Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Allergy Clin Immunol Pract ; 9(4): 1570-1577, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33186764

RESUMO

BACKGROUND: We previously reported that deaerated breath condensate pH (dEBC pH) can identify preschool children with recurrent wheezing at high asthma risk. OBJECTIVE: To assess the ability of preschool dEBC pH to predict asthma risk at school age. METHODS: Children of the baseline cohort were recontacted for follow-up. Asthma diagnosis at school age was evaluated according to Global Initiative for Asthma recommendations in 135 children who at baseline had been classified into the following groups: (asymptomatic) atopic wheezers (n = 30), (asymptomatic) nonatopic wheezers (n = 57), allergic rhinitis only (n = 14), and healthy controls (n = 34). RESULTS: All (100%) former atopic wheezers, 12 (21%) of nonatopic wheezers, 2 (14%) of allergic rhinitis group, and 1 (3%) of healthy controls had developed asthma at follow-up. Among all children with baseline wheezing, baseline dEBC pH predicted asthma at follow-up with an area under the receiver operating characteristic curve (AUC) of 0.72 (sensitivity, 0.67; specificity, 0.76; at pH 7.83). Combining pH and Capacity class (CAP) led to substantial gain in sensitivity (0.96) and negative predictive value (NPV, 0.94). Additional clinical information (Asthma Predictive Index, family atopy, family asthma, and inhaled corticosteroids) further increased the potential to predict asthma (AUC, 0.94) and raised sensitivity (0.98) and NPV (0.97) to nearly perfect values. CONCLUSION: Our findings suggest (1) that dEBC pH combined with CAP class may serve as highly sensitive, noninvasive marker for the early detection of young asymptomatic preschool children with increased asthma risk, and (2) the need for additional biomarkers with high specificity to optimize early risk stratification in this clinically challenging scenario.


Assuntos
Asma , Testes Respiratórios , Asma/diagnóstico , Asma/epidemiologia , Pré-Escolar , Humanos , Concentração de Íons de Hidrogênio , Sons Respiratórios/diagnóstico , Instituições Acadêmicas
2.
Artigo em Inglês | MEDLINE | ID: mdl-32269989

RESUMO

One of the most common hereditary craniofacial anomalies in humans are cleft lip and cleft alveolar bone with or without cleft palate. Current clinical practice, the augmentation of the persisting alveolar bone defect by using autologous bone grafts, has considerable disadvantages motivating to an intensive search for alternatives. We developed a novel therapy concept based on 3D printing of biodegradable calcium phosphate-based materials and integration of osteogenic cells allowing fabrication of patient-specific, tissue-engineered bone grafts. Objective of the present study was the in vivo evaluation of implants in a rat alveolar cleft model. Scaffolds were designed according to the defect's geometry with two different pore designs (60° and 30° rotated layer orientation) and produced by extrusion-based 3D plotting of a pasty calcium phosphate cement. The scaffolds filled into the artificial bone defect in the palate of adult Lewis rats, showing a good support. Half of the scaffolds were colonized with rat mesenchymal stromal cells (rMSC) prior to implantation. After 6 and 12 weeks, remaining defect width and bone formation were quantified histologically and by microCT. The results revealed excellent osteoconductive properties of the scaffolds, a significant influence of the pore geometry (60° > 30°), but no enhanced defect healing by pre-colonization with rMSC.

3.
J Hand Surg Eur Vol ; 45(4): 408-413, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31930922

RESUMO

We recruited 25 patients after complete wrist denervation and 60 healthy adults to investigate conscious and unconscious proprioception of the wrist. Ipsi- and contralateral joint-position sense, force sense, and wrist reflexes were measured. The latter were triggered by a trapdoor, recording electromyographic signals from the extensor carpi radialis brevis, extensor carpi ulnaris, flexor carpi radialis, and flexor carpi ulnaris muscles. No significant differences were found for joint position sense, force sense, and wrist reflexes between both groups, except for reflex time of the flexor carpi ulnaris after denervation of the left wrist as compared with the left flexor carpi ulnaris in controls or in right operated wrists. At a mean follow-up of 32 months (range 8 to 133), we found no proprioceptive deficit of the conscious proprioceptive qualities of joint position sense, force sense, and the unconscious proprioceptive neuromuscular control of wrist reflex time for most muscles after complete wrist denervation. We conclude from this study that complete wrist denervation does not affect the proprioceptive senses of joint position, force sense, and reflex time of the wrist.


