Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Emerg Med ; 82(2): 194-202, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36774205

RESUMO

STUDY OBJECTIVE: The diagnostic performance of T-wave amplitudes for the detection of myocardial infarction is largely unknown. We aimed to address this knowledge gap. METHODS: T-wave amplitudes were automatically measured in 12-lead ECGs of patients presenting with acute chest discomfort to the emergency department within a prospective diagnostic multicenter study. The final diagnosis was centrally adjudicated by 2 independent cardiologists. Patients with left ventricular hypertrophy, complete left bundle branch block, or paced ventricular depolarization were excluded. The performance for lead-specific 95th-percentile thresholds were reported as likelihood ratios (lr), specificity, and sensitivity. RESULTS: Myocardial infarction was the final diagnosis in 445 (18%) of 2457 patients. In most leads, T-wave amplitudes tended to be greater in patients without myocardial infarction than those with myocardial infarction, and T-wave amplitude exceeding the 95th percentile had positive and negative lr close to 1 or with confidence intervals (CIs) crossing 1. The exceptions were leads III, aVR, and V1, which had positive lrs of 3.8 (95% CI, 2.7 to 5.3), 4.3 (95% CI, 3.1 to 6.0) and 2.0 (95% CI, 1.4 to 2.9), respectively. These leads normally have inverted T waves, so T-wave amplitude exceeding the 95th percentile reflects upright rather than increased-amplitude hyperacute T waves. CONCLUSION: Hyperacute T waves, when defined as increased T-wave amplitude exceeding the 95th percentile, did not provide useful information in diagnosing myocardial infarction in this sample.


Assuntos
Infarto do Miocárdio , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Infarto do Miocárdio/diagnóstico , Arritmias Cardíacas , Eletrocardiografia , Diagnóstico Precoce
2.
Eur Heart J Acute Cardiovasc Care ; 11(11): 834-840, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36179255

RESUMO

AIMS: After rule-out of non-ST elevation myocardial infarction (NSTEMI) with the European Society of Cardiology (ESC) 0/1 h-algorithms, it is unclear which patients require further anatomical or functional cardiac testing. To test the safety and efficacy of the no-objective-testing (NOT)-rules after NSTEMI rule-out by the ESC 0/1 h-algorithms. METHODS AND RESULTS: International, prospective, diagnostic multicentre study enrolling adult patients presenting with chest pain to the emergency department. Central adjudication of final diagnosis by two independent cardiologists using information including cardiac imaging. Primary endpoints were the safety and efficacy of the NOT-rules for the rule-out of major adverse cardiovascular events (MACE). Secondary endpoints included 365-day and 2-year MACE. Among 4804 and 4569 patients with available 0/1 h high-sensitivity cardiac troponin (hs-cTn)T-Elecsys or hs-cTnI-Architect concentrations, 2783 (58%) and 2252 (49%) were eligible for application of the NOT-rules after rule-out of NSTEMI by the ESC hs-cTnT/I-0/1h-algorithm. The first rule identified 26% of patients with a sensitivity of 100% (95%CI 98.3-100%) and a negative predictive value (NPV) of 100% (95% CI, n.c.). The second and third rules both identified 31% of patients with a sensitivity of 99.5% (95% CI 97.4-99.9%) and a NPV of 99.9% (95% CI 99.2-99.9%). Similar findings emerged for hs-cTnI. High safety was confirmed for rule-out of 365-day and 2-year MACE and proven to be superior to the HEART Score. CONCLUSION: All three NOT-rules performed very well for rule-out of MACE. The third NOT-rule best balanced feasibility, safety, and efficacy by identifying nearly one out of three patients as low-risk and may not require further cardiac testing. https://clinicaltrials.gov/ct2/show/NCT00470587.


Assuntos
Cardiologia , Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Adulto , Humanos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Estudos Prospectivos , Infarto do Miocárdio/diagnóstico , Troponina I , Algoritmos , Biomarcadores , Troponina T
3.
Eur Heart J Acute Cardiovasc Care ; 11(1): 62-74, 2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-34195803

RESUMO

AIMS: To directly compare the diagnostic accuracy of high-sensitivity cardiac troponin (hs-cTn) T vs. hs-cTnI in the early non-invasive differentiation of Type 1 myocardial infarction (T1MI) due to plaque rupture and atherothrombosis from Type 2 myocardial infarction (T2MI) due to supply-demand mismatch. METHODS AND RESULTS: In a prospective multicentre diagnostic study, two independent cardiologists centrally adjudicated the final diagnosis of T1MI vs. T2MI according to the fourth universal definition of myocardial infarction (MI), using all available clinical information including cardiac imaging in patients presenting with acute chest pain. Diagnostic accuracy was quantified by the area under the receiver operating characteristics curve (AUC). The most extensively validated hs-cTnT-Elecsys and hs-cTnI-Architect assays were measured at presentation, 1 h, and 2 h. Among 5887 patients, 1106 (19%) had a final diagnosis of MI, including 860 (78%) T1MI and 246 (22%) T2MI. The AUC of hs-cTnT-Elecsys to differentiate T1MI from T2MI was moderate and comparable to that provided by hs-cTnI-Architect: hs-cTnT-Elecsys AUC-presentation 0.67 [95% confidence interval (CI) 0.64-0.71], AUC-1 h 0.70 (95% CI 0.66-0.74), and AUC-2 h 0.71 (95% CI 0.66-0.75) vs. hs-cTnI-Architect AUC-presentation 0.71 (95% CI 0.67-0.74), AUC-1 h 0.72 (95% CI 0.68-0.76), and AUC-2 h 0.74 (95% CI 0.69-0.78), all P = not significant (NS). Similarly, the AUC of absolute changes was moderate and comparable for hs-cTnT-Elecsys and hs-cTnI-Architect (all P = NS). Cut-off concentrations achieving at least 90% specificity for the differentiation of T1MI vs. T2MI were >114 ng/L for hs-cTnT-Elecsys [odds ratio (OR) 4.2, 95% CI 2.7-6.6] and >371 ng/L for hs-cTnI-Architect (OR 4.0, 95% CI 2.6-6.2). CONCLUSION: hs-cTnT-Elecsys and hs-cTnI-Architect provided comparable, albeit only moderate, diagnostic accuracy for the early differentiation of T1MI vs. T2MI. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587, https://clinicaltrials.gov/ct2/show/NCT00470587.


Assuntos
Infarto do Miocárdio , Troponina T , Biomarcadores , Diagnóstico Precoce , Humanos , Infarto do Miocárdio/diagnóstico , Estudos Prospectivos
4.
Circulation ; 144(10): 773-787, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34376064

RESUMO

BACKGROUND: The non-ST-segment-elevation myocardial infarction (NSTEMI) guidelines of the European Society of Cardiology (ESC) recommend a 3h cardiac troponin determination in patients triaged to the observe-zone of the ESC 0/1h-algorithm; however, no specific cutoff for further triage is endorsed. Recently, a specific cutoff for 0/3h high-sensitivity cardiac troponin T (hs-cTnT) change (7 ng/L) was proposed, warranting external validation. METHODS: Patients presenting with acute chest discomfort to the emergency department were prospectively enrolled into an international multicenter diagnostic study. Final diagnoses were centrally adjudicated by 2 independent cardiologists applying the fourth universal definition of myocardial infarction, on the basis of complete cardiac workup, cardiac imaging, and serial hs-cTnT. Hs-cTnT concentrations were measured at presentation, after 1 hour, and after 3 hours. The objective was to externally validate the proposed cutoff, and if necessary, derive and internally as well as externally validate novel 0/3h-criteria for the observe-zone of the ESC 0/1h-hs-cTnT-algorithm in an independent multicenter cohort. RESULTS: Among 2076 eligible patients, application of the ESC 0/1h-hs-cTnT-algorithm triaged 1512 patients (72.8%) to either rule out or rule in NSTEMI, leaving 564 patients (27.2%) in the observe-zone (adjudicated NSTEMI prevalence, 120/564 patients, 21.3%). The suggested 0/3h-hs-cTnT-change of <7 ng/L triaged 517 patients (91.7%) toward rule-out, resulting in a sensitivity of 33.3% (95% CI, 25.5-42.2), missing 80 patients with NSTEMI, and ≥7 ng/L triaged 47 patients toward rule-in (8.3%), resulting in a specificity of 98.4% (95% CI, 96.8-99.2). Novel derived 0/3h-criteria for the observe-zone patients ruled out NSTEMI with a 3h hs-cTnT concentration <15 ng/L and a 0/3h-hs-cTnT absolute change <4 ng/L, triaging 138 patients (25%) toward rule-out, resulting in a sensitivity of 99.2% (95% CI, 96.0-99.9), missing 1 patient with NSTEMI. A 0/3h-hs-cTnT absolute change ≥6 ng/L triaged 63 patients (11.2%) toward rule-in, resulting in a specificity of 98% (95% CI, 96.2-98.9) Thereby, the novel 0/3h-criteria reduced the number of patients in the observe zone by 36%s and the number of type 1 myocardial infarction by 50%. Findings were confirmed in both internal and external validation. CONCLUSIONS: A combination of a 3h-hs-cTnT concentration (<15 ng/L) and a 0/3h absolute change (<4 ng/L) is necessary to safely rule out NSTEMI in patients remaining in the observe-zone of the ESC 0/1h-hs-cTnT-algorithm. Registration: URL: https://clinicaltrials.gov; Unique identifier: NCT00470587.


Assuntos
Algoritmos , Sistema Cardiovascular/fisiopatologia , Infarto do Miocárdio/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Técnicas de Imagem Cardíaca/métodos , Cardiologia/métodos , Coleta de Dados , Testes Diagnósticos de Rotina/efeitos adversos , Coração/fisiopatologia , Humanos , Infarto do Miocárdio/fisiopatologia
6.
Eur Heart J Acute Cardiovasc Care ; 10(7): 746-755, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33620434

RESUMO

AIMS: Diagnosis of acute myocardial infarction (AMI) can be challenging in patients with prior coronary artery bypass grafting (CABG). METHODS AND RESULTS: Final diagnoses were adjudicated by two independent cardiologists using the universal definition of AMI among patients presenting to the emergency department (ED) with suspected AMI. Diagnostic accuracy of 34 chest pain characteristics (CPCs) and four electrocardiogram (ECG) signatures stratified according to the presence or absence of prior CABG were prospectively quantified. Among 4015 patients (no prior CABG: n = 3686; prior CABG: n = 329), prevalence of AMI and unstable angina were higher in patients with prior CABG (35% vs. 18%; 26% vs. 8%; both P < 0.001). Three CPCs (9%) and two electrocardiographic findings (50%) showed a different diagnostic performance (interaction P < 0.05) with loss of diagnostic value in patients with prior CABG. The diagnostic accuracy as quantified by the area under the curve (AUC) of the integrated clinical judgement was moderate to good in patients with prior CABG, and significantly lower compared to patients without prior CABG [AUC 0.80 (95% confidence interval (CI) 0.75-0.84) vs. AUC 0.87 (95% CI 0.86-0.89); P = 0.004]. Time to discharge from the ED was significantly longer in patients with prior CABG [359 (215-525) min vs. 300 (192-435) min; P < 0.001]. Key findings were confirmed in a large independent external validation cohort (n = 13 653). CONCLUSIONS: Patients with prior CABG presenting with suspected AMI have a high prevalence of AMI and unstable angina and lower diagnostic accuracy of CPCs and the ECG, possibly justifying liberal use of early coronary angiography in these vulnerable patients. CLINICALTRIALS.GOV REGISTRY: Number NCT00470587.


Assuntos
Ponte de Artéria Coronária , Infarto do Miocárdio , Angina Instável , Dor no Peito , Eletrocardiografia , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia
7.
Clin Biochem ; 91: 16-25, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33636187

RESUMO

BACKGROUND: Combining high-sensitivity cardiac troponin (hs-cTn) with estimated glomerular filtration rate and glucose within the Clinical Chemistry Score (CCS) could help in the assessment of patients with suspected acute myocardial infarction (AMI). METHODS: In patients presenting with suspected AMI to the emergency department, we aimed to externally validate the performance of the CCS in a prospective international multicenter study and to directly compare the diagnostic and prognostic performance of the CCS with hs-cTnT and hs-cTnI baseline levels alone using a single cut-off approach. The diagnostic endpoint was diagnostic accuracy for AMI as centrally adjudicated by two independent cardiologists including cardiac imaging and serial hs-cTnT/I measurements. The prognostic endpoint was 30-day AMI or death. RESULTS: AMI was the final diagnosis in 620/3827 patients (16.2%) adjudicated with hs-cTnT and 599 patients (15.7%) adjudicated with hs-cTnI. The CCS resulted in high diagnostic accuracy for AMI and prognostic accuracy for 30-days AMI/death as quantified by the area under the receiver-operating characteristic curve (AUC), using hs-cTnT 0.90 (95%CI 0.89-0.91) and 0.89 (95%CI 0.88-0.90), using hs-cTnI 0.91 (95%Cl 0.90-0.92) and 0.90 (95%CI 0.89-0.91) respectively. E.g. a CCS of 0 points resulted in a sensitivity of 99.8% (95%CI 99.1-100%) for rule-out of index AMI and 99.5% (95%CI 98.5-100%) for AMI/death at 30 days for hs-cTnT and 99.8% (95%CI 98.9-100%) and 99.6% (95%CI 98.6-100%) using hs-cTnI. Overall, the single hs-cTnT/I measurement approach provided comparable diagnostic (sensitivity 99.5-99.7%) and prognostic (sensitivity 98.9-99.5%) performance versus the CCS. INTERPRETATION: The CCS provided high diagnostic and prognostic performance also in this independent large validation cohort. A single hs-cTnT/I measurement approach for rule-out MI yielded similar estimates.


Assuntos
Infarto do Miocárdio/sangue , Infarto do Miocárdio/mortalidade , Troponina C/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taxa de Sobrevida
9.
J Am Coll Cardiol ; 75(10): 1111-1124, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32164884

RESUMO

BACKGROUND: Until now, high-sensitivity cardiac troponin (hs-cTn) assays were mainly developed for large central laboratory platforms. OBJECTIVES: This study aimed to assess the clinical performance of a point-of-care (POC)-hs-cTnI assay in patients with suspected myocardial infarction (MI). METHODS: This study enrolled patients presenting to the emergency department with symptoms suggestive of MI. Two cardiologists centrally adjudicated the final diagnosis using all clinical data including cardiac imaging. The primary objective was to directly compare diagnostic accuracy of POC-hs-cTnI-TriageTrue versus best-validated central laboratory assays. Secondary objectives included the derivation and validation of a POC-hs-cTnI-TriageTrue-specific 0/1-h algorithm. RESULTS: MI was the adjudicated final diagnosis in 178 of 1,261 patients (14%). The area under the curve (AUC) for POC-hs-cTnI-TriageTrue at presentation was 0.95 (95% confidence interval [CI]: 0.93 to 0.96) and was at least comparable to hs-cTnT-Elecsys (AUC: 0.94; 95% CI: 0.93 to 0.96; p = 0.213) and hs-cTnI-Architect (AUC: 0.92; 95% CI: 0.90 to 0.93; p < 0.001). A single cutoff concentration <3 ng/l at presentation identified 45% of patients at low risk with a negative predictive value (NPV) of 100% (95% CI: 99.4% to 100%). A single cutoff concentration >60 ng/l identified patients at high risk with a positive predictive value (PPV) of 76.8% (95% CI: 68.9% to 83.6%). The 0/1-h algorithm ruled out 55% of patients (NPV: 100%; 95% CI: 98.8% to 100%), and ruled in 18% of patients (PPV: 76.8%; 95% CI: 67.2% to 84.7%). Ruled-out patients had cumulative event rates of 0% at 30 days and 1.6% at 2 years. This study confirmed these findings in a secondary analysis including hs-cTnI-Architect for central adjudication. CONCLUSIONS: The POC-hs-cTnI-TriageTrue assay provides high diagnostic accuracy in patients with suspected MI with a clinical performance that is at least comparable to that of best-validated central laboratory assays. (Advantageous Predictors of Acute Coronary Syndromes Evaluation Study [APACE]; NCT00470587).


Assuntos
Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Troponina I/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Diagnóstico Precoce , Serviço Hospitalar de Emergência , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...