Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Sci Rep ; 10(1): 13795, 2020 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-32782328

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

2.
Sci Rep ; 9(1): 17652, 2019 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-31776364

RESUMO

Intraoperative radiography imaging is essential for accurate spinal implant placement. Hazards caused by ionizing radiation raised concern on personnel's work life long exposure in the operating room (OR). To particularize a cumulative risk estimation of radiation of personnel and patient, depending on used methods (C-arm fluoroscopy, O-arm navigation) and patient characteristics during spinal surgery, detailed investigation of radiation exposure in a clinical setting is required. Lumbosacral dorsal spinal fusion was performed in 37 patients (19 navigated, 18 fluoroscopy) during this prospective study. Radiation exposure was measured on several body regions with thermoluminescent dosimeters on patient and OR personnel (surgeon, assistant, sterile nurse, radiology technologist). Comparison between patient characteristics and radiation exposure was included. The highest patients values were measured in the surgery field and gonads area during navigation (43.2 ± 19.4 mSv; fluoroscopy: 27.7 ± 31.3 mSv; p = 0.02), followed by the thoracic region during fluoroscopy (7.7 ± 14.8 mSv; navigation: 1.1 ± 1.0 mSv; p = 0.06), other measured regions can be considered marginal in comparison. Amongst OR personnel exposure of the surgeon was significant higher during fluoroscopy (right hand: 566 ± 560 µSv and thoracic region: 275 ± 147 µSv; followed by thyroid and forehead) compared to navigation (right finger: 49 ± 19 µSv; similar levels for all regions; p < 0.001 in all regions). When compared to the surgeon, other OR personnel had significantly lower radiation doses on all body regions using fluoroscopy, and similar dose during navigation. The highest eye's lens region value was measured during fluoroscopy for the patient (185 ± 165 µSv; navigation: 205 ± 60 µSv; p = 0.57) and the surgeon (164 ± 74 µSv; navigation: 92 ± 41 µSv; p < 0.001). There was a significant correlation between patient BMI and radiation exposure to the surgery field during fluoroscopy. To our knowledge, these data present the first real life, detailed comparison of radiation exposure on OR personnel and patients between clinical use of navigation and fluoroscopy. Although patient's radiation dose is approximately 3-fold during navigation compared to the fluoroscopy, we found that a spinal surgeon could perform up to 10-fold number of surgeries (10.000 versus 883) until maximum permissible annual effective radiation dose would be reached. Especially for a spinal surgeon, who is mainly exposed amongst OR personnel, radiation prevention and protection must remain a main issue.


Assuntos
Fluoroscopia/efeitos adversos , Período Intraoperatório , Salas Cirúrgicas/normas , Exposição à Radiação/normas , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/efeitos adversos , Humanos , Exposição Ocupacional/normas , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação/análise , Cirurgiões
3.
Arch Orthop Trauma Surg ; 139(12): 1699-1704, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31127409

RESUMO

PURPOSE: Accurate placement of spinal pedicle screws (PS) is mandatory for good primary segmental stabilization allowing consequent osseous fusion, requiring judgmental experience developed during a long training process. Computer navigation offers permanent visual control during screw manipulation and has been shown to significantly lower the risk of pedicle perforation. This study aims to evaluate whether safety, accuracy, and judgmental skills in screw placement, comparable to an experienced surgeon, can be developed during training using computer navigation. METHODS: Lumbosacral PS were placed in 18 patients in a prospective setting, in one segment side with conventional fluoroscopy by a senior spine-surgeon, and computer navigated on the other side by a trainee without prior experience in the technique. At the beginning and at the end of the study, PS were placed freehand in solid foam models by the trainee. PS placement time, intraoperative placement revisions, PS placement accuracy on postoperative CT scans, and postoperative complications were assessed. RESULTS: Significant improvement of trainee's PS placement accuracy (Sclafani score 8.2-8.83; p = 0.006) and time (13.3-6.8 min per screw; p = 0.005) to a similar level as the experienced surgeon state (5.2-4.1 min per screw; p = 0.39) was explored; similar improvement was explored in the foam models. The number of intraoperative placement revisions kept on a low level for surgeon (3.3-0.0%) and trainee (5.1-2.6%) during the whole study, no postoperative complications occurred. CONCLUSION: Navigated PS insertion allows safe teaching from the early beginning of surgical training, due to steady intraoperative control on PS placement. Adequacy of PS placement is similar to screws placed by an experienced surgeon. Progress in judgmental skills in screw placement can be gained rapidly by the trainee, which can also be transferred to non-computer navigated PS placement.