Assuntos
Propriocepção , Tendões , Articulação do Punho , Adulto , Humanos , Músculo Esquelético , Punho , Articulação do Punho/inervação
4.
Clin Immunol ; 211: 108327, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31863906

RESUMO

Non-infectious uveitis is associated with visual impairment and blindness. Non-biologic treatment for non-infectious uveitis is not based on strong evidence. A retrospective chart review was conducted to investigate treatment response to high-dose intravenous methylprednisolone (IVMP) in children with non-infectious uveitis. Fifty-six patients (93 eyes affected) were included. In 29% uveitis was associated with juvenile idiopathic arthritis. Uveitis predominately affected the anterior segment, was bilateral and recurrent. Complications were common and included visual loss, synechiae, cataract and/or retinal lesions. Patients received up to 5 IVMP at monthly intervals. Visual acuity improved at 3 and 6 months. Anterior chamber cells, synechiae, keratic precipitates, papillary and/or macular edema improved at 3 months. Children treated with ≥3 IVMP (vs 1 IVMP) experienced trends towards fewer relapses, fewer cataracts and less frequently required treatment with biologic agents. High-dose IVMP induce rapid improvement in children with non-infectious uveitis. Prospective randomized trials are required to confirm results.


Assuntos
Corticosteroides/uso terapêutico , Anti-Inflamatórios/uso terapêutico , Metilprednisolona/uso terapêutico , Uveíte/tratamento farmacológico , Administração Intravenosa , Adolescente , Artrite Juvenil/tratamento farmacológico , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
5.
Int J Implant Dent ; 5(1): 23, 2019 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-31240421

RESUMO

BACKGROUND: As a growing field in dentistry, the practical education during the undergraduate curriculum in implant dentistry should be extended. Not only the theoretical background but also practical skills are crucial to place implants in patients. In order to determine the exact implant position, several positioning aids are available. In the present laboratory study, the accuracy of implant insertion using two different guiding modes in a group of inexperienced participants was assessed. METHODS: After three-dimensional planning using the data of a cone beam computed tomography of artificial mandibles, surgical templates were manufactured by thermoforming. In region 35, a sleeve for the pilot drill was used, whereas in region 45, a sleeve allowing a full-guided implant insertion was inserted. Subsequently, a total of 104 implants were placed by 52 undergraduates. Radiographical assessment of the three-dimensional accuracy was performed. Furthermore, the time required to insert the implants was recorded. Statistical analysis followed. DISCUSSION: When comparing the three-dimensional accuracy of the virtually planned to the actual inserted implant, a statistically significantly higher accuracy in three-dimensional angulation was achieved for the full-guided (3.388 ± 1.647°) compared to the pilot-drill guided mode (5.792 ± 3.290°). Furthermore, the time required to insert the implant was shorter for the full-guided template (6.23 ± 1.78 min) vs. for the pilot-drill guided (8.84 ± 2.39 min). Both differences reached a statistical significance (p < 0.001). CONCLUSION: Within the limit of this laboratory study, the results suggest that inexperienced surgeons benefit from a full-guided implant insertion. However, the clinical effects have to be discussed as the mismatch was varying in the decimillimeter range.

6.
Clin Immunol ; 208: 108232, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31252176

RESUMO

CASP1 variants result in reduced enzymatic activity of procaspase-1 and impaired IL-1ß release. Despite this, affected individuals can develop systemic autoinflammatory disease. These seemingly contradictory observations have only partially been explained by increased NF-κB activation through prolonged interaction of variant procaspase-1 with RIP2. To identify further disease underlying pathomechanisms, we established an in vitro model using shRNA-directed knock-down of procaspase-1 followed by viral transduction of human monocytes (THP-1) with plasmids encoding for wild-type procaspase-1, disease-associated CASP1 variants (p.L265S, p.R240Q) or a missense mutation in the active center of procaspase-1 (p.C285A). THP1-derived macrophages carrying CASP1 variants exhibited mutation-specific molecular alterations. We here provide in vitro evidence for abnormal pyroptosome formation (p.C285A, p.240Q, p.L265S), impaired nuclear (pro)caspase-1 localization (p.L265S), reduced pro-inflammatory cell death (p.C285A) and changes in macrophage deformability that may contribute to disease pathophysiology of patients with CASP1 variants. This offers previously unknown molecular pathomechanisms in patients with systemic autoinflammatory disease.


Assuntos
Caspase 1/genética , Doenças Hereditárias Autoinflamatórias/genética , Macrófagos/patologia , Caspase 1/metabolismo , Morte Celular/fisiologia , Linhagem Celular , Variação Genética , Doenças Hereditárias Autoinflamatórias/metabolismo , Doenças Hereditárias Autoinflamatórias/patologia , Humanos , Inflamassomos/genética , Inflamassomos/metabolismo , Macrófagos/metabolismo
7.
J Oral Maxillofac Surg ; 77(9): 1868.e1-1868.e15, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31112678

RESUMO

PURPOSE: The aim of the present study was to evaluate the biomechanical stability of osteosynthesis in mandibular condyle fractures using a newly designed rhombic 3-dimensional (3D) condylar fracture plate and compare it with that using standard two 4-hole miniplates and with that in nonfractured condyles. MATERIALS AND METHODS: Using 200 porcine mandibles, 3 different monocortical plating techniques were evaluated. The condyles were fractured along a defined line tangentially through the sigmoid notch and perpendicular to the posterior border. After anatomic reduction, osteosynthesis was performed using either standard rhombic 3D condylar fracture plates and standard screws (group A) or locking rhombic 3D condylar fracture plates, which were fixed either with standard screws (group B) or locking screws (group C). For comparison, nonfractured condyles (group D) and condyles fixed with standard two 4-hole miniplates and 8 screws (group E) were included. Using a universal mechanical testing machine (TIRA Test 2720; TIRA GmbH Schalkau, Germany), each group was subjected to linear loading from laterally to medially, medially to laterally, anteriorly to posteriorly, and posteriorly to anteriorly. The maximum axial force and displacement at the maximum force were measured. The mean values were compared for statistical significance using analysis of variance with Bonferroni's correction (statistical significance set at P < .05). RESULTS: The main mode of failure in the plating techniques investigated was the pull out of screws from the proximal fragment. We found no statistically significant differences in the stability of osteosynthesis between the two 4-hole miniplates and the rhombic 3D condylar fracture plate when loading from posteriorly to anteriorly, laterally to medially, and medially to laterally. However, when loading from anteriorly to posteriorly, a statistically significant difference between the standard and locking system and the two 4-hole miniplate system was observed, with the latter proving more stable. CONCLUSIONS: The results of the present biomechanical study suggest that the rhombic 3D condylar fracture plates are suitable for the treatment of condylar neck fractures. Both types of the plate are able to resist physiologic strains comparable to the two 4-hole miniplates.


Assuntos
Fixação Interna de Fraturas , Côndilo Mandibular , Fraturas Mandibulares , Animais , Fenômenos Biomecânicos , Placas Ósseas , Alemanha , Côndilo Mandibular/lesões , Fraturas Mandibulares/cirurgia , Suínos
8.
J Prosthodont ; 28(1): e319-e324, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29527778

RESUMO

PURPOSE: The aging of zirconia ceramics (Y-TZP) is associated with tetragonal to monoclinic phase transformation. This change in microstructure may affect the optical properties of the ceramic. This study examines the effect of aging on the translucency of different zirconia materials. MATERIALS AND METHODS: 120 disc-shaped specimens were fabricated from four zirconia materials: Cercon ht white, BruxZir Solid Zirconia, Zenostar T0, Lava Plus (n = 30 per group). Accelerated aging was performed in a steam autoclave (134°C, 0.2 MPa, 5 hours). CIELab coordinates (L*, a*, b*) and luminous reflectance (Y) were measured with a spectrophotometer before and after aging. Contrast ratio (CR) and translucency parameter (TP) were calculated from the L*, a*, b*, and Y tristimulus values. The general linear model (Bonferroni adjusted) was used to compare both parameters before and after aging, as well as between the different zirconia materials (p ≤ 0.05). RESULTS: CR and TP differed significantly before and after aging in all groups tested. Before aging, Zenostar T showed the highest and Lava Plus showed the lowest translucency. After aging, Cercon ht and Zenostar T showed the highest and BruxZir and Lava Plus the lowest translucency. CONCLUSIONS: Aging reduced the translucency in all specimens tested. Furthermore, translucency differed between the zirconia brands tested. Nevertheless, the differences were below the detectability threshold of the human eye. The aging process can influence the translucency and thus the esthetic outcome of zirconia restorations; however, the changes in translucency were minimal and probably undetectable by the human eye.


