Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Phys Eng Sci Med ; 46(3): 1015-1021, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37219797

RESUMO

Radiotherapy treatment planning based only on magnetic resonance imaging (MRI) has become clinically achievable. Though computed tomography (CT) is the gold standard for radiotherapy imaging, directly providing the electron density values needed for planning calculations, MRI has superior soft tissue visualisation to guide treatment planning decisions and optimisation. MRI-only planning removes the need for the CT scan, but requires generation of a substitute/synthetic/pseudo CT (sCT) for electron density information. Shortening the MRI imaging time would improve patient comfort and reduce the likelihood of motion artefacts. A volunteer study was previously carried out to investigate and optimise faster MRI sequences for a hybrid atlas-voxel conversion to sCT for prostate treatment planning. The aim of this follow-on study was to clinically validate the performance of the new optimised sequence for sCT generation in a treated MRI-only prostate patient cohort. 10 patients undergoing MRI-only treatment were scanned on a Siemens Skyra 3T MRI as part of the MRI-only sub-study of the NINJA clinical trial (ACTRN12618001806257). Two sequences were used, the standard 3D T2-weighted SPACE sequence used for sCT conversion which has been previously validated against CT, and a modified fast SPACE sequence, selected based on the volunteer study. Both were used to generate sCT scans. These were then compared to evaluate the fast sequence conversion for anatomical and dosimetric accuracy against the clinically approved treatment plans. The average Mean Absolute Error (MAE) for the body was 14.98 ± 2.35 HU, and for bone was 40.77 ± 5.51 HU. The external volume contour comparison produced a Dice Similarity Coefficient (DSC) of at least 0.976, and an average of 0.985 ± 0.004, and the bony anatomy contour comparison a DSC of at least 0.907, and an average of 0.950 ± 0.018. The fast SPACE sCT agreed with the gold standard sCT within an isocentre dose of -0.28% ± 0.16% and an average gamma pass rate of 99.66% ± 0.41% for a 1%/1 mm gamma tolerance. In this clinical validation study, the fast sequence, which reduced the required imaging time by approximately a factor of 4, produced an sCT with similar clinical dosimetric results compared to the standard sCT, demonstrating its potential for clinical use for treatment planning.


Assuntos
Próstata , Planejamento da Radioterapia Assistida por Computador , Humanos , Masculino , Imageamento por Ressonância Magnética/métodos , Pelve , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
2.
J Med Radiat Sci ; 70 Suppl 2: 107-113, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36604384

RESUMO

Magnetic Resonance Imaging (MRI) has proven value in radiotherapy treatment planning (RTP). MRI provides excellent soft tissue contrast, and improves lesion detection, definition and extent, allowing for increased conformal treatment. Recent installation of dedicated MRI simulators and MRI-guided linear accelerators (MR Linacs) within radiation oncology departments has led to a sudden and rapid expansion in the scope of practice for many radiation therapists and MRI radiographers. The lack of current recommendations, guidelines and credentialing for both MRI radiographers and radiation therapists working within these atypical MRI environments poses a significant challenge for the education and training of staff, and the safe operation of these units. This commentary discusses current pathways for radiographers and radiation therapists entering the emerging field of MRI-guided radiation oncology, and the future role of the MRI radiographer in addressing the unique issues found in non-standard MRI environments. The authors draw on their collective experience as MRI radiographers assisting the rollout of dedicated MRI simulators in radiation oncology departments across Australia and reflect on the need for close collaboration between radiographers, radiation therapists and their respective departments. There is also a critical role for professional bodies to play in supporting existing and future roles in MRI and recognising advanced practitioner scope of practice.


Assuntos
Radioterapia (Especialidade) , Radioterapia Guiada por Imagem , Humanos , Austrália , Imageamento por Ressonância Magnética
3.
J Med Imaging (Bellingham) ; 9(4): 044005, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35992729

RESUMO

Purpose: Radiomics of magnetic resonance images (MRIs) in rectal cancer can non-invasively characterize tumor heterogeneity with potential to discover new imaging biomarkers. However, for radiomics to be reliable, the imaging features measured must be stable and reproducible. The aim of this study is to quantify the repeatability and reproducibility of MRI-based radiomic features in rectal cancer. Approach: An MRI radiomics phantom was used to measure the longitudinal repeatability of radiomic features and the impact of post-processing changes related to image resolution and noise. Repeatability measurements in rectal cancers were also quantified in a cohort of 10 patients with test-retest imaging among two observers. Results: We found that many radiomic features, particularly from texture classes, were highly sensitive to changes in image resolution and noise. About 49% of features had coefficient of variations ≤ 10 % in longitudinal phantom measurements. About 75% of radiomic features in in vivo test-retest measurements had an intraclass correlation coefficient of ≥ 0.8 . We saw excellent interobserver agreement with mean Dice similarity coefficient of 0.95 ± 0.04 for test and retest scans. Conclusions: The results of this study show that even when using a consistent imaging protocol many radiomic features were unstable. Therefore, caution must be taken when selecting features for potential imaging biomarkers.

4.
J Med Imaging Radiat Oncol ; 66(5): 717-723, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35687525

RESUMO

Magnetic resonance imaging (MRI) is increasingly being integrated into the radiation oncology workflow, due to its improved soft tissue contrast without additional exposure to ionising radiation. A review of MRI utilisation according to evidence based departmental guidelines was performed. Guideline utilisation rates were calculated to be 50% (true utilisation rate was 46%) of all new cancer patients treated with adjuvant or curative intent, excluding simple skin and breast cancer patients. Guideline utilisation rates were highest in the lower gastrointestinal and gynaecological subsites, with the lowest being in the upper gastrointestinal and thorax subsites. Head and neck (38% vs 45%) and CNS (46% vs 67%) cancers had the largest discrepancy between true and guideline utilisation rates due to unnamed reasons and non-contemporaneous diagnostic imaging respectively. This report outlines approximate MRI utilisation rates in a tertiary radiation oncology service and may help guide planning for future departments contemplating installation of an MRI simulator.


Assuntos
Neoplasias da Mama , Radioterapia (Especialidade) , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Radioterapia (Especialidade)/métodos
5.
Med Phys ; 49(7): 4508-4517, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35365884

RESUMO

PURPOSE: To assess the technical performance of the apparent diffusion coefficient (ADC) on a dedicated 3T radiotherapy scanner, using a standardized phantom and sequences. Investigations into factors that could impact the technical performance of ADC in the clinic were also completed, including changing the slice-encoded imaging direction and the reference sample ADC value. METHODS: ADC acquisitions were performed monthly on an isotropic diffusion phantom over 1 year. Measurements of ADC %bias, coefficients of variation for short-/long-term repeatability and precision (CVST /CVLT and CVP ), and b-value dependency (Depb ) were calculated. The measurements were then assessed according to the Quantitative Imaging Biomarker Alliance (QIBA) Diffusion Profile specifications. RESULTS: The average of all measurements over the year was within Profile recommended ranges. This included when testing was performed in different imaging directions, and on samples that had different ADC reference values (0.4-1.1 µm2 /ms). Results in the axial plane for the central water vial included a bias of +0.05%, CVST /CVLT /CVP  = 0.1%/ 0.9%/0.4% and Depb  = 0.4%. CONCLUSIONS: The technical performance of ADC on a radiotherapy dedicated MRI scanner over the course of 12 months was considered conformant to the QIBA Profile. Quantifying these metrics and factors that may affect the performance is essential in progressing the use of ADC clinically: ensuring that the observed change of ADC in a tissue is due to a physiological response and not measurement variability.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Biomarcadores , Imagem de Difusão por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
6.
J Appl Clin Med Phys ; 22(11): 143-150, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34562341

RESUMO

PURPOSE: To determine baseline accuracy and reproducibility of T1 and T2 relaxation times over 12 months on a dedicated radiotherapy MRI scanner. METHODS: An International Society of Magnetic Resonance in Medicine/National Institute of Standards and Technology (ISMRM/NIST) System Phantom was scanned monthly on a 3T MRI scanner for 1 year. T1 was measured using inversion recovery (T1 -IR) and variable flip angle (T1 -VFA) sequences and T2 was measured using a multi-echo spin echo (T2 -SE) sequence. For each vial in the phantom, accuracy errors (%bias) were determined by the relative differences in measured T1 and T2 times compared to reference values. Reproducibility was measured by the coefficient of variation (CV) of T1 and T2 measurements across monthly scans. Accuracy and reproducibility were mainly assessed on vials with relaxation times expected to be in physiological ranges at 3T. RESULTS: A strong linear correlation between measured and reference relaxation times was found for all sequences tested (R2  > 0.997). Baseline bias (and CV[%]) for T1 -IR, T1 -VFA and T2 -SE sequences were +2.0% (2.1), +6.5% (4.2), and +8.5% (1.9), respectively. CONCLUSIONS: The accuracy and reproducibility of T1 and T2 on the scanner were considered sufficient for the sequences tested. No longitudinal trends of variation were deduced, suggesting less frequent measurements are required following the establishment of baselines.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes
7.
Phys Imaging Radiat Oncol ; 18: 26-33, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34258404

RESUMO

BACKGROUND AND PURPOSE: Prediction of chemoradiotherapy response (CRT) in locally advanced rectal cancer would enable stratification of management. The purpose was to prospectively evaluate multi-parametric magnetic resonance imaging (MRI) assessment of tumour heterogeneity combining diffusion weighted imaging (DWI) and dynamic contrast enhanced (DCE) MRI for the prediction of CRT response in locally advanced rectal cancer. MATERIALS AND METHODS: Patients with Stage II or III rectal adenocarcinoma undergoing neoadjuvant CRT and surgery underwent MRI (DWI and DCE) before, during (week 3), and after CRT (1 week before surgery). Patients with histopathology tumour regression grade (TRG) 0-1 were classified as responders, and TRG 2-3 were classified as non-responders. A whole tumour voxel-wise technique was used to produce apparent diffusion coefficient (ADC) and Ktrans (Tofts model) histograms derived from DWI and DCE-MRI, respectively. Logistic regression was used to predict response status for ADC and Ktrans quantiles. RESULTS: Thirty-three patients were included in this analysis; 16 responders, and 17 non-responders. On heterogeneity analysis, odds of being a responder were significantly higher after CRT (before surgery) for higher ADC 75th (p = 0.049) and ADC 90th (p = 0.034) percentile values. The Ktrans quantiles were lower in non-responders than responders before and during CRT, and higher after CRT although no significant association with response status was observed (p ≥ 0.10). CONCLUSIONS: DWI-MRI after CRT (before surgery) incorporating a histogram analysis of whole tumour heterogeneity was predictive of CRT response in patients with locally advanced rectal cancer. DCE-MRI did not add value in response prediction. CLINICAL TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry (ANZCTR) number ACTRN12616001690448.

8.
Phys Eng Sci Med ; 44(3): 799-807, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34228255

RESUMO

The introduction of MRI linear accelerators (MR-linacs) and the increased use of MR imaging in radiotherapy, requires improved approaches to MRI-only radiotherapy. MRI provides excellent soft tissue visualisation but does not provide any electron density information required for radiotherapy dose calculation, instead MRI is registered to CT images to enable dose calculations. MRI-only radiotherapy eliminates registration errors and reduces patient discomfort, workload and cost. Electron density requirements may be addressed in different ways, from manually applying bulk density corrections, to more computationally intensive methods to produce substitute CT datasets (sCT), requiring additional sequences, increasing overall imaging time. Reducing MR imaging time would reduce potential artefacts from intrafraction motion and patient discomfort. The aim of this study was to assess the impact of reducing MR imaging time on a hybrid atlas-voxel sCT conversion for prostate MRI-only treatment planning, considering both anatomical and dosimetric parameters. 10 volunteers were scanned on a Siemens Skyra 3T MRI. Sequences included the 3D T2-weighted (T2-w) SPACE sequence used for sCT conversion as previously validated against CT, along with variations to this sequence in repetition time (TR), turbo factor, and combinations of these to reduce the imaging time. All scans were converted to sCT and were compared to the sCT from the original SPACE sequence, evaluating for anatomical changes and dosimetric differences for a standard prostate VMAT plan. Compared to the previously validated T2-w SPACE sequence, scan times were reduced by up to 80%. The external volume and bony anatomy were compared, with all but one sequence meeting a DICE coefficient of 0.9 or better, with the largest variations occurring at the edges of the external body volume. The generated sCT agreed with the gold standard sCT within an isocentre dose of 1% and a gamma pass rate of 99% for a 1%/1 mm gamma tolerance for all but one sequence. This study demonstrates that the MR imaging sequence time was able to be reduced by approximately 80% with similar dosimetric results.


