Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Cataract Refract Surg ; 48(3): 374-377, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34924518

RESUMO

Performing phacoemulsification in eyes with corneal opacities is challenging even with expert surgeons. Several techniques have been described to improve intraoperative visualization through opacified corneas. This retrospective interventional case series included 10 eyes of 10 patients with coexisting senile cataract and corneal opacity who underwent phacoemulsification with intraocular lens (IOL) implantation under slit illumination of the surgical microscope. Uneventful phacoemulsification with IOL implantation was achieved in all eyes without intraoperative complications. Slit illumination reduced the light scattering and reflection from the corneal opacity, enhanced the red reflex, and improved depth perception simultaneously in different steps of phacoemulsification. Phacoemulsification was safely performed in eyes with corneal opacity under slit illumination of the surgical microscope. It can be considered as a viable option for improving intraoperative visualization in patients with corneal opacities without additional instrumentation.


Assuntos
Catarata , Opacidade da Córnea , Facoemulsificação , Catarata/complicações , Opacidade da Córnea/complicações , Opacidade da Córnea/cirurgia , Humanos , Implante de Lente Intraocular/métodos , Iluminação , Facoemulsificação/métodos , Estudos Retrospectivos , Acuidade Visual
3.
Eur J Ophthalmol ; 29(1): 28-32, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29619847

RESUMO

PURPOSE:: To compare surface alterations between preloaded and manually loaded intraocular lens. METHODS:: Scanning electron microscope was utilized to evaluate surface alteration and deposits in four different types of intraocular lenses: preloaded hydrophobic acrylic, preloaded hydrophilic acrylic, manually loaded hydrophobic acrylic, and manually loaded hydrophilic acrylic. Six lenses with different powers (+6 D, +22 D, and +29 D) were used from each category, to represent different thickness categories of the intraocular lenses. RESULTS:: In total, 30 intraocular lenses have been evaluated in this study: 4 from the control group (2 hydrophobic and 2 hydrophilic lenses) and 12 from the preloaded intraocular lens and manually loaded groups (6 hydrophilic and 6 hydrophobic lenses with different powers). Surface deposits were found in eight hydrophobic intraocular lenses compared to a single intraocular lens with scattered deposits on the optical surface of a hydrophilic intraocular lens. In manually loaded intraocular lens group, five hydrophobic and one hydrophilic intraocular lenses showed identifiable marks on the optical surface. In the preloaded intraocular lens group, three hydrophobic intraocular lenses showed identifiable marks on the optical surface and three hydrophobic intraocular lenses showed surface wrinkling. All hydrophilic intraocular lenses revealed no identifiable marks. CONCLUSION:: Surface alterations and deposits are a common finding in both preloaded and manually loaded intraocular lenses. Water content of acrylic intraocular lenses is an important factor predisposing to these changes, and hydrophobic intraocular lenses are more vulnerable than hydrophilic lenses. The impact on the final visual outcome needs further studies.


Assuntos
Lentes Intraoculares , Microscopia Eletrônica de Varredura , Polimetil Metacrilato , Materiais Biocompatíveis , Humanos , Interações Hidrofóbicas e Hidrofílicas , Implante de Lente Intraocular/instrumentação , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...