Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiovasc Electrophysiol ; 33(9): 1987-1991, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35726747

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation is performed worldwide. To attract patients, hospitals frequently have webpages that tout the success of the procedure. The information disseminated to the public via these webpages has not been systematically reviewed. Our objective was to assess accuracy of information delivered to the public on hospital websites in regard to atrial AF ablation. METHODS: From July 2019 to January 2020, we performed a Google search for all US hospitals registered with Medicare to see if they had a webpage describing AF ablation. Resulting hospital webpages were abstracted for data on AF ablation success rates and risks. Success rates over 86%, the highest success rate in the medical literature, were deemed exaggerated. RESULTS: Among 4805 hospitals, 487 had webpages describing AF ablation and 33 discussed success rates of AF ablation. Twelve percentage reported exaggerated success rates, 3% referred to ablation as a cure, and 2.8% referred to ablation as a tool to eliminate AF. Less than 10% of webpages describing AF ablation noted the potential need for a second ablation to achieve the stated success rate and merely 16% mentioned risks of the procedure. One percentage of webpages directly suggested AF ablation could reduce risk of stroke while others indirectly suggested it by discussing cessation of anticoagulation. Two webpages mentioned reduced mortality. CONCLUSION: US hospital webpages rarely discuss AF ablation. When discussed, there were concerning unsubstantiated claims regarding mortality, stroke prevention, and need for medical therapy. This could lead to some patients undergoing AF ablation based on faulty understanding.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Comunicação , Hospitais , Humanos , Medicare , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Estados Unidos
2.
Lung ; 198(1): 229-233, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31853638

RESUMO

PURPOSE: Pleural effusion is a common finding in patients with congestive heart failure (CHF). The pathogenesis of pleural effusion in heart failure is multifactorial. However, the role of right and left ventricular function assessed by ECHO cardiogram has not been studied. Therefore, we explored the association between right and left ventricular parameters on echocardiogram in patients with heart failure with and without pleural effusion diagnosed using CT scan of chest. METHODS: A case-control study was utilized to explore the objectives. Using strict exclusion criteria, patients admitted with a single diagnosis of acute CHF were stratified into those with and without pleural effusion using CT scan of chest done at admission. Multiple logistic regression analysis was used to identify significant factors associated with pleural effusion. RESULTS: Among the 70 patients, 36 (51%) had pleural effusions. The mean E/A ratio in patients with effusion (2.53 ± 1.1) was significantly higher than in patients without effusion (1.15 ± 0.9), p < 0.01. Multiple logistic regression analysis showed that elevated E/A ratio was significantly associated with pleural effusion, OR 3.26 (95% CI 1.57-6.77, p < 0.009). Left ventricular ejection fraction (LVEF), septal E', lateral E', and medial E/E' ratio were not significantly different in patients with and without pleural effusion. CONCLUSION: Elevated E/A ratio is a risk factor for the formation of pleural effusion in patients with heart failure.


Assuntos
Velocidade do Fluxo Sanguíneo , Insuficiência Cardíaca/fisiopatologia , Derrame Pleural/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Estudos de Casos e Controles , Diástole , Ecocardiografia , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Derrame Pleural/epidemiologia , Derrame Pleural/etiologia , Fatores de Risco , Tomografia Computadorizada por Raios X , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia
4.
Prog Cardiovasc Dis ; 62(3): 256-264, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31077726

RESUMO

Multiple clinical trials have demonstrated the efficacy of implantable cardioverter-defibrillators (ICDs) for the prevention of sudden cardiac death (SCD) among specific high-risk populations. However, it remains unclear how to optimally treat those patients who are at elevated risk of cardiac arrest but are not among the presently identified groups proven to benefit from an ICD, are unable to tolerate surgical device implantation, or refuse invasive therapies. The wearable cardioverter-defibrillator (WCD) is an alternative antiarrhythmic device that provides continuous cardiac monitoring and defibrillation capabilities through a noninvasive, electrode-based system. The WCD has been shown to be highly effective at restoration of sinus rhythm in patients with a ventricular tachyarrhythmia, and one randomized trial using the WCD in patients with recent myocardial infarction at elevated risk for arrhythmic death reported a decrease in overall mortality despite no SCD mortality benefit. The current clinical indications for WCD use are varied and continue to evolve as experience with this technology increases.


Assuntos
Desfibriladores , Dispositivos Eletrônicos Vestíveis , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Desenho de Equipamento , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Dispositivos Eletrônicos Vestíveis/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...