Assuntos
Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Tomografia Computadorizada por Raios X
9.
J Med Imaging Radiat Oncol ; 65(1): 112-119, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33377303

RESUMO

INTRODUCTION: Recent advances in image guidance and adaptive radiotherapy could enable gantry-free radiotherapy using patient rotation. Gantry-free radiotherapy could substantially reduce the cost of radiotherapy systems and facilities. MRI guidance complements a gantry-free approach because of its ability to visualise soft tissue deformation during rotation. A potential barrier to gantry-free radiotherapy is patient acceptability, especially when combined with MRI. This study investigates human experiences of horizontal rotation within an MRI scanner. METHODS: Ten healthy human participants and nine participants previously treated with radiotherapy were rotated within an MRI scanner. Participants' anxiety and motion sickness was assessed before being rotated in 45-degree increments and paused, representing a multi-field intensity-modulated radiotherapy treatment. An MR image was acquired at each 45-degree angle. Following imaging, anxiety and motion sickness were re-assessed, followed by a comfort questionnaire and exit interview. The significance of the differences in anxiety and motion sickness pre- versus post-imaging was assessed using Wilcoxon signed-rank tests. Content analysis was performed on exit interview transcripts. RESULTS: Eight of ten healthy and eight of nine patient participants completed the imaging session. Mean anxiety scores before and after imaging were 7.9/100 and 11.8/100, respectively (P = 0.26), and mean motion sickness scores were 5.3/100 and 13.7/100, respectively (P = 0.02). Most participants indicated likely acceptance of rotation if MRI were to be used in a hypothetical treatment. Physical discomfort was reported to be the biggest concern. CONCLUSIONS: Horizontal rotation within an MRI scanner was acceptable for most (17/19) participants.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Rotação
10.
Phys Med Biol ; 65(23)2020 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-32998112

RESUMO

Tissue mimicking materials (TMMs), typically contained within phantoms, have been used for many decades in both imaging and therapeutic applications. This review investigates the specifications that are typically being used in development of the latest TMMs. The imaging modalities that have been investigated focus around CT, mammography, SPECT, PET, MRI and ultrasound. Therapeutic applications discussed within the review include radiotherapy, thermal therapy and surgical applications. A number of modalities were not reviewed including optical spectroscopy, optical imaging and planar x-rays. The emergence of image guided interventions and multimodality imaging have placed an increasing demand on the number of specifications on the latest TMMs. Material specification standards are available in some imaging areas such as ultrasound. It is recommended that this should be replicated for other imaging and therapeutic modalities. Materials used within phantoms have been reviewed for a series of imaging and therapeutic applications with the potential to become a testbed for cross-fertilization of materials across modalities. Deformation, texture, multimodality imaging and perfusion are common themes that are currently under development.


Assuntos
Imageamento por Ressonância Magnética , Imagem Multimodal , Mamografia , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único
11.
Med Phys ; 47(7): 3054-3063, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32277703

RESUMO

INTRODUCTION: This work describes the development of a novel radiomics phantom designed for magnetic resonance imaging (MRI) that can be used in a multicenter setting. The purpose of this study is to assess the stability and reproducibility of MRI-based radiomic features using this phantom across different MRI scanners. METHODS & MATERIALS: A set of phantoms were three-dimensional (3D) printed using MRI visible materials. One set of phantoms were imaged on seven MRI scanners and one was imaged on one MRI scanner. Radiomics analysis of the phantoms, which included first-order features, shape and texture features was performed. Intraclass correlation coefficient (ICC) was used to assess the stability of radiomic features across eight scanners and the reproducibility of two printed models on one scanner. Coefficient of variation (COV) was used to assess the reproducibility of radiomics measurements in the phantom on a single scanner. RESULTS: The phantom models provide sufficient signal-to-noise and contrast in all the tumor models permitting robust automatic segmentation. During a 12-month period of monitoring, the phantom material was stable with T1 and T2 of 150.7 ± 6.7 ms and 56.1 ± 3.9 ms, respectively. Of all the radiomic features computed, 34 of 69 had COV < 10%. Features from first-order statistics were the most robust in stability across the eight scanners with eight of 12 (67%) having high stability. About 29 of 50 (58%) texture features had high stability and no shape features had high stability features across the eight scanners. CONCLUSION: A novel MRI radiomics phantom has been developed to assess the reproducibility and stability of MRI-based radiomic features across multiple institutions. The variation in radiomic feature stability demonstrates the need for caution when interpreting these features for clinical studies.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Impressão Tridimensional , Reprodutibilidade dos Testes
12.
Front Oncol ; 9: 826, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31555587

