Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Nutr Metab Cardiovasc Dis ; 31(2): 658-665, 2021 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-33358714

RESUMO

BACKGROUND AND AIMS: The first hybrid artificial pancreas (AP) systems with insulin only (mono-hormonal) have recently reached the market while next generations systems are under development including those with glucagon addition (bi-hormonal). Understanding the expectations and impressions of future potential users about AP systems is important for optimal use of this clinically effective emerging technology. METHODS AND RESULTS: An online survey about AP systems which consisted of 50 questions was addressed to people with type 1 diabetes in the province of Quebec, Canada. Surveys were completed by 123 respondents with type 1 diabetes (54% women, mean (SD) age 40.2 (14.4) y.o., diabetes duration 23.7 (14.1) years, 58% insulin pump users and 43% glucose sensor users). Of the respondents, 91% understood how AP systems work, 79% trusted them with correct insulin dosing, 73% were willing to replace their current treatment with AP and 80% expected improvement in quality of life. Anxiety about letting an algorithm control their glucose levels was expressed by 18% while the option of ignoring or modifying AP instructions was favoured by 88%. As for bi-hormonal AP systems, 83% of respondents thought they would be useful to further reduce hypoglycemic risks. CONCLUSIONS: Overall, respondents expressed positive views about AP systems use and high expectations for a better quality of life, glycemic control and hypoglycemia reduction. Data from this survey could be useful to health care professionals and developers of AP systems.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon/uso terapêutico , Conhecimentos, Atitudes e Prática em Saúde , Hipoglicemiantes/uso terapêutico , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Pâncreas Artificial , Aceitação pelo Paciente de Cuidados de Saúde , Adulto , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/psicologia , Feminino , Glucagon/efeitos adversos , Pesquisas sobre Atenção à Saúde , Humanos , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Internet , Masculino , Pessoa de Meia-Idade , Pâncreas Artificial/efeitos adversos , Preferência do Paciente , Qualidade de Vida , Quebeque
3.
J Clin Endocrinol Metab ; 101(1): 214-23, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26523526

RESUMO

CONTEXT: The added benefit of glucagon in artificial pancreas systems for overnight glucose control in type 1 diabetes has not been fully explored. OBJECTIVE: The objective of the study was to compare the efficacy of dual-hormone (insulin and glucagon) artificial pancreas, single-hormone (insulin alone) artificial pancreas, and conventional insulin pump therapy. DESIGN: This study was a three-center, three-arm, open-label, randomized, crossover controlled trial involving three interventions, each applied over a night after a high carbohydrate/high fat meal and a second after exercise to mimic real-life glycemic excursions. SETTING: The study was conducted in a home setting. PATIENTS: Twenty-eight type 1 diabetes participants (21 adults and seven adolescents) participated in the study. INTERVENTIONS: Dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional pump therapy was activated from 9:00 PM to 7:00 AM. MAIN OUTCOME: The main outcome was a proportion of time in target (4-8 mmol/L) by continuous glucose monitoring from 11:00 PM to 7:00 AM. Analysis was by intention to treat. RESULTS: The median (interquartile range) percentage of time-in-target glucose range was 47% (36%-71%) for conventional therapy, higher on both single-hormone (76% [65%-91%], P < .001) and dual-hormone artificial pancreas (81 [68%-93%], P < .001). The median (interquartile range) time spent below 4 mmol/L was 14% (4%-28%) for conventional therapy, lower on both single-hormone (5% [0%-13%], P = .004) and dual-hormone artificial pancreas (1% [0%-8%], P < .001). There were 14 hypoglycemic events on conventional therapy compared with six incidences on the single-hormone artificial pancreas (P = .059) and three incidences on the dual-hormone artificial pancreas (P = .017). None of these outcomes differed significantly between single- and dual-hormone configurations. CONCLUSIONS: Single- and dual-hormone artificial pancreas systems both provided better glucose control than conventional therapy. Although the dual-hormone configuration did not increase overnight time-in-target glucose levels, an effect on lowering hypoglycemia risk cannot be ruled out.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Pâncreas Artificial , Adolescente , Adulto , Idoso , Glicemia/metabolismo , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Carboidratos da Dieta , Gorduras na Dieta , Sistemas de Liberação de Medicamentos , Exercício Físico/fisiologia , Feminino , Glucagon/uso terapêutico , Humanos , Insulina/administração & dosagem , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...