Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
1.
J Am Soc Echocardiogr ; 37(5): 530-537, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38341053

RESUMO

BACKGROUND: Data on the prognostic factors after mitral valve (MV) transcatheter edge-to-edge repair (TEER; MV-TEER) are limited. Pulsed-wave Doppler interrogation of pulmonary vein flow (PVF) is a convenient method to assess the hemodynamic burden of residual mitral regurgitation (MR), which could be of utility as a predictor of outcomes. METHODS: Patients that underwent MV-TEER between May 2014 and December 2021 at our institution were evaluated. Pulmonary vein flow patterns post-MV-TEER were reviewed on the procedural transesophageal echocardiogram and classified as normal (systolic dominant or codominant) or abnormal (systolic blunting or reversal). The PVF pattern was correlated with all-cause mortality at follow-up. RESULTS: Two-hundred sixty-five patients had diagnostic PVF post-MV-TEER, with 73 (27.5%) categorized as normal and 192 (72.5%) categorized as abnormal. Patients with abnormal PVF morphology were more likely to have atrial fibrillation (70% vs 42%, P < .001) and greater than moderate residual MR (16% vs 3%, P = .01) and had higher mean left atrial pressure (18.1 ± 5.0 vs 15.9 ± 4.2 mm Hg, P = .002) and left atrial V wave (26.6 ± 8.5 vs 21.4 ± 7.3 mm Hg, P < .001) postprocedure. In multivariable analysis, abnormal PVF morphology post-MV-TEER was independently associated with mortality at follow-up (hazard ratio = 1.70; 95% CI, 1.06-2.74; P = .03) after correction for end-stage renal disease, atrial fibrillation, and residual MR. Results were similar in subgroups of patients with moderate or less and those with mild or less residual MR. CONCLUSIONS: Pulmonary vein flow morphology is a simple and objective tool to assess MR severity immediately post-MV-TEER and offers important prognostic information to optimize procedural results. Additional studies are needed to determine whether patients with abnormal PVF pattern post-MV-TEER would benefit from more intensive goal-directed medical therapy postprocedure.


Assuntos
Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral , Valva Mitral , Veias Pulmonares , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Masculino , Feminino , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Idoso , Ecocardiografia Transesofagiana/métodos , Cateterismo Cardíaco/métodos , Estudos Retrospectivos , Taxa de Sobrevida , Prognóstico , Ecocardiografia Doppler de Pulso/métodos
2.
J Am Coll Cardiol ; 81(24): 2361-2373, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37316116

RESUMO

Pulmonary vein stenosis (PVS) can arise from several etiologies, including congenital, acquired, and iatrogenic sources. PVS presents insidiously, leading to significant delays in diagnosis. A high index of suspicion and dedicated noninvasive evaluation are key to diagnosis. Once diagnosed, both noninvasive and invasive evaluation may afford further insights into the relative contribution of PVS to symptoms. Treatment of underlying reversible pathologies coupled with transcatheter balloon angioplasty and stenting for persistent severe stenoses are established approaches. Ongoing refinements in diagnostic modalities, interventional approaches, postintervention monitoring, and medical therapies hold promise to further improve patient outcomes.


Assuntos
Angioplastia com Balão , Estenose de Veia Pulmonar , Humanos , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/terapia , Constrição Patológica/diagnóstico , Constrição Patológica/etiologia , Constrição Patológica/terapia , Stents
4.
JACC Clin Electrophysiol ; 8(10): 1323-1333, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36117046

RESUMO

Pulmonary vein stenosis (PVS) may arise from a variety of conditions and result in major morbidity and mortality. In some patients, pharmacologic therapy may help, but more often in advanced stages, mechanical treatment must be considered. Transcatheter approaches, both balloon angioplasty (BA) and stent implantation, have been applied. Although both are effective, they continue to be limited by restenosis. In this systematic review and meta-analysis, Ovid MEDLINE, Ovid Embase, Ovid Cochrane Central Register of Controlled Trials, Ovid Cochrane Database of Systematic Reviews, and Scopus were searched for English-language studies in humans published between January 1, 2010, and August 2, 2021. Two independent reviewers screened for studies in which BA or stenting was performed for PVS with reporting of restenosis outcomes, and data were independently extracted. A systematic review was performed, and overall restenosis rates were reported across all 34 included studies. Meta-analysis was then performed using RevMan version 5.4, assessing rates of restenosis and restenosis requiring reintervention in those studies with available data reported. For restenosis rates, 4 studies treated a total of 340 patients with 579 pulmonary vein interventions (225 with BA and 354 with stenting, mean follow-up 13-69 months). Restenosis requiring repeat intervention was reported in 3 studies, including 301 patients with 495 pulmonary vein interventions (157 with BA and 338 with stenting). Compared with BA, stenting was associated with both a lower risk for restenosis (risk ratio: 0.36; 95% CI: 0.18-0.73; P = 0.005) and a lower risk for restenosis requiring reintervention (RR: 0.36; 95% CI: 0.15-0.86; P = 0.02). For PVS intervention, restenosis and reintervention rates may be improved by stent implantation compared with BA.


Assuntos
Angioplastia com Balão , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Estenose de Veia Pulmonar/cirurgia , Estenose de Veia Pulmonar/etiologia , Angioplastia com Balão/efeitos adversos , Stents/efeitos adversos , Veias Pulmonares/cirurgia , Constrição Patológica/cirurgia
5.
Catheter Cardiovasc Interv ; 100(1): 133-142, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35535629

RESUMO

BACKGROUND: Mitral transcatheter edge-to-edge repair (MTEER) is an established therapeutic approach for mitral regurgitation (MR). Functional mitral regurgitation originating from atrial myopathy (A-FMR) has been described. OBJECTIVES: We sought to assess the clinical, echocardiographic and hemodynamic considerations in A-FMR patients undergoing MTEER. METHODS: From 2014 to 2020, patients undergoing MTEER for degenerative MR (DMR), functional MR (FMR), and mixed MR were assessed. A-FMR was defined by the presence of MR > moderate in severity; left ventricular (LV) ejection fraction (LVEF) ≥ 50%; and severe left atrial (LA) enlargement in the absence of LV dysfunction, leaflet pathology, or LV tethering. The diagnosis of A-FMR (vs. ventricular-FMR [V-FMR]) was confirmed by three independent echocardiographers. Baseline characteristics, procedural outcomes as well as clinical and echocardiographic follow-up are reported. Device success was defined as final MR grade ≤ moderate; MR reduction ≥1 grade; and final transmitral gradient <5 mmHg. RESULTS: 306 patients underwent MTEER, including DMR (62%), FMR (19%), and mixed MR (19%). FMR cases included 37 (63.8%) V-FMR and 21 (36.2%) A-FMR. Tricuspid regurgitation (≥ moderate) was higher in A-FMR (80.1%) compared to V-FMR (54%) and DMR (42%). Device success did not significantly differ between A-FMR and V-FMR (57% vs. 73%, p = 0.34) or DMR (57% vs. 64%, p = 1.0). The A-FMR cohort was less likely to achieve ≥3 grades of MR reduction compared to V-FMR (19% vs. 54%, p = 0.01) and DMR (19% vs. 49.7%, p = 0.01). Patients with V-FMR and DMR demonstrated significant reductions in mean left atrial pressure (LAP) and peak LA V-wave, though A-FMR did not (LAP -0.24 ± 4.9, p = 0.83; peak V-wave -1.76 ± 9.1, p = 0.39). In follow-up, echocardiographic and clinical outcomes were similar. CONCLUSIONS: In patients undergoing MTEER, A-FMR represents one-third of FMR cases. A-FMR demonstrates similar procedural success but blunted acute hemodynamic responses compared with DMR and V-FMR following MTEER. Dedicated studies specifically considering A-FMR are needed to discern the optimal therapeutic approaches.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 99(6): 1807-1816, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35066988

RESUMO

OBJECTIVES: To compare all-cause mortality in patients with mitral annulus calcification (MAC) and severe mitral valve dysfunction (MVD) who received standard mitral intervention versus no intervention. BACKGROUND: Patients with MAC often have high surgical risk due to advanced age, comorbidities, and technical challenges related to calcium. The impact of a mitral intervention on outcomes of patients with MAC and severe MVD is not well known. METHODS: Retrospective review of patients with MAC by transthoracic echocardiography (TTE) in 2015 at a single institution. Patients with severe mitral stenosis (MS) or regurgitation (MR) were analyzed and stratified into two groups: surgical or transcatheter intervention performed <1 year after the index TTE, and no or later intervention. The primary endpoint was all-cause mortality. RESULTS: Of 5502 patients with MAC, 357 had severe MVD (MS = 27%, MR = 73%). Of those, 108 underwent mitral intervention (surgery = 87; transcatheter = 21). They were younger (73 ± 11 vs. 76 ± 11 years, p < 0.01) and less frequently had cardiovascular diseases compared with no-intervention. Frequency in women was similar (45% vs. 50%, p = 0.44). During median follow-up of 3.2 years, the intervention group had higher estimated survival than those without intervention (80% vs. 72% at 1 year and 55% vs. 35% at 4 year, p < 0.01). Adjusted for age, eGFR, LVEF < 50%, and pulmonary hypertension, mitral intervention was an independent predictor of lower mortality (hazard ratio = 0.66, 95% confidence interval 0.43-0.99, p = 0.046). CONCLUSION: Patients with MAC and severe MVD who underwent mitral intervention <1 year from index TTE had lower mortality than those without intervention. Mitral intervention was independently associated with lower mortality.


Assuntos
Calcinose , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Feminino , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Estudos Retrospectivos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 98(6): E932-E937, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34245208

RESUMO

BACKGROUND: The predictors and clinical significance of increased Doppler-derived mean diastolic gradient (MG) following transcatheter edge-to-edge mitral valve repair (MVTEER) remain controversial. OBJECTIVE: We sought to examine baseline correlates of Doppler-derived increased MG post-MVTEER and its impact on intermediate-term outcomes. METHODS: Patients undergoing MVTEER were analyzed retrospectively. Post-MVTEER increased MG was defined as >5 mmHg or aborted clip implantation due to increased MG intraprocedurally. Baseline MG and 3D-guided mitral valve area (MVA) by planimetry were retrospectively available in 233 and 109 patients. RESULTS: 243 patients were included; 62 (26%) had MG > 5 mmHg post-MVTEER or aborted clip insertion, including 7 (11%) that had aborted clip implantation. Mortality occurred in 63 (26%) during a median follow up of 516 days (IQR 211, 1021). Increased post-MVTEER MG occurred more frequently in females (44% vs. 16%, p < 0.001), those with baseline MVA <4.0 cm2 (71% vs. 16%), baseline MG ≥4 mmHg (61% vs. 20%), or multiple clips implanted (33% vs. 21%, p = 0.04). Increased post-MVTEER MG was associated with increased subsequent mortality compared to those with normal gradient (HR 1.91 95% CI 1.15-3.18 p = 0.016) as was aborted clip insertion compared to all others (HR 5.23 95% CI 2.06-13.28 p < 0.001). CONCLUSIONS: Smaller baseline MVA and increased baseline MG are associated with increased MG post-MVTEER and patients with a Doppler-derived post-MVTEER MG >5 mmHg suffered excess subsequent mortality. In high risk patients considered for MVTEER, identification of those at risk of iatrogenic mitral stenosis with MVTEER is important as they may be optimally treated with alternate surgical or transcatheter therapies.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
9.
Mayo Clin Proc ; 96(5): 1356-1362, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33958063

RESUMO

Patients with patent foramen ovale can manifest in a variety of ways. These presentations and their resolution are discussed in this article.


Assuntos
Forame Oval Patente/diagnóstico , Forame Oval Patente/terapia , Adulto , Idoso , Feminino , Forame Oval Patente/complicações , Humanos , Masculino , Pessoa de Meia-Idade
10.
Int J Cardiol Heart Vasc ; 33: 100765, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33889711

