Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Am Chem Soc ; 146(33): 23616-23624, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39136144

RESUMO

Magnetic materials are widely used for many technologies in energy, health, transportation, computation, and data storage. For the latter, the readout of the magnetic state of a medium is crucial. Optical readout based on the magneto-optical Faraday effect was commercialized but soon abandoned because of the need for a complex circular polarization-sensitive readout. Combining chirality with magnetism can remove this obstacle, as chiral magnetic materials exhibit magneto-chiral dichroism, a differential absorption of unpolarized light dependent on their magnetic state. Molecular chemistry allows the rational introduction of chirality into single-molecule magnets (SMMs), ultimate nanoobjects capable of retaining magnetization. Here, we report the first experimental demonstration of optical detection of the magnetic state of an SMM using unpolarized light on a novel air-stable Dy-based chiral SMM featuring a strong single-ion magnetic anisotropy. These findings might represent a paradigm shift in the field of optical data readout technologies.

2.
Inorg Chem ; 62(43): 17583-17587, 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37856861

RESUMO

Here we report magneto-chiral dichroism (MChD) detected through visible and near-infrared light absorption of a chiral dysprosium(III) coordination polymer. The two enantiomers of [DyIII(H6(py)2)(hfac)3]n [H6(py)2 = 2,15-bis(4-pyridyl)ethynylcarbo[6]helicene; hfac- = 1,1,1,5,5,5-hexafluoroacetylacetonate], where the chirality is provided by a functionalized helicene ligand, were structurally, spectroscopically, and magnetically investigated. Magnetic measurements reveal a slow relaxation of the magnetization, with differences between enantiopure and racemic systems rationalized on the basis of theoretical calculations. When the enantiopure complexes are irradiated with unpolarized light in a magnetic field, they exhibit multiple MChD signals associated with the f-f electronic transitions of DyIII, thus providing the coexistence of MChD-active absorptions and single-molecule-magnet (SMM) behavior. These findings clearly show the potential that rationally designed chiral SMMs have in enabling the optical readout of magnetic memory through MChD.

3.
Nanoscale ; 15(28): 12095-12104, 2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37424328

RESUMO

Because the combination of chiral and magnetic properties is becoming more and more attractive for magneto-chiral phenomena, we here aim at exploring the induction of chirality to achiral magnetic molecules as a strategy for the preparation of magneto-chiral objects. To this end, we have associated free base- and metallo-porphyrins with silica nano helices, using a variety of elaboration methods, and have studied them mainly by electronic natural circular dichroism (NCD) and magnetic circular dichroism (MCD) spectroscopies. While electrostatic or covalent surface grafting uniformly yielded very low induced CD (ICD) for the four assayed porphyrins, a moderate response was observed when the porphyrins were incorporated into the interior of the double-walled helices, likely due to the association of the molecules with the chirally-organized gemini surfactant. A generally stronger, but more variable, ICD was observed when the molecules were drop casted onto the helices immobilised on a quartz plate, likely due to the different capacities of the porphyrins to aggregate into chiral assemblies. Electronic spectroscopy, electron microscopy and IR spectroscopy were used to interpret the patterns of aggregation and their influence on ICD and MCD. No enhancement of MCD was observed as a result of association with the nanohelices except in the case of the free base, 5,10,15,20-tetra-(4-sulfonatophenyl)porphyrin (TPPS). This nanocomposite demonstrated a large ICD in the Soret region and a large MCD in the Q-region due to J-aggregation. However, no induced MChD was observed, possibly due to the spectral mismatch between the ICD and MCD peaks.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA