Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cell Mol Biol (Noisy-le-grand) ; 55(3): 1-6, 2009 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-20003804

RESUMO

Several methods can be used to determine the activity of (131)I in the treatment of hyperthyroidism. However, many of them do not consider all the parameters necessary for optimum dose calculation. The relationship between the dose absorbed by the thyroid and the activity administered depends basically on three parameters: organ mass, iodine uptake and effective half-life of iodine in the thyroid. Such parameters should be individually determined for each patient in order to optimize the administered activity. The objective of this work is to develop a methodology for individualized treatment with (131)I in patients with hyperthyroidism of the Grave's Disease. A neck-thyroid phantom developed at the IRD was used to calibrate a scintillation camera and a uptake probe SCT-13004 at the Nuclear Medicine Center of the University Hospital of Rio de Janeiro and a uptake probe SCT-13002, available at the Nuclear Medicine Institute in Goiânia. The biokinetic parameters were determined based on measurements performed in eight voluntary patients. It is concluded that the use of the equipment available at the hospital (scintillation camera and uptake probe) has shown to be a suitable and feasible procedure for dose optimization in terms of effectiveness, simplicity and cost.


Assuntos
Hipertireoidismo/tratamento farmacológico , Radioisótopos do Iodo/uso terapêutico , Medicina Nuclear , Câmaras gama , Doença de Graves/tratamento farmacológico , Humanos , Radioisótopos do Iodo/efeitos adversos , Radioisótopos do Iodo/metabolismo , Medicina Nuclear/instrumentação , Medicina Nuclear/métodos , Dosagem Radioterapêutica
2.
Radiat Prot Dosimetry ; 127(1-4): 465-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17681960

RESUMO

The manipulation of a wide variety of unsealed sources in Nuclear Medicine results in a significant risk of internal exposure of the workers. 131I should be highlighted among the most frequently used radionuclides because of its large application for diagnosis and therapy of thyroid diseases. The increasing use of radionuclides for medical purposes creates a demand for feasible methodologies to perform occupational control of internal contamination. Currently in Brazil, there are approximately 300 nuclear medicine centres in operation but individual monitoring is still restricted to the control of external exposure. This work presents the development of in vivo and in vitro bioassay techniques aimed to quantify incorporation of radionuclides used in Nuclear Medicine. It is also presented the results of a preliminary survey of internal exposure of a group of workers involved in the preparation of therapeutic doses of 131I. Workers were monitored with a gamma camera available in the Nuclear Medicine Service of the University Hospital of Rio de Janeiro and at the Institute of Radiation Protection and Dosimetry Whole-Body Counter (IRD-WBC). The in vivo detection systems were calibrated with a neck-thyroid phantom developed in IRD. Urine samples from radiopharmacy workers were collected after preparation and administration of therapeutic doses (10-250 mCi) of 131I and measured with a HPGe detection system available in the Bioassay Laboratory of IRD. The results show that the bioassay methods developed in this work present enough sensitivity for routine monitoring of nuclear medicine workers. All workers monitored in this survey presented positive results for 131I in urine samples and two workers presented detectable activities in thyroid when measured at the IRD-WBC. The highest committed effective dose per preparation was estimated to be 17 microSv.


Assuntos
Bioensaio/métodos , Carga Corporal (Radioterapia) , Pessoal de Saúde , Modelos Biológicos , Radiometria/métodos , Brasil , Simulação por Computador , Humanos , Medicina Nuclear , Doses de Radiação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Radiat Prot Dosimetry ; 127(1-4): 253-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17562649

RESUMO

The concern about accidents involving radioactive materials has led to the search of alternative methods to quickly identify and quantify radionuclides in workers and in the population. One of the options to face up an eventual demand for mass monitoring of internal contamination is the use of a nuclear medicine diagnostic equipment known as gamma camera, a device used to scan patients who have been administered specific amounts of radioactive materials for medical purposes. Although the gamma camera is used for image diagnosis, it can be calibrated with anthropomorphic phantoms or point sources for the quantification of radionuclide activities in the human body. This work presents a protocol for the calibration of gamma cameras for such application. In order to evaluate the suitability of this type of equipment, a gamma camera available in a public hospital located in Rio de Janeiro was calibrated for the in vivo measurement of 131I. The calibration includes the determination of detection efficiencies and minimum detectable activities for each radionuclide. The results show that the gamma camera presents enough sensitivity to detect activity levels corresponding to effective doses below 1 mSv. The protocol is the basis to establish a network of Nuclear Medicine Centres, located in public hospitals in eight countries of Latin America (Argentina, Brazil, Colombia, Cuba, Chile, Mexico, Peru and Uruguay) and in Spain that could be requested to collaborate in remediation actions in the event of an accident involving incorporation of radioactive materials. This protocol is one of the most significant outputs of the IAEA-ARCAL Project (RLA/9/049-LXXVIII) aimed to the Harmonization of Internal Dosimetry Procedures.


Assuntos
Algoritmos , Emergências , Câmaras gama/normas , Radioisótopos/análise , Contagem Corporal Total/instrumentação , Contagem Corporal Total/normas , Calibragem , Internacionalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...