RESUMO

AIMS: Percutaneous mitral balloon valvotomy PMBV is an acceptable alternative to Mitral valve surgery for patients with mitral stenosis. The purpose of this study was to explore the immediate results of PMBV with respect to echocardiographic changes, outcomes, and complications, using a meta-analysis approach. METHODS: MEDLINE, and EMBASE databases were searched (01/2012 to 10/2018) for original research articles regarding the efficacy and safety of PMBV. Two reviewers independently screened references for inclusion and abstracted data including article details and echocardiographic parameters before and 24-72 h after PMBV, follow-up duration, and acute complications. Disagreements were resolved by third adjudicator. Quality of all included studies was evaluated using the Newcastle-Ottawa Scale NOS. RESULTS: 44/990 references met the inclusion criteria representing 6537 patients. Our findings suggest that PMBV leads to a significant increase in MVA (MD = 0.81 cm2; 0.76-0.87, p < 0.00001), LVEDP (MD = 1.89 mmHg; 0.52-3.26, p = 0.007), LVEDV EDV (MD = 5.81 ml; 2.65-8.97, p = 0.0003) and decrease in MPG (MD = -7.96 mmHg; -8.73 to -7.20, p < 0.00001), LAP (MD = -10.09 mmHg; -11.06 to -9.12, p < 0.00001), and SPAP (MD = -15.55 mmHg; -17.92 to -13.18, p < 0.00001). On short term basis, the pooled overall incidence estimates of repeat PMBV, mitral valve surgery, post-PMBV severe MR, and post-PMBV stroke, and systemic thromboembolism were 0.5%, 2%, 1.4%, 0.4%, and 0.7%% respectively. On long term basis, the pooled overall incidence estimates of repeat PMBV, mitral valve surgery, post-PMBV severe MR, and post-PMBV stroke, systemic thromboembolism were 5%, 11.5%, 5.5%, 2.7%, and 1.7% respectively. CONCLUSION: PMBV represents a successful approach for patients with mitral stenosis as evidenced by improvement in echocardiographic parameters and low rate of complications.

11.
J Am Soc Echocardiogr ; 34(6): 595-603.e2, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33524491

RESUMO

BACKGROUND: Iatrogenic mitral stenosis is a known limitation of transcatheter edge-to-edge mitral valve repair (TMVr), but determinants of increased postprocedural mean diastolic gradient (MG) are not well defined. The aim of this study was to determine correlates of increased post-TMVr MG or aborted clip implantation due to increased MG. METHODS: Procedural three-dimensional transesophageal echocardiographic (TEE) data sets of 112 patients who underwent TMVr were retrospectively analyzed. Three-dimensional TEE mitral valve area (MVA) planimetry and mitral annular calcification (MAC) were quantified using multiplanar reconstruction. When MAC extension into the mitral leaflets was present, MAC with leaflet calcification (MAC-LC) length was recorded as the maximum distance from the mitral annulus to the most distal leaflet calcification. Increased MG after TMVr, measured on intraprocedural TEE imaging, was defined as ≥5 mm Hg or aborted clip implantation due to increased MG. RESULTS: Baseline MVA was 5.9 ± 1.7 cm2, baseline MG was 2.1 ± 1.2 mm Hg, and MAC-LC length was 4.0 ± 4.5 mm. Thirty-two patients (29%) had increased post-TMVr MG. Risk for increased post-TMVr MG was 86%, 28%, and 14% in patients with baseline MVA < 4.0, 4.0 to 6.0, and >6.0 cm2, respectively (P < .001). In patients with baseline MVA 4.0 to 6.0 cm2, concurrent baseline MG ≥ 4 mm Hg or MAC-LC ≥ 6 mm was associated with higher risk for increased post-TMVr MG (53% vs 12%, P = .002). In patients with baseline MVA < 4.0 and >6.0 cm2, the risk for increased post-TMVr MG was similar in the presence or absence of baseline MG ≥ 4 mm Hg or MAC-LC ≥ 6 mm (P > .05 for both). CONCLUSIONS: Patients with baseline three-dimensional TEE MVA < 4.0 cm2 are at high risk for increased post-TMVr MG. Additionally, patients with borderline MVA (4.0-6.0 cm2) and concurrent MAC-LC length ≥ 6 mm or baseline MG ≥ 4 mm Hg are at moderate risk for increased MG after TMVr.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 97(1): E79-E87, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32259389

RESUMO

OBJECTIVES: We sought to determine hemodynamic effects of aortic paravalvular leak (PVL) and predictors of clinical outcomes after aortic PVL closure. BACKGROUND: The significance of hemodynamic alterations in PVL and relation to severity, procedural success of percutaneous closure and clinical outcomes have not been defined. METHODS: Patients undergoing percutaneous PVL closure between July 21, 2004 and September 10, 2018 were included. PVL severity was assessed by echocardiography and aortic angiography. Hemodynamics were assessed by intra-arterial pressure tracings before and after PVL closure. The primary outcome was a composite of mortality, redo aortic valve replacement (AVR) and redo PVL closure. RESULTS: One hundred and seventeen patients (mean age 70.3 ± 14.9 years, 79% surgical and 21% transcatheter prostheses) underwent PVL closure with 94% technical success. PVL was moderate or greater in 106 (91%) at baseline and 11 (11%) post-procedure. Diastolic BP for those with moderate or greater PVL was lower than for those with less PVL (50.3 ± 11.7 vs. 56.5 ± 12.4 mmHg, p < .001). Pulse pressure was similar between these groups (69.9 ± 20.3 vs. 67.4 ± 21.2 mmHg, p = .39). 35 patients (34%) had 40 events during a mean follow-up of 1.6 ± 1.9 years (23 deaths, 12 redo AVR, and five redo PVL closures). In a multivariate model, final diastolic BP <47 mmHg (HR 3.27 [1.45-7.36], p = .007) was a significant predictor of the composite endpoint. CONCLUSIONS: Diastolic BP was significantly associated with aortic PVL severity and clinical outcomes after PVL closure. In contrast, pulse pressure did not correlate with PVL severity or outcomes. These findings have implications for clinical management of patients with aortic PVL.


Assuntos
Insuficiência da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Pressão Sanguínea , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 96(6): 1323-1330, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32180349

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair with MitraClip is only approved for treatment of mitral regurgitation but is increasingly used to treat concomitant tricuspid regurgitation (TR) due to its common coexistence and association with poor outcomes. This study aimed to describe the learning curve associated with the challenge of off-label treatment of concomitant TR. METHODS: This is a retrospective review of initial and consecutive patients who underwent combined edge-to-edge repair of mitral and tricuspid valves (TVs) at our institution from August 2017 to October 2019. RESULTS: Repair of both valves with MitraClip was performed in 22 patients (median age 81.5 years, 32% female). Mean procedure time was 176 ± 47 min; mean fluoroscopy time was 65 ± 24 min. Procedure duration in the first tertile was significantly longer (223 ± 13 min) than in the third tertile (143 ± 23 min, p = .0003). Median number of total clips placed per case was 3; in 15 patients (68%), the anterior and septal leaflets of the TV were clipped. The average changes in mean right atrial (RA) and left atrial (LA) pressures were -1.7 ± 2.5 mmHg (p = .0080) and -3.2 ± 4.6 mmHg (p = .0045), respectively. The average changes in RA and LA V-wave heights were -3.3 ± 4.0 mmHg (p = .0009) and -8.1 ± 9.9 mmHg (p = .038), respectively. There was a significant trend toward decreasing residual TR over the course of the series (p = .046). At 30 days, survival was 100% and mean NYHA class decreased from 2.8 to 1.8 (p < .0001). CONCLUSIONS: Combined edge-to-edge tricuspid and mitral valve repair is safe and feasible. With experience, procedure duration and residual TR decreased.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Curva de Aprendizado , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Duração da Cirurgia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
14.
Heart ; 106(12): 898-903, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31980440

RESUMO

OBJECTIVE: A subset of patients at the time of transcatheter mitral valve repair (TMVR) will have normal left atrial pressure (LAP) (<13 mm Hg) despite having severe mitral regurgitation (MR). The goal of this study was to determine clinical characteristics and outcomes in patients with normal LAP undergoing TMVR. METHODS: A single-centre retrospective cohort of consecutive patients who underwent transcatheter edge-to-edge mitral valve clip and continuous LAP monitoring between 5/1/2014 and 5/1/2018 was analysed. One-year mortality was compared by Kaplan-Meier survival curves. Multivariable analysis was performed to identify predictors of normal LAP and 1 year mortality. RESULTS: Of the 204 patients undergoing TMVR, 65% were men and the mean age was 81. Of these patients, 31 (15%) had normal LAP (mean LAP 10.5 mm Hg, mean V wave 16.5 mm Hg) and 173 had elevated LAP (mean LAP 19 mm Hg, mean V wave 32.5 mm Hg). The prevalence of severe MR was not different between groups, although the normal LAP group had significantly lower effective regurgitant orifice area and regurgitant volume. Other notable baseline characteristics including prior cardiac surgery, atrial fibrillation, hypertension, diabetes, congestive heart failure, body mass index, mechanism of MR and ejection fraction were similar between groups. However, there was an increased prevalence of chronic lung disease (CLD) (45.2% vs 17.3%, p<0.001) in the normal LAP group. On multivariate analysis, the only significant predictor of normal LAP was the presence of CLD (OR 4.79 (1.83-12.36), p=0.001) and 1-year mortality was significantly higher in the normal LAP group (32.3% vs 12.7%, p=0.006). After adjustment for comorbidities, normal LAP was no longer a predictor of 1-year mortality (RR 1.62 (0.64-4.06), p=0.32); however, CLD (RR 3.44 (1.37-8.67), p=0.01) remained a statistically significant predictor. CONCLUSION: Normal LAP at the time of TMVR is associated with a higher incidence of CLD which independently predicts increased 1-year mortality. In patients with CLD and apparently severe MR, measurement of LAP may help identify those with lower likelihood of benefit from TMVR.


Assuntos
Função do Átrio Esquerdo , Pressão Atrial , Cateterismo Cardíaco , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Feminino , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
15.
J Invasive Cardiol ; 31(10): E306-E307, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31567123

RESUMO

Aortic paravalvular leak (PVL) is a known complication of TAVR. PVL closure using vascular occluder devices can be used, particularly in cases with annular calcification preventing adequate seal; however, delivery of equipment can be challenging in TAVR patients due to interaction with the valve stent. We describe a novel antegrade closure approach to treat transcatheter aortic PVL.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Falha de Prótese , Reoperação , Dispositivos de Acesso Vascular
16.
J Am Soc Echocardiogr ; 32(11): 1426-1435.e1, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31466850

RESUMO

BACKGROUND: Patient selection for transcatheter edge-to-edge mitral valve repair (TMVR) remains challenging because of heterogenous mitral valve pathology and highly variable anatomy. The aim of this study was to investigate whether quantitative three-dimensional (3D) transesophageal echocardiographic modeling parameters are associated with optimal mitral regurgitation (MR) reduction in patients undergoing TMVR. METHODS: Fifty-nine patients underwent 3D transesophageal echocardiography during TMVR. Volumetric data sets were retrospectively analyzed using mitral valve quantitative 3D modeling software (Mitral Valve Navigator). Optimal MR reduction was defined as less than moderate residual MR. Logistic regression was used to correlate 3D transesophageal echocardiographic quantitative data to procedural success. RESULTS: Thirty-five patients had primary MR, 24 had mixed or secondary MR, and all patients had grade ≥ 3/4 MR before the procedure. Optimal MR reduction was achieved in 40 of 59 patients (68%). Univariate correlates of optimal MR reduction in patients with primary MR were lower mitral leaflet tenting volume (P = .049) and lower tenting height (P = .025); tenting height < 3 mm and tenting volume < 0.7 mL were associated with increased likelihood of optimal MR reduction (92% vs 48% [P = .01] and 81% vs 47% [P = .03], respectively). In mixed or secondary MR, annular height ≥ 5.5 mm was associated with increased likelihood of optimal MR reduction (94% vs 38%; P = .03). During follow-up, redo TMVR or surgical mitral valve replacement occurred exclusively in patients with suboptimal anatomy defined by 3D transesophageal echocardiography (10% vs 0%, P = .045). CONCLUSIONS: Quantitative 3D echocardiographic data are associated with favorable response to TMVR and could help optimize patient selection.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Monitorização Intraoperatória/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 93(6): 1069-1075, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30747481

RESUMO

OBJECTIVE: To review our experience with balloon testing prior to atrial septal defect (ASD) closure in adults with left ventricular (LV) diastolic dysfunction. BACKGROUND: ASD closure in patients with LV diastolic dysfunction may precipitate LV failure. Temporary ASD occlusion has been used in this scenario but data are limited. METHODS: Retrospective review of 27 patients age ≥ 50 years undergoing temporary ASD balloon occlusion between 2000 and 2018 for suspected LV diastolic dysfunction or elevated LV end-diastolic pressure (LVEDP). RESULTS: Median age was 72 years (IQR 66.7; 75.2). Atrial fibrillation was seen in 58% of patients, hypertension in 58%, and coronary artery disease in 26%; 52% were females. Median ASD size was 13 mm (10; 18) and Qp/Qs 1.8 (1.6; 2.2). Median LVEDP was 14 mmHg (12; 22); pulmonary artery wedge pressure (PAWP) 12 mmHg (9; 16.5) and left atrial pressure (LAP) 13.5 mmHg (8; 16.3). After a median of 5 min (3; 10) of balloon occlusion, patients with baseline LVEDP ≥15 mmHg had more significant increases in LVEDP (9 [6; 12] vs. 2 mmHg [0.5; 5]; p = 0.03) and LAP/PAWP (10.5 [8.3; 16.3] vs. 1.5 mmHg [-1.5; 3]; p = 0.0003) than those with baseline LVEDP <15 mmHg. None of those with a baseline LVEDP <15 mmHg had a LAP/PAWP >15 mmHg during balloon testing compared to 92% of patients with a baseline LVEDP ≥15 mmHg. CONCLUSION: LVEDP might be used to predict LAP post-ASD closure. Comorbidities typically associated with LV diastolic dysfunction are common in these patients and should be considered in their management.


Assuntos
Oclusão com Balão , Comunicação Interatrial/diagnóstico , Hemodinâmica , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Idoso , Diástole , Feminino , Comunicação Interatrial/complicações , Comunicação Interatrial/fisiopatologia , Comunicação Interatrial/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Direita , Pressão Ventricular
19.
Mayo Clin Proc ; 94(1): 89-102, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30611459

RESUMO

Recent innovations and advancements in 3-dimensional (3D) echocardiography allow for better understanding of anatomic relationships and improve communication with the interventional cardiologist for guidance of catheter-based interventions. The mitral valve lends itself best for imaging with transesophageal echocardiography (TEE). Consequently, the role of 3D TEE in guiding catheter-based mitral interventions has been evolving rapidly. Although several publications have reported on the advantages and role of 3D TEE in guiding one or more of the steps involved in percutaneous mitral valve repair using the MitraClip, none offer a comprehensive and practical user-friendly guide. This review article provides the reader with practical intraprocedural tips on use of 3D TEE to guide all relevant steps involved in the procedure including how to acquire the images needed and what to look for.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Guias de Prática Clínica como Assunto
20.
Catheter Cardiovasc Interv ; 94(5): 738-744, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30688003

RESUMO

BACKGROUND: The effect of utilizing transapical (TA) access for transcatheter aortic valve replacement (TAVR) on cardiac function has not been well studied. AIMS: The aim of this retrospective study is to determine the direct effects of TA access for TAVR on myocardial function parameters and their correlation with 4-year survival. METHODS: Three hundred and thirty propensity matched patients, who underwent TAVR using Sapien valve (Edwards Lifesciences Corp, Irvine, CA) between February 15, 2012 and June 17, 2016 (115 TA and 115 transfemoral [TF] routes) were studied. The pre- and 1 month post-TAVR echocardiographic features of both groups were compared. The 4-year survival in both groups was analyzed. RESULTS: Baseline clinical characteristics, diastolic function parameters, left ventricular (LV) chamber size, and ejection fraction were similar between matched TA and TF groups. At 1 month following TAVR, there was a significant increase in stroke volume index (SVI) in both TA (mean increase 7 cm3 /m2 ; P = 0.03) and TF groups (mean increase 7 cm3 /m2 ; P < 0.001). Left ventricular ejection fraction (LVEF) significantly increased post TF TAVR (mean increase 2%; P = 0.008), but no significant increase was observed post TA TAVR (mean increase 1%; P = 0.27). Both groups had significant improvement in aortic valve (AV) hemodynamics post-TAVR (P < 0.001). Overall, there were no significant differences in the mean change of SVI, LVEF, or left ventricular end diastolic dimensions (LVEDDs) post TA versus TF TAVR. There was no significant difference in 4-year survival in the TF compared to TA group (49% vs 50%, P = 0.43). CONCLUSION: Both TA and TF TAVR were equally associated with favorable changes in LV SVI and AV hemodynamics in 30 days. TA TAVR patients had similar 4 year survival to propensity matched TF TAVR; therefore, TA TAVR remains an acceptable alternative access route in patients not amenable to TF TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Cateterismo Periférico , Artéria Femoral , Substituição da Valva Aórtica Transcateter , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Hemodinâmica , Humanos , Masculino , Punções , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...