Assuntos
Cerâmica , Materiais Dentários , Zircônio , Cerâmica/química , Materiais Dentários/química , Luz , Espectrofotometria , Zircônio/química
9.
Clin Oral Investig ; 23(4): 1823-1828, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30209575

RESUMO

OBJECTIVES: Posterior metal ceramic crowns are still widely used as a standard treatment. The aim of this study was to obtain long-term data on their clinical performance. MATERIAL AND METHODS: Ten private practitioners participated in this prospective practice-based study. Patients were provided with two crowns each. Two groups were formed. The single crown group comprised 95 patients with 190 crowns. The retainer crown group comprised 138 patients with fixed dental prostheses and 276 retainer crowns. RESULTS: For the primary outcome "loss of tooth or crown," 20-year survival rates of 78.8% in the single crown group and 67.8% in the retainer crown group were found. Veneering ceramic defects occurred rather frequently, resulting in respective 20-year technical success rates of 74.2% for single crowns and 62.9% for retainer crowns. However, veneering ceramic defects causing crown losses were very rare events. CONCLUSIONS: The results contribute to our knowledge on long-term outcomes of treatments with metal ceramic crowns and show high survival and success rates over 20 years. CLINICAL RELEVANCE: Posterior metal ceramic crowns are a highly reliable option in private practice settings.


Assuntos
Coroas , Falha de Restauração Dentária , Ligas Metalo-Cerâmicas , Adolescente , Adulto , Idoso , Cerâmica , Porcelana Dentária , Planejamento de Prótese Dentária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prática Privada , Estudos Prospectivos , Adulto Jovem
10.
Dent J (Basel) ; 6(3)2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30200450

RESUMO

Implant dentistry is a growing field in the education of undergraduate dental students. The present laboratory study evaluates factors which may potentially influence the accuracy of free-hand implant insertion and the use of an orientation template. After three-dimensional planning using coDiagnostiXTM, orientation templates, including sleeves for the pilot-drill in regions 41 and 45, were manufactured by thermoforming. Sixty-one fifth year dental students inserted one implant using the orientation template and another implant free-hand in an artificial mandible. Information regarding age, sex, handedness, education, and the time required for implant insertion were recorded. Subsequently, the mandibles were scanned using cone-beam-computed tomography and the accuracy of the implant position was assessed, while statistical analysis followed. The free-hand implant insertion resulted in a distal deviation of -1.34 ± 5.15° and a mesial mismatch of 0.06 ± 0.79 mm at the artificial bone level compared to the sleeves. When using the orientation templates, the deviation decreased to -0.67 ± 3.48° and a distal mismatch of -0.22 ± 0.62 mm was achieved. The difference was statistically significant for the mismatch (p < 0.049). Regarding the limitations of our study, it could be said that the accuracy level achieved by dental undergraduates using implant placement with orientation templates is comparable to that in other studies.

11.
J Sports Sci ; 36(6): 605-612, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28531363

RESUMO

Bubble formation during scuba diving might induce decompression sickness. This prospective randomised and double-blind study included 108 advanced recreational divers (38 females). Fifty-four pairs of divers, 1 breathing air and the other breathing nitrox28 undertook a standardised dive (24 ± 1 msw; 62 ± 5min) in the Red Sea. Venous gas bubbles were counted (Doppler) 30-<45 min (early) and 45-60 min (late) post-dive at jugular, subclavian and femoral sites. Only 7% (air) vs. 11% (air28®) (n.s.) were bubble-free after a dive. Independent of sampling time and breathing gas, there were more bubbles in the jugular than in the femoral vein. More bubbles were counted in the air-group than in the air28-group (pooled vein: early: 1845 vs. 948; P = 0.047, late: 1817 vs. 953; P = 0.088). The number of bubbles was sex-dependent. Lastly, 29% of female air divers but only 14% of male divers were bubble-free (P = 0.058). Air28® helps to reduce venous gas emboli in recreational divers. The bubble number depended on the breathing gas, sampling site and sex. Thus, both exact reporting the dive and in particular standardising sampling characteristics seem mandatory to compare results from different studies to further investigate the hitherto incoherent relation between inert gas bubbles and DCS.


Assuntos
Doença da Descompressão/prevenção & controle , Mergulho/fisiologia , Nitrogênio/administração & dosagem , Oxigênio/administração & dosagem , Adulto , Método Duplo-Cego , Embolia Aérea , Feminino , Veia Femoral/diagnóstico por imagem , Humanos , Veias Jugulares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores Sexuais , Veia Subclávia/diagnóstico por imagem , Ultrassonografia Doppler
12.
Front Pediatr ; 5: 256, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29250517

RESUMO

OBJECTIVES: Chronic recurrent multifocal osteomyelitis (CRMO), the most severe form of chronic nonbacterial osteomyelitis (CNO), is an autoinflammatory bone disorder. In the absence of diagnostic criteria or biomarkers, CNO/CRMO remains a diagnosis of exclusion. The aim of this study was to identify biomarkers for diagnosing multifocal disease (CRMO). STUDY DESIGN: Sera from 71 pediatric CRMO patients, 11 patients with osteoarticular infections, 62 patients with juvenile idiopathic arthritis (JIA), 7 patients with para-infectious or reactive arthritis, and 43 patients with acute leukemia or lymphoma, as well as 59 healthy individuals were collected. Multiplex analysis of 18 inflammation- and/or bone remodeling-associated serum proteins was performed. Statistical analysis included univariate ANOVA, discriminant analysis, univariate receiver operating characteristic (ROC) analysis, and logistic regression analyses. RESULTS: For 14 of 18 blood serum proteins, significant differences were determined between CRMO patients, at least one alternative diagnosis, or healthy controls. Multi-component discriminant analysis delivered five biomarkers (IL-6, CCL11/eotaxin, CCL5/RANTES, collagen Iα, sIL-2R) for the diagnosis of CRMO. ROC analysis allowed further reduction to a core set of 2 biomarkers (CCL11/eotaxin, IL-6) that are sufficient to discern between CRMO, healthy controls, and alternative diagnoses. CONCLUSION: Serum biomarkers CCL11/eotaxin and IL-6 differentiate between patients with CRMO, healthy controls, and alternative diagnoses (leukemia and lymphoma, osteoarticular infections, para-infectious arthritis, and JIA). Easily accessible biomarkers may aid in diagnosing CRMO. Further studies testing biomarkers in larger unrelated cohorts are warranted.

13.
PLoS One ; 12(6): e0179249, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28666026

RESUMO

One consequence of demographic change is the increasing demand for biocompatible materials for use in implants and prostheses. This is accompanied by a growing number of experimental animals because the interactions between new biomaterials and its host tissue have to be investigated. To evaluate novel materials and engineered tissues the use of non-destructive imaging modalities have been identified as a strategic priority. This provides the opportunity for studying interactions repeatedly with individual animals, along with the advantages of reduced biological variability and decreased number of laboratory animals. However, histological techniques are still the golden standard in preclinical biomaterial research. The present article demonstrates a detailed method comparison between histology and magnetic resonance imaging. This includes the presentation of their image qualities as well as the detailed statistical analysis for assessing agreement between quantitative measures. Exemplarily, the bony ingrowth of tissue engineered bone substitutes for treatment of a cleft-like maxillary bone defect has been evaluated. By using a graphical concordance analysis the mean difference between MRI results and histomorphometrical measures has been examined. The analysis revealed a slightly but significant bias in the case of the bone volume [Formula: see text] and a clearly significant deviation for the remaining defect width [Formula: see text] But the study although showed a considerable effect of the analyzed section position to the quantitative result. It could be proven, that the bias of the data sets was less originated due to the imaging modalities, but mainly on the evaluation of different slice positions. The article demonstrated that method comparisons not always need the use of an independent animal study, additionally.


Assuntos
Imageamento por Ressonância Magnética/métodos , Animais , Materiais Biocompatíveis , Substitutos Ósseos , Bovinos , Imageamento por Ressonância Magnética/normas , Masculino , Ratos , Ratos Endogâmicos Lew , Engenharia Tecidual
14.
Radiother Oncol ; 124(3): 379-385, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28739384

RESUMO

PURPOSE: This study aimed to analyze the intra-tumoral heterogeneity of γH2AX foci in tumor specimens following ex vivo radiation to evaluate the potential of γH2AX foci as predictors for radiosensitivity. MATERIAL AND METHODS: γH2AX foci were quantified in tumor specimens of 3hHNSCC tumor models with known differences in radiosensitivity after reoxygenation in culture medium (10h, 24h), single dose exposure (0Gy, 4Gy), and fixation 24h post-irradiation. Multiple, equally treated samples of the same tumor were analyzed for foci, normalized and fitted in a linear mixed-effects model. RESULTS: The ex vivo reoxygenation time had no significant effect on γH2AX foci counts. A significant intra model heterogeneity could be shown for FaDu (p=0.033) but not for SKX (p=0.167) and UT-SCC-5 (p=0.082) tumors, respectively. All tumor models showed a significant intra-tumoral heterogeneity between specimens of the same tumor (p<0.01) or among microscopic fields of a particular tumor specimen (p<0.0001). CONCLUSION: Similar results for ex vivo γH2AX foci between 10h and 24h reoxygenation time support the applicability of the assay in a clinical setting. The high intra-tumoral heterogeneity underlines the necessity of multiple analyzable samples per patient and therewith the need for an automated foci analysis.


Assuntos
Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/metabolismo , Neoplasias de Cabeça e Pescoço/radioterapia , Histonas/metabolismo , Animais , Biópsia , Carcinoma de Células Escamosas/patologia , Linhagem Celular Tumoral , Feminino , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Imuno-Histoquímica , Masculino , Camundongos , Camundongos Nus , Modelos Biológicos , Oxigênio/metabolismo , Tolerância a Radiação , Carcinoma de Células Escamosas de Cabeça e Pescoço , Ensaios Antitumorais Modelo de Xenoenxerto
15.
J Rheumatol ; 44(7): 1058-1065, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28461645

RESUMO

OBJECTIVE: The autoinflammatory bone disorder chronic nonbacterial osteomyelitis (CNO) covers a wide clinical spectrum, ranging from mild self-limited presentations to chronically active or recurrent courses, which are then referred to as chronic recurrent multifocal osteomyelitis (CRMO). Little is known about treatment options and longterm outcomes. We investigated treatment responses and outcomes in children with CNO. METHODS: A retrospective chart review was conducted in a tertiary referral center, covering 2004-2015. Disease activity was measured at 0, 3, 6, 12, and 24 months after treatment initiation, and at the last recorded visit. RESULTS: Fifty-six patients with CNO were identified; 44 had multifocal CNO. Fifty percent of patients relapsed after a median of 2.4 years, and as few as 40% remained relapse-free after 5 years. Nonsteroidal antiinflammatory drugs were used as first-line treatment in 55 patients, inducing remission after 3 months in all individuals with relapse rates of 50% after 2 years. Further treatment included corticosteroids (n = 23), tumor necrosis factor-α (TNF-α) inhibitors (n = 7), and bisphosphonates (n = 8). While 47% of patients with CNO relapsed within 1 year after corticosteroid therapy, favorable outcomes were achieved with TNF-α inhibitors or bisphosphonates (pamidronate). CONCLUSION: CNO is a chronic disease with favorable outcomes within the first year, but high relapse rates in longterm followup. Particularly, patients with CRMO with long-lasting, uncontrolled inflammation were at risk for the development of arthritis. Our findings underscore the importance of a timely diagnosis and treatment initiation. Prospective studies are warranted to establish evidence-based diagnostic and therapeutic approaches to CNO.


Assuntos
Corticosteroides/uso terapêutico , Anti-Inflamatórios não Esteroides/uso terapêutico , Difosfonatos/uso terapêutico , Osteomielite/tratamento farmacológico , Adolescente , Criança , Pré-Escolar , Humanos , Recidiva , Indução de Remissão , Estudos Retrospectivos , Resultado do Tratamento , Fator de Necrose Tumoral alfa/antagonistas & inibidores
16.
Res Sports Med ; 25(3): 345-356, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28397524

RESUMO

Backround: Nitrogen narcosis impairs cognitive function, a fact relevant during SCUBA-diving. Oxygen-enriched air (nitrox) became popular in recreational diving, while evidence of its advantages over air is limited. AIM: Compare effects of nitrox28 and air on two psychometric tests. METHODS: In this prospective, double-blind, open-water study, 108 advanced divers (38 females) were randomized to an air or a nitrox-group for a 60-min dive to 24 m salt water. Breathing gas effects on cognitive performance were assessed during the dive using a short- and long-term memory test and a number connection test. RESULTS: Nitrox28 divers made fewer mistakes only on the long-term memory test (p = 0.038). Female divers remembered more items than male divers (p < 0.001). There were no significant differences in the number connection test between the groups. CONCLUSION: Likely owing to the comparatively low N2 reduction and the conservative dive, beneficial nitrox28 effects to diver performance were moderate but could contribute to diving safety.


Assuntos
Cognição , Mergulho/fisiologia , Nitrogênio/fisiologia , Oxigênio/fisiologia , Adulto , Idoso , Método Duplo-Cego , Feminino , Humanos , Masculino , Memória , Pessoa de Meia-Idade , Estudos Prospectivos , Psicometria , Adulto Jovem
17.
Clin Oral Investig ; 21(8): 2521-2534, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28101680

RESUMO

OBJECTIVES: The clinical standard for alveolar cleft osteoplasty is augmentation with autologous bone being available in limited amounts and might be associated with donor site morbidity. The aim of the present study was the creation of tissue-engineered bone grafts and their in vivo evaluation regarding their potential to promote osteogenesis in an alveolar cleft model. MATERIALS AND METHODS: Artificial bone defects with a diameter of 3.3 mm were created surgically in the palate of 84 adult Lewis rats. Four experimental groups (n = 21) were examined: bovine hydroxyl apatite/collagen (bHA) without cells, bHA with undifferentiated mesenchymal stromal cells (MSC), bHA with osteogenically differentiated MSC. In a control group, the defect remained empty. After 6, 9 and 12 weeks, the remaining defect volume was assessed by cone beam computed tomography. Histologically, the remaining defect width and percentage of bone formation was quantified. RESULTS: After 12 weeks, the remaining defect width was 60.1% for bHA, 74.7% for bHA with undifferentiated MSC and 81.8% for bHA with osteogenically differentiated MSC. For the control group, the remaining defect width measured 46.2% which was a statistically significant difference (p < 0.001). CONCLUSIONS: The study design was suitable to evaluate tissue-engineered bone grafts prior to a clinical application. In this experimental set-up with the described maxillary defect, no promoting influence on bone formation of bone grafts containing bHA could be confirmed. CLINICAL RELEVANCE: The creation of a sufficient tissue-engineered bone graft for alveolar cleft osteoplasty could preserve patients from donor site morbidity.


Assuntos
Enxerto de Osso Alveolar/métodos , Minerais/farmacologia , Osteogênese/fisiologia , Engenharia Tecidual/métodos , Animais , Diferenciação Celular , Células Cultivadas , Tomografia Computadorizada de Feixe Cônico , Fêmur/cirurgia , Masculino , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Modelos Animais , Ratos , Ratos Endogâmicos Lew , Retalhos Cirúrgicos
18.
Front Pediatr ; 5: 280, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29312911

RESUMO

There is no consensus about the hemodynamic significance and, therefore, the need to treat a persistent ductus arteriosus in preterm newborns. Since the diagnosis of a hemodynamically significant persistent ductus arteriosus (hsPDA) is made by a summary of non-uniform echo-criteria in combination with the clinical deterioration of the preterm neonate, standardized clinical and ultrasound scoring systems are needed. The objective of this study was the development of a clinical score for the detection and follow-up of hsPDA. In this observational cohort study of 154 preterm neonates (mean gestational age 28.1 weeks), clinical signs for the development of hsPDA were recorded in a standardized score and compared to echocardiography. Analyzing the significance of single score parameters compared to the diagnosis by echocardiography, we developed a short clinical score (calculated sensitivity 84% and specificity 80%). In conclusion, this clinical diagnostic PDA score is non-invasive and quickly to implement. The continuous assessment of defined clinical parameters allows for a more precise diagnosis of hemodynamic significance of PDA and, therefore, should help to detect preterm neonates needing PDA-treatment. The score, therefore, allows a more targeted use of echocardiography in these very fragile preterm neonates.

19.
Rheumatol Int ; 36(6): 769-79, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27000045

RESUMO

Chronic recurrent multifocal osteomyelitis (CRMO), the most severe form of chronic nonbacterial osteomyelitis, is an autoinflammatory bone disorder. A timely diagnosis and treatment initiation is complicated by the absence of widely accepted diagnostic criteria and an incomplete pathophysiological understanding. The aim of this study was to determine biomarkers for the diagnosis and follow-up of CRMO. Serum of 56 CRMO patients was collected at the time of diagnosis. As controls, sera from treatment-naïve age-matched patients with Crohn's disease (N = 62) or JIA (N = 28) as well as healthy individuals (N = 62) were collected. Multiplex analysis of 25 inflammation markers was performed. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U tests, canonical discriminant analysis, and mixed model variance analysis. Mostly monocyte-derived serum proteins were detectable and differed significantly between groups: IL-1RA, IL-2R, IL-6, IL-12, eotaxin, MCP-1, MIP-1b, RANTES. Multicomponent discriminant analysis allowed for the definition of algorithms differentiating between CRMO, Crohn's disease, and healthy controls. Persistently high levels of MCP-1, IL-12, sIL-2R correlated with incomplete remission in follow-up samples from CRMO patients. Discrimination algorithms allow differentiation between patients with CRMO or Crohn's disease, and healthy individuals. IL-12, MCP-1, and sIL-2R can act as markers for treatment response. Though confirmation of our findings in larger multiethnical cohorts is warranted, they may prove valuable to differentiate between otherwise healthy individuals or Crohn's disease patients with "bone pain" and CRMO patients. The elevation of mainly monocyte-derived pro-inflammatory serum proteins supports the hypothesis of pro-inflammatory monocyte/macrophages driving inflammation in CRMO.


Assuntos
Doença de Crohn/diagnóstico , Citocinas/sangue , Mediadores da Inflamação/sangue , Osteomielite/diagnóstico , Adolescente , Algoritmos , Análise de Variância , Anti-Inflamatórios não Esteroides/uso terapêutico , Artrite Juvenil/sangue , Artrite Juvenil/diagnóstico , Biomarcadores/sangue , Estudos de Casos e Controles , Criança , Doença de Crohn/sangue , Diagnóstico Diferencial , Análise Discriminante , Feminino , Humanos , Masculino , Naproxeno/uso terapêutico , Osteomielite/sangue , Osteomielite/tratamento farmacológico , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
20.
Acta Bioeng Biomech ; 18(4): 117-125, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28133387

RESUMO

PURPOSE: To show the influence of retentive cavity, cavity wall preparation and different luting techniques on the fracture resistance of severely damaged teeth restored with adhesive core build-ups and monolithic zirconium crowns. METHODS: Extracted molars were prepared with 2 mm ferrule height and divided into eleven groups (n = 8/group). In nine groups a retentive occlusal cavity with a width and depth of 1 or 2 mm was prepared. Two control groups without a retentive cavity were made. Zirconium crowns were manufactured. 48 copings were cemented with glass-ionomer cement (Ketac Cem), the others (n = 40) with adhesive resin cement (Panavia F 2.0). Artificial ageing was carried out in the following way: n = 88, thermocycling (10,000 cycles, 6° C/60° C), n = 80 chewing simulation (1,200,000 cycles, 64 N). The samples were tested for load at first damage and fracture load with non-axial force. For statistical analysis ANCOVA with post hoc, Bonferroni-adjusted t-test were used ( p ≤ 0.05). RESULTS: No differences between the tested cements were detected. Influence of the cavity wall thickness was significant ( p = 0.001). Mostly, the samples with wall thickness of 2 mm showed better results. Both control groups (no cavity) showed results comparable to study groups with cavity. CONCLUSIONS: Retentive cavity is most likely not mandatory. However, if prepared, the cavity wall thickness is of higher importance than cavity depth. Glass-ionomer and adhesive resin cement are comparable for use with zirconia crowns.


Assuntos
Cimentação/métodos , Coroas , Cimentos Dentários/química , Retenção em Prótese Dentária/métodos , Reparação de Restauração Dentária/instrumentação , Zircônio , Reparação de Restauração Dentária/métodos , Humanos , Técnicas In Vitro , Dente Molar , Resistência à Tração , Preparo do Dente/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...