem , Meningioma/radioterapia , Movimento (Física) , Estudos Retrospectivos
5.
Eur J Radiol ; 133: 109345, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33120239

RESUMO

OBJECTIVE: This study evaluated the correlation between intratumoural stroma proportion, expressed as tumour-stroma ratio (TSR), and apparent diffusion coefficient (ADC) values in patients with rectal cancer. METHODS: This multicentre retrospective study included all consecutive patients with rectal cancer, diagnostically confirmed by biopsy and MRI. The training cohort (LUMC, Netherlands) included 33 patients and the validation cohort (VHIO, Spain) 69 patients. Two observers measured the mean and minimum ADCs based on single-slice and whole-volume segmentations. The TSR was determined on diagnostic haematoxylin & eosin stained slides of rectal tumour biopsies. The correlation between TSR and ADC was assessed by Spearman correlation (rs). RESULTS: The ADC values between stroma-low and stroma-high tumours were not significantly different. Intra-class correlation (ICC) demonstrated a good level of agreement for the ADC measurements, ranging from 0.84-0.86 for single slice and 0.86-0.90 for the whole-volume protocol. No correlation was observed between the TSR and ADC values, with ADCmeanrs= -0.162 (p= 0.38) and ADCminrs= 0.041 (p= 0.82) for the single-slice and rs= -0.108 (p= 0.55) and rs= 0.019 (p= 0.92) for the whole-volume measurements in the training cohort, respectively. Results from the validation cohort were consistent; ADCmeanrs= -0.022 (p= 0.86) and ADCminrs = 0.049 (p= 0.69) for the single-slice and rs= -0.064 (p= 0.59) and rs= -0.063 (p= 0.61) for the whole-volume measurements. CONCLUSIONS: Reproducibility of ADC values is good. Despite positive reports on the correlation between TSR and ADC values in other tumours, this could not be confirmed for rectal cancer.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias Retais , Humanos , Países Baixos , Neoplasias Retais/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Espanha
6.
Updates Surg ; 72(2): 493-502, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32189194

RESUMO

Laparoscopic mini/one anastomosis gastric bypass (MGB/OAGB) is an increasingly used bariatric surgical procedure. This surgical technique is effective in terms of both weight loss and the resolution of comorbidities, but it is not without complications. To report our experience in MGB/OAGB, assessing comorbidities and complications, and to illustrate post-surgical anatomy and radiological appearance of complications, a single-centre retrospective study of 953 patients undergoing MGB/OAGB between January 2005 and September 2018 was done. The inclusion criteria: body mass index (BMI) of 40 kg/m2 or higher or BMI between 35 and 40 kg/m2 with significant comorbidities not responsive to medical therapies. In the postoperative period, all patients were evaluated with clinical and laboratory tests and radiological examinations (upper gastrointestinal series, computed tomography and magnetic resonance imaging). Median weight was 126.69 kg and mean BMI was 49.4 kg/m2. Regarding comorbidities, 37.2%, 52.8%, 46.7% and 43.2% of patients presented with preoperatively diagnosed type 2 diabetes mellitus (T2DM), hypertensive disease, dyslipidaemia and obstructive sleep apnoea syndrome (OSAS), respectively. Median excess weight loss at 6, 12, 24 and 60 months after surgery was 33.45%, 53.81%, 68.75% and 68.80%, respectively. The remission of comorbidities was 91.4% for T2DM, 93.7% for hypertensive disease, 90.3% for dyslipidemia and 93.4% for OSAS. Early and late complication rates identified with radiological examinations were 1.5% and 1.6%, respectively. MGB/OAGB was effective for weight loss and comorbidities remission. Complications occurred at lower rate than with other surgical procedures were identified with imaging; CT was the main radiological technique.


Assuntos
Anastomose Cirúrgica/métodos , Derivação Gástrica/métodos , Laparoscopia/métodos , Obesidade/cirurgia , Adolescente , Adulto , Idoso , Comorbidade , Diabetes Mellitus Tipo 2/epidemiologia , Dislipidemias/epidemiologia , Feminino , Trato Gastrointestinal/diagnóstico por imagem , Humanos , Hipertensão/epidemiologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico por imagem , Obesidade/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
7.
Magn Reson Imaging ; 68: 158-166, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32057940

RESUMO

PURPOSE: To assess the ability and reproducibility of Non-contrast Magnetic Resonance Lymphography (NMRL) in detecting and quantify lymphedema, using a semiquantitative scoring system. METHODS AND MATERIAL: This is a monocentric retrospective study of 134 consecutive patients with a clinical diagnosis of limb lymphedema who performed a Non-contrast Magnetic Resonance Lymphography (NMRL) at our Institution between November 2014 and February 2017. Lymphedema was classified based both on clinical and radiologic evaluation. An NMRL total score was obtained for each limb's segment and compared to the clinical grade, used as reference standard. NMRL intra-observer, inter-observer variability and intraclass correlation were calculated. NMRL sensitivity, specificity, and accuracy in identifying lymphedema were provided. Based on score distribution an NMRL four-stage system was developed. RESULTS: NMRL showed 92% sensitivity, 77% specificity and 82% accuracy in identifying lymphedema. An almost perfect agreement was obtained by expert operators, while substantial agreement was obtained by non-expert operators. Substantial agreement resulted also for the inter-observer variability (Cohen's Kappa K = 0.73, CI 95% [0.69-0.78]). The intra-class correlation showed an almost perfect relationship both by expert and non-expert operators. Excellent correlation between clinical grade and NMRL score and between clinical grade and NMRL stage were found for each segment. CONCLUSIONS: NMRL is a confident and reproducible exam with high sensitivity, good specificity and high accuracy in lymphedema detection; the semiquantitative NMRL score resulted a reliable and reproducible tool able to quantify lymphedema severity.


Assuntos
Linfedema/diagnóstico por imagem , Linfografia/métodos , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
8.
Clin Transl Gastroenterol ; 10(10): e00081, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31609745

RESUMO

OBJECTIVES: The primary aim of this study was to investigate the value of attenuation imaging (ATI), a novel ultrasound technique for detection of steatosis, by comparing the results to that obtained with controlled attenuation parameter (CAP) and by using MRI-derived proton density fat fraction (PDFF) as reference standard. METHODS: From March to November 2018, 114 consecutive adult subjects potentially at risk of steatosis and 15 healthy controls were enrolled. Each subject underwent ATI and CAP assessment on the same day. MRI-PDFF was performed within a week. RESULTS: The prevalence of steatosis, as defined by MRI-PDFF ≥ 5%, was 70.7%. There was a high correlation of ATI with MRI-PDFF (r = 0.81, P < 0.0001). The correlation of CAP with MRI-PDFF and with ATI, respectively, was moderate (r = 0.65, P < 0.0001 and r = 0.61, P < 0.0001). The correlation of ATI or CAP with PDFF was not affected by age, gender, or body mass index. Area under the receiver operating characteristics of ATI and CAP, respectively, were 0.91 (0.84-0.95; P < 0.0001) and 0.85 (0.77-0.91; P < 0.0001) for detecting S > 0 steatosis (MRI-PDFF ≥ 5%); 0.95 (0.89-0.98; P < 0.0001) and 0.88 (0.81-0.93; P < 0.0001) for detecting S > 1 steatosis (MRI-PDFF ≥ 16.3%). The cutoffs of ATI and CAP, respectively, were 0.63 dB/cm/MHz and 258 dB/m for detecting S > 0 liver steatosis; 0.72 dB/cm/MHz and 304 dB/m for detecting S > 1 steatosis. ATI performed better than CAP, and this improvement was statistically significant for S > 1 (P = 0.04). DISCUSSION: This study shows that, in patients with no fibrosis/mild fibrosis, ATI is a very promising tool for the noninvasive assessment of steatosis.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Adulto , Idoso , Biópsia , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica , Projetos Piloto , Estudos Prospectivos , Prótons , Curva ROC , Ultrassonografia/métodos
10.
Radiol Case Rep ; 14(2): 141-145, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30405864

RESUMO

Eagle's syndrome (ES) refers to symptomatic elongation of the ossified styloid process. A styloid process greater than 2.5 cm in length should be considered abnormal; however, an elongated styloid process is not sufficient for a diagnosis of ES; only an abnormal styloid process in association with symptoms can confirm the syndrome. In this case report, we discuss a 54-year-old man who has come to our attention with various symptoms: dysphagia to both solids and liquids, difficulty swallowing, neck pain, and a foreign body sensation during bilateral neck rotation and mouth opening. The diagnosis is performed radiologically because conventional radiographs have many potential disadvantages, whereas, computed tomography (CT) scans and reconstructions allow the length and angulation of the styloid process to be measured and the relationship between the elongated styloid processes and adjacent anatomical structures to be evaluated. Moreover, CT allows for differential diagnosis and provides detailed information needed for surgical planning.

