Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Methods Appl Fluoresc ; 10(4)2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35901801

RESUMO

Creatinine (Crn) is an important excretory product of the human body. Medical laboratory technology has improved over years and brought many advancements in clinical diagnostics equipment, and testing techniques and made the tests more efficient. Yet, the quantitative analysis of Crn is still carried out by the classical Jaffe's reaction (using Picric acid (PA) with NaOH) method. Since PA is hazardous to human health, alternative solutions such as; nanoparticles and surface-modified nanoparticles can be used. Exploring the optoelectronic properties of carbon-based quantum dots for biomolecule sensing is of current interest among researchers. Nitrogen functionalized graphene quantum dots (Alk-NGQDs) measured featured Crn easier and reduced the time taken for the test carried out in laboratories. The synthesized Alk-NGQDs optical, structural, morphological properties, surface and compositions are studied through XPS, HRTEM, XRD, FTIR, and spectroscopic techniques. Alk-NGQDs at alkaline conditions (pH 9.5) form a stable complex with Crn through intermolecular charge transfer (ICT). The fluorescence titration method is used to sense Crn in commercial Crn samples and human blood serum. To understand the efficacy of sensing creatinine using Alk-NGQDs, working concentration, fluorescence quantum yield, the limit of detection, and quenching constant are calculated using the Stern-Volmer plot. The emission property of Alk-NGQDs is aimed to bring an alternative to the traditional colorimetric Jaffe's reaction.


Assuntos
Grafite , Pontos Quânticos , Creatinina , Corantes Fluorescentes , Grafite/química , Humanos , Pontos Quânticos/química , Receptores Proteína Tirosina Quinases
3.
RSC Adv ; 11(55): 35028-35045, 2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-35494767

RESUMO

Amino acids are the noteworthy entity among biological molecules with diverse properties such as zwitterionic and amphoteric. Functionalizing carbon-based quantum dots using amino acids might be used for the extreme enhancement of electronic and optical properties of quantum dots and improve the performance of the resultant amino acid-functionalized quantum dots. The amino acid-functionalized quantum dots are highly soluble, sustainable, and biocompatible with virtuous optical and electrical performance, which makes them potential and suitable candidates for fabricating optoelectronic devices. The tenacity of using amino acids as functional groups to functionalize quantum dots and their novel properties are conferred to attain their multiple applications. The goal of this review is to provide the choices of amino acids based on the desired applications and a variety of functionalization techniques to make them a noteworthy material for future applications. The method of one-step and two-step functionalization strategies along with the properties of the resultant functionalized quantum dots and their plausible applications and future scope of the material are highlighted. Amidation is the basic principle behind the functionalization of quantum dots with amino acids. This review would be an exciting prospect to explore the pathways of the possible applications in different domains, in which the amino acid-functionalized quantum dots have not yet been explored. Further, this review article helps in pitching a variety of prominent applications right from sensors to energy storage systems either using the optical property or electronic property of amino acid-functionalized quantum dots.

4.
RSC Adv ; 10(61): 37409-37418, 2020 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-35521276

RESUMO

Trace determination of radioactive waste, especially Ce3+, by electrochemical methods has rarely been attempted. Ce3+ is (i) a fluorescence quencher, (ii) an antiferromagnet, and (iii) a superconductor, and it has been incorporated into fast scintillators, LED phosphors, and fluorescent lamps. Although Ce3+ has been utilized in many industries due to its specific properties, it causes severe health problems to human beings because of its toxicity. Nanomaterials with fascinating electrical properties can play a vital role in the fabrication of a sensor device to detect the analyte of interest. In the present study, surfactant-free 1,8-diaminonaphthalene (DAN)-functionalized graphene quantum dots (DAN-GQDs) with nanobud (NB) morphology were utilized for the determination of Ce3+ through electrochemical studies. The working electrode, graphene nanobud (GNB)-modified-carbon felt (CF), was developed by a simple drop-coating method for the sensitive detection of Ce3+ in acetate buffer solution (ABS, pH 4.0 ± 0.05) at a scan rate of 50 mV s-1 using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. CV and DPV studies validated the existence of distinctive peaks at approximately +0.20 and +0.93 V (vs. SCE), respectively, with a limit of detection of approximately 2.60 µM. Furthermore, electrochemical studies revealed that the GNB-modified-CF electrode was (i) stable even after fifteen cycles, (ii) reproducible, (iii) selective towards Ce3+, (iv) strongly pH-dependent, and (v) favored Ce3+ sensing only at pH 4.0 ± 0.05. Impedance spectroscopy results indicated that the GNB-modified-CF electrode was more conductive (1.38 × 10-4 S m-1) and exhibited more rapid electron transfer than bare CF, which agrees with the attained Randles equivalent circuit. Microscopy (AFM, FE-SEM, and HR-TEM), spectroscopy (XPS and Raman), XRD, and energy-dispersive X-ray (EDX) analyses of the GNB-modified-CF electrode confirmed the adsorption of Ce3+ onto the electrode surface and the size of the electrode material. Ce3+ nanobuds increased from 35-40 to 50-55 nm without changing their morphology. The obtained results provide an insight into the determination of Ce3+ to develop an electrochemical device with low sensitivity.

5.
J Am Acad Audiol ; 31(3): 185-194, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31304913

RESUMO

BACKGROUND: A community-based program for the comprehensive management of communication disorders among individuals with cleft lip and/or palate (CLP) was implemented in two rural districts in the state of Tamil Nadu, India. The program was successful in terms of early surgical repair, orthodontic management and speech correction; however, audiological surveillance was challenging due to poor follow-up rates. PURPOSE: The aim of the study was to compare tele-audiological and in-person audiological surveillance to identify the most beneficial approach for the identification and treatment of middle ear disease (MED) in individuals with CLP in this rural community-based program. RESEARCH DESIGN: Quasi-experimental study. STUDY SAMPLE: All beneficiaries older than 5 years actively seeking services in Cuddalore (n = 44) and Thiruvannamalai (n = 65) districts of Tamil Nadu, India, were included in the study. Individuals in Cuddalore district were assigned to the tele-audiological surveillance group, whereas individuals in Thiruvannamalai district were assigned to the in-person audiological surveillance group. METHODS: In the tele-audiological surveillance group, video-otoscopy examinations were performed by trained community-based rehabilitation workers (CBRWs). Pure-tone audiometry and tympanometry were performed by an audiologist from the tertiary care hospital through remotely accessed equipment using broadband internet at the participants' homes and monthly camps. Findings from those with suspected MED were forwarded to the otolaryngologist at the tertiary care hospital for remote diagnoses and treatment plans. Subsequently, CBRWs relayed the otolaryngologist's recommendations to the individuals receiving services at the community. In the in-person audiological surveillance group, video-otoscopy, pure-tone audiometry, and tympanometry were performed by the audiologist following standard testing procedures at monthly camps. Individuals with suspected MED and impacted cerumen were referred for in-person diagnoses and treatment plans. Follow-up audiological surveillance was conducted in both districts after implementation of the otolaryngologist's recommendations. DATA ANALYSIS: The coverage, follow-up rate for intervention and cost-outcomes from the provider's perspective were analyzed and compared between two groups. RESULTS: Tele-audiological surveillance provided superior coverage (68%) compared with in-person audiological surveillance (38%). The tele-audiological surveillance group showed greater follow-up compliance (61%) than the in-person audiological surveillance group (19%) for treatment plans such as cerumen management and hearing aid fitting provided locally. Compared with in-person audiological surveillance, tele-audiological surveillance resulted in cost saving of USD 47 per individual. CONCLUSION: Tele-audiological surveillance was beneficial for the purpose of identifying and providing treatment in patients having CLP with MEDs in rural locations.


Assuntos
Testes de Impedância Acústica/métodos , Audiologia/métodos , Audiometria de Tons Puros/métodos , Fenda Labial/complicações , Fissura Palatina/complicações , Transtornos da Audição/diagnóstico , Otoscopia/métodos , Telemedicina , Adolescente , Adulto , Criança , Transtornos da Comunicação/diagnóstico , Transtornos da Comunicação/etiologia , Otopatias/diagnóstico , Feminino , Transtornos da Audição/etiologia , Humanos , Índia , Masculino , Cooperação do Paciente , População Rural , Adulto Jovem
6.
ACS Appl Mater Interfaces ; 11(21): 19339-19349, 2019 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-31050885

RESUMO

Selective and sensitive detection of highly toxic chemicals by a suitable, fast, inexpensive, and trustworthy method is vital due to its serious health threats to humankind and breach of public security caused by unexpected terrorist attacks and industrial accidents. Phosgene or carbonyl dichloride is widely employed in many chemical industries and pharmaceuticals, and in pesticide production, which is extremely toxic by severe (short-term) inhalation exposure. Because of the non-existence of a phosgene sensor in aqueous solution and the immense emphasis gained by nanomaterials, especially carbonaceous materials, augmented attention has been given to the development of a fluorophore-functionalized carbon-based method to detect this noxious substance. In this study, surfactant free 1,8-diaminonaphthalene (DAN)-functionalized graphene quantum dots (DAN-GQDs) were prepared to detect phosgene in aqueous solution. The FESEM (field emission scanning electron microscopy) and HRTEM (high-resolution transmission electron microscopy) analyses confirm the as-prepared DAN-GQD morphology as nanobuds (NBs) with an average diameter of ca. 35-40 nm. The crystalline nature, elemental composition, and chemical state of DAN-GQDs were analyzed by standard physiochemical techniques. The edge-termination at the carboxyl functional group of GQDs with DAN was examined by XPS, Raman, FT-IR, and 1H NMR spectroscopy analyses. The aqueous solution of DAN-GQDs (4.89 × 10-9 M) exhibits a strong emission peak at 423 nm upon excitation at 328 nm. The addition of the phosgene molecule (0 → 88 µL) quenches the initial fluorescence intensity of DAN-GQDs (ΦF 53.6 → 34.6%) through the formation of a stable six-membered cyclized product. The DAN-GQDs displayed excellent selectivity and sensitivity for phosgene ( Ka = 3.84 × 102 M-1 and LoD (limit of detection) = 2.26 ppb) over other competing toxic pollutants in water. The time-resolved fluorescence analysis confirms that the quenching of DAN-GQDs follows nonradiative relaxation of excited electrons. Furthermore, bioimaging experiments of phosgene in living human breast cancer (HeLa) cells and cell viability test successfully demonstrated the practicability of DAN-GQDs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...