Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Cardiol ; 323: 288-291, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-32858138

RESUMO

BACKGROUND: COronaVIrus Disease 19 (COVID-19) led to the reorganization of Cardiology Units in terms of working spaces and healthcare personnel. In this scenario, both outpatient visits and elective interventional cardiology procedures were suspended and/or postponed. We aimed to report the impact of COVID-19 on interventional coronary and structural procedures in Piedmont, Italy. METHODS: The number of coronary angiographies (CAG), percutaneous coronary interventions (PCI), primary PCI (pPCI), transcatheter aortic valve replacements (TAVR) and Mitraclip performed in Piedmont between March 1st and April 20th, 2020 (CoV-time) were collected from each catheterization laboratory and compared to the number of procedures performed the year before in the same months (NoCoV-time). RESULTS: Procedural data from 18 catheterization laboratories were collected. Both coronary (5498 versus 2888: difference: -47.5%; mean 305.4 VS 160.4; p = 0.002) and structural (84 versus 17: difference: -79.8%; mean 4.7 Vs 0.9; p < 0.001) procedures decreased during CoV-time compared to NoCoV-time. In particular, coronary angiographies (1782 versus 3460), PCI (1074 versus 1983), p PCI (271 versus 410), TAVR (11 versus 72) and Mitraclip (6 versus 12) showed a reduction of 48.5%, 45.7%, 33.7%, 84.7% and 50.0%, respectively (all p for comparison <0.05). CONCLUSIONS: Compared to the same time-period in 2019, both coronary and structural interventional procedures during COVID-19 epidemic suffered a dramatic decrease in Piedmont, Italy. Organizational change and structured clinical pathways should be created, together with awareness campaigns.


Assuntos
COVID-19/epidemiologia , Angiografia Coronária/estatística & dados numéricos , Intervenção Coronária Percutânea/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Humanos , Itália/epidemiologia , Valva Mitral/cirurgia , Pandemias
2.
Can J Cardiol ; 36(7): 1152-1155, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32447060

RESUMO

The diffusion of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) forced the Italian population to restrictive measures that modified patients' responses to non-SARS-CoV-2 medical conditions. We evaluated all patients with acute coronary syndromes admitted in 3 high-volume hospitals during the first month of SARS-CoV-2 Italian-outbreak and compared them with patients with ACS admitted during the same period 1 year before. Hospitalization for ACS decreased from 162 patients in 2019 to 84 patients in 2020. In 2020, both door-to-balloon and symptoms-to-percutaneous coronary intervention were longer, and admission levels of high-sensitive cardiac troponin I were higher. They had a lower discharged residual left-ventricular function and an increased predicted late cardiovascular mortality based on their Global Registry of Acute Coronary Events (GRACE) scores.


Assuntos
Síndrome Coronariana Aguda/terapia , Infecções por Coronavirus/epidemiologia , Pandemias/estatística & dados numéricos , Intervenção Coronária Percutânea/estatística & dados numéricos , Pneumonia Viral/epidemiologia , Sistema de Registros , Tempo para o Tratamento/estatística & dados numéricos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/mortalidade , Adulto , Idoso , COVID-19 , Estudos de Coortes , Surtos de Doenças/estatística & dados numéricos , Feminino , Mortalidade Hospitalar/tendências , Hospitalização/estatística & dados numéricos , Hospitais com Alto Volume de Atendimentos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Medição de Risco , Estatísticas não Paramétricas , Taxa de Sobrevida , Resultado do Tratamento
3.
J Thorac Dis ; 9(Suppl 9): S986-S993, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28894605

RESUMO

Bioresorbable vascular scaffold (BRS) represent a revolutionary concept in interventional cardiology. After initial enthusiasm, recent real world registries, including patients with increasing lesion complexity, reported not trivial rates of scaffold thrombosis (ScT). The importance of correct patients selection as well as technical aspects during BRS implantation procedures has been highlighted in several studies suggesting that the high rate of ScT might be related to uncorrected patients/lesions selection together with underutilization of intracoronary imaging guidance leading to suboptimal BRS implantation. The high-resolution power together with the lack of shadowing observed beyond polymer struts makes optical coherence tomography (OCT) the optimal imaging technique to guide BRS implantation and identifies eventually scaffolds failures.

4.
Eur J Cardiothorac Surg ; 50(6): 1139-1148, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27406375

RESUMO

OBJECTIVES: The aim of this multicentre study is to report the clinical experiences of all patients undergoing transcatheter aortic valve implantation (TAVI) with a balloon-expandable device in Italy. METHODS: The Italian Transcatheter balloon-Expandable valve Registry (ITER) is a real-world registry that includes patients who have undergone TAVI with the Sapien (Edwards Lifesciences, Irvine, CA, USA) bioprosthesis in Italy since it became available in clinical practice. From 2007 to 2012, 1904 patients were enrolled to undergo TAVI in 33 Italian centres. Outcomes were classified according to the updated Valve Academic Research Consortium (VARC-2) definitions. A multivariable analysis was performed to identify independent predictors of all-cause mortality. RESULTS: Mean age was 81.7 (SD:6.2) years, and 1147 (60.2%) patients were female. Mean Logistic EuroSCORE was 21.1% (SD:13.7). Transfemoral, transapical, transaortic and transaxillary TAVI was performed in 1252 (65.8%), 630 (33.1%), 18 (0.9%) and 4 (0.2%) patients, respectively. Operative mortality was 7.2% (137 patients). The VARC-2 outcomes were as follows: device success, 88.1%; disabling stroke, 1.0%; life-threatening and major bleeding 9.8 and 10.5%, respectively; major vascular complication, 9.7%; acute kidney injury, 8.2%; acute myocardial infarction ≤72 h, 1.5%. Perioperative pacemaker implantation was necessary in 116 (6.1%) patients. At discharge, the mean transprosthetic gradient was 10.7 (SD:4.5) mmHg. Incidence of postoperative mild, moderate or severe paravalvular leak was, respectively, 32.1, 5.0 and 0.4%. A total of 444/1767 (25.1%) deaths after hospital discharge were reported: of these, 168 (37.8%) were classified as cardiac death. Preoperative independent predictors of all-cause mortality were male gender (HR: 1.395; 95% CI:1.052-1.849); overweight, BMI 25-30 kg/m2 (HR: 0.775; 95% CI: 0.616-0.974); serum creatinine level (every 1 mg/dl increase; HR: 1.314; 95% CI:1.167-1.480); haemoglobin level (every 1 g/dl increase; HR: 0.905; 95% CI:0.833-0.984); critical preoperative state (HR: 2.282; 95% CI: 1.384-3.761); neurological dysfunction (HR: 1.552; 95% CI:1.060-2.272); atrial fibrillation (HR: 1.556; 95% CI:1.213-1.995); pacemaker rhythm (HR: 1.948; 95% CI:1.310-2.896); NYHA Class III or IV (HR: 1.800; 95% CI:1.205-2.689 or HR: 2.331; 95% CI:1.392-3.903, respectively). CONCLUSIONS: TAVI with a balloon-expandable device in the 'real world' shows good mid-term outcomes in terms of survival, technical success, valve-related adverse events and haemodynamic performance.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Itália , Masculino , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...