11.
Neuromuscul Disord ; 28(6): 476-483, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29661643

RESUMO

The aim of this study was to determine muscle tissue elasticity, measured with shear-wave elastography, in selected lower limb muscles of patients affected by Duchenne muscular dystrophy (DMD) and to correlate the values obtained with those recorded in healthy children and with muscle magnetic resonance imaging (MRI) data from the same DMD children, specifically the pattern on T1-weighted (w) and short-tau inversion recovery (STIR) sequences. Five preschool DMD children and five age-matched healthy children were studied with shear-wave elastography. In the DMD children, muscle stiffness was moderately higher compared with the muscle stiffness in HC, in the rectus femoris, vastus lateralis, adductor magnus and gluteus maximus muscles. On muscle MRI T1-w images showed fatty replacement in 3/5 patients at the level of the GM, while thigh and leg muscles were affected in 2/5; hyperintensity on STIR images was identified in 4/5 patients. No significant correlation was observed between stiffness values and MRI scoring. Our study demonstrated that lower limb muscles of preschool DMD patients show fatty replacement and patchy edema on muscle MRI and increased stiffness on shear-wave elastography. In conclusion, although further studies in larger cohorts are needed, shear-wave elastography could be considered a useful non-invasive tool to easily monitor muscle changes in early stages of the disease.


Assuntos
Músculo Esquelético/diagnóstico por imagem , Distrofia Muscular de Duchenne/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Estudos de Casos e Controles , Pré-Escolar , Técnicas de Imagem por Elasticidade/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Índice de Gravidade de Doença , Coxa da Perna/diagnóstico por imagem
12.
J Ultrasound Med ; 37(9): 2263-2275, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29574932

RESUMO

OBJECTIVES: To evaluate the carotid bifurcation in healthy adults using a commercial system equipped with high-frame rate vector flow imaging (VFI) based on the plane wave and to compare VFI with color Doppler imaging. METHODS: Carotid bifurcation diameters and flow characteristics of 60 vessels in 60 healthy volunteers were evaluated quantitatively and qualitatively to assess complex flow patterns and their extension and duration. RESULTS: Complex flow in the internal carotid artery (ICA) was associated with a statistically significant difference in the ΔICA sinus-to-common carotid artery (CCA) diameter ratio (the relative change in diameter between the CCA and ICA sinus.) Vector flow imaging and color Doppler imaging were in accordance when detecting complex flow in 96.7% of cases; in 3.3% of cases, only VFI identified small recirculation areas of short duration. Vector flow imaging highlighted a larger extension of the complex flow (mean ± SD, 47.7 ± 28.5 mm2 ; median, 45.5 mm2 ) compared with color Doppler imaging (mean, 29.2 ± 19.9 mm2 ; median, 29.5 mm2 ) and better depicted different complex flow patterns; a strong correlation (r = 0.84) was found between the ΔICA sinus-to-CCA diameter ratio and the complex flow extension. Vector flow imaging showed a longer duration of the flow disturbances (mean, 380 ± 218 milliseconds; median, 352.5 milliseconds) compared with color Doppler imaging (mean, 325 ± 206 milliseconds; median, 333 milliseconds), and there was a strong correlation (r = 0.92). CONCLUSIONS: Vector flow imaging is as effective as color Doppler imaging in the detection of flow disturbances, but it is more powerful in the assessment of complex flow patterns.


Assuntos
Artéria Carótida Primitiva/fisiologia , Artéria Carótida Interna/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Ultrassonografia Doppler em Cores/métodos , Adulto Jovem
13.
J Ultrasound ; 20(4): 293-299, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29204233

RESUMO

PURPOSE: Peripheral nerves frequently travel close to the bone surface and are, therefore, prone to elastosonographic "bone-proximity" hardening artifacts. The impact of these artifacts on quantitative measurements of median nerve stiffness performed by shear wave elastosonography has not been explored. Our aim was to assess normal median nerve stiffness values at various locations. MATERIALS AND METHODS: Thirty-six healthy volunteers (24 women and 12 men) aged between 25 and 40 years were evaluated. Two operators performed the evaluation: one expert (6 years of ultrasound experience) and one inexperienced operator (6 months' experience). The nerve was sampled in cross-section at three different locations: mid-forearm, immediately before the carpal tunnel and within the tunnel. The ultrasound scanner was equipped with a 14-MHz linear probe. The Shear Wave module was activated in one-shot mode. Measurements were performed using a ROI corresponding to the diameter of the nerve. RESULTS: The mean values of stiffness of the medial nerve were 32.26 kPa ± 18.60 within the carpal tunnel, 22.20 kPa ± 9.84 at the carpal tunnel inlet and 7.62 kPa ± 7.38 in the forearm. Inter-observer agreement assessed using the intraclass correlation coefficient (ICC) was "moderate" within the carpal tunnel (ICC = 0.44), "moderate" at the carpal tunnel inlet (ICC = 0.41) and "fair" in the forearm (ICC = 0.38). CONCLUSIONS: The stiffness of the median nerve progressively increases in its distal portions, where the nerve approaches the bone surface. Inter-observer agreement was generally good (from fair to moderate).


