Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Sci Pollut Res Int ; 30(21): 60036-60049, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37017840

RESUMO

This study investigates spatio-temporal variations of PM10 mass concentrations and associated metal(oid)s, δ13C carbon isotope ratios, polycyclic aromatic hydrocarbons (PAHs), total organic carbon (TOC) and equivalent black carbon (eBC) concentrations over a half year period (from March 2017 to October 2017) in two residential areas of Medellín (MED-1 and MED-2) and Itagüí municipality (ITA-1 and ITA-2) at a tropical narrow valley (Aburrá Valley, Colombia), where few data are available. A total of 104 samples were analysed by using validated analytical methodologies, providing valuable data for PM10 chemical characterisation. Metal(oid)s concentrations were measured by inductively coupled plasma mass spectrometry (ICP-MS) after acid digestion, and PAHs concentrations were measured by Gas Chromatography-Mass Spectrometry (GC-MS) after Pressurised Hot Water Extraction (PHWE) and Membrane Assisted Solvent Extraction (MASE). Mean PM10 mass concentration ranged from 37.0 µg m-3 to 45.7 µg m-3 in ITA-2 and MED-2 sites, respectively. Al, Ca, Mg and Na (from 6249 ng m-3 for Mg at MED-1 site to 10,506 ng m-3 for Ca at MED-2 site) were the major elements in PM10 samples, whilst As, Be, Bi, Co, Cs, Li, Ni, Sb, Se, Tl and V were found at trace levels (< 5.4 ng m-3). Benzo[g,h,i] perylene (BghiP), benzo[b + j]fluoranthene (BbjF) and indene(1,2,3-c,d)pyrene (IcdP) were the most profuse PAHs in PM10 samples, with average concentrations of 0.82-0.86, 0.60-0.78 and 0.47-0.58 ng m-3, respectively. Results observed in the four sampling sites showed a similar dispersion pattern of pollutants, with temporal fluctuations which seems to be associated to the meteorology of the valley. A PM source apportionment study were carried out by using the positive matrix factorization (PMF) model, pointing to re-suspended dust, combustion processes, quarry activity and secondary aerosols as PM10 sources in the study area. Among them, combustion was the major PM10 contribution (accounting from 32.1 to 32.9% in ITA-1 and ITA-2, respectively), followed by secondary aerosols (accounting for 13.2% and 23.3% ITA-1 and MED-1, respectively). Finally, a moderate carcinogenic risk was observed for PM10-bound PAHs exposure via inhalation, whereas significant carcinogenic risk was estimated for carcinogenic metal(oid)s exposure in the area during the sampling period.


Assuntos
Poluição do Ar , Exposição Ambiental , Material Particulado , Poluentes Atmosféricos/análise , Carbono/análise , Colômbia , Monitoramento Ambiental/métodos , Material Particulado/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Medição de Risco , Poluição do Ar/estatística & dados numéricos , Exposição Ambiental/estatística & dados numéricos , Humanos
2.
Ecotoxicol Environ Saf ; 245: 114090, 2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-36162350

RESUMO

Air pollution includes polycyclic aromatic hydrocarbons (PAHs), which have been correlated to endocrine disruptor pathways during early pregnancy. PAHs have been found in the placenta and cord blood, which may affect the hormones involved in placental development. We studied the effects of some airborne PAHs on beta human chorionic gonadotropin (ß-hCG) and progesterone production by using a syncytial BeWo cell line as a placental model. PAH congeners were spiked in silicon rubber membrane (SRMs) and were then introduced into the cell medium by the passive dosing method to reach a freely dissolved concentration for BeWo cell exposure. Ultrahigh-performance liquid chromatography coupled with a diode array detector was used to analyze the PAHs, and electrochemiluminescence was used to test the hormone levels. Our results showed that passive dosing can deliver low levels of PAH congeners in the cell medium, which allowed us to calculate the individual release constants at equilibrium and to estimate their effects. Benzo[a]pyrene was released quickly from the SRMs to the cell medium, which can be attributed to its lipophilic properties. The PAHs were shown to decrease the ß-hCG level in the short term and progesterone level in the long term, so they may serve as a pathway for endocrine disorder in trophoblastic cells. This approximation may explain observations of impaired endometrium receptivity and placental dysfunction, which enhance adverse pregnancy outcomes such as embryonic mortality and intrauterine growth restriction.


Assuntos
Disruptores Endócrinos , Hidrocarbonetos Policíclicos Aromáticos , Benzo(a)pireno/análise , Linhagem Celular , Gonadotropina Coriônica/análise , Gonadotropina Coriônica/metabolismo , Gonadotropina Coriônica/farmacologia , Disruptores Endócrinos/análise , Feminino , Humanos , Técnicas In Vitro , Placenta/metabolismo , Hidrocarbonetos Policíclicos Aromáticos/análise , Gravidez , Progesterona/metabolismo , Borracha , Silício/farmacologia
3.
J Chromatogr A ; 1606: 460381, 2019 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-31395358

RESUMO

A green analytical methodology for the determination of 16 priority polycyclic aromatic hydrocarbons (PAHs) and 8 related compounds in air particulate matter was developed and validated. The method was based on pressurized hot water extraction (PHWE) followed by miniaturized membrane-assisted solvent extraction (MASE) and programmed temperature vaporization-gas chromatography-ion trap tandem mass spectrometry detection (PTV-GC-MS/MS). The parameters studied for PHWE were percentage of organic modifier (25% MeOH), temperature (200 °C) and static extraction time (5 min). For MASE, extraction temperature (30 °C), time (90 min) and effect of an organic modifier were also optimized. The matrix effect was evaluated and compensated using deuterated labelled standards as surrogates for the quantitation of the target compounds. The analytical performance of the method was satisfactory: relative recoveries varied between 78 and 118% and repeatability and intermediate precision were <22% for all compounds. The Method Quantitation Limits (MQL) ranged from 0.9 (TPY) to 75.6 pg m-3 (NAP). Satisfactory results for accuracy and traceability were evidenced by the analysis of a reference material (SRM 1649b) and comparison with previously published methods. The greenness score was estimated and compared with other techniques widely used for the analysis of PAHs in particulate matter, having a lower relative environmental impact.


Assuntos
Atmosfera/química , Membranas Artificiais , Material Particulado/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Microextração em Fase Sólida/métodos , Água/química , Temperatura Alta , Pressão , Padrões de Referência , Reprodutibilidade dos Testes , Solventes , Espectrometria de Massas em Tandem/métodos , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...