Ultrasound Obstet Gynecol ; 42(4): 375-82, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23754314

RESUMO

OBJECTIVES: To investigate the effect of endometrial scratching, performed during oral contraceptive pill (OCP) pretreatment, on reproductive outcome and on ultrasound markers of endometrial receptivity, and to assess the pain involved in the procedure, in unselected women undergoing assisted reproductive techniques (ART). METHODS: Women undergoing ART were randomly allocated to undergo either endometrial scratching with a pipelle de Cornier or a sham procedure, 7-14 days before starting controlled ovarian stimulation (COS). We evaluated subsequent rates of clinical pregnancy, live birth, implantation, miscarriage and multiple pregnancy. Pain during the procedure was evaluated using a 10-cm visual analog scale. Endometrial thickness and volume and three-dimensional power Doppler (3D-PD) indices (vascularization index (VI), flow index (FI) and vascularization flow index (VFI)) were assessed during COS when there was at least one follicle ≥ 17 mm in diameter. RESULTS: We included 158 women. Endometrial scratching was associated with higher rates of live birth (41.8% vs 22.8%, P = 0.01) and clinical pregnancy (49.4% vs 29.1%, P = 0.01) and higher pain score (6.42 ± 2.35 cm vs 1.82 ± 1.52 cm, P < 0.001), endometrial VI (3.71 ± 1.77 vs 2.95 ± 1.56, P < 0.01) and VFI (0.97 ± 0.51 vs 0.76 ± 0.40, P < 0.01). There was no significant effect of endometrial scratching on rate of miscarriage (15.4% vs 21.7%, P = 0.53) or multiple pregnancy (22.5% vs 25.0%, P = 0.79), or on endometrial thickness (10.12 ± 1.55 mm vs 9.98 ± 1.62 mm, P = 0.59), endometrial volume (6.18 ± 1.63 cm(3) vs 6.01 ± 1.48 cm(3) , P = 0.51) or FI (26.12 ± 2.82 vs 25.91 ± 2.72, P = 0.65). CONCLUSIONS: Endometrial scratching performed once, during OCP pretreatment 7-14 days before starting COS, increases the chance of live birth and clinical pregnancy, but might cause considerable pain.


Assuntos
Endométrio , Indução da Ovulação/métodos , Adulto , Anticoncepcionais Orais Hormonais/farmacologia , Estradiol/farmacologia , Estrogênios/farmacologia , Feminino , Humanos , Infertilidade Feminina/diagnóstico por imagem , Infertilidade Feminina/terapia , Levanogestrel/farmacologia , Nascido Vivo , Dor/etiologia , Gravidez , Resultado da Gravidez , Taxa de Gravidez , Ultrassonografia
3.
Ultrasound Obstet Gynecol ; 42(5): 571-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23362022

RESUMO

OBJECTIVES: To compare the variability in vascularization flow index (VFI) seen in serial acquisitions obtained using spatiotemporal image correlation (STIC) and using conventional static three-dimensional (3D) power Doppler (PD), for both in-vitro and in-vivo models, and to evaluate whether the curves formed by VFI values obtained from successive 'frames' in a STIC dataset are consistent and resemble the waveforms obtained by spectral Doppler analysis. METHODS: The study was divided into two parts: in the first part (the in-vitro model) we scanned a flow phantom, while in the second part (the in-vivo model) we scanned a common carotid artery. Conventional static 3D and STIC-PD datasets were alternately acquired from these two models. VFI values were assessed from 0.38-cm(3) spherical samples of the main flow region in the static 3D datasets and in every frame of the STIC datasets. The variance of the minimum, mean and maximum VFI values from each STIC dataset was compared with the variance of VFI values from the static 3D datasets. RESULTS: Ten static 3D and 10 STIC datasets were acquired from each model. Analysis of the in-vitro and in-vivo models showed a significant reduction in the variance of VFI values obtained using STIC as compared to static datasets. Additionally, we observed that the curves formed by VFI values obtained from successive frames in each STIC dataset were consistent across different datasets and that they resembled the waveforms obtained by spectral Doppler in both models. CONCLUSIONS: 3D-PD indices derived from STIC are more stable than those obtained from conventional static 3D-PD datasets. The curves of VFI throughout a reconstructed cardiac cycle using STIC are repeatable and resemble those obtained by spectral Doppler analysis of the vessel.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Ultrassonografia Doppler/métodos , Ultrassonografia Pré-Natal/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Imageamento Tridimensional/normas , Reprodutibilidade dos Testes , Ultrassonografia Doppler/normas , Ultrassonografia Pré-Natal/normas
4.
Ultrasound Obstet Gynecol ; 40(2): 200-6, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22173929

RESUMO

OBJECTIVE: To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. METHODS: Women with singleton pregnancies at 24-40 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm(3) of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm(3) of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). RESULTS: Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. CONCLUSION: Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited.


Assuntos
Imageamento Tridimensional/métodos , Placenta/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Ultrassonografia Pré-Natal/métodos , Feminino , Humanos , Variações Dependentes do Observador , Gravidez , Reprodutibilidade dos Testes
5.
Ultrasound Obstet Gynecol ; 38(1): 107-15, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21465609

RESUMO

OBJECTIVE: To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra- and interobserver reliability and agreement with regard to endometrial measurement. METHODS: Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL(™)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A- and C-planes using subjective assessment. RESULTS: Endometrial volume measurements using the SMV and A-plane were more reliable (intra- and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra- and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra- and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or 'comparable' (50 and 53.3%, respectively), but never more difficult than using the C-plane. CONCLUSIONS: Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane.


Assuntos
Endométrio/diagnóstico por imagem , Imageamento Tridimensional/métodos , Adulto , Endométrio/patologia , Feminino , Humanos , Imageamento Tridimensional/classificação , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Técnicas de Reprodução Assistida , Ultrassonografia , Adulto Jovem
6.
Ultrasound Obstet Gynecol ; 35(3): 361-8, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20084642

RESUMO

OBJECTIVES: To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in 'flow-free' models. METHODS: 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PRF) settings. RESULTS: Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. CONCLUSIONS: Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures.


Assuntos
Artefatos , Cor , Imageamento Tridimensional/instrumentação , Imagens de Fantasmas , Feminino , Humanos , Imageamento Tridimensional/métodos , Modelos Cardiovasculares , Ultrassonografia Doppler em Cores/métodos