Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(11)2021 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-34067327

RESUMO

The objective of this study was to evaluate the performance of the different systems and techniques aimed at suppressing vibrations on optical ground-based telescopes. We identified the studies by searching three electronic databases (Science Direct, IEEE library and Web of Science) from the year 2000 to December 2020. The studies were eligible if they proposed systems focused on mitigating the effects of vibrations in optical telescopes and brought performance data. A total of nine studies met our eligibility criteria. Current evidence confirms the feasibility of adaptative optics (AO) systems based on closed-loop control to mitigate vibrations, although variations and additions should be made depending on their nature and characteristics in order to improve the performance of the proposed techniques. This systematic review was conducted to provide a state-of-the-art of the methods and techniques that have been developed over the past two decades. The review also points out some issues that demand future research.

2.
Sensors (Basel) ; 20(22)2020 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-33203077

RESUMO

The location of large telescopes, generally far from the data processing centers, represents a logistical problem for the supervision of the capture of images. In this work, we carried out a preliminary study of the vibration signature of the T80 telescope at the Javalambre Astrophysical Observatory (JAO). The study analyzed the process of calculating the displacement that occurs because of the vibration in each of the frequencies in the range of interest. We analyzed the problems associated with very low frequencies by means of simulation, finding the most critical vibrations below 20 Hz, since they are the ones that generate greater displacements. The work also relates previous studies based on simulation with the real measurements of the vibration of the telescope taken remotely when it is subjected to different positioning movements (right ascension and/or declination) or when it performs movement actions such as those related to filter trays or mirror cover. The obtained results allow us to design a remote alarm system to detect invalid images (taken with excess vibration).

3.
J Med Syst ; 39(9): 103, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26265237

RESUMO

This work brings together the emerging virtual reality techniques and the natural user interfaces to offer new possibilities in the field of rehabilitation. We have designed a rehabilitation game based on a low cost device (Microsoft Kinect(TM)) connected to a personal computer. It provides patients having Parkinson's Disease (PD) with a motivating way to perform several motor rehabilitation exercises to improve their rehabilitation. The experiment was tested on seven Parkinson's Disease patients and results demonstrated significant improvements in completion time score and in the 10 Meters Walk Test score. Nevertheless, additional research is needed to determine if this type of training has a long-term impact. Both the device and protocol were well accepted by subjects, being safe and easy to use. We conclude that our work provides a simple and suitable tool resulting in a more enriching rehabilitation process where motivation is highly encouraged in PD patients. Feedback coming from participants corroborate the hypothesis that the system can be applied not only in clinical rehabilitation centers but at home.


Assuntos
Terapia por Exercício/métodos , Extremidade Inferior/fisiologia , Doença de Parkinson/reabilitação , Jogos de Vídeo , Idoso , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Equilíbrio Postural , Fatores de Tempo , Interface Usuário-Computador , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA