Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiother Oncol ; 190: 110009, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37972735

RESUMO

BACKGROUND AND PURPOSE: Since 2011, our center has been using a library-based Plan-of-the-Day (PotD) strategy for external beam radiotherapy of cervical cancer patients to reduce normal tissue dose while maintaining adequate target coverage. With the advent of fully online-adaptive techniques such as daily online-adaptive replanning, further dose reduction may be possible. However, it is unknown how this reduction relates to plan library approaches, and how the most recent PotD strategies relate to no adaptation. In this study we compare the performance of our current PotD strategy with non-adaptive and fully online-adaptive techniques in terms of target volume size and normal tissue sparing. MATERIALS AND METHODS: Treatment data of 376 patients treated with the PotD protocol between June 2011 and April 2020 were included. The size of the Planning Target Volumes (PTVs) was reconstructed for different strategies: full online adaptation, no adaptation, and the latest clinical version of the PotD protocol. Normal tissue sparing was estimated by the difference in margin volume to construct the PTV and the volume overlap of the PTV with bladder and rectum. RESULTS: The current version of our PotD approach reduced the PTV margin volume by a median of 250 cm3 compared to no adaptation. Bladder-PTV overlap decreased from a median of 142 to 71 cm3, and from 39 to 16 cm3 for rectum-PTV. Fully online-adaptive approaches could further decrease the PTV volume by 144 cm3 using a 5 mm margin for residual errors. In this scenario, bladder-PTV overlap was reduced to 35 cm3 and rectum-PTV overlap to 11 cm3. CONCLUSION: The current version of the PotD protocol is an effective technique to improve normal tissue sparing compared to no adaptation. Further sparing can be achieved using fully online-adaptive techniques, but at the cost of a more complex workflow and with a potentially limited impact. PotD-type protocols can therefore be considered as a suitable alternative to fully online-adaptive approaches.


Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Órgãos em Risco , Radioterapia Guiada por Imagem/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Bexiga Urinária , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
2.
Radiother Oncol ; 182: 109518, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36736588

RESUMO

BACKGROUND AND PURPOSE: Image-guided adaptive brachytherapy (IGABT) is an important modality in the cervical cancer treatment, and plan quality is sensitive to time pressure in the workflow. Patient anatomy-based quality-assurance (QA) with overlap volume histograms (OVHs) has been demonstrated to detect suboptimal plans (outliers). This analysis quantifies the possible improvement of plans detected as outliers, and investigates its suitability as a clinical QA tool in a multi-center setting. MATERIALS AND METHODS: In previous work OVH-based models were investigated for the use of QA. In this work a total of 160 plans of 68 patients treated in accordance with the current state-of-the-art IGABT protocol from Erasmus MC (EMC) were analyzed, with a model based on 120 plans (60 patients) from UMC Utrecht (UMCU). Machine-learning models were trained to define QA thresholds, and to predict dose D2cm3 to bladder, rectum, sigmoid and small bowel with the help of OVHs of the EMC cohort. Plans out of set thresholds (outliers) were investigated and retrospectively replanned based on predicted D2cm3 values. RESULTS: Analysis of replanned plans demonstrated a median improvement of 0.62 Gy for all Organs At Risk (OARs) combined and an improvement for 96 % of all replanned plans. Outlier status was resolved for 36 % of the replanned plans. The majority of the plans that could not be replanned were reported having implantation complications or insufficient coverage due to tumor geometry. CONCLUSION: OVH-based QA models can detect suboptimal plans, including both unproblematic BT applications and suboptimal planning circumstances in general. OVH-based QA models demonstrate potential for clinical use in terms of performance and user-friendliness, and could be used for knowledge transfer between institutes. Further research is necessary to differentiate between (sub)optimal planning circumstances.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/patologia , Braquiterapia/métodos , Estudos Retrospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/patologia
3.
Radiother Oncol ; 170: 169-175, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35219799

RESUMO

BACKGROUND AND PURPOSE: Image-guided adaptive brachytherapy (IGABT) is a key component in the treatment of cervical cancer, but the nature of the clinical workflow makes it vulnerable to suboptimal plans, as the theoretical optimal plan depends heavily on organ configuration. Patient anatomy-based quality-assurance (QA) with overlap volume histograms (OVHs) is a promising tool to detect such suboptimal plans, and in this analysis its suitability as a multi-institutional clinical QA tool is investigated. MATERIALS AND METHODS: A total of 223 plans of 145 patients treated in accordance with the current state-of-the-art IGABT protocols from UMC Utrecht (UMCU) and Erasmus MC (EMC) were included. Machine-learning models were trained to predict dose D2cm3 to bladder, rectum, sigmoid and small bowel with the help of OVHs. For this strategy, points are sampled on the organs-at-risk (OARs), and the distances of the sampled points to the target are computed and combined in a histogram. Machine-learning models can then be trained to predict dose-volume histograms (DVHs) for unseen data. Single-center model robustness to needle use and applicator type and multi-center model translatability were investigated. Performance of models was assessed by the difference between planned (clinical) and predicted D2cm3 values. RESULTS: Intra-validation of UMCU data demonstrated OVH model robustness to needle use and applicator type. The model trained on UMCU data was found to be robust within the same protocol on EMC data, for all investigated OARs. Mean squared error between planned and predicted D2cm3 values of OARs ranged between 0.13 and 0.40 Gy within the same protocol, indicating model translatability. For the former protocol cohort of Erasmus MC large deviations were found between the planned and predicted D2cm3 values, indicating plan deviation from protocol. Mean squared error for this cohort ranged from 0.84 to 4.71 Gy. CONCLUSION: OVH-based models can provide a solid basis for multi-institutional QA when trained on a sufficiently strict protocol. Further research will quantify the model's impact as a QA tool.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Braquiterapia/métodos , Feminino , Humanos , Aprendizado de Máquina , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias do Colo do Útero/radioterapia
4.
Int J Radiat Oncol Biol Phys ; 109(5): 1580-1587, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33227442

RESUMO

PURPOSE: A method was recently developed for online-adaptive intensity modulated proton therapy (IMPT) in patients with cervical cancer. The advantage of this approach, relying on the use of tight margins, is challenged by the intrafraction target motion. The purpose of this study was to evaluate the dosimetric effect of intrafraction motion on the target owing to changes in bladder filling in patients with cervical cancer treated with online-adaptive IMPT. METHODS AND MATERIALS: In 10 patients selected to have large uterus motion induced by bladder filling, the intrafraction anatomic changes were simulated for several prefraction durations for online (automated) contouring and planning. For each scenario, the coverage of the primary target was evaluated with margins of 2.5 and 5 mm. RESULTS: Using a 5- mm planning target volume margin, median accumulated D98% was greater than 42.75 GyRBE1.1 (95% of the prescribed dose) in the case of a prefraction duration of 5 and 10 minutes. For a prefraction duration of 15 minutes, this parameter deteriorated to 42.6 GyRBE1.1. When margins were reduced to 2.5 mm, only a 5-minute duration resulted in median target D98% above 42.75 GyRBE1.1. In addition, smaller bladders were found to be associated with larger dose degradations compared with larger bladders. CONCLUSIONS: This study indicates that intrafraction anatomic changes can have a substantial dosimetric effect on target coverage in an online-adaptive IMPT scenario for patients subject to large uterus motion. A margin of 5 mm was sufficient to compensate for the intrafraction motion due to bladder filling for up to 10 minutes of prefraction time. However, compensation for the uncertainties that were disregarded in this study, by using margins or robust optimization, is also required. Furthermore, a large bladder volume restrains intrafraction target motion and is recommended for treating patients in this scenario. Assuming that online-adaptive IMPT remains beneficial as long as narrow margins are used (5 mm or below), this study demonstrates its feasibility with regard to intrafraction motion.


Assuntos
Movimentos dos Órgãos , Terapia com Prótons/métodos , Radioterapia de Intensidade Modulada/métodos , Bexiga Urinária/anatomia & histologia , Neoplasias do Colo do Útero/radioterapia , Útero , Tomografia Computadorizada de Feixe Cônico , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Feminino , Humanos , Tamanho do Órgão , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Bexiga Urinária/diagnóstico por imagem , Neoplasias do Colo do Útero/diagnóstico por imagem , Útero/diagnóstico por imagem
5.
Radiother Oncol ; 148: 38-43, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32311599

RESUMO

BACKGROUND AND PURPOSE: To investigate relationships between patient-reported acute gastro-intestinal symptoms in a locally advanced cervical cancer (LACC) prospective cohort and clinical and dosimetric parameters, while also taking spatial dose into account. MATERIAL AND METHODS: A total of 103 patients was included, receiving radiotherapy based on a plan-library-based plan-of-the-day protocol, combined either with concurrent chemotherapy or with neo-adjuvant chemotherapