Resultados 1 - 20 de 70
Filtrar
1.
Biomed Opt Express ; 15(4): 2308-2327, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38633081

RESUMO

Pulse oximetry represents a ubiquitous clinical application of optics in modern medicine. Recent studies have raised concerns regarding the potential impact of confounders, such as variable skin pigmentation and perfusion, on blood oxygen saturation measurement accuracy in pulse oximeters. Tissue-mimicking phantom testing offers a low-cost, well-controlled solution for characterizing device performance and studying potential error sources, which may thus reduce the need for costly in vivo trials. The purpose of this study was to develop realistic phantom-based test methods for pulse oximetry. Material optical and mechanical properties were reviewed, selected, and tuned for optimal biological relevance, e.g., oxygenated tissue absorption and scattering, strength, elasticity, hardness, and other parameters representing the human finger's geometry and composition, such as blood vessel size and distribution, and perfusion. Relevant anatomical and physiological properties are summarized and implemented toward the creation of a preliminary finger phantom. To create a preliminary finger phantom, we synthesized a high-compliance silicone matrix with scatterers for embedding flexible tubing and investigated the addition of these scatterers to novel 3D printing resins for optical property control without altering mechanical stability, streamlining the production of phantoms with biologically relevant characteristics. Phantom utility was demonstrated by applying dynamic, pressure waveforms to produce tube volume change and resultant photoplethysmography (PPG) signals. 3D printed phantoms achieved more biologically relevant conditions compared to molded phantoms. These preliminary results indicate that the phantoms show strong potential to be developed into tools for evaluating pulse oximetry performance. Gaps, recommendations, and strategies are presented for continued phantom development.

2.
J Biomed Opt ; 29(5): 052918, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38282917

RESUMO

Significance: Preterm birth is defined as a birth before 37 weeks of gestation and is one of the leading contributors to infant mortality rates globally. Premature birth can lead to life-long developmental impairment for the child. Unfortunately, there is a significant lack of tools to diagnose preterm birth risk, which limits patient care and the development of new therapies. Aim: To develop a speculum-free, portable preterm imaging system (PPRIM) for cervical imaging; testing of the PPRIM system to resolve polarization properties of birefringent samples; and testing of the PPRIM under an IRB on healthy, non-pregnant volunteers for visualization and polarization analysis of cervical images. Approach: The PPRIM can perform 4×3 Mueller-matrix imaging to characterize the remodeling of the uterine cervix during pregnancy. The PPRIM is built with a polarized imaging probe and a flexible insertable sheath made with a compatible flexible rubber-like material to maximize comfort and ease of use. Results: The PPRIM device is developed to meet specific design specifications as a speculum-free, portable, and comfortable imaging system with polarized imaging capabilities. This system comprises a main imaging component and a flexible silicone inserter. The inserter is designed to maximize comfort and usability for the patient. The PPRIM shows high-resolution imaging capabilities at the 20 mm working distance and 25 mm circular field of view. The PPRIM demonstrates the ability to resolve birefringent sample orientation and full field capture of a healthy, non-pregnant cervix. Conclusion: The development of the PPRIM aims to improve access to the standard of care for women's reproductive health using polarized Mueller-matrix imaging of the cervix and reduce infant and maternal mortality rates and better quality of life.


Assuntos
Nascimento Prematuro , Gravidez , Lactente , Criança , Recém-Nascido , Feminino , Humanos , Qualidade de Vida , Colo do Útero/diagnóstico por imagem
3.
Physiol Meas ; 44(11)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-37494945

RESUMO

Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.


Assuntos
Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Monitores de Aptidão Física , Processamento de Sinais Assistido por Computador , Frequência Cardíaca/fisiologia
4.
Biosensors (Basel) ; 12(10)2022 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-36290924

RESUMO

Cervical cancer is one of the most significant global health inequities of our time and is the fourth most common cancer in women worldwide, disproportionally affecting developing countries where the disease burden is 84%. Sometimes referred to as preventable cancer, it progresses slowly, providing a window of time for routine screening in which pre-cancerous lesions can be identified and treated. The high mortality rate can be attributed to many reasons, including the high cost of cytology-based screening, lack of human resources to conduct screening, and inadequate preventive medicine services and systems. Due to its slow progression, early intervention is feasible with appropriate screening. However, the standard screening procedures require access to lab-based tests and physician expertise. Several imaging devices have been introduced in the literature to aid cervical screening in low-resource settings. This review details the instrumentation and clinical testing of devices currently deployed in low-resource locations worldwide. The devices' imaging, portability, illumination, and power requirements (among other metrics) are documented with specifics of human pilot studies conducted with these tools.


Assuntos
Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/prevenção & controle , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos
5.
J Biomed Opt ; 27(8)2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35534924

RESUMO

SIGNIFICANCE: Monte Carlo (MC) methods have been applied for studying interactions between polarized light and biological tissues, but most existing MC codes supporting polarization modeling can only simulate homogeneous or multi-layered domains, resulting in approximations when handling realistic tissue structures. AIM: Over the past decade, the speed of MC simulations has seen dramatic improvement with massively parallel computing techniques. Developing hardware-accelerated MC simulation algorithms that can accurately model polarized light inside three-dimensional (3D) heterogeneous tissues can greatly expand the utility of polarization in biophotonics applications. APPROACH: Here, we report a highly efficient polarized MC algorithm capable of modeling arbitrarily complex media defined over a voxelated domain. Each voxel of the domain can be associated with spherical scatters of various radii and densities. The Stokes vector of each simulated photon packet is updated through photon propagation, creating spatially resolved polarization measurements over the detectors or domain surface. RESULTS: We have implemented this algorithm in our widely disseminated MC simulator, Monte Carlo eXtreme (MCX). It is validated by comparing with a reference central-processing-unit-based simulator in both homogeneous and layered domains, showing excellent agreement and a 931-fold speedup. CONCLUSION: The polarization-enabled MCX offers biophotonics community an efficient tool to explore polarized light in bio-tissues, and is freely available at http://mcx.space/.


Assuntos
Fótons , Software , Algoritmos , Simulação por Computador , Luz , Método de Monte Carlo
6.
Biomed Opt Express ; 13(2): 571-589, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35284190

RESUMO

A polarization enhanced laparoscopy (PEL) imaging system was developed to examine the feasibility of utilizing PEL to augment conventional white light laparoscopy (WLL) in the visualization of peritoneal cancer metastases. The system includes a modified tip to illuminate tissue with linearly polarized light and elements in the detection path enabling recording of corresponding images linearly co- and cross-polarized relative to the incident light. WLL and PEL images from optical tissue phantoms with features of distinct scattering cross-section confirm the enhanced sensitivity of PEL to such characteristics. Additional comparisons based on images acquired from collagen gels with different levels of fiber alignment highlight another source of PEL contrast. Finally, PEL and WLL images of ex vivo human tissue illustrate the potential of PEL to improve visualization of cancerous tissue surrounded by healthy peritoneum. Given the simplicity of the approach and its potential for seamless integration with current clinical practice, our results provide motivation for clinical translation.