Assuntos
Vértebras Lombares/cirurgia , Parafusos Pediculares , Radiografia Intervencionista/métodos , Fusão Vertebral/educação , Adulto , Competência Clínica/normas , Estudos de Viabilidade , Feminino , Fluoroscopia/métodos , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X/métodos
4.
Sci Rep ; 8(1): 8802, 2018 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-29892047

RESUMO

The early and accurate diagnosis of periprosthetic joint infection (PJI) can be challenging. Fibrinogen plays an important role in mediating inflammation of bacterial infections and therefore could be a valuable biomarker for PJI. The purpose of this study was to investigate the sensitivity and specificity of serum levels of fibrinogen in detecting PJI, and to compare the results with the established PJI biomarkers C-reactive protein (CRP) and leukocyte count. Eighty-four patients (124 surgeries) were prospectively included. The preoperatively analyzed parameters were fibrinogen, CRP and leukocyte count. The sensitivity and specificity of the biomarkers were calculated and compared. Fibrinogen (p < 0.001), CRP (p < 0.001) and leukocyte count (p < 0.001) had a statistically significant correlation with the criteria defining the presence of PJI. For fibrinogen, the value of 519 mg/dl had a sensitivity of 0.90 and a specificity of 0.34. The CRP cut-off point of 11.00 mg/dl had a sensitivity of 0.90 and a specificity of 0.74. The leukocyte count of 5.68 G/l had a sensitivity of 0.90 and a specificity of 0.39. Our results indicated that fibrinogen is a significant biomarker for detecting a bacterial PJI. It has shown to be a cost-efficient diagnostic support with high sensitivity and specificity.


Assuntos
Biomarcadores/sangue , Testes Diagnósticos de Rotina/métodos , Fibrinogênio/análise , Osteoartrite/diagnóstico , Osteoartrite/patologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/patologia , Idoso , Idoso de 80 Anos ou mais , Proteína C-Reativa/análise , Custos e Análise de Custo , Testes Diagnósticos de Rotina/economia , Humanos , Contagem de Leucócitos , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Soro/química
5.
Case Rep Med ; 2017: 2923696, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28194180

RESUMO

Purpose. Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods. We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results. A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI) tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion. Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

6.
Orthopade ; 42(9): 785-92; quiz 793-4, 2013 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-23989596

RESUMO

Chronic neck pain is often associated with spondylarthrosis, whereby segments C4/C5 (C: cervical) are most frequently affected. Spondylarthrosis can be the sole complaint, but it is associated with a degenerative cascade of the spine. The umbrella term for neck pain is the so-called cervical syndrome, which can be differentiated into segmental dysfunction and/or morphological changes of the intervertebral discs and small joints of the vertebral column. Conservative therapy modalities include physical therapy, subcutaneous application of local anesthetics, muscle, nerve and facet joint injections in addition to adequate analgesic and muscle relaxant therapy. If surgery is required, various techniques via dorsal and ventral approaches, depending on the clinic and morphologic changes, can be applied.


Assuntos
Vértebras Cervicais/cirurgia , Laminectomia/métodos , Cervicalgia/etiologia , Cervicalgia/terapia , Bloqueio Nervoso/métodos , Espondilartrite/complicações , Espondilartrite/terapia , Vértebras Cervicais/patologia , Terapia Combinada , Humanos , Cervicalgia/diagnóstico , Espondilartrite/diagnóstico
7.
Orthopade ; 42(3): 177-86, 2013 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-23493996

RESUMO

CLINICAL/METHODICAL ISSUE: Imaging for shoulder surgery varies a lot nowadays. Advantages and disadvantages of possible imaging methods according to the pathology and treatment options are described. STANDARD RADIOLOGICAL METHODS: Digital projection radiography in 3 planes, ultrasonography, MRI, CT scanning and scintigrams. METHODICAL INNOVATIONS: Special axial view to visualize the glenoid situation, as well as 3-D CT scanning for larger defects and classification. PERFORMANCE: Imaging of the glenoid situation, the version and erosion in axial view x-ray is mandatory to plan and control glenoid replacement. ACHIEVEMENTS: Useful application of imaging methods for the daily routine of orthopedic surgeons. PRACTICAL RECOMMENDATIONS: Digital 3 plane x-ray imaging in arthroplasty surgery is the minimum requirement. For rotator cuff lesions ultrasonography is good. In order to gain information on fatty infiltration of rotator muscles MRI is needed as well as for intra-articular lesions. For bony defects CT and reconstruction 3-D are recommended.


Assuntos
Aumento da Imagem/métodos , Osteoartrite/diagnóstico , Osteoartrite/cirurgia , Articulação do Ombro/patologia , Articulação do Ombro/cirurgia , Cirurgia Assistida por Computador/métodos , Humanos , Radiografia , Articulação do Ombro/diagnóstico por imagem
8.
Knee Surg Sports Traumatol Arthrosc ; 21(10): 2234-40, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23114870

RESUMO

PURPOSE: Recently, new custom-fit pin guides in total knee arthroplasty (TKA) have been introduced. Use of these guides may reduce operating time. Use of the guides combined with the absence of intramedullary alignment jigs may lead to reduced blood loss and improved early outcomes. Our aim was to evaluate blood loss and early clinical outcomes in patients undergoing minimally invasive TKA using custom-fit magnetic resonance imaging (MRI)-based pin guides. METHODS: A prospective study in 80 patients was carried out. Patients were divided randomly into 2 equal groups. In one group, intramedullary alignment jigs were used. In the second group, custom-fit MRI-based pin guides were used. All patients received the same cemented posterior-stabilized implant through a mini-midvastus approach. The volume in the drain bottles was recorded after 48 h. Hb loss was estimated by subtracting the postoperative from the preoperative Hb level. Transfusion requirements and surgical time were recorded. Outcome measures were Knee Society Scores (KSS), knee flexion, knee swelling and pain. RESULTS: There was lower mean drainage of blood in the custom-fit group (391 ml vs. 603 ml; p < 0.0001). There was no difference in estimated loss of Hb (3.6 g/dl vs. 4.1 g/dl; n.s.) and in transfusion requirements (7.5 % vs. 10 %; n.s.). Surgical time was reduced in the custom-fit group (12 min less; p = 0.001). KSS measured at week 2, 6 and 12 showed no significant difference between groups. Knee flexion measured on days 7, 10 and at week 6, 12 and knee swelling and pain measured on days 1, 3, 10 and at week 6, 12 showed no significant difference between groups. CONCLUSIONS: Using custom-fit pin guides reduces blood drainage, but not the estimated Hb loss in minimally invasive TKA and does not affect transfusion rate. Surgical time is reduced. There is no effect on the early clinical outcomes. LEVEL OF EVIDENCE: Therapeutic study, Level I.


Assuntos
Artroplastia do Joelho/métodos , Perda Sanguínea Cirúrgica/prevenção & controle , Imageamento por Ressonância Magnética , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Osteoartrite do Joelho/cirurgia , Cuidados Pré-Operatórios/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/instrumentação , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Transfusão de Sangue/estatística & dados numéricos , Pinos Ortopédicos , Feminino , Humanos , Imageamento Tridimensional , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Modelos Anatômicos , Duração da Cirurgia , Estudos Prospectivos , Cirurgia Assistida por Computador/instrumentação , Resultado do Tratamento
9.
Orthopade ; 41(4): 313-24; quiz 325-6, 2012 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-22476423

