Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Funct Biomater ; 13(4)2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36547547

RESUMO

Dental replacements are placed between the abutment teeth. The exceptions are two-unit bridges, as they are supported by a single tooth prepared only on one side of the missing tooth. The presented study deals with an analysis of a pressure force action on two-unit bridges placed in the frontal part (20 samples), where the pressure action is lower, and in the distal part (20 samples), where the pressure action is higher. A CAD program by 3Shape was used for digital designing with two different gap settings, 10 µm (20 samples) and 30 µm (20 samples). Two-unit bridges were attached to the prepared tooth using two types of dental cement (20/20 samples), which were selected for their physical and bioactive properties. All two-unit bridges (a total of 80 samples) were fabricated from CoCr alloys on Mlab cusing R by applying the Selective Laser Melting (SLM) technology. Mechanical testing was performed using the Inspekt5 table blue. The obtained data were used to verify the hypotheses-a difference between both types of cement (A ≠ B), a difference between the frontal and distal two-unit bridges (F ≠ D) and a difference between the gap sizes (10 ≠ 30). To confirm the given theories, data were statistically evaluated using the F-test and subsequent t-tests. The resulting p-value was compared with the level of significance (α = 0.05). A statistical evaluation revealed a significant difference between the compared groups; however, no explicit correlation between the individual groups of specimens was identified.

3.
J Biotechnol ; 322: 33-42, 2020 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-32673686

RESUMO

In recent years, the number of cervical interventions has increased. The stress shielding effect is a serious complication in cervical spine interventions. Topological optimization is based on finite element method structural analysis and numerical simulations. The generated design of cervical implants is made from Ti6Al4V powder by selective laser melting while the optimized cage is numerically tested for compressive axial loading and the results are compared with experimental measurement. Additive manufacturing technologies and new software possibilities in the field of structural analysis, which use the finite element method tools, help to execute implant topological optimization that is useful for clinical practice. The inner structures of the implant would be impossible to make by conventional manufacturing technologies. The resulting implant design, after modification, must fulfill strict application criteria for the area of cervical spine with respect to its material and biomechanical properties. The aim of this work was to alter the mechanical properties of the cervical intervertebral cage to address the clinical concern of the stress shielding effect by topological optimization. A methodology of cervical implant compressive axial loading numerical simulation was created, and subsequent experimental testing was done to obtain real material properties after a selective laser melting process. The weight of the optimized implant was reduced by 28.92 %. Results of the experimental testing and numerical simulation of topologically optimized design showed 10-times lower stiffness compared to the solid cage design, and the real yield strength of the optimized structure is 843.8 MPa based on experimental results.


Assuntos
Vértebras Cervicais/cirurgia , Simulação por Computador , Fixadores Internos , Desenho de Prótese/métodos , Fusão Vertebral/instrumentação , Ligas/química , Discotomia , Módulo de Elasticidade , Análise de Elementos Finitos , Humanos , Lasers , Teste de Materiais , Propriedades de Superfície , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...