RESUMO

Purpose: This project investigates the feasibility of implementation of MRI-only prostate planning in a prospective multi-center study. Method and Materials: A two-phase implementation model was utilized where centers performed retrospective analysis of MRI-only plans for five patients followed by prospective MRI-only planning for subsequent patients. Feasibility was assessed if at least 23/25 patients recruited to phase 2 received MRI-only treatment workflow. Whole-pelvic MRI scans (T2 weighted, isotropic 1.6 mm voxel 3D sequence) were converted to pseudo-CT using an established atlas-based method. Dose plans were generated using MRI contoured anatomy with pseudo-CT for dose calculation. A conventional CT scan was acquired subsequent to MRI-only plan approval for quality assurance purposes (QA-CT). 3D Gamma evaluation was performed between pseudo-CT calculated plan dose and recalculation on QA-CT. Criteria was 2%, 2 mm criteria with 20% low dose threshold. Gold fiducial marker positions for image guidance were compared between pseudo-CT and QA-CT scan prior to treatment. Results: All 25 patients recruited to phase 2 were treated using the MRI-only workflow. Isocenter dose differences between pseudo-CT and QA-CT were -0.04 ± 0.93% (mean ± SD). 3D Gamma dose comparison pass-rates were 99.7% ± 0.5% with mean gamma 0.22 ± 0.07. Results were similar for the two centers using two different scanners. All gamma comparisons exceeded the 90% pass-rate tolerance with a minimum gamma pass-rate of 98.0%. In all cases the gold fiducial markers were correctly identified on MRI and the distances of all seeds to centroid were within the tolerance of 1.0 mm of the distances on QA-CT (0.07 ± 0.41 mm), with a root-mean-square difference of 0.42 mm. Conclusion: The results support the hypothesis that an MRI-only prostate workflow can be implemented safely and accurately with appropriate quality assurance methods.

13.
Br J Radiol ; 92(1098): 20190056, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30912956

RESUMO

OBJECTIVE: PROMETHEUS (ACTRN12615000223538) is a multicentre clinical trial investigating the feasibility of 19 Gy in 2 fractions of stereotactic body radiotherapy (SBRT) as a boost technique for prostate cancer. The objective of this substudy was to evaluate intrafraction motion using cine MRI and assess the dosimetric impact of using a rectal displacement device (RDD). METHODS: The initial 10 patients recruited underwent planning CT and MRI, with and without a RDD. Cine MRI images were captured using an interleaved T2 HASTE sequence in sagittal and axial planes with a temporal resolution of 5.2 s acquired over 4.3 min. Points of interest (POIs) were defined and a validated tracking algorithm measured displacement of these points over the 4.3 min in the anteroposterior, superior-inferior and left-right directions. Plans were generated with and without a RDD to examine the impact on dosimetry. RESULTS: There was an overall trend for increasing displacement in all directions as time progressed when no RDD was in situ . points of interest remained comparatively stable with the RDD. In the sagittal plane, the RDD resulted in statistically significant improvement in the range of anteroposterior displacement for the rectal wall, anterior prostate, prostate apex and base. Dosimetrically, the use of a RDD significantly reduced rectal V16, V14 and Dmax, as well as the percentage of posterior rectal wall receiving 8.5 Gy. CONCLUSION: The RDD used in stereotactic prostate radiotherapy leads to reduced intrafraction motion of the prostate and rectum, with increasing improvement with time. It also results in significant improvement in rectal wall dosimetry. ADVANCES IN KNOWLEDGE: It was found that the rectal displacement device improved prostate stabilization significantly, improved rectum stabilization and dosimetry significantly. The rectal displacement device did not improve target volume dosimetry.


Assuntos
Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Pontos de Referência Anatômicos , Estudos de Viabilidade , Humanos , Imobilização/métodos , Imagem Cinética por Ressonância Magnética , Masculino , Movimento , Radiometria , Dosagem Radioterapêutica
14.
Phys Med Biol ; 64(7): 075010, 2019 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-30818301

RESUMO

This work describes the development and application of 3D printed MRI phantoms. Unlike traditional phantoms these test objects are made from solid materials which can be imaged directly without filling. The models were manufactured using both MRI visible and invisible materials. The MRI visible materials were imaged on a 3T system to quantify their T 1 and T 2 properties and CT to quantify the electron density. Three phantoms are described: a distortion phantom was imaged on an open bore MRI system to assess distortion over a 30 cm field-of-view; a solid tumour model was imaged using a motion simulator and compared to a standard water phantom to assess reduction in artefacts; finally, a test object created for textural analysis was evaluated on two 3T systems and reproducibility was assessed. Material 1 was the main material used in all phantom models and has a T 1 and T 2 of 152.3 ± 3.7 ms and 56.7 ± 2.5 ms and a CT density of 127.9 HU. Material 2 had a CT density of 115.1 HU and material 3 had a T 1 and T 2 of 149.5 ± 2.9 ms and 68.8 ± 7.8 ms and CT density of 15.3 HU. Image tests demonstrated the suitability and advantage of each phantom over more traditional versions: a high density set of control points enabled a comprehensive measurement of geometric accuracy; sufficient signal with a reduction in artefact was observed in the motion phantom, and the texture model provided reproducible measurements with an ICC > 0.9 for over 76% of texture features. Three different phantoms have been successfully manufactured and used to demonstrate the application of 3D printable materials for MRI phantoms.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Impressão Tridimensional/instrumentação , Artefatos , Humanos , Reprodutibilidade dos Testes , Software
15.
J Med Imaging Radiat Oncol ; 63(2): 264-271, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30609205

RESUMO

INTRODUCTION: This study quantified inter-observer contouring variations for multiple male pelvic structures, many of which are of emerging relevance for prostate cancer radiotherapy progression and toxicity response studies. METHODS: Five prostate cancer patient datasets (CT and T2-weighted MR) were distributed to 13 observers for contouring. CT structures contoured included the clinical target volume (CTV), seminal vesicles, rectum, colon, bowel bag, bladder and peri-rectal space (PRS). MR contours included CTV, trigone, membranous urethra, penile bulb, neurovascular bundle and multiple pelvic floor muscles. Contouring variations were assessed using the intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and multiple additional metrics. RESULTS: Clinical target volume (CT and MR), bladder, rectum and PRS contours showed excellent inter-observer agreement (median ICC = 0.97; 0.99; 1.00; 0.95; 0.90, DSC = 0.83 ± 0.05; 0.88 ± 0.05; 0.93 ± 0.03; 0.81 ± 0.07; 0.80 ± 0.06, respectively). Seminal vesicle contours were more variable (ICC = 0.75, DSC = 0.73 ± 0.14), while colon and bowel bag contoured volumes were consistent (ICC = 0.97; 0.97), but displayed poor overlap (DSC = 0.58 ± 0.22; 0.67 ± 0.21). Smaller MR structures showed significant inter-observer variations, with poor overlap for trigone, membranous urethra, penile bulb, and left and right neurovascular bundles (DSC = 0.44 ± 0.22; 0.41 ± 0.21; 0.66 ± 0.21; 0.16 ± 0.17; 0.15 ± 0.15). Pelvic floor muscles recorded moderate to strong inter-observer agreement (ICC = 0.50-0.97), although large outlier variations were observed. CONCLUSIONS: Inter-observer contouring variation was significant for multiple pelvic structures contoured on MR.


Assuntos
Pelve/anatomia & histologia , Pelve/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Pontos de Referência Anatômicos , Humanos , Imageamento por Ressonância Magnética , Masculino , Variações Dependentes do Observador , Tomografia Computadorizada por Raios X
16.
J Med Radiat Sci ; 65(1): 22-30, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29528199

RESUMO

INTRODUCTION: A magnetic resonance (MR) scanner for radiotherapy treatment simulation was commissioned in our department in June 2013. Practical set up and MR image quality trade-offs using a variety of patient positions and immobilisation devices routinely used in the treatment planning of rectal cancer patients were considered. The study also aimed to investigate the MR compatibility of the device materials with a focus on temperature changes during routine clinical examinations. METHODS: Ten volunteers were scanned: (1) Prone on a Civco Contoura Bellyboard (BBB), (2) Prone on a Civco MR Series Bellyboard (WBB), (3) Prone with no bellyboard and (4) Supine. All scans were performed with a T2 weighted (T2 -w) turbo spin echo (TSE) sequence. Images were scored by five assessors for: (1) ease of identifying specific organs, (2) overall image quality and (3) signal to noise ratio (SNR). Temperature changes were measured for each volunteer in each position. RESULTS: Both expert scores and SNR analysis demonstrated that images obtained in the supine position allowed for easier and clearer delineation of the organs. Image factors such as artefacts and noise, along with the overall image quality, also performed better in the supine position. The carbon fibre bellyboard did not demonstrate significant heating during scanning with the T2 -w TSE transverse sequence. CONCLUSIONS: A supine position was determined to be superior to the other positions in a majority of comparisons. The volunteers did not experience any increased temperature changes during scanning on the bellyboard in comparison to the other positions.


Assuntos
Imageamento por Ressonância Magnética , Posicionamento do Paciente , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/radioterapia , Artefatos , Humanos
17.
Phys Imaging Radiat Oncol ; 7: 70-75, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33458408

RESUMO

BACKGROUND AND PURPOSE: Four-dimensional (4D) computed tomography (CT) is widely used in radiotherapy (RT) planning and remains the current standard for motion evaluation. We assess a 4D magnetic resonance imaging (MRI) sequence in terms of motion and image quality in a phantom, healthy volunteers and patients undergoing RT. MATERIALS AND METHODS: The 4D-MRI sequence is a prototype T1-weighted 3D gradient echo with radial acquisition with self-gating. The accuracy of the 4D-MRI respiratory sorting based method was assessed using a MRI-CT compatible respiratory simulation phantom. In volunteers, abdominal viscera were evaluated for artefact, noise, structure delineation and overall image quality using a previously published four-point scoring system. In patients undergoing abdominal RT, the tumour (or a surrogate) was utilized to assess the range of motion on both 4D-CT and 4D-MRI. Furthermore, imaging quality was evaluated for both 4D-CT and 4D-MRI. RESULTS: In phantom studies 4D-MRI demonstrated amplitude of motion error of less than 0.2 mm for five, seven and ten bins. 4D-MRI provided excellent image quality for liver, kidney and pancreas. In patients, the median amplitude of motion seen on 4D-CT and 4D-MRI was 11.2 mm (range 2.8-20.3 mm) and 10.1 mm (range 0.7-20.7 mm) respectively. The median difference in amplitude between 4D-CT and 4D-MRI was -0.6 mm (range -3.4-5.2 mm). 4D-MRI demonstrated superior edge detection (median score 3 versus 1) and overall image quality (median score 2 versus 1) compared to 4D-CT. CONCLUSIONS: The prototype 4D-MRI sequence demonstrated promising results and may be used in abdominal targeting, motion gating, and towards implementing MRI-based adaptive RT.

18.
Med Phys ; 45(2): 758-766, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29237232

RESUMO

PURPOSE: Human cortical bone has a rapid T2∗ decay, and it can be visualized using ultrashort echo time (UTE) techniques in magnetic resonance imaging (MRI). These sequences operate at the limits of gradient and transmit-receive signal performance. Development of multicompartment anthropomorphic phantoms that can mimic human cortical bone can assist with quality assurance and optimization of UTE sequences. The aims of this study were to (a) characterize the MRI signal properties of a photopolymer resin that can be 3D printed, (b) develop multicompartment phantoms based on the resin, and (c) demonstrate the feasibility of using these phantoms to mimic human anatomy in the assessment of UTE sequences. METHODS: A photopolymer resin (Prismlab China Ltd, Shanghai, China) was imaged on a 3 Tesla MRI system (Siemens Skyra) to characterize its MRI properties with emphasis on T2∗ signal and longevity. Two anthropomorphic phantoms, using the 3D printed resin to simulate skeletal anatomy, were developed and imaged using UTE sequences. A skull phantom was developed and used to assess the feasibility of using the resin to develop a complex model with realistic morphological human characteristics. A tibia model was also developed to assess the suitability of the resin at mimicking a simple multicompartment anatomical model and imaged using a three-dimensional UTE sequence (PETRA). Image quality measurements of signal-to-noise ratio (SNR) and contrast factor were calculated and these were compared to in vivo values. RESULTS: The T2∗ and T1 (mean ± standard deviation) of the photopolymer resin was found to be 411 ± 19 µs and 74.39 ± 13.88 ms, respectively, and demonstrated no statistically significant change during 4 months of monitoring. The resin had a similar T2∗ decay to human cortical bone; however, had lower T1 properties. The bone water concentration of the resin was 59% relative to an external water reference phantom, and this was higher than in vivo values reported for human cortical bone. The multicompartment anthropomorphic head phantom was successfully produced and able to simulate realistic air cavities, bony anatomy, and soft tissue. Image quality assessment in the tibia phantom using the PETRA sequence showed the suitability of the resin to mimic human anatomy with high SNR and contrast making it suitable for tissue segmentation. CONCLUSIONS: A solid resin material, which can be 3D printed, has been found to have similar magnetic resonance signal properties to human cortical bone. Phantoms replicating skeletal anatomy were successfully produced using this resin and demonstrated their use for image quality and segmentation assessment of ultrashort echo time sequences.


Assuntos
Osso Cortical/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Impressão Tridimensional , Estudos de Viabilidade , Humanos , Fatores de Tempo
19.
Br J Radiol ; 90(1080): 20170037, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28937270

RESUMO

OBJECTIVE: To test a free-breathing MRI protocol for anatomical and functional assessment during lung cancer radiotherapy by assessing two non-Cartesian acquisition schemes based on T1 weighted 3D gradient recall echo sequence: (i) stack-of stars (StarVIBE) and (ii) spiral (SpiralVIBE) trajectories. METHODS: MR images on five healthy volunteers were acquired on a wide bore 3T scanner (MAGNETOM Skyra, Siemens Healthcare, Erlangen, Germany). Anatomical image quality was assessed on: (1) free breathing (StarVIBE), (2) the standard clinical sequence (volumetric interpolated breath-hold examination, VIBE) acquired in a 20 second (s) compliant breath-hold and (3) 20 s non-compliant breath-hold. For functional assessment, StarVIBE and the current standard breath-hold time-resolved angiography with stochastic trajectories (TWIST) sequence were run as multiphase acquisitions to replicate dynamic contrast enhancement (DCE) in one healthy volunteer. The potential application of the SpiralVIBE sequence for lung parenchymal imaging was assessed on one healthy volunteer. Ten patients with lung cancer were subsequently imaged with the StarVIBE and SpiralVIBE sequences for anatomical and structural assessment. For functional assessment, free-breathing StarVIBE DCE protocol was compared with breath-hold TWIST sequences on four prior lung cancer patients with similar tumour locations. Image quality was evaluated independently and blinded to sequence information by an experienced thoracic radiologist. RESULTS: For anatomical assessment, the compliant breath-hold VIBE sequence was better than free-breathing StarVIBE. However, in the presence of a non-compliant breath-hold, StarVIBE was superior. For functional assessment, StarVIBE outperformed the standard sequence and was shown to provide robust DCE data in the presence of motion. The ultrashort echo of the SpiralVIBE sequence enabled visualisation of lung parenchyma. CONCLUSION: The two non-Cartesian acquisition sequences, StarVIBE and SpiralVIBE, provide a free-breathing imaging protocol of the lung with sufficient image quality to permit anatomical, structural and functional assessment during radiotherapy. Advances in knowledge: Novel application of non-Cartesian MRI sequences for lung cancer imaging for radiotherapy. Illustration of SpiralVIBE UTE sequence as a promising sequence for lung structural imaging during lung radiotherapy.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Pulmão/anatomia & histologia , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador , Estudos de Viabilidade , Humanos , Movimento (Física) , Valores de Referência , Respiração
20.
BMC Cancer ; 17(1): 465, 2017 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-28676107

RESUMO

BACKGROUND: Response to neoadjuvant chemoradiotherapy (CRT) of rectal cancer is variable. Accurate imaging for prediction and early assessment of response would enable appropriate stratification of management to reduce treatment morbidity and improve therapeutic outcomes. Use of either diffusion weighted imaging (DWI) or dynamic contrast enhanced (DCE) imaging alone currently lacks sufficient sensitivity and specificity for clinical use to guide individualized treatment in rectal cancer. Multi-parametric MRI and analysis combining DWI and DCE may have potential to improve the accuracy of therapeutic response prediction and assessment. METHODS: This protocol describes a prospective non-interventional single-arm clinical study. Patients with locally advanced rectal cancer undergoing preoperative CRT will prospectively undergo multi-parametric MRI pre-CRT, week 3 CRT, and post-CRT. The protocol consists of DWI using a read-out segmented sequence (RESOLVE), and DCE with pre-contrast T1-weighted (VIBE) scans for T1 calculation, followed by 60 phases at high temporal resolution (TWIST) after gadoversetamide injection. A 3-dimensional voxel-by-voxel technique will be used to produce colour-coded ADC and Ktrans histograms, and data evaluated in combination using scatter plots. MRI parameters will be correlated with surgical histopathology. Histopathology analysis will be standardized, with chemoradiotherapy response defined according to AJCC 7th Edition Tumour Regression Grade (TRG) criteria. Good response will be defined as TRG 0-1, and poor response will be defined as TRG 2-3. DISCUSSION: The combination of DWI and DCE can provide information on physiological tumour factors such as cellularity and perfusion that may affect radiotherapy response. If validated, multi-parametric MRI combining DWI and DCE can be used to stratify management in rectal cancer patients. Accurate imaging prediction of patients with a complete response to CRT would enable a 'watch and wait' approach, avoiding surgical morbidity in these patients. Consistent and reliable quantitation from standardised protocols is essential in order to establish optimal thresholds of ADC and Ktrans and permit the role of multi-parametric MRI for early treatment prediction to be properly evaluated. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry (ANZCTR) number ACTRN12616001690448 (retrospectively registered 8/12/2016).


Assuntos
Protocolos Clínicos , Imageamento por Ressonância Magnética , Neoplasias Retais/diagnóstico por imagem , Terapia Combinada , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prognóstico , Estudos Prospectivos , Neoplasias Retais/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...