Assuntos
Técnicas de Imagem por Elasticidade , Nervo Mediano/diagnóstico por imagem , Adulto , Artefatos , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/fisiologia , Elasticidade , Feminino , Humanos , Masculino , Nervo Mediano/anatomia & histologia , Nervo Mediano/fisiologia , Variações Dependentes do Observador , Tamanho do Órgão , Competência Profissional
14.
J Clin Ultrasound ; 45(9): 582-588, 2017 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-28734035

RESUMO

Doppler ultrasonography is routinely used to identify abnormal blood flow. Nevertheless, conventional Doppler can be used to determine only the axial component of blood flow velocity and is angle dependent. A new method of multidimensional angle-independent estimation of flow velocity, called Vector Flow Imaging (VFI), has been proposed. It quantitatively evaluates the true velocity vector's amplitude and direction at any location into a vessel and displays a more intuitive depiction of the flow movements. High frame rate VFI, based on plane wave imaging, allows a detailed dynamic visualization of complex flow by showing even transient events, otherwise undetectable. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:582-588, 2017.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Vasos Sanguíneos/fisiologia , Humanos
15.
J Vasc Access ; 18(4): 284-289, 2017 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-28574142

RESUMO

INTRODUCTION: We report the use of a new ultrasound technique to evaluate the axial and lateral components of a complex flow in the arteriovenous fistula (AVF). Vector Flow Imaging (VFI) allows to identify different components of the flow in every direction, even orthogonal to the flow streamline, represented by many single vectors. VFI could help to identify flow alterations in AVF, probably responsible for its malfunction. METHODS: From February to June 2016, 14 consecutive patients with upper-limb AVF were examined with a Resona 7 (Mindray, Shenzhen, China) ultrasound scanner equipped with VFI. An analysis of mean velocity, angular direction and mean number of vectors impacting the vessel wall was carried out. We also identified main flow patterns present in the arterial side, into the venous aneurysm and in correspondence of significant stenosis. RESULTS: A disturbed flow with the presence of vectors directed against the vessel walls was found in 9/14 patients (64.28%): in correspondence of the iuxta-anastomotic venous side (4/9; 44.4%), into the venous aneurysmal tracts (3/9; 33.3%) and in concomitance of stenosis (2/9; 22.2%). The mean velocity of the vectors was around 20-25 cm/s, except in presence of stenosis, where the velocities were much higher (45-50 cm/s). The vectors directed against the vessel walls presented high angle attack (from 45° to 90°, with a median angular deviation 65°). CONCLUSIONS: VFI was confirmed to be an innovative and intuitive imaging technology to study the flow complexity in the arteriovenous fistulas.


Assuntos
Derivação Arteriovenosa Cirúrgica , Imagem de Perfusão/métodos , Diálise Renal , Ultrassonografia Doppler em Cores , Extremidade Superior/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Velocidade do Fluxo Sanguíneo , Constrição Patológica , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
16.
Insights Imaging ; 8(3): 319-328, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28500487

RESUMO

Carotid artery atherosclerotic disease is still a significant cause of cerebrovascular morbidity and mortality. A new angle-independent technique, measuring and visualizing blood flow velocities in all directions, called vector flow imaging (VFI) is becoming available from several vendors. VFI can provide more intuitive and quantitative imaging of vortex formation, which is not clearly distinguishable in the color Doppler image. VFI, as quantitative method assessing disturbed flow patterns of the carotid bifurcation, has the potential to allow better understanding of the diagnostic value of complex flow and to enhance risk stratification. This pictorial review article will show which new information VFI adds for the knowledge of hemodynamics in comparison to the conventional ultrasound techniques. TEACHING POINTS: • VFI is an angle-independent technique measuring flow velocities in all directions. • This kind of VFI is based on a plane wave multidirectional excitation technique. • VFI allows quantitative assessment of carotid streamlines progression and visualizes vorticity. • VFI does not allow a precise comprehension of streamlines' 3D shape. • VFI allows a better understanding of carotid artery complex flows.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA