Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Contact Dermatitis ; 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38676576

RESUMO

BACKGROUND: Contrary to Ni2+- and Co2+-induced allergic contact dermatitis (ACD), reactions against Pd2+ are rare. However, Pd2+ activates a larger T cell fraction in vitro, suggesting an inefficient skin penetration. OBJECTIVES: This study compares Ni2+, Co2+ and Pd2+ skin penetration from commonly used diagnostic patch test preparations (PTPs) and aqueous metal salt solutions. METHODS: Using Franz diffusion cell assays, we applied the metals in PTPs (5% NiSO4, 1% CoCl2, 2% PdCl2 and 3% Na2PdCl4) and in solution to pigskin for 48 h, thereby mirroring the time frame of a patch test. The different compartments were analysed individually by inductively coupled plasma mass spectrometry. RESULTS: Metal ions were mainly retained in the upper stratum corneum layers. After application of PTPs, concentrations in the viable skin were lower for Pd2+ (1 and 7 µM) compared to Ni2+ and Co2+ (54 and 17 µM). CONCLUSIONS: Ni2+ and Co2+ penetrated the skin more efficiently than Pd2+ and thus may sensitize and elicit ACD more easily. This was observed for ions applied in petrolatum and aqueous solutions. We hypothesize that the differently charged metal complexes are responsible for the varying skin penetration behaviours.

2.
Nanoscale ; 14(12): 4690-4704, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35262538

RESUMO

We describe the outcome of a large international interlaboratory study of the measurement of particle number concentration of colloidal nanoparticles, project 10 of the technical working area 34, "Nanoparticle Populations" of the Versailles Project on Advanced Materials and Standards (VAMAS). A total of 50 laboratories delivered results for the number concentration of 30 nm gold colloidal nanoparticles measured using particle tracking analysis (PTA), single particle inductively coupled plasma mass spectrometry (spICP-MS), ultraviolet-visible (UV-Vis) light spectroscopy, centrifugal liquid sedimentation (CLS) and small angle X-ray scattering (SAXS). The study provides quantitative data to evaluate the repeatability of these methods and their reproducibility in the measurement of number concentration of model nanoparticle systems following a common measurement protocol. We find that the population-averaging methods of SAXS, CLS and UV-Vis have high measurement repeatability and reproducibility, with between-labs variability of 2.6%, 11% and 1.4% respectively. However, results may be significantly biased for reasons including inaccurate material properties whose values are used to compute the number concentration. Particle-counting method results are less reproducibile than population-averaging methods, with measured between-labs variability of 68% and 46% for PTA and spICP-MS respectively. This study provides the stakeholder community with important comparative data to underpin measurement reproducibility and method validation for number concentration of nanoparticles.

3.
Curr Med Chem ; 29(2): 358-368, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33618638

RESUMO

Compared to the classical chemicals, nanoparticles (NPs) exhibit unique properties, which lead to challenges in sample preparation and analysis. Fractionation techniques and, in particular, hollow fiber flow field flow fractionation (HF5) have recently become popular in the characterization and quantification of nanomaterials, because of their fine fractionation capability in the nanoscale-range. When dealing with NPs, a great drawback during fractionation is the loss of particles in the fractionation devices, tubing and connectors. There is a need for studies to systematically explore and assess the quality of the fractionation process. A combination of two complementary mass-based setups was used to determine particle loss in HF5. Inductively coupled plasma mass spectrometry (ICP-MS) enabled the estimation of recovery rates for NPs after HF5 separation. Reciprocally, laser ablation ICP-MS (LA-ICP-MS) permitted the evaluation of particles retained on the hollow fiber. 15 nm Au-NPs in different concentrations were evaluated in this study and showed a recovery level for Au-NPs of 50 - 65% based on the applied concentrations after a complete HF5 separation run. Detection of sample deposition on the hollow fiber by LA-ICP-MS indicated a sample loss of about 8%. These findings are important for experiments relying on fractionation of low concentrated nanoparticulate samples.


Assuntos
Fracionamento por Campo e Fluxo , Nanopartículas , Humanos , Espectrometria de Massas , Análise Espectral
4.
Int J Mol Sci ; 22(13)2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-34202329

RESUMO

The interactions between pharmaceuticals and nanomaterials and its potentially resulting toxicological effects in living systems are only insufficiently investigated. In this study, two model compounds, acetaminophen, a pharmaceutical, and cerium dioxide, a manufactured nanomaterial, were investigated in combination and individually. Upon inhalation, cerium dioxide nanomaterials were shown to systemically translocate into other organs, such as the liver. Therefore we picked the human liver cell line HuH-7 cells as an in vitro system to investigate liver toxicity. Possible synergistic or antagonistic metabolic changes after co-exposure scenarios were investigated. Toxicological data of the water soluble tetrazolium (WST-1) assay for cell proliferation and genotoxicity assessment using the Comet assay were combined with an untargeted as well as a targeted lipidomics approach. We found an attenuated cytotoxicity and an altered metabolic profile in co-exposure experiments with cerium dioxide, indicating an interaction of both compounds at these endpoints. Single exposure against cerium dioxide showed a genotoxic effect in the Comet assay. Conversely, acetaminophen exhibited no genotoxic effect. Comet assay data do not indicate an enhancement of genotoxicity after co-exposure. The results obtained in this study highlight the advantage of investigating co-exposure scenarios, especially for bioactive substances.


Assuntos
Acetaminofen/efeitos adversos , Cério/efeitos adversos , Fígado/efeitos dos fármacos , Fígado/metabolismo , Nanopartículas , Acetaminofen/administração & dosagem , Transporte Biológico , Linhagem Celular Tumoral , Cério/administração & dosagem , Dano ao DNA/efeitos dos fármacos , Sinergismo Farmacológico , Humanos , Metaboloma , Metabolômica/métodos , Nanopartículas/química , Tamanho da Partícula , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
5.
J Vis Exp ; (163)2020 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-33044444

RESUMO

Metal-containing nanoparticles (NP) can be characterized with inductively coupled plasma mass spectrometers (ICP-MS) in terms of their size and number concentration by using the single-particle mode of the instrument (spICP-MS). The accuracy of measurement depends on the setup, operational conditions of the instrument and specific parameters that are set by the user. The transport efficiency of the ICP-MS is crucial for the quantification of the NP and usually requires a reference material with homogenous size distribution and a known particle number concentration. Currently, NP reference materials are available for only a few metals and in limited sizes. If particles are characterized without a reference standard, the results of both size and particle number may be biased. Therefore, a dual-inlet setup for characterizing nanoparticles with spICP-MS was developed to overcome this problem. This setup is based on a conventional introduction system consisting of a pneumatic nebulizer (PN) for nanoparticle solutions and a microdroplet generator (µDG) for ionic calibration solutions. A new and flexible interface was developed to facilitate the coupling of µDG, PN and the ICP-MS system. The interface consists of available laboratory components and allows for the calibration, nanoparticle (NP) characterization and cleaning of the arrangement, while the ICP-MS instrument is still running. Three independent analysis modes are available for determining particle size and number concentration. Each mode is based on a different calibration principle. While mode I (counting) and mode III (µDG) are known from the literature, mode II (sensitivity), is used to determine the transport efficiency by inorganic ionic standard solutions only. It is independent of NP reference materials. The µDG based inlet system described here guarantees superior analyte sensitivities and, therefore, lower detection limits (LOD). The size dependent LODs achieved are less than 15 nm for all NP (Au, Ag, CeO2) investigated.


Assuntos
Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Calibragem , Nanopartículas Metálicas/química , Nanopartículas/química , Tamanho da Partícula , Reprodutibilidade dos Testes
6.
Materials (Basel) ; 13(6)2020 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-32235788

RESUMO

Nano-carrier systems such as liposomes have promising biomedical applications. Nevertheless, characterization of these complex samples is a challenging analytical task. In this study a coupled hydrodynamic chromatography-single particle-inductively coupled plasma mass spectrometry (HDC-spICP-MS) approach was validated based on the technical specification (TS) 19590:2017 of the international organization for standardization (ISO). The TS has been adapted to the hyphenated setup. The quality criteria (QC), e.g., linearity of the calibration, transport efficiency, were investigated. Furthermore, a cross calibration of the particle size was performed with values from dynamic light scattering (DLS) and transmission electron microscopy (TEM). Due to an additional Y-piece, an online-calibration routine was implemented. This approach allows the calibration of the ICP-MS during the dead time of the chromatography run, to reduce the required time and enhance the robustness of the results. The optimized method was tested with different gold nanoparticle (Au-NP) mixtures to investigate the characterization properties of HDC separations for samples with increasing complexity. Additionally, the technique was successfully applied to simultaneously determine both the hydrodynamic radius and the Au-NP content in liposomes. With the established hyphenated setup, it was possible to distinguish between different subpopulations with various NP loads and different hydrodynamic diameters inside the liposome carriers.

7.
Int J Mol Sci ; 21(4)2020 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-32074956

RESUMO

Aluminum (Al) is extensively used for the production of different consumer products, agents, as well as pharmaceuticals. Studies that demonstrate neurotoxicity and a possible link to Alzheimer's disease trigger concern about potential health risks due to high Al intake. Al in cosmetic products raises the question whether a possible interaction between Al and retinol (vitamin A) and cholecalciferol (vitamin D3) metabolism might exist. Understanding the uptake mechanisms of ionic or elemental Al and Al nanomaterials (Al NMs) in combination with bioactive substances are important for the assessment of possible health risk associated. Therefore, we studied the uptake and distribution of Al oxide (Al2O3) and metallic Al0 NMs in the human keratinocyte cell line HaCaT. Possible alterations of the metabolic pattern upon application of the two Al species together with vitamin A or D3 were investigated. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging and inductively coupled plasma mass spectrometry (ICP-MS) were applied to quantify the cellular uptake of Al NMs.


Assuntos
Óxido de Alumínio/análise , Alumínio/análise , Colecalciferol/farmacologia , Nanoestruturas/química , Vitamina A/farmacologia , Alumínio/química , Alumínio/metabolismo , Óxido de Alumínio/química , Óxido de Alumínio/metabolismo , Linhagem Celular , Membrana Celular/química , Membrana Celular/metabolismo , Humanos , Queratinócitos/citologia , Queratinócitos/efeitos dos fármacos , Queratinócitos/metabolismo , Espectrometria de Massa de Íon Secundário
8.
Anal Chim Acta ; 1099: 16-25, 2020 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-31986273

RESUMO

This study reports on the development of a single-particle (sp) inductively coupled plasma mass spectrometry (ICP-MS) technique suitable for the multi-mode determination of nanoparticle (NP) metal mass fraction and number concentration. The described technique, which is based on a dual inlet system consisting of a pneumatic nebulizer (PN) and a microdroplet generator (MDG), allows for the sequential introduction of ionic metal calibrant solutions and nanoparticle suspensions via all combinations of the two inlets; thus allowing for a combination of three independent modes of analysis. A novel interface, assembled using standard analytical components (a demountable quartz ICP-MS torch, flexible non-conducting silicon tubing and various connectors), was used to interface the dual inlet system to an ICP-MS. The interface provided improved functionality, compared to a previous design. It is now possible to conveniently exchange and introduce standard solutions and samples via all inlet combinations, analyze them, and also wash the sample inlet systems while the whole setup is still connected to an operating ICP-MS. This setup provided seamless and robust operation in a total of three analysis modes, i.e. three ways to independently determine the metal mass fraction and NP number concentration. All three analyses modes could be carried out within a single analytical run lasting approximately 20 min. The unique feature of the described approach is that each analysis mode is based on a different calibration principle, thus constituting an independent way to determine metal mass fractions and nanoparticle number concentrations. Conducting the three independent state-of-the-art analysis, within a single analytical run, improves substantially the validation capabilities of sp-ICP-MS for NP analysis. To assess the technique's analytical performance, Au, Ag and CeO2 nanoparticles were analyzed. The determined average diameters for Au (56.7 ± 1.5 nm), Ag (72.8 ± 3.4 nm) and CeO2 (69.0 ± 6.4 nm) NPs were in close agreement for all three modes of analysis, as well as with the values provided by suppliers' for Au and Ag NPs (56.0 ± 0.5 for Au, 74.6 ± 3.8 nm for Ag). However, the determined average value for CeO2 was much higher than the expected 28.4 ± 10.4 nm, possibly due to NP agglomeration and the inability to detect NPs existing within the lower size range. The determined NP number concentrations, using analysis modes -I and -II, gave recoveries between 91 and 100% for the Au and Ag NP number concentrations. Whereas analysis mode -III showed a recovery of 70-88% for the same materials. Because of the polydispersity, the small size and polyhedral shape of the CeO2 NPs it was not possible to make NP number concentration comparisons for this material.

9.
Sci Rep ; 10(1): 261, 2020 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-31937806

RESUMO

The biomolecular imaging of cell-nanoparticle (NP) interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS) represents an evolving tool in nanotoxicology. In this study we present the three dimensional (3D) distribution of nanomaterials within biomolecular agglomerates using ToF-SIMS imaging. This novel approach was used to model the resistance of human alveolar A549 cells against gold (Au) ion toxicity through intra- and extracellular biomineralization. At low Au concentrations (≤1 mM HAuCl4) 3D-ToF-SIMS imaging reveals a homogenous intracellular distribution of Au-NPs in combination with polydisperse spherical NPs biomineralized in different layers on the cell surface. However, at higher precursor concentrations (≥2 mM) supplemented with biogenic spherical NPs as seeds, cells start to biosynthesize partially embedded long aspect ratio fiber-like Au nanostructures. Most interestingly, A549 cells seem to be able to sense the enhanced Au concentration. They change the chemical composition of the extracellular NP agglomerates from threonine-O-3-phosphate aureate to an arginine-Au(I)-imine. Furthermore they adopt the extracellular mineralization process from spheres to irregular structures to nanoribbons in a dose-dependent manner with increasing Au concentrations. The results achieved regarding size, shape and chemical specificity were cross checked by SEM-EDX and single particle (sp-)ICP-MS. Our findings demonstrate the potential of ToF-SIMS 3D imaging to better understand cell-NP interactions and their impact in nanotoxicology.


Assuntos
Microambiente Celular , Ouro/química , Imageamento Tridimensional/métodos , Nanopartículas Metálicas/química , Células A549 , Proliferação de Células/efeitos dos fármacos , Compostos de Ouro/química , Humanos , Nanopartículas Metálicas/toxicidade , Microscopia Eletrônica de Varredura , Espectrometria de Massa de Íon Secundário
10.
Arch Toxicol ; 91(12): 3991-4007, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28643002

RESUMO

Inhalation is considered a critical uptake route for NMs, demanding for sound toxicity testing using relevant test systems. This study investigates cytotoxicity and genotoxicity in EpiAirway™ 3D human bronchial models using 16 well-characterized NMs, including surface-functionalized 15 nm SiO2 (4 variants), 10 nm ZrO2 (4), and nanosilver (3), ZnO NM-110, TiO2 NM-105, BaSO4 NM-220, and two AlOOH NMs. Cytotoxicity was assessed by LDH and ATP assays and genotoxicity by the alkaline comet assay. For 9 NMs, uptake was investigated using inductively coupled plasma-mass spectrometry (ICP-MS). Most NMs were neither cytotoxic nor genotoxic in vitro. ZnO displayed a dose-dependent genotoxicity between 10 and 25 µg/cm2. Ag.50.citrate was genotoxic at 50 µg/cm2. A marginal but still significant genotoxic response was observed for SiO2.unmodified, SiO2.phosphate and ZrO2.TODS at 50 µg/cm2. For all NMs for which uptake in the 3D models could be assessed, the amount taken up was below 5% of the applied mass doses and was furthermore dose dependent. For in vivo comparison, published in vivo genotoxicity data were used and in addition, at the beginning of this study, two NMs were randomly selected for short-term (5-day) rat inhalation studies with subsequent comet and micronucleus assays in lung and bone marrow cells, respectively, i.e., ZrO2.acrylate and SiO2.amino. Both substances were not genotoxic neither in vivo nor in vitro. EpiAirway™ 3D models appear useful for NM in vitro testing. Using 16 different NMs, this study confirms that genotoxicity is mainly determined by chemical composition of the core material.


Assuntos
Brônquios/efeitos dos fármacos , Nanoestruturas/toxicidade , Dióxido de Silício/toxicidade , Prata/toxicidade , Zircônio/toxicidade , Trifosfato de Adenosina/metabolismo , Administração por Inalação , Animais , Brônquios/citologia , Técnicas de Cultura de Células , Ensaio Cometa , Humanos , L-Lactato Desidrogenase/metabolismo , Masculino , Testes para Micronúcleos , Testes de Mutagenicidade/métodos , Nanoestruturas/química , Ratos Wistar , Dióxido de Silício/química
11.
J Nanobiotechnology ; 14(1): 50, 2016 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-27334629

RESUMO

BACKGROUND: Safety assessment of nanoparticles (NPs) requires techniques that are suitable to quantify tissue and cellular uptake of NPs. The most commonly applied techniques for this purpose are based on inductively coupled plasma mass spectrometry (ICP-MS). Here we apply and compare three different ICP-MS methods to investigate the cellular uptake of TiO2 (diameter 7 or 20 nm, respectively) and Ag (diameter 50 or 75 nm, respectively) NPs into differentiated mouse neuroblastoma cells (Neuro-2a cells). Cells were incubated with different amounts of the NPs. Thereafter they were either directly analyzed by laser ablation ICP-MS (LA-ICP-MS) or were lysed and lysates were analyzed by ICP-MS and by single particle ICP-MS (SP-ICP-MS). RESULTS: All techniques confirmed that smaller particles were taken up to a higher extent when values were converted in an NP number-based dose metric. In contrast to ICP-MS and LA-ICP-MS, this measure is already directly provided through SP-ICP-MS. Analysis of NP size distribution in cell lysates by SP-ICP-MS indicates the formation of NP agglomerates inside cells. LA-ICP-MS imaging shows that some of the 75 nm Ag NPs seemed to be adsorbed onto the cell membranes and were not penetrating into the cells, while most of the 50 nm Ag NPs were internalized. LA-ICP-MS confirms high cell-to-cell variability for NP uptake. CONCLUSIONS: Based on our data we propose to combine different ICP-MS techniques in order to reliably determine the average NP mass and number concentrations, NP sizes and size distribution patterns as well as cell-to-cell variations in NP uptake and intracellular localization.


Assuntos
Nanopartículas/análise , Neurônios/efeitos dos fármacos , Prata/farmacocinética , Titânio/farmacocinética , Animais , Transporte Biológico , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Espectrometria de Massas/métodos , Camundongos , Nanopartículas/toxicidade , Nanopartículas/ultraestrutura , Neurônios/citologia , Neurônios/metabolismo , Prata/análise , Prata/toxicidade , Titânio/análise , Titânio/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...