Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Int J Comput Assist Radiol Surg ; 11(2): 189-96, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26233622

RESUMO

PURPOSE: Recent developments in interventional neuroradiology techniques, medical imaging modalities, endovascular stenting and embolization materials lead to an increasing number of patients with cerebral aneurysms and arteriovenous malformations that are eligible for endovascular treatment and have opened new perspectives for novel ways for patient treatment in general. In this paper, we describe a software tool for 3D image fusion of multi-modal acquisitions to assist endovascular treatment of cerebral malformations. The software and an autostereoscopic 3D display were implemented and tested in clinical applications in a hybrid interventional suite that is used for radio-interventional as well as neurosurgical procedures. Our hypothesis is that fusion of image data acquired prior to intervention procedures with images acquired during those procedures should allow better visualizing and navigating through complex cerebral vasculature. This should also improve workflows of neuro-interventional procedures. METHODS: Preoperative and intra-operative acquisitions of vascular images of the brain were performed and transferred to a dedicated imaging workstation to be processed with our image fusion and visualization software tool. The tool was developed as a plugin extension to the open-source DICOM viewer OsiriX and is based on a modular and scalable architecture. Several processing modules were implemented to allow spatial co-registration and fusion of preoperative and intra-operative modalities. A special extension was also implemented for interactive autostereosopic, glass-free 3D visualization of fused results. RESULTS: The software platform was validated and evaluated in nine in vivo procedures by expert users. All patient cases were related to interventional treatment of neuro-vascular diseases. The emphasis was laid on the added value of spatial co-registration and fusion of preoperative and intra-operative modalities, as well as the overall impact on workflow during the intervention. The co-registered and fused images were visualized on an autostereoscopic 3D monitor installed in hybrid interventional suite. All experiments were evaluated and scored by interventional physicians and technicians. CONCLUSIONS: Displaying 3D-4D representations of brain vascular anomalies based on multi-modal acquisitions on a 3D autostereoscopic display is beneficial for the workflow and efficiency of interventional radiologists. The implemented software tool fulfills the premise of applicability of an open-source platform for more advanced, multi-modal visualization and processing of brain vascular structures for image-guided therapeutic interventions.


Assuntos
Doenças Arteriais Cerebrais/diagnóstico , Imageamento Tridimensional , Imagem Multimodal/normas , Procedimentos Neurocirúrgicos/métodos , Software/normas , Cirurgia Assistida por Computador/métodos , Fluxo de Trabalho , Adulto , Idoso , Doenças Arteriais Cerebrais/cirurgia , Procedimentos Endovasculares , Feminino , Humanos , Aneurisma Intracraniano , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos
2.
Nuklearmedizin ; 54(5): 211-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26213186

RESUMO

AIM: To assess the frequency and the significance of incidental pulmonary lesions with 18F-fluorocholine (18F-FCH) PET/CT in prostate cancer (PCa) patients. PATIENTS, METHODS: 225 consecutive PCa patients referred for 18F-FCH PET/CT (median age 68 years) were retrospectively evaluated for the presence of lesions in the lungs: 173 referred for restaging and 52 for initial staging regarding their high risk of extra prostatic extension. The final diagnosis was based on histopathological or on clinical and radiological follow-up. RESULTS: 13 patients had 18F-FCH positive pulmonary and 8 patients malignant lesions: 5 patients (38%) had a primary lung cancer (2 squamous cell carcinomas, 1 papillary adenocarcinoma, 1 typical pulmonary carcinoid, 1 bronchioloalveolar carcinoma) and 3 patients (23%) PCa metastases. Benign lesions were found in 5 subjects (38%). SUVmax and maximum diameter were neither significantly different in primary and metastatic tumors nor between malignant and benign lesions. CONCLUSIONS: Although our results suggest that incidental uptake in the lungs in PCa patients are nonspecific, their detection may have a significant impact on patient management knowing that more than 60% represent malignant disease.


Assuntos
Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/epidemiologia , Neoplasias Primárias Múltiplas/diagnóstico , Neoplasias Primárias Múltiplas/epidemiologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/epidemiologia , Idoso , Colina/análogos & derivados , Comorbidade , Humanos , Incidência , Achados Incidentais , Masculino , Imagem Multimodal/estatística & dados numéricos , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Suíça/epidemiologia , Tomografia Computadorizada por Raios X/estatística & dados numéricos
3.
Osteoporos Int ; 24(6): 1843-52, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23138338

RESUMO

UNLABELLED: We evaluated the influence of long-term HIV infection and its treatment on distal tibia and radius microstructure. Premenopausal eumenorrheic HIV-positive women displayed trabecular and cortical microstructure alterations, which could contribute to increased bone fragility in those patients. INTRODUCTION: Bone fragility is an emerging issue in HIV-infected patients. Dual-energy X-ray absorptiometry (DXA) quantified areal bone mineral density (BMD) predicts fracture risk, but a significant proportion of fracture risk results from microstructural alterations. METHODS: We studied the influence of long-term HIV infection on bone microstructure as evaluated by high-resolution peripheral quantitative computed tomography (HR-pQCT) in 22 HIV-positive (+ve) premenopausal eumenorrheic women and 44 age- and body mass index (BMI)-matched HIV-negative (-ve) controls. All subjects completed questionnaires regarding calcium/protein intakes and physical activity, and underwent DXA and HR-pQCT examinations for BMD and peripheral skeleton microstructure, respectively. A risk factor analysis of tibia trabecular density using linear mixed models was conducted. RESULTS: In HIV+ve women on successful antiretroviral therapy (undetectable HIV-RNA, median CD4 cell count, 626), infection duration was 16.5 ± 3.5 (mean ± SD) years; median BMI was 22 (IQR, 21-26) kg/m². More HIV+ve women were smokers (82 versus 50 %, p = 0.013). Compared to controls, HIV+ve women had lower lumbar spine (spine T-score -0.70 vs -0.03, p = 0.014), but similar proximal femur BMD. At distal tibia, HIV+ve women had a 14.1 % lower trabecular density and a 13.2 % reduction in trabecular number compared to HIV-ve women (p = 0.013 and 0.029, respectively). HR-pQCT differences in distal radius were significant for cortical density (-3.0 %; p = 0.029). CONCLUSIONS: Compared with HIV-ve subjects, premenopausal HIV+ve treated women had trabecular and cortical bone alterations. Adjusted analysis revealed that HIV status was the only determinant of between group tibia trabecular density differences. The latter could contribute to increased bone fragility in HIV+ve patients.


Assuntos
Fármacos Anti-HIV/uso terapêutico , Densidade Óssea/fisiologia , Infecções por HIV/complicações , Osteoporose/virologia , Absorciometria de Fóton/métodos , Adulto , Estudos de Casos e Controles , Feminino , Colo do Fêmur/fisiopatologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/fisiopatologia , Articulação do Quadril/fisiopatologia , Humanos , Vértebras Lombares/fisiopatologia , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Fraturas por Osteoporose/etiologia , Fraturas por Osteoporose/fisiopatologia , Pré-Menopausa/fisiologia , Rádio (Anatomia)/fisiopatologia , Fatores de Risco , Tíbia/fisiopatologia , Tomografia Computadorizada por Raios X/métodos
4.
Neurocase ; 18(5): 386-91, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22059937

RESUMO

Pervasive developmental disorder is characterized by various symptoms that often include self-injurious behavior (SIB). Episodes of SIB occur in the context of high emotional arousal, anger, or fear and may be related to epilepsy. We report the case of a 20-year-old man with pervasive developmental disorder presenting with SIB non-responsive to antipsychotic medication. Positron emission tomography showed a right temporoparietal hypometabolic focal lesion suggestive of an epileptic focus. Two weeks after initiation of levetiracetam (Keppra®), SIB disappeared, without recurrence 24 months later. Levetiracetam (Keppra®) may be beneficial for such patients.


Assuntos
Anticonvulsivantes/uso terapêutico , Transtornos Globais do Desenvolvimento Infantil/complicações , Deficiência Intelectual/complicações , Piracetam/análogos & derivados , Convulsões/tratamento farmacológico , Comportamento Autodestrutivo/tratamento farmacológico , Criança , Humanos , Levetiracetam , Masculino , Piracetam/uso terapêutico , Convulsões/complicações , Comportamento Autodestrutivo/complicações , Resultado do Tratamento , Adulto Jovem
5.
Phys Med Biol ; 56(10): 3091-106, 2011 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-21508443

RESUMO

The Ingenuity TF PET-MRI is a newly released whole-body hybrid PET-MR imaging system with a Philips time-of-flight GEMINI TF PET and Achieva 3T X-series MRI system. Compared to PET-CT, modifications to the positron emission tomography (PET) gantry were made to avoid mutual system interference and deliver uncompromising performance which is equivalent to the standalone systems. The PET gantry was redesigned to introduce magnetic shielding for the photomultiplier tubes (PMTs). Stringent electromagnetic noise requirements of the MR system necessitated the removal of PET gantry electronics to be housed in the PET-MR equipment room. We report the standard NEMA measurements for the PET scanner. PET imaging and performance measurements were done at Geneva University Hospital as described in the NEMA Standards NU 2-2007 manual. The scatter fraction (SF) and noise equivalent count rate (NECR) measurements with the NEMA cylinder (20 cm diameter) were repeated for two larger cylinders (27 cm and 35 cm diameter), which better represent average and heavy patients. A NEMA/IEC torso phantom was used for overall assessment of image quality. The transverse and axial resolution near the center was 4.7 mm. Timing and energy resolution of the PET-MR system were measured to be 525 ps and 12%, respectively. The results were comparable to PET-CT systems demonstrating that the effect of design modifications required on the PET system to remove the harmful effect of the magnetic field on the PMTs was negligible. The absolute sensitivity of this scanner was 7.0 cps kBq(-1), whereas SF was 26%. NECR measurements performed with cylinders having three different diameters, and image quality measurements performed with IEC phantom yielded excellent results. The Ingenuity TF PET-MRI represents the first commercial whole-body hybrid PET-MRI system. The performance of the PET subsystem was comparable to the GEMINI TF PET-CT system using phantom and patient studies. It is conceived that advantages of hybrid PET-MRI will become more evident in the near future.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/normas , Tomografia por Emissão de Pósitrons/normas , Espalhamento de Radiação , Contagem de Cintilação , Imagem Corporal Total
6.
Nuklearmedizin ; 49(5): 173-82, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20664888

RESUMO

PURPOSE: to evaluate the mean effective radiation dose of 13N-ammonia PET/CT and ECG-pulsing CT angiography (CTA) in the evaluation of myocardial perfusion, myocardial blood flow (MBF) and coronary morphology for the identification of subclinical CAD. PATIENTS, MATERIAL, METHODS: following rest-stress 13N-ammonia PET/CT perfusion imaging and MBF quantification, ECG-pulsing CTA at a pulse window of 70% of the R-R cycle was performed in ten healthy controls and in sixteen individuals with cardiovascular risk factors. Individual radiation dose exposure for ECG-pulsing CTA was estimated from the dose-length product. RESULTS: PET demonstrated normal perfusion in all study individuals, while hyperemic MBFs during dipyridamole stimulation and the myocardial flow reserve (MFR) in cardiovascular risk individuals were significantly lower than in healthy controls (1.34±0.26 vs. 2.28±0.47 ml/g/min and 1.48±0.39 vs. 3.24±0.81, both p≤0.0001). Further, ECG-pulsing CTA identified mild calcified and non-calcified coronary plaque burden in 7 (43%) individuals of the cardiovascular risk group. Rest-stress 13N-ammonia PET/CT perfusion study yielded a mean effective radiation dose of 3.07±0.06 mSv (2.07±0.06 mSv from the rest-stress 13N-ammonia injections and 1.0 mSv from the 2 CT transmission scans), while ECG-pulsing CTA was associated with 5.57±2.00 mSv. The mean effective radiation dose of the combined 13N-ammonia PET/CT and ECG-pulsing CTA exams in the evaluation of myocardial perfusion and coronary morphology was 8.0±1.5 mSv. CONCLUSION: 13N-ammonia PET/CT and ECG-pulsing CTA affords cardiac hybrid imaging studies in the evaluation of subclinical CAD with a relatively low mean effective radiation exposure of 8.0±1.5mSv.


Assuntos
Angiografia Coronária/métodos , Reperfusão Miocárdica/métodos , Adulto , Idoso , Amônia , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada Espiral/métodos , Tomografia Computadorizada por Raios X/métodos
7.
Yearb Med Inform ; : 167-72, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19855892

RESUMO

OBJECTIVE: To review the rapid evolution of imaging informatics dealing with issues of management and communication of digital images starting from the era of simple storage and transfer of images to today's world of interactive navigation in large sets of multidimensional data. METHODS: This paper will review the initial concepts of Picture Archiving and Communication Systems (PACS) and the early developments and standardization efforts that lead to the deployment of large intra-institutional networks of image distribution allowing radiologists and physicians to access and review images digitally. With the deployment of PACS came along the need for advanced tools for image visualization and image analysis. RESULTS: Review of the history of PACS and Imaging Informatics clearly shows that the early developments were focused on the radiologist's requirements for diagnosis and image interpretation. These early developments lagged behind the rapid adoption of digital imaging in areas outside radiology. Only recently, imaging informatics shifted toward the development of new tools geared toward the needs of other users such as surgeons, referring physicians and care-providers, and even for the patients themselves. Also in the recent years, the development of multimedia and communication tools in the consumer market has influenced the design and strategic development of image management platforms inside and outside healthcare institutions. CONCLUSIONS: The focus of imaging informatics has clearly shifted in the last decade from basic infrastructure design to complete data and image navigation systems. While the challenge of storing and managing large volumes of imaging data have slowly vanished with the rapid development if information technology, the new challenge emerged from the new requirements of image manipulation and analysis in clinical practice.


Assuntos
Diagnóstico por Imagem/história , Sistemas de Informação em Radiologia/história , História do Século XX , História do Século XXI , Humanos , Sistemas de Informação em Radiologia/normas
8.
Nuklearmedizin ; 48(1): 1-9; quiz N2-3, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19212605

RESUMO

AIM: Contribution of 3-phase 18F-fluorocholine PET/CT in suspected prostate cancer recurrence at early rise of PSA. PATIENTS, METHODS: Retrospective analysis was performed in 47 patients after initial treatment with radiotherapy (n=30) or surgery (n=17). Following CT, 10 minutes list-mode PET acquisition was done over the prostate bed after injection of 300 MBq of 18F-fluorocholine. Three timeframes of 3 minutes each were reconstructed for analysis. All patients underwent subsequent whole body PET/CT. Delayed pelvic PET/CT was obtained in 36 patients. PET/CT was interpreted visually by two observers and SUVmax determined for suspicious lesions. Biopsies were obtained from 13 patients. RESULTS: Biopsies confirmed the presence of cancer in 11 of 13 patients with positive PET for a total of 15 local recurrences in which average SUVmax increased during 14 minutes post injection and marginally decreased in delayed scanning. Conversely inguinal lymph nodes with mild to moderate metabolic activity on PET showed a clearly different pattern with decreasing SUVmax on dynamic images. Three-phase PET/CT contributed to the diagnostic assessment of 10 of 47 patients with biological evidence of recurrence of cancer. It notably allowed the discrimination of confounding blood pool or urinary activity from suspicious hyperactivities. PET/CT was positive in all patients with PSA>or=2 ng/ml (n=34) and in 4/13 patients presenting PSA values<2 ng/ml. CONCLUSION: 18F-fluorocholine 3-phase PET/CT showed a progressively increasing SUVmax in biopsy confirmed cancer lesions up to 14 minutes post injection while decreasing in inguinal lymph nodes interpreted as benign. Furthermore, it was very useful in differentiating local recurrences from confounding blood pool and urinary activity.