RESUMO

The clinical finding of flatfoot is characterized by a flattening of the medial longitudinal arch and valgus deformity of the hindfoot. The differential diagnosis of flatfoot is the physiological, flexible, contracted flatfoot, which occurs as a congenital or acquired deformity. Congenital flatfoot deformity requires early intensive therapy, while a flexible flatfoot in children has a good prognosis and conservative treatment usually leads to a stable and sufficient load-bearing foot. Severe flatfoot in children can be corrected successfully by simple, minimally invasive procedures. In adults with symptomatic flatfoot, which usually occurs due to an insufficiency of the tendon of the tibialis posterior, conservative therapy with insoles, shoe modifications and physiotherapeutic measures can lead to significant improvement, otherwise surgical correction is recommended. Early, stage-appropriate therapy helps to prevent an impending decompensation of the hindfoot.


Assuntos
Terapia por Exercício/métodos , Pé Chato/diagnóstico , Pé Chato/terapia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Aparelhos Ortopédicos , Procedimentos de Cirurgia Plástica/métodos , Sapatos , Adulto , Criança , Humanos
10.
Orthopade ; 40(5): 449-62, 2011 May.
Artigo em Alemão | MEDLINE | ID: mdl-21448681

RESUMO

Scoliosis, a permanent abnormal curvature of the spine to the side, is divided into four forms: idiopathic (infantile, juvenile and adolescent, accounting for 80% of cases), neurogenic, congenital and adult scoliosis. Most patients with adolescent idiopathic scoliosis initially have mainly cosmetic problems. However, neurogenic, congenital and adult scoliosis can lead to severe clinical symptoms. The leading symptom is back pain caused by secondary changes. In recent years the Lenke classification has been proven to be a reliable tool for disease classification. Non-progressive scoliosis is usually treated conservatively. In the case of Cobb angles of greater than 50°, surgical therapy is recommended in patients presenting before adulthood. Technical improvements in implants and the optimisation of surgical methods have set a trend in the direction of surgical therapy.


Assuntos
Dor nas Costas/etiologia , Dor nas Costas/prevenção & controle , Procedimentos de Cirurgia Plástica/métodos , Escoliose/diagnóstico , Escoliose/cirurgia , Adolescente , Adulto , Dor nas Costas/diagnóstico , Criança , Pré-Escolar , Humanos , Lactente , Escoliose/complicações
11.
J Clin Pathol ; 58(11): 1152-6, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16254103

RESUMO

BACKGROUND/AIMS: Although the standard treatment for desmoid tumours is complete surgical resection with wide margins, the optimal adjuvant treatment for recurrent or inoperable disease is unclear, often being based on sporadic immunohistochemical reports with a low number of cases. Therefore, a large immunohistochemical study was performed, to provide a theoretical basis for adjuvant treatment regimens. METHODS: One hundred and sixteen tissue samples from 80 patients (49 female, 31 male; mean age, 34 years; range, 0-83) with desmoid tumours (46 extra-abdominal, 21 abdominal, 13 intra-abdominal) were tested for oestrogen receptors alpha and beta, progesterone and androgen receptors, and somatostatin, in addition to HER2, cathepsin D, Ki-67, and c-KIT by immunohistochemistry. RESULTS: All samples were negative for oestrogen receptor alpha, HER2, and the progesterone receptor. Positive staining for the androgen receptor was found in six extra-abdominal cases. Staining for oestrogen receptor beta was positive in four extra-abdominal, two abdominal, and one intra-abdominal case. Staining for somatostatin was positive in six extra-abdominal, two abdominal, and one intra-abdominal case, and staining for cathepsin D was positive in all cases. Positive staining for Ki-67 was found in 14 extra-abdominal, three abdominal, and three intra-abdominal cases. C-KIT was detectable in one abdominal case only. CONCLUSIONS: The data from this immunohistochemical study show that the published effects of antioestrogens and imatinib mesylate in the treatment of aggressive fibromatoses may not be attributable to oestrogen receptor alpha or c-KIT expression.


Assuntos
Biomarcadores Tumorais/análise , Fibromatose Agressiva/metabolismo , Neoplasias de Tecidos Moles/química , Neoplasias Abdominais/química , Neoplasias Abdominais/tratamento farmacológico , Neoplasias Abdominais/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Catepsina D/análise , Quimioterapia Adjuvante , Criança , Pré-Escolar , Feminino , Fibromatose Agressiva/tratamento farmacológico , Fibromatose Agressiva/patologia , Humanos , Lactente , Recém-Nascido , Antígeno Ki-67/análise , Masculino , Pessoa de Meia-Idade , Proteínas de Neoplasias/análise , Proteínas Proto-Oncogênicas c-kit/análise , Receptores Androgênicos/análise , Receptores de Estrogênio/análise , Receptores de Progesterona/análise , Neoplasias de Tecidos Moles/tratamento farmacológico , Neoplasias de Tecidos Moles/patologia , Somatostatina/análise
13.
Orthopade ; 32(4): 287-91, 2003 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-12707691

RESUMO

Clinical scores and fluoroscopically guided standard X-rays are still the golden standard for evaluating the outcome of total knee arthroplasty, but up to now there was no way to evaluate the function of mobile inlays except with digital fluoroscopy. We describe a new method using a flat 8-MHz ultrasound for the in vivo measurement of meniscal bearings (MB) with an accuracy and precision of 0.7 mm and 0.4 mm, respectively. In 73 knees with LCS classic total knee replacement, all of the medial (100%) and 71 of the lateral (97%) MB could be analyzed. The MB moved unhindered with an average total shift of 4.5 mm (range: 0.2-12.1) on the medial and 4.2 mm (range: 0.8-13.2) on the lateral side. A significant correlation was found between the active range of motion (ROM) of the knee joint and the medial MB's shift ( p=0.004) but not for the lateral MB ( p=0.114). Three knees had to be revised due to aseptic loosening (2) or excessive PE wear (1). No single parameter of the ultrasound analysis could be detected to be predictive for the MB's failure. Conventional ultrasound allows the analysis of MB function at low cost with an accuracy better than 1 mm. This method is an alternative to radiological methods and suitable for studies with larger numbers of patients followed over longer periods.


Assuntos
Artrite Reumatoide/cirurgia , Prótese do Joelho , Meniscos Tibiais/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Amplitude de Movimento Articular/fisiologia , Análise de Falha de Equipamento/estatística & dados numéricos , Fluoroscopia , Seguimentos , Humanos , Prótese do Joelho/estatística & dados numéricos , Computação Matemática , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem , Ultrassonografia
14.
J Bone Joint Surg Br ; 82(8): 1151-5, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11132277

RESUMO

We performed a retrospective analysis of the clinical and radiological outcomes of total hip replacement using an uncemented femoral component proximally coated with hydroxyapatite. Of 136 patients, 118 who had undergone 124 primary total hip replacements were available for study. Their mean age was 66.5 years (19 to 90) and the mean follow-up was 5.6 years (4.25 to 7.25). At the final follow-up the mean Harris hip score was 92 (47.7 to 100). Periprosthetic femoral fractures, which occurred in seven patients (5.6%), were treated by osteosynthesis in six and conservatively in one. We had to revise five femoral components, one because of aseptic loosening, one because of septic loosening and three because of periprosthetic fracture. At the final follow-up there were definite signs of aseptic loosening in two patients. Radiologically, proximal femoral bone loss in Gruen zones I and VI was evident in 96.8% of hips, while bone hypertrophy in zones III and V was seen in 64.7%. In 24 hips (20.2%) the mean subsidence of the stem was 3.7 mm which occurred within the first 12 postoperative weeks. This indicated poor initial stability, which might have been aggravated by early weight-bearing. The high rate of failure in our study suggests that proximal femoral bone loss affects the long-term survival of the replacement.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Materiais Biocompatíveis/uso terapêutico , Materiais Revestidos Biocompatíveis/uso terapêutico , Durapatita/uso terapêutico , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/etiologia , Hiperostose/diagnóstico por imagem , Hiperostose/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Deambulação Precoce/efeitos adversos , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Modelos de Riscos Proporcionais , Desenho de Prótese , Falha de Prótese , Radiografia , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA