RESUMO
PURPOSE: Results of a study to quantify rates of identification of expired medications in automated dispensing cabinets (ADCs) are reported. METHODS: A pre-post analysis was conducted to determine the effect of various types of ADC audits on rates of finding expired medications in ADCs. For the experimental phase of the study, 4 ADCs at the main campus of an academic medical center were randomly assigned to receive one of 4 interventions: (1) monthly audits of all ADC pockets, (2) monthly audits of matrix (open pocket) drawers only, (3) monthly audits of unassigned pockets only, and (4) no additional intervention. RESULTS: At baseline, rates of finding expired medication doses in the 4 ADCs ranged from 0.4% to 0.7%. During the 3-month experimental period, rates of finding expired medication doses ranged from 0.1% to 0.3%. During a final audit 1 month later, the ADC targeted for monthly audits of all pockets was found to contain no expired doses, with an overall improvement in expired-dose rates for all audited ADCs observed over the course of the 4-month study. The average time to perform a full audit for an ADC with about 340 pockets was 1 hour, or 15 seconds per pocket. The average time to perform matrix drawer-only audits averaged around 45 minutes, or 11 seconds per pocket. The average time to perform audits of unassigned matrix drawers averaged 30 minutes, or 10 seconds per pocket. CONCLUSION: Auditing of all ADC pockets on a monthly basis appears to be an effective method of reducing the rate of identification of expired medications in ADC pockets.