Assuntos
Colina/análogos & derivados , Radioisótopos de Flúor , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/patologia , Recidiva , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
9.
Radiologe ; 49(1): 43-58, 2009 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-19050845

RESUMO

Cross-sectional imaging with CT, MRI and more recently PET CT plays an indispensable complementary role to endoscopy in the pretherapeutic diagnostic and staging of laryngeal neoplasms and in the evaluation of the operated or irradiated larynx. Adequate interpretation of the CT, PET CT and MR images requires a thorough knowledge of the patterns of submucosal spread and familiarity with the diagnostic signs of neoplastic invasion as seen with each modality. In addition, one should be aware of the implications of imaging for staging and treatment. Both CT and MR imaging are highly sensitive for the detection of neoplastic invasion of the preepiglottic and paraglottic spaces, subglottic region and cartilage. The high negative predictive value of both CT and MRI allows a relatively reliable exclusion of neoplasm cartilage invasion. The specificity of both CT and MRI is, however, moderately high and both methods may, therefore, overestimate the extent of tumor spread. However, recent investigations have shown that the specificity of MRI may be significantly improved by using new diagnostic criteria which allow differentiation of tumor from peritumoral inflammation in many instances. Both cross-sectional imaging methods also significantly improve the pretherapeutic staging accuracy of laryngeal tumors if used in addition to clinical examination and endoscopic biopsy. In the presence of a submucosal mass, CT and MRI play a key role for the diagnosis, as they may characterize the lesion, reliably depict its submucosal extent and guide the endoscopist to perform deep biopsies which allow the definitive histological diagnosis. Cross-sectional imaging also plays a key role in the evaluation of laryngoceles, recurrent laryngeal nerve paralysis and fractures.


Assuntos
Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/cirurgia , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Neoplasias Laríngeas/diagnóstico , Neoplasias Laríngeas/cirurgia , Laringe/patologia , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Complicações Pós-Operatórias/diagnóstico , Tomografia Computadorizada por Raios X , Biópsia , Carcinoma de Células Escamosas/patologia , Meios de Contraste/administração & dosagem , Diagnóstico Diferencial , Humanos , Doenças da Laringe/diagnóstico , Doenças da Laringe/patologia , Doenças da Laringe/cirurgia , Neoplasias Laríngeas/patologia , Laringectomia , Laringe/lesões , Metástase Linfática/patologia , Invasividade Neoplásica , Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Complicações Pós-Operatórias/patologia
10.
Methods Inf Med ; 41(3): 237-42, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12162151

RESUMO

OBJECTIVE: To report about the work of Prof. Jean-Raoul Scherrer, and show how his humanist vision, his medical skills and his scientific background have enabled and shaped the development of medical informatics over the last 30 years. RESULTS: Starting with the mainframe-based patient-centered hospital information system DIOGENE in the 70s, Prof. Scherrer developed, implemented and evolved innovative concepts of man-machine interfaces, distributed and federated environments, leading the way with information systems that obstinately focused on the support of care providers and patients. Through a rigorous design of terminologies and ontologies, the DIOGENE data would then serve as a basis for the development of clinical research, data mining, and lead to innovative natural language processing techniques. In parallel, Prof. Scherrer supported the development of medical image management, ranging from a distributed picture archiving and communication systems (PACS) to molecular imaging of protein electrophoreses. Recognizing the need for improving the quality and trustworthiness of medical information on the Web, Prof. Scherrer created the Health-On-the-Net (HON) foundation. CONCLUSIONS: These achievements, made possible thanks to his visionary mind, deep humanism, creativity, generosity and determination, have made of Prof. Scherrer a true pioneer and leader of the human-centered, patient-oriented application of information technology for improving healthcare.


Assuntos
Informática Médica/história , História do Século XX , Suíça
12.
Radiographics ; 20(6): 1807-16, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11112830

RESUMO

Three-dimensional (3D) computer modeling, simulation, and rendering techniques were used to redesign the diagnostic workstations and radiology reading rooms for a proposed hospital with particular attention given to lighting conditions, noise reduction, and optimal use of limited workspace. The results were presented to a panel of multidisciplinary experts and iteratively improved and redesigned with the development or addition of new design criteria or requirements. These 3D techniques allowed faster, more efficient design and presentation of multiple options than is possible with traditional two-dimensional drawings, thereby expediting decision making and resulting in significant savings. The current workstation designs can easily be developed and implemented with available technology at a reasonable cost. They can also accommodate anticipated advances in computer and display technology as well as new imaging paradigms (eg, changes in keyboard and control ergonomics such as adjustable virtual keys on touch-sensitive screens, digital drawing tablets for annotations and controls, direct film digitizing, personal identification devices, offline media readers such as compact disks and digital videodisks, and speech recognition and voice activation). Use of 3D techniques in designing other parts of the radiology department (eg, examination rooms, technologists' areas, physicians' offices) could greatly improve and facilitate the design and implementation of complex settings in these work areas.


Assuntos
Desenho Assistido por Computador , Arquitetura de Instituições de Saúde , Serviço Hospitalar de Radiologia , Simulação por Computador , Humanos , Imageamento Tridimensional , Sistemas de Informação em Radiologia
13.
J Thorac Imaging ; 15(4): 218-29, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11039610

RESUMO

Comprehensive cardiac assessment embraces virtually every imaging modality and includes information about coronary vascular anatomy as well as cardiac morphology, function, perfusion, metabolism, and tissue characterization. Through sophisticated computer processing and image analysis, newer imaging technologies such as computed tomography (CT), magnetic resonance (MR), MR spectroscopy, and positron emission tomography now provide quantitative information that may obviate more invasive angiographic assessment. Currently, no single imaging technology realizes all questions relating to cardiac form and function, and many of the technologies overlap in the content and quality of information they provide. This overview seeks to provide a broad perspective on current cardiac imaging, articulating the benefits of various technologies and their limitations.


Assuntos
Diagnóstico por Imagem , Cardiopatias/diagnóstico , Aorta/patologia , Aortografia , Angiografia Coronária , Vasos Coronários/patologia , Ecocardiografia , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Tomografia Computadorizada de Emissão , Tomografia Computadorizada por Raios X
14.
Radiographics ; 20(5): 1279-99; discussion 1299-301, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10992018

RESUMO

Magnetic resonance (MR) imaging is rapidly gaining acceptance as an accurate, reproducible, noninvasive method for optimal assessment of structural and functional parameters in patients with valvular heart disease. The severity of valvular regurgitation can be evaluated with cine gradient-echo MR imaging, which allows measurement of the area of the signal void corresponding to the abnormal flow jet. Alternatively, this modality can be used to obtain ventricular volumetric measurements and calculate the regurgitant fraction, or velocity-encoded cine (VEC) MR imaging can be used to quantify regurgitant blood flow. The severity of valvular stenosis can be determined by evaluating the flow jet and associated findings with either modality or by using VEC MR imaging to calculate the transvalvular pressure gradient and valve area. Dynamic MR imaging allows accurate assessment of ventricular function and comprehensive evaluation of pathophysiologic changes. In addition, good interstudy reproducibility suggests a role for VEC MR imaging in assessing the effects of therapeutic intervention and monitoring regurgitant fraction, thereby helping in surgical planning and the prevention of ventricular dysfunction. With greater cost-effectiveness and the increasing availability of new hardware and more advanced techniques, MR imaging will become a routine procedure in valvular heart disease.


Assuntos
Doenças das Valvas Cardíacas/diagnóstico , Valvas Cardíacas/patologia , Imagem Cinética por Ressonância Magnética , Velocidade do Fluxo Sanguíneo , Diagnóstico Diferencial , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador , Contração Miocárdica , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
15.
Abdom Imaging ; 25(4): 333-40, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10926185

RESUMO

Information technology is becoming a vital component of all health care enterprises, from managed care services to large hospital networks, that provides the basis of electronic patient records and hospital-wide information. The rationale behind such systems is deceptively simple: physicians want to sit down at a single workstation and call up all information, both clinical data and medical images, concerning a given patient. Picture archiving and communication systems (PACS) are responsible for solving the problem of acquiring, transmitting, and displaying radiologic images. The major benefit of PACS resides in its ability to communicate images and reports to referring physicians in a timely and reliable fashion. With the changes in economics and the shift toward managed and capitated care, the teleradiology component of PACS is rapidly gaining momentum. In allowing remote coverage of multiple sites by the same radiologists and remote consultations and expert opinion, teleradiology is in many instances the only option to maintain economically viable radiologic settings. The technical evolution toward more integrated systems and the shift toward Web-based technology is rapidly merging the two concepts of PACS and teleradiology in global image management and communication systems.


Assuntos
Intensificação de Imagem Radiográfica , Sistemas de Informação em Radiologia , Custos e Análise de Custo , Humanos , Internet , Aplicações da Informática Médica , Sistemas de Informação em Radiologia/economia , Sistemas de Informação em Radiologia/tendências , Telerradiologia/economia , Telerradiologia/tendências
16.
Int J Radiat Oncol Biol Phys ; 47(5): 1449-56, 2000 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-10889401

RESUMO

PURPOSE: To describe the implementation and use of an electronic patient-referral system as an aid to the efficient referral of patients to a remote and specialized treatment center. METHODS AND MATERIALS: A system for the exchange of radiotherapy data between different commercial planning systems and a specially developed planning system for proton therapy has been developed through the use of the PAPYRUS diagnostic image standard as an intermediate format. To ensure the cooperation of the different TPS manufacturers, the number of data sets defined for transfer has been restricted to the three core data sets of CT, VOIs, and three-dimensional dose distributions. As a complement to the exchange of data, network-wide application-sharing (video-conferencing) technologies have been adopted to provide methods for the interactive discussion and assessment of treatments plans with one or more partner clinics. RESULTS: Through the use of evaluation plans based on the exchanged data, referring clinics can accurately assess the advantages offered by proton therapy on a patient-by-patient basis, while the practicality or otherwise of the proposed treatments can simultaneously be assessed by the proton therapy center. Such a system, along with the interactive capabilities provided by video-conferencing methods, has been found to be an efficient solution to the problem of patient assessment and selection at a specialized treatment center, and is a necessary first step toward the full electronic integration of such centers with their remotely situated referral centers.


Assuntos
Redes de Comunicação de Computadores/normas , Eletrônica Médica/normas , Sistemas de Informação em Radiologia/normas , Encaminhamento e Consulta/normas , Redes de Comunicação de Computadores/organização & administração , Humanos , Sistemas de Informação em Radiologia/organização & administração , Encaminhamento e Consulta/organização & administração , Telecomunicações/organização & administração , Telecomunicações/normas
17.
IEEE Trans Inf Technol Biomed ; 4(2): 108-15, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10866409

RESUMO

A web-based video transmission of images from CT and MRI consoles was implemented in an Intranet environment for real-time monitoring of ongoing procedures. Images captured from the consoles are compressed to video resolution and broadcast through a web server. When called upon, the attending radiologists can view these live images on any computer within the secured Intranet network. With adequate compression, these images can be displayed simultaneously in different locations at a rate of 2 to 5 images/s through a standard local-area network. While the quality of the images was insufficient for diagnostic purposes, our users survey showed that they were suitable for supervising a procedure, positioning the imaging slices, and for routine quality checking before completion of a study. The system was implemented at UCLA to monitor nine CT's and six MRI's distributed in four different buildings. This system significantly improved the radiologists productivity by saving valuable time spent in trips between reading rooms and examination rooms. It also improved patient care and throughput by reducing the time spent waiting for the radiologists to check a study before removing the patient from the scanner.


Assuntos
Internet , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Gravação de Videoteipe , Interface Usuário-Computador
18.
J Magn Reson Imaging ; 10(5): 639-55, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10548772

RESUMO

Magnetic resonance imaging (MRI) has evolved sufficiently to be recognized as a useful complementary noninvasive method to echocardiography in the evaluation of congenital heart disease (CHD). In some cases, MRI is superior to other imaging modalities, particularly in the evaluation of thoracic aortic anomalies and in defining the anatomy of central pulmonary arteries; it is also the procedure of choice in the postoperative follow-up of patients with CHD. Recent technological advances permit not only morphological evaluation (provided by spin-echo and MR angiographic techniques) but functional and flow information (provided by fast cine-GE and velocity-encoded sequences), causing it to be recognized by pediatric cardiologists and cardiac surgeons as an unavoidable technique for pre- and postoperative evaluation of some CHD. This review describes the various techniques used in the evaluation of CHD with emphasis on recent developments as well as recognized clinical applications. J. Magn. Reson. Imaging 1999;10:639-655.


Assuntos
Cardiopatias Congênitas/diagnóstico , Imageamento por Ressonância Magnética , Adulto , Aorta Torácica/anormalidades , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Artéria Pulmonar/anormalidades
19.
J Digit Imaging ; 12(2 Suppl 1): 139-40, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10342193

RESUMO

Recent advances in magnetic resonance imaging (MRI) are rapidly making this modality the imaging method of choice for image-guided neurosurgical operations. However, to be ready for its prime time in the operating room (OR), utilization of MRI in the OR requires development of better techniques for image-guided navigation, as well as interactive real-time teleradiologic methods that will allow tele-collaboration between the surgeon and the radiologist. This presentation describes our work in progress toward achievement of teleradiology in the OR.


Assuntos
Salas Cirúrgicas/tendências , Telerradiologia/tendências , Sistemas Computacionais , Apresentação de Dados , Previsões , Humanos , Processamento de Imagem Assistida por Computador , Relações Interprofissionais , Imageamento por Ressonância Magnética , Neurocirurgia , Radiologia , Radiologia Intervencionista , Consulta Remota
20.
Stud Health Technol Inform ; 52 Pt 2: 1075-9, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-10384626

RESUMO

A hospital-wide Picture Archiving and Communication System (PACS) is currently under development at the University Hospital of Geneva. After a first implementation including two oneterabyte optical libraries, the system is expanded to integrate all the imaging modalities of the hospital. The new storage requirement is 10 terabytes to cover three year archive. A large distributed image archive has been designed including new archive servers for long-term storage and display servers for medium-term storage. The acquisition, archive and distribution cycles are performed using separated networks combining Fast Ethernet and Ethernet. Image files are distributed to the wide-hospital using a prefetching strategy or an Intranet server, RADIOLAB. The first mode takes advantage of the fully integrated hospital information system DIOGENE 2 to allow the automatic retrieval of studies in advance. The second mode provides a convivial study selection from any conventional WWW (World Wide Web) browser. Image files are then transmitted to the user's display station using HTTP (HyperText Transfer Protocol) and handled by OSIRIS software, which acts as a helper or viewer. Such a system is expected to meet the time requirement, which is less than three seconds per image.


Assuntos
Redes de Comunicação de Computadores , Sistemas de Informação em Radiologia/organização & administração , Sistemas de Informação Hospitalar , Hospitais Universitários , Humanos , Armazenamento e Recuperação da Informação , Redes Locais , Suíça , Integração de Sistemas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA