Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; : 173333, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38763199

RESUMO

This paper reports on development of an optical biosensor for the detection of antibodies against SARS-CoV-2 virus proteins in blood serum. ZnO nanotetrapods with high surface area and stable room temperature photoluminescence (PL) were selected as transducers. Structure and optical properties of the ZnO tetrapods have been studied by XRD, SEM and Raman spectroscopy. Crystallinity, dimensions and emission peaks of the ZnO tetrapods were determined. The ZnO tetrapods were fixed on glass chip. Silanization of ZnO tetrapods surface resulted in forming of functional surface groups suitable for the immobilization of bioselective layer. Two types of recombinant proteins (rS and rN) have been used to form bioselective layer on the surface of the ZnO tetrapods. Flow through microfluidic system, integrated with optical system, has been used for the determination of antibodies against SARS-CoV-2 virus proteins present in blood samples. The SARS-CoV-2 probes, prepared in PBS solution, have been injected into the measurement chamber with a constant pumping speed. Steady-state photoluminescence spectra and photoluminescence kinetics have been studied before and after injection of the probes. The biosensor signal has been tested to anti-SARS-CoV-2 antibodies in the range of 0.001 nM-1 nM. Control measurements have been performed with blood serum of healthy person. Sensitivity tests showed that ZnO-SARS-CoV-2-rS and ZnO-SARS-CoV-2-rN biosensors showed sensitivity to proteins showed higher stability and sensitivity to anti-SARS-CoV-2 antibodies in the range of 0.025-0.5 nM (LOD 0.01 nM) and 0.3-1 nM (LOD 0.3 nM), respectively. Gibbs free energy of interaction between ZnO/SARS-CoV-2-rS and ZnO/SARS-CoV-2-rN bioselective layers with anti-SARS-CoV-2 antibodies showed -35.5 and -21.4 kJ/mol, respectively. Average detection time of biosensor integrated within microfluidic system was 15-20 min. The detection time and pumping speed (50 µl/min) could be reduced to make detection faster. The developed system and ZnO-SARS-CoV-2-rS nanostructures have good potential for detection of anti-SARS-CoV-2 antibodies from patient's probes.

2.
Biosensors (Basel) ; 14(3)2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38534241

RESUMO

Two types of low-cost reagentless electrochemical glucose biosensors based on graphite rod (GR) electrodes were developed. The electrodes modified with electrochemically synthesized platinum nanostructures (PtNS), 1,10-phenanthroline-5,6-dione (PD), glucose oxidase (GOx) without and with a polypyrrole (Ppy) layer-(i) GR/PtNS/PD/GOx and (ii) GR/PtNS/PD/GOx/Ppy, respectively, were prepared and tested. Glucose biosensors based on GR/PtNS/PD/GOx and GR/PtNS/PD/GOx/Ppy electrodes were characterized by the sensitivity of 10.1 and 5.31 µA/(mM cm2), linear range (LR) up to 16.5 and 39.0 mM, limit of detection (LOD) of 0.198 and 0.561 mM, good reproducibility, and storage stability. The developed glucose biosensors based on GR/PtNS/PD/GOx/Ppy electrodes showed exceptional resistance to interfering compounds and proved to be highly efficient for the determination of glucose levels in blood serum.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Glucose/química , Polímeros/química , Pirróis/química , Platina , Reprodutibilidade dos Testes , Eletrodos , Glucose Oxidase/química , Enzimas Imobilizadas/química
3.
Biosensors (Basel) ; 14(3)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38534245

RESUMO

This paper describes the study of an amperometric glucose biosensor based on an enzymatic biofuel cell consisting of a bioanode and a biocathode modified with the same enzyme-glucose oxidase (GOx). A graphite rod electrode (GRE) was electrochemically modified with a layer of Prussian blue (PB) nanoparticles embedded in a poly(pyrrole-2-carboxylic acid) (PPCA) shell, and an additional layer of PPCA and was used as the cathode. A GRE modified with a nanocomposite composed of poly(1,10-phenanthroline-5,6-dione) (PPD) and gold nanoparticles (AuNPs) entrapped in a PPCA shell was used as an anode. Both electrodes were modified with GOx by covalently bonding the enzyme to the carboxyl groups of PPCA. The developed biosensor exhibited a wide linear range of 0.15-124.00 mM with an R2 of 0.9998 and a sensitivity of 0.16 µA/mM. The limit of detection (LOD) and quantification (LOQ) were found to be 0.07 and 0.23 mM, respectively. The biosensor demonstrated exceptional selectivity to glucose and operational stability throughout 35 days, as well as good reproducibility, repeatability, and anti-interference ability towards common interfering substances. The studies on human serum demonstrate the ability of the newly designed biosensor to determine glucose in complex real samples at clinically relevant concentrations.


Assuntos
Fontes de Energia Bioelétrica , Técnicas Biossensoriais , Grafite , Nanopartículas Metálicas , Humanos , Glucose , Ouro/química , Reprodutibilidade dos Testes , Nanopartículas Metálicas/química , Enzimas Imobilizadas/química , Glucose Oxidase/química , Eletrodos
4.
Sci Total Environ ; 924: 171042, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38369150

RESUMO

The emergence of COVID-19 caused by the coronavirus SARS-CoV-2 has prompted a global pandemic that requires continuous research and monitoring. This study presents a design of an electrochemical biosensing platform suitable for the evaluation of monoclonal antibodies targeting the SARS-CoV-2 nucleocapsid (N) protein. Screen-printed carbon electrodes (SPCE) modified with gold nanostructures (AuNS) were applied to design a versatile and sensitive sensing platform. Electrochemical techniques, including electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV), were used to investigate the interactions between immobilised recombinant N (rN) protein and several monoclonal antibodies (mAbs). The electrochemical characterisation of SPCE/AuNS/rN demonstrated a successful immobilisation of rN, enhancing the electron transfer kinetics. Affinity interactions between immobilised rN and four mAbs (mAb-4B3, mAb-4G6, mAb-12B2, and mAb-1G5) were explored. Although mAb-4B3 showed some non-linearity, the other monoclonal antibodies exhibited specific and well-defined interactions followed by the formation of an immune complex. The biosensing platform demonstrated high sensitivity in the linear range (LR) from 0.2 nM to 1 nM with limits of detection (LOD) ranging from 0.012 nM to 0.016 nM for mAb-4G6, mAb-12B2, and mAb-1G5 and limits of quantification (LOQ) values ranging from 0.035 nM to 0.139 nM, as determined by both EIS and SWV methods. These results highlight the system's potential for precise and selective detection of monoclonal antibodies specific to the rN. This electrochemical biosensing platform provides a promising route for the sensitive and accurate detection of monoclonal antibodies specific to the rN protein.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , SARS-CoV-2 , Anticorpos Monoclonais , Limite de Detecção , Técnicas Eletroquímicas/métodos , Carbono , Técnicas Biossensoriais/métodos , Eletrodos
5.
Biosens Bioelectron ; 251: 116043, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38368643

RESUMO

This article aims to present a comparative study of three polypyrrole-based molecularly imprinted polymer (MIP) systems for the detection of the recombinant severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid protein (rN). The rN is known for its relatively low propensity to mutate compared to other SARS-CoV-2 antigens. The aforementioned systems include screen-printed carbon electrodes (SPCE) modified with gold nanostructures (MIP1), platinum nanostructures (MIP2), and the unmodified SPCE (MIP3), which was used for control. Pulsed amperometric detection (PAD) was employed as the detection technique, offering the advantage of label-free detection without the need for an additional redox probe. Calibration curves were constructed using the obtained data to evaluate the response of each system. Non-imprinted systems were also tested in parallel to evaluate the contribution of non-specific binding and assess the affinity sensor's efficiency. The analysis of calibration curves revealed that the AuNS-based MIP1 system exhibited the lowest contribution of non-specific binding and displayed a better fit with the chosen fitting model compared to the other systems. Further analysis of this system included determining the limit of detection (LOD) (51.2 ± 2.8 pg/mL), the limit of quantification (LOQ) (153.9 ± 8.3 pg/mL), and a specificity test using a recombinant receptor-binding domain of SARS-CoV-2 spike protein as a control. Based on the results, the AuNS-based MIP1 system demonstrated high specificity and sensitivity for the label-free detection of SARS-CoV-2 nucleocapsid protein. The utilization of PAD without the need for additional redox probes makes this sensing system convenient and valuable for rapid and accurate virus detection.


Assuntos
Técnicas Biossensoriais , COVID-19 , Glicoproteína da Espícula de Coronavírus , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Polímeros/química , Pirróis , Proteínas do Nucleocapsídeo/análise
6.
Bioelectrochemistry ; 156: 108638, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38176325

RESUMO

In this research, various electrodeposition techniques were used to form gold nanostructures (AuNSs) on the surface of graphite rod electrode (GE). Three distinct AuNS morphologies on GE have been achieved based on the composition of electrodeposition solution. The use of H2SO4 as a supporting electrolyte resulted in the formation of smaller but more numerous AuNSI with a modified electrode's electroactive surface area (EASA) of 0.213 cm2. Exchanging the supporting electrolyte to KNO3 and increasing HAuCl4 concentration facilitated the formation of bigger AuNSII particles with electrode EASA of 0.116 cm2. Finally, a partial coverage of GE by branched gold nanostructures (AuNSIII) was achieved with an estimated EASA of 0.110 cm2, when the HAuCl4 and KNO3 concentrations were increased further. Estimated values of heterogeneous electron transfer rate constant did not depend on AuNS morphology. Electrode modified with AuNSI exhibited the highest bovine serum albumin (BSA) immobilization efficiency and the highest relative response for the detection of specific polyclonal antibodies against BSA (p-anti-BSA) compared to other modified electrodes. The limit of p-anti-BSA detection in PBS buffer was calculated as 0.63 nM, while in blood serum it was 0.71 nM. Linear ranges were from 1 to 7 nM and from 1 to 5 nM, respectively.


Assuntos
Técnicas Biossensoriais , Grafite , Nanopartículas Metálicas , Nanoestruturas , Ouro/química , Técnicas Biossensoriais/métodos , Limite de Detecção , Imunoensaio/métodos , Nanoestruturas/química , Grafite/química , Anticorpos , Eletrólitos , Técnicas Eletroquímicas/métodos , Eletrodos , Nanopartículas Metálicas/química
7.
Int J Mol Sci ; 25(2)2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38256053

RESUMO

To effectively control and prevent diseases on a global scale, it is essential to employ precise, sensitive, selective, and rapid immunoanalytical methods [...].


Assuntos
Alergia e Imunologia , Biologia Computacional
8.
Biosens Bioelectron ; 246: 115848, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38042053

RESUMO

This review addresses the design of immunosensors, which employ ZnO nanostructures. Various methods of modifying ZnO nanostructures with antibodies or antigens are discussed, including covalent and non-covalent approaches and cross-linking techniques. Immunosensors based on different properties of ZnO nanomaterials are described and compared. This article provides a comprehensive review of electrochemical immunosensors based on ZnO nanostructures and various detection techniques, including cyclic voltammetry (CV), differential pulse voltammetry (DPV), photoelectrochemical (PEC) detection, electrochemical impedance spectroscopy (EIS), and other electrochemical methods. In addition, this review article examines the application of optical detection techniques, including photoluminescence (PL) and electrochemiluminescence (ECL), in the development of immunosensors based on ZnO nanostructures.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Óxido de Zinco , Técnicas Biossensoriais/métodos , Óxido de Zinco/química , Imunoensaio/métodos , Nanoestruturas/química , Anticorpos/química , Técnicas Eletroquímicas
9.
Biosensors (Basel) ; 13(10)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37887135

RESUMO

Precise blood glucose detection plays a crucial role in diagnosing and medicating diabetes, in addition to aiding diabetic patients in effectively managing their condition. In this research, a first-generation reagentless amperometric glucose biosensor was developed by combining the graphite rod (GR) electrode modification by gold nanostructures (AuNS) and Prussian blue (PB) with glucose oxidase (GOx)-an enzyme that can oxidize glucose and produce H2O2. Firstly, AuNS was electrochemically deposited on the GR electrode (AuNS/GR), and then PB was electrochemically synthesized on the AuNS/GR electrode (PB/AuNS/GR). Finally, GOx was immobilized over the PB/AuNS nanocomposite with the assistance of Nafion (Nf) (Nf-GOx/PB/AuNS/GR). An application of PB in the design of a glucose biosensor enables an easy electrochemical reduction and, thus, the determination of the H2O2 produced during the GOx-catalyzed oxidation of glucose in the sample at a low operation potential of -0.05 V vs. Ag/AgCl/KCl3 mol L-1. In addition, AuNS increased the electrochemically active surface area, improved the GOx immobilization and ensured a higher analytical signal. The developed glucose biosensor based on the Nf-GOx/PB/AuNS/GR electrode exhibited a wide linear range, from 0.025 to 1 mmol L-1 of glucose, with a 0.0088 mmol L-1 limit of detection, good repeatability and high selectivity over electroactive interfering substances. The developed biosensor is convenient for the determination of glucose in the physiological environment.


Assuntos
Técnicas Biossensoriais , Grafite , Nanocompostos , Humanos , Glucose/química , Glucose Oxidase/química , Ouro/química , Peróxido de Hidrogênio , Enzimas Imobilizadas/química , Nanocompostos/química , Grafite/química , Eletrodos
10.
Int J Mol Sci ; 24(17)2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37686023

RESUMO

The profound understanding and detailed evaluation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike (SCoV2-S) protein and specific antibody interaction mechanism is of high importance in the development of immunosensors for COVID-19. In the present work, we studied a model system of immobilized SCoV2-S protein and specific monoclonal antibodies by molecular dynamics of immune complex formation in real time. We simultaneously applied spectroscopic ellipsometry and quartz crystal microbalance with dissipation to reveal the features and steps of the immune complex formation. We showed direct experimental evidence based on acoustic and optical measurements that the immune complex between covalently immobilized SCoV2-S and specific monoclonal antibodies is formed in two stages. Based on these findings it was demonstrated that applying a two-step binding mathematical model for kinetics analysis leads to a more precise determination of interaction rate constants than that determined by the 1:1 Langmuir binding model. Our investigation showed that the equilibrium dissociation constants (KD) determined by a two-step binding model and the 1:1 Langmuir model could differ significantly. The reported findings can facilitate a deeper understanding of antigen-antibody immune complex formation steps and can open a new way for the evaluation of antibody affinity towards corresponding antigens.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , Glicoproteína da Espícula de Coronavírus , Complexo Antígeno-Anticorpo , Afinidade de Anticorpos , Imunoensaio , SARS-CoV-2 , Anticorpos Monoclonais
11.
Bioengineering (Basel) ; 10(9)2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37760103

RESUMO

Articular cartilage is an avascular tissue with a limited capacity for self-regeneration, leading the tissue to osteoarthritis (OA). Mesenchymal stem cells (MSCs) are promising for cartilage tissue engineering, as they are capable of differentiating into chondrocyte-like cells and secreting a number of active molecules that are important for cartilage extracellular matrix (ECM) synthesis. The aim of this study was to evaluate the potential of easily accessible menstrual blood-derived MSC (MenSC) paracrine factors in stimulating bone marrow MSC (BMMSCs) chondrogenic differentiation and to investigate their role in protecting cartilage from degradation in vitro. MenSCs and BMMSCs chondrogenic differentiation was induced using four different growth factors: TGF-ß3, activin A, BMP-2, and IGF-1. The chondrogenic differentiation of BMMSCs was stimulated in co-cultures with MenSCs and cartilage explants co-cultured with MenSCs for 21 days. The chondrogenic capacity of BMMSCs was analyzed by the secretion of four growth factors and cartilage oligomeric matrix protein, as well as the release and synthesis of cartilage ECM proteins, and chondrogenic gene expression in cartilage explants. Our results suggest that MenSCs stimulate chondrogenic response in BMMSCs by secreting activin A and TGF-ß3 and may have protective effects on cartilage tissue ECM by decreasing the release of GAGs, most likely through the modulation of activin A related molecular pathway. In conclusion, paracrine factors secreted by MenSCs may turn out to be a promising therapeutical approach for cartilage tissue protection and repair.

12.
Biosensors (Basel) ; 13(8)2023 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-37622870

RESUMO

The spike (S) protein and its receptor-binding domain (RBD) of the coronavirus SARS-CoV-2 have been continually evolving, yielding the majority of significant missense mutations and new variants of concern. In this study, we examined how monoclonal antibodies against RBD (mAbs-SCoV2-RBD) and polyclonal antibodies present in convalescent human serum specifically interact with the S protein of wild-type and SARS-CoV-2 variants of concern (VOCs) in real time and how this can be reflected through surface mass density. Moreover, we combined two distinct, label-free measurement techniques: one based on changes in surface electromagnetic waves after reflection from the surface, and the other on changes in acoustic waves. The results demonstrated that dry surface mass density (ΓSE) of mAbs-SCoV2-RBD attached to the RBD of the S protein decreases three-fold, from 148 ng/cm2 to 46 ng/cm2, due to the B.1.351 or so-called beta mutation of coronavirus and its S protein (SCoV2-ß). Consequently, the obtained wet mass ΓQCM-D resulted in values two times lower, from 319 ng/cm2 to 158 ng/cm2, and the hydration of mAbs-SCoV2-RBD/SCoV2-ß immune complex was 70.88%. Conversely, when polyclonal antibodies present in convalescent human serum form immune complexes with the S protein of SARS-CoV-2 variants of concern, the ΓSE decreased from 279 ng/cm2 to 249 ng/cm2, and ΓQCM-D from 1545 ng/cm2 to 1366 ng/cm2. These results can give insights into the differences between the interaction of monoclonal and polyclonal antibodies with SARS-CoV-2 VOCs.


Assuntos
Anticorpos Monoclonais , COVID-19 , Humanos , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus
13.
Biosensors (Basel) ; 13(7)2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37504125

RESUMO

Reagentless electrochemical glucose biosensors were developed and investigated. A graphite rod (GR) electrode modified with electrochemically synthesized dendritic gold nanostructures (DGNs) and redox mediators (Med) such as ferrocenecarboxylic acid (FCA), 1,10-phenathroline-5,6-dione (PD), N,N,N',N'-tetramethylbenzidine (TMB) or tetrathiafulvalene (TTF) in combination with glucose oxidase (GOx) (GR/DGNs/FCA/GOx, GR/DGNs/PD/GOx, GR/DGNs/TMB/GOx, or GR/DGNs/TTF/GOx) were developed and electrochemically investigated. A biosensor based on threefold-layer-by-layer-deposited PD and GOx (GR/DGNs/(PD/GOx)3) was found to be the most suitable for the determination of glucose. To improve the performance of the developed biosensor, the surface of the GR/DGNs/(PD/GOx)3 electrode was modified with polypyrrole (Ppy) for 5 h. A glucose biosensor based on a GR/DGNs/(PD/GOx)3/Ppy(5 h) electrode was characterized using a wide linear dynamic range of up to 39.0 mmol L-1 of glucose, sensitivity of 3.03 µA mM-1 cm-2, limit of detection of 0.683 mmol L-1, and repeatability of 9.03% for a 29.4 mmol L-1 glucose concentration. The Ppy-based glucose biosensor was characterized by a good storage stability (τ1/2 = 9.0 days). Additionally, the performance of the developed biosensor in blood serum was investigated.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Glucose/química , Polímeros/química , Ouro/química , Enzimas Imobilizadas/química , Pirróis/química , Eletrodos , Glucose Oxidase/química
14.
Polymers (Basel) ; 15(11)2023 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-37299369

RESUMO

Bone marrow mesenchymal stem cells (BMMSCs) possess a strong ability to differentiate into the chondrogenic lineage, which is important for cartilage regeneration. External stimuli, such as electrical stimulation (ES), are frequently studied for chondrogenic differentiation of BMMSCs; however, the application of conductive polymers such as polypyrrole (Ppy), has never been used for stimulating BMMSCs chondrogenesis in vitro before. Thus, the aim of this study was to evaluate the chondrogenic potential of human BMMSCs after stimulation with Ppy nanoparticles (Ppy NPs) and compare them to cartilage-derived chondrocytes. In this study, we tested Ppy NPs without and with 13 nm gold NPs (Ppy/Au) for BMMSCs and chondrocyte proliferation, viability, and chondrogenic differentiation for 21 days, without the use of ES. The results demonstrated significantly higher amounts of cartilage oligomeric matrix protein (COMP) in BMMSCs stimulated with Ppy and Ppy/Au NPs, as compared to the control. The expression of chondrogenic genes (SOX9, ACAN, COL2A1) in BMMSCs and chondrocytes were upregulated by Ppy and Ppy/Au NPs, as compared to controls. Histological staining with safranin-O indicated higher extracellular matrix production in Ppy and Ppy/Au NPs stimulated samples, as compared to controls. In conclusion, Ppy and Ppy/Au NPs stimulate BMMSC chondrogenic differentiation; however, BMMSCs were more responsive to Ppy, while chondrocytes possessed a stronger chondrogenic response to Ppy/Au NPs.

15.
Nanomaterials (Basel) ; 13(12)2023 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-37368306

RESUMO

Maxillary sinus augmentation is a commonly used procedure for the placement of dental implants. However, the use of natural and synthetic materials in this procedure has resulted in postoperative complications ranging from 12% to 38%. To address this issue, we developed a novel calcium deficient HA/ß-TCP bone grafting nanomaterial using a two-step synthesis method with appropriate structural and chemical parameters for sinus lifting applications. We demonstrated that our nanomaterial exhibits high biocompatibility, enhances cell proliferation, and stimulates collagen expression. Furthermore, the degradation of ß-TCP in our nanomaterial promotes blood clot formation, which supports cell aggregation and new bone growth. In a clinical trial involving eight cases, we observed the formation of compact bone tissue 8 months after the operation, allowing for the successful installation of dental implants without any early postoperative complications. Our results suggest that our novel bone grafting nanomaterial has the potential to improve the success rate of maxillary sinus augmentation procedures.

16.
Biosens Bioelectron ; 234: 115370, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37163879

RESUMO

This paper reports the development of a novel surface plasmon resonance (SPR) immunosensor for ultra-sensitive quantitative determination of human articular cartilage oligomeric matrix protein (COMP), a major component of the extracellular matrix and an exploratory biomarker. Capture antibodies against human COMP (anti-COMP16F12) were covalently immobilized on an 11-mercaptoundecanoic acid (11-MUA) self-assembled monolayer (SAM)-coated SPR sensor disk and a dual sandwich-type signal amplification strategy using biotinylated detection antibodies against COMP (anti-COMP17C10-biot) and streptavidin-conjugated quantum dots (SAv‒QDs) were used for the development of an immunosensor. The binding of high-mass SAv‒QDs via biotin-streptavidin interaction to the surface of the immunosensor resulted in a drastic increase in the sensitivity. The developed immunosensor was able to detect concentrations of COMP in a range from 2.80 to 680.54 fM with a limit of detection (LOD) and a limit of quantification (LOQ) of 0.15 and 0.50 fM, respectively. The immunosensor exhibited good repeatability (relative standard deviation (RSD) 8.05%) and reproducibility (RSD 9.88%) as well as excellent operational stability (2.14 % decrease in SPR signal after 13 days). In addition, the analysis of secretomes of human knee articular cartilage explants from patients with osteoarthritis revealed that the immunosensor has good accuracy (analytical error less than 5 %). These results indicate that the immunosensor developed may be suitable for quantitative determination of COMP derived from articular cartilage and other synovial joint tissues in clinical studies.


Assuntos
Técnicas Biossensoriais , Ressonância de Plasmônio de Superfície , Humanos , Ressonância de Plasmônio de Superfície/métodos , Proteína de Matriz Oligomérica de Cartilagem , Técnicas Biossensoriais/métodos , Estreptavidina , Reprodutibilidade dos Testes , Imunoensaio/métodos , Biomarcadores
17.
Polymers (Basel) ; 15(7)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37050211

RESUMO

Detecting bacteria-Listeria monocytogenes-is an essential healthcare and food industry issue. The objective of the current study was to apply platinum (Pt) and screen-printed carbon (SPCE) electrodes modified by molecularly imprinted polymer (MIP) in the design of an electrochemical sensor for the detection of Listeria monocytogenes. A sequence of potential pulses was used to perform the electrochemical deposition of the non-imprinted polypyrrole (NIP-Ppy) layer and Listeria monocytogenes-imprinted polypyrrole (MIP-Ppy) layer over SPCE and Pt electrodes. The bacteria were removed by incubating Ppy-modified electrodes in different extraction solutions (sulphuric acid, acetic acid, L-lysine, and trypsin) to determine the most efficient solution for extraction and to obtain a more sensitive and repeatable design of the sensor. The performance of MIP-Ppy- and NIP-Ppy-modified electrodes was evaluated by pulsed amperometric detection (PAD). According to the results of this research, it can be assumed that the most effective MIP-Ppy/SPCE sensor can be designed by removing bacteria with the proteolytic enzyme trypsin. The LOD and LOQ of the MIP-Ppy/SPCE were 70 CFU/mL and 210 CFU/mL, respectively, with a linear range from 300 to 6700 CFU/mL.

18.
Pharmaceutics ; 15(4)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37111663

RESUMO

Gene delivery by the pulsed electric field is a promising alternative technology for nonviral transfection; however, the application of short pulses (i.e., nanosecond) is extremely limited. In this work, we aimed to show the capability to improve gene delivery using MHz frequency bursts of nanosecond pulses and characterize the potential use of gold nanoparticles (AuNPs: 9, 13, 14, and 22 nm) in this context. We have used bursts of MHz pulses 3/5/7 kV/cm × 300 ns × 100 and compared the efficacy of the parametric protocols to conventional microsecond protocols (100 µs × 8, 1 Hz) separately and in combination with nanoparticles. Furthermore, the effects of pulses and AuNPs on the generation of reactive oxygen species (ROS) were analyzed. It was shown that gene delivery using microsecond protocols could be significantly improved with AuNPs; however, the efficacy is strongly dependent on the surface charge of AuNPs and their size. The capability of local field amplification using AuNPs was also confirmed by finite element method simulation. Finally, it was shown that AuNPs are not effective with nanosecond protocols. However, MHz protocols are still competitive in the context of gene delivery, resulting in low ROS generation, preserved viability, and easier procedure to trigger comparable efficacy.

19.
Int J Mol Sci ; 24(6)2023 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-36982877

RESUMO

In this study, ZnO nanostructures with different types of morphologies and particle sizes were evaluated and applied for the development of an immunosensor. The first material was composed of spherical, polydisperse nanostructures with a particle size in the range of 10-160 nm. The second was made up of more compact rod-like spherical nanostructures with the diameter of these rods in the range of 50-400 nm, and approximately 98% of the particles were in the range of 20-70 nm. The last sample of ZnO was made up of rod-shaped particles with a diameter of 10-80 nm. These ZnO nanostructures were mixed with Nafion solution and drop-casted onto screen-printed carbon electrodes (SPCE), followed by a further immobilization of the prostate-specific antigen (PSA). The affinity interaction of PSA with monoclonal antibodies against PSA (anti-PSA) was evaluated using the differential pulse voltammetry technique. The limit of detection and limit of quantification of anti-PSA were determined as 1.35 nM and 4.08 nM for compact rod-shaped spherical ZnO nanostructures, and 2.36 nM and 7.15 nM for rod-shaped ZnO nanostructures, respectively.


Assuntos
Técnicas Biossensoriais , Óxido de Zinco , Humanos , Masculino , Anticorpos Monoclonais , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas , Eletrodos , Ouro/química , Imunoensaio/métodos , Limite de Detecção , Antígeno Prostático Específico/química , Óxido de Zinco/química , Nanopartículas Metálicas
20.
J Pharm Biomed Anal ; 228: 115343, 2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-36934618

RESUMO

The appearance of the biomarkers in body fluids like blood, urine, saliva, tears, etc. can be used for the identification of many diseases. This article aimed to summarize the studies about electrochemical biosensors with molecularly imprinted polymers as sensitive and selective layers on the electrode to detect protein-based biomarkers of such neurodegenerative diseases as Alzheimer's disease, Parkinson's disease, and stress. The main attention in this article is focused on the detection methods of amyloid-ß oligomers and p-Tau which are representative biomarkers for Alzheimer's disease, α-synuclein as the biomarker of Parkinson's disease, and α-amylase and lysozyme as the biomarkers of stress using molecular imprinting technology. The research methods, the application of different electrodes, the influence of the polymers, and the established detection limits are reviewed and compared.


Assuntos
Doença de Alzheimer , Impressão Molecular , Doenças Neurodegenerativas , Doença de Parkinson , Humanos , Polímeros Molecularmente Impressos , Doenças Neurodegenerativas/diagnóstico , Doença de Alzheimer/diagnóstico , Biomarcadores , Impressão Molecular/métodos , Eletrodos , Técnicas Eletroquímicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...