7.
J Biomed Opt ; 27(3)2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35352513

RESUMO

SIGNIFICANCE: Obesity is a worldwide epidemic contributing directly to several cardiovascular risk factors including hypertension and type 2 diabetes. Wearable devices are becoming better at quantifying biomarkers relevant for the management of health and fitness. Unfortunately, both anecdotal evidence and recent studies indicate that some wearables have higher levels of error when utilized by populations with darker skin tones and high body mass index (BMI). There is an urgent need for a better evaluation of the limits of wearable health technologies when used by obese individuals. AIMS: (1) To review the current know-how on changes due to obesity in the skin epidermis, dermis, and subcutis that could affect the skin optical properties; (2) for the green wavelength range, to evaluate the difference in absorption and scattering coefficients from the abdominal skin between individuals with and without elevated BMI. The changes include alterations in layer thickness and cell size, as well as significant differences in chromophores and scatterer content, e.g., water, hemoglobin, collagen, and lipids. APPROACH: We have summarized literature pertaining to changes in skin and its components in obesity and report the results of our search using articles published between years 1971 and 2020. A linear model was used to demonstrate the absorption and reduced scattering coefficient of the abdominal skin of individuals with and without elevated BMI in the green wavelength range (530 to 550 nm) that is typically found in most wearables. RESULTS: The general trends indicate a decrease in absorption for both dermis and subcutis and an increase in reduced scattering for both epidermis and dermis. At 544-nm wavelength, a typical wavelength used for photoplethysmography (PPG), the absorption coefficient's relative percentage difference between high and low BMI skin, was 49% in the subcutis, 19% in the dermis, and negligible in the epidermis, whereas the reduced scattering coefficient relative difference was 21%, 29%, and 165% respectively. CONCLUSIONS: These findings suggest that there could be significant errors in the output of optical devices used for monitoring health and fitness if changes due to obesity are not accounted for in their design.


Assuntos
Diabetes Mellitus Tipo 2 , Índice de Massa Corporal , Epiderme , Humanos , Obesidade/diagnóstico por imagem , Pele/irrigação sanguínea , Pele/diagnóstico por imagem
8.
Opt Lett ; 47(21): 5549-5552, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37219266

RESUMO

The advent of imagers with integrated linear polarization selectivity opens new opportunities for researchers interested in the polarization properties of biological tissues. In this Letter, we explore the mathematical framework necessary to obtain common parameters of interest: azimuth; retardance; and depolarization with reduced Mueller matrices that can be measured with the new instrumentation. We show that in the case of acquisition close to the tissue normal, simple algebraic analysis of the reduced form of the Mueller matrix yields results very close to those obtained with more complex decomposition algorithms applied to a complete Mueller matrix.

9.
Sci Rep ; 11(1): 15621, 2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-34341418

RESUMO

Preterm birth risk is associated with early softening of the uterine cervix in pregnancy due to the accelerated remodeling of collagen extracellular matrix. Studies of mice model of pregnancy were performed with an imaging Mueller polarimeter at different time points of pregnancy to find polarimetric parameters for collagen scoring. Mueller matrix images of the unstained sections of mice uterine cervices were taken at day 6 and day 18 of 19-days gestation period and at different spatial locations through the cervices. The logarithmic decomposition of the recorded Mueller matrices mapped the depolarization, linear retardance, and azimuth of the optical axis of cervical tissue. These images highlighted both the inner structure of cervix and the arrangement of cervical collagen fibers confirmed by the second harmonic generation microscopy. The statistical analysis and two-Gaussians fit of the distributions of linear retardance and linear depolarization in the entire images of cervical tissue (without manual selection of the specific regions of interest) quantified the randomization of collagen fibers alignment with gestation time. At day 18 the remodeling of cervical extracellular matrix of collagen was measurable at the external cervical os that is available for the direct optical observations in vivo. It supports the assumption that imaging Mueller polarimetry holds promise for the fast and accurate collagen scoring in pregnancy and the assessment of the preterm birth risk.


Assuntos
Nascimento Prematuro , Animais , Anisotropia , Colo do Útero , Colágeno , Diagnóstico por Imagem , Feminino , Camundongos , Gravidez
10.
J Biomed Opt ; 26(6)2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34189875

RESUMO

Guest editors Jessica Ramella-Roman, Amir H. Gandjbakhche, Stephen C. Kanick, Babak Shadgan, and Bruce J. Tromberg introduce and summarize the articles included in the 6-part JBO Special Section on Wearable, Implantable, Mobile, and Remote Biomedical Optics Photonics.


Assuntos
Óptica e Fotônica , Dispositivos Eletrônicos Vestíveis , Técnicas Histológicas , Próteses e Implantes
11.
Biomed Opt Express ; 12(4): 2236-2249, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33996226

RESUMO

We propose an approach for discriminating fibrillar collagen fibers from elastic fibers in the mouse cervix in Mueller matrix microscopy using convolutional neural networks (CNN) and K-nearest neighbor (K-NN) for classification. Second harmonic generation (SHG), two-photon excitation fluorescence (TPEF), and Mueller matrix polarimetry images of the mice cervix were collected with a self-validating Mueller matrix micro-mesoscope (SAMMM) system. The components and decompositions of each Mueller matrix were arranged as individual channels of information, forming one 3-D voxel per cervical slice. The classification algorithms analyzed each voxel and determined the amount of collagen and elastin, pixel by pixel, on each slice. SHG and TPEF were used as ground truths. To assess the accuracy of the results, mean-square error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) were used. Although the training and testing is limited to 11 and 5 cervical slices, respectively, MSE accuracy was above 85%, SNR was greater than 40 dB, and SSIM was larger than 90%.

12.
Biosensors (Basel) ; 11(4)2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33923469

RESUMO

Photoplethysmography (PPG) is a low-cost, noninvasive optical technique that uses change in light transmission with changes in blood volume within tissue to provide information for cardiovascular health and fitness. As remote health and wearable medical devices become more prevalent, PPG devices are being developed as part of wearable systems to monitor parameters such as heart rate (HR) that do not require complex analysis of the PPG waveform. However, complex analyses of the PPG waveform yield valuable clinical information, such as: blood pressure, respiratory information, sympathetic nervous system activity, and heart rate variability. Systems aiming to derive such complex parameters do not always account for realistic sources of noise, as testing is performed within controlled parameter spaces. A wearable monitoring tool to be used beyond fitness and heart rate must account for noise sources originating from individual patient variations (e.g., skin tone, obesity, age, and gender), physiology (e.g., respiration, venous pulsation, body site of measurement, and body temperature), and external perturbations of the device itself (e.g., motion artifact, ambient light, and applied pressure to the skin). Here, we present a comprehensive review of the literature that aims to summarize these noise sources for future PPG device development for use in health monitoring.


Assuntos
Frequência Cardíaca/fisiologia , Monitorização Fisiológica , Fotopletismografia , Artefatos , Pressão Sanguínea , Humanos , Respiração , Processamento de Sinais Assistido por Computador , Dispositivos Eletrônicos Vestíveis
13.
Sci Rep ; 11(1): 2570, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33510428

RESUMO

Cardiovascular disease is one of the leading causes of death in the United States and obesity significantly increases the risk of cardiovascular disease. The measurement of blood pressure (BP) is critical in monitoring and managing cardiovascular disease hence new wearable devices are being developed to make BP more accessible to physicians and patients. Several wearables utilize photoplethysmography from the wrist vasculature to derive BP assessment although many of these devices are still at the experimental stage. With the ultimate goal of supporting instrument development, we have developed a model of the photoplethysmographic waveform derived from the radial artery at the volar surface of the wrist. To do so we have utilized the relation between vessel biomechanics through Finite Element Method and Monte Carlo light transport model. The model shows similar features to that seen in PPG waveform captured using an off the shelf device. We observe the influence of body mass index on the PPG signal. A degradation the PPG signal of up to 40% in AC to DC signal ratio was thus observed.


Assuntos
Fotopletismografia/métodos , Artéria Radial/fisiologia , Animais , Fenômenos Biomecânicos , Pressão Sanguínea/fisiologia , Índice de Massa Corporal , Análise de Elementos Finitos , Humanos , Método de Monte Carlo
14.
Biomed Opt Express ; 12(12): 7445-7457, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35003845

RESUMO

Commercially available wearable devices have been used for fitness and health management and their demand has increased over the last ten years. These "general wellness" and heart-rate monitoring devices have been cleared by the Food and Drug Administration for over-the-counter use, yet anecdotal and more systematic reports seem to indicate that their error is higher when used by individuals with elevated skin tone and high body mass index (BMI). In this work, we used Monte Carlo modeling of a photoplethysmography (PPG) signal to study the theoretical limits of three different wearable devices (Apple Watch series 5, Fitbit Versa 2 and Polar M600) when used by individuals with a BMI range of 20 to 45 and a Fitzpatrick skin scale 1 to 6. Our work shows that increased BMI and skin tone can induce a relative loss of signal of up to 61.2% in Fitbit versa 2, 32% in Apple S5 and 32.9% in Polar M600 when considering the closest source-detector pair configuration in these devices.

15.
J Biomed Opt ; 25(11)2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33191686

RESUMO

SIGNIFICANCE: Mueller matrix polarimetry can provide useful information about the function and structure of the extracellular matrix. A portable and low-cost system could facilitate the clinical assessment of cervical anomalies in low-resource settings. AIM: We introduce a low-cost snapshot Mueller matrix polarimeter that does not require external power, has no moving parts, and can acquire a full Mueller matrix in ∼1 s, to conduct a feasibility study for cervical imaging in the low-resource setting. APPROACH: A snapshot system based on two sets of Savart plates, a ring illuminator with polarizing elements (generating four polarization states), and one camera is introduced. Stokes vectors are formulated to recover the polarization properties of the sample. Then, using Mueller matrix decomposition, the depolarization and retardance information is extracted. RESULTS: We report the results on 16 healthy individuals (out of 22 patients imaged), whose Pap smear showed no malignant findings from mobile clinics in rural region of Mysore, India. The depolarization and retardance information was in agreement with previous reports. CONCLUSIONS: We introduce an imaging system and conducted a feasibility study on healthy individuals. This work could futurely translate into diagnostic applications to provide a quantitative platform in the clinical environment (e.g., cervical cancer screening).


Assuntos
Colposcópios , Neoplasias do Colo do Útero , Diagnóstico por Imagem , Detecção Precoce de Câncer , Feminino , Humanos , Análise Espectral , Neoplasias do Colo do Útero/diagnóstico por imagem
16.
Biomed Opt Express ; 11(10): 5982-5994, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33150000

RESUMO

Mueller matrix polarimetry (MMP) is a promising linear imaging modality that can enable visualization and measurement of the polarization properties of the cornea. Although the distribution of corneal birefringence has been reported, depth resolved MMP imaging of the cornea has not been archived and remains challenging. In this work, we perform depth-resolved imaging of the cornea using an improved system that combines Mueller matrix reflectance and transmission microscopy together with nonlinear microscopy utilizing second harmonic generation (SHG) and two photon excitation fluorescence (TPEF). We show that TPEF can reveal corneal epithelial cellular network while SHG can highlight the presence of corneal stromal lamellae. We then demonstrate that, in confocal reflectance measurement, as depth increases from 0 to 80 µm both corneal depolarization and retardation increase. Furthermore, it is shown that the spatial distribution of corneal depolarization and retardation displays similar complexity in both reflectance (confocal and non-confocal) and transmission measurement, likely due to the strong degree of heterogeneity in the stromal lamellae.

17.
Artigo em Inglês | MEDLINE | ID: mdl-32426338

RESUMO

The emerging field of theranostics for advanced healthcare has raised the demand for effective and safe delivery systems consisting of therapeutics and diagnostics agents in a single monarchy. This requires the development of multi-functional bio-polymeric systems for efficient image-guided therapeutics. This study reports the development of size-controlled (micro-to-nano) auto-fluorescent biopolymeric hydrogel particles of chitosan and hydroxyethyl cellulose (HEC) synthesized using water-in-oil emulsion polymerization technique. Sustainable resource linseed oil-based polyol is introduced as an element of hydrophobicity with an aim to facilitate their ability to traverse the blood-brain barrier (BBB). These nanogels are demonstrated to have salient features such as biocompatibility, stability, high cellular uptake by a variety of host cells, and ability to transmigrate across an in vitro BBB model. Interestingly, these unique nanogel particles exhibited auto-fluorescence at a wide range of wavelengths 450-780 nm on excitation at 405 nm whereas excitation at 710 nm gives emission at 810 nm. In conclusion, this study proposes the developed bio-polymeric fluorescent micro- and nano- gels as a potential theranostic tool for central nervous system (CNS) drug delivery and image-guided therapy.

18.
J Biomech Eng ; 142(10)2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32291440

RESUMO

Understanding aortic valve (AV) mechanics is crucial in elucidating both the mechanisms that drive the manifestation of valvular diseases as well as the development of treatment modalities that target these processes. Genetically modified mouse models have become the gold standard in assessing biological mechanistic influences of AV development and disease. However, very little is known about mouse aortic valve leaflet (MAVL) tensile properties due to their microscopic size (∼500 µm long and 45 µm thick) and the lack of proper mechanical testing modalities to assess uniaxial and biaxial tensile properties of the tissue. We developed a method in which the biaxial tensile properties of MAVL tissues can be assessed by adhering the tissues to a silicone rubber membrane utilizing dopamine as an adhesive. Applying equiaxial tensile loads on the tissue-membrane composite and tracking the engineering strains on the surface of the tissue resulted in the characteristic orthotropic response of AV tissues seen in human and porcine tissues. Our data suggest that the circumferential direction is stiffer than the radial direction (n = 6, P = 0.0006) in MAVL tissues. This method can be implemented in future studies involving longitudinal mechanical stimulation of genetically modified MAVL tissues bridging the gap between cellular biological mechanisms and valve mechanics in popular mouse models of valve disease.


Assuntos
Valva Aórtica , Estresse Mecânico , Animais , Suínos
19.
Opt Lett ; 45(8): 2168-2171, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32287183

RESUMO

Reflectance Mueller matrix (MM) polarimetry is being used to characterize biological media in multiple clinical applications. The origin of the reflectance polarimetric data is often unclear due to the impact of multiple scattering and tissue heterogeneity. We have developed a new, to the best of our knowledge, multimodal imaging technique combining MM reflectance, MM digital confocal imaging, and co-registered nonlinear microscopy techniques. The instrument unveils the origin of reflectance polarimetric signature in terms of confocal reflectance data. The reconstructed reflected MM demonstrates the capability of our method to provide depth-resolved 3D polarization response from complex biological media in terms of depolarization, retardance, and orientation parameters.


Assuntos
Microscopia/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes
20.
Bioengineering (Basel) ; 6(2)2019 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-31067726

RESUMO

The progression of calcific aortic valve disease (CAVD) is characterized by extracellular matrix (ECM) remodeling, leading to structural abnormalities and improper valve function. The focus of the present study was to relate aortic valve leaflet axial curvature changes as a function of elastin degradation, which has been associated with CAVD. Circumferential rectangular strips (L × W = 10 × 2.5 mm) of normal and elastin-degraded (via enzymatic digestion) porcine AV leaflets were subjected to cyclic flexure (1 Hz). A significant increase in mean curvature (p < 0.05) was found in elastin-degraded leaflet specimens in comparison to un-degraded controls at both the semi-constrained (50% of maximum flexed state during specimen bending and straightening events) and fully-constrained (maximally-flexed) states. This significance did not occur in all three flexed configurations when measurements were performed using either minimum or maximum curvature. Moreover, the mean curvature increase in the elastin-degraded leaflets was most pronounced at the instance of maximum flexure, compared to un-degraded controls. We conclude that the mean axial curvature metric can detect distinct spatial changes in aortic valve ECM arising from the loss in bulk content and/or structure of elastin, particularly when there is a high degree of tissue bending. Therefore, the instance of maximum leaflet flexure during the cardiac cycle could be targeted for mean curvature measurements and serve as a potential biomarker for elastin degradation in early CAVD remodeling.