Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Curr Oncol ; 24(4): e333-e336, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28874904

RESUMO

Hepatocellular carcinoma (hcc) arising from a hepatic adenoma is a rare phenomenon accounting for fewer than 5% of hcc cases; it seldom recurs after resection of the primary tumour. We report a case of extrahepatic metastasis of hcc arising from a hepatic adenoma that presented as a solitary sternal metastasis without any evidence of intrahepatic recurrence. Our patient was initially treated with radiation therapy and bland embolization, without response. Subsequently, the patient developed progressive disease while taking sorafenib. He later received chemotherapy with docetaxel and gemcitabine, with the development of multiple pulmonary and splenic nodules. However, he remained free of intrahepatic recurrence. To the best of our knowledge, this is the first case of extrahepatic metastasis of hcc arising from a hepatic adenoma without evidence of intrahepatic recurrence.

4.
Clin Rehabil ; 12(6): 497-505, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9869253

RESUMO

OBJECTIVE: To compare the reliability of measurements of hip motions obtained with two instruments, an electronic inclinometer and a two-arm goniometer, and to investigate whether the two instruments, and different body positions, produce the same measurement data. METHODS: Maximal active and passive hip movements were measured simultaneously with both instruments, in nine subjects during 10 consecutive measurements at short intervals. RESULTS: Intra-observer variability was lower with the inclinometer in measurements of passive hip rotations. The two instruments showed equal intra-observer variability for hip movements in general. The inclinometer showed lower inter-observer variability in the measurements of active internal rotation. More rotational movement was measured with the two-arm goniometer; more extension and flexion with the inclinometer. Also, more rotational movement was found in the prone position compared to sitting and supine positions. CONCLUSIONS: The inclinometer is more reliable in measurements of hip rotation. For hip movements in general the two-arm goniometer is just as accurate when used by only one observer. The two instruments, and some positions, are not interchangeable during consecutive measurements.


Assuntos
Articulação do Quadril/fisiologia , Amplitude de Movimento Articular/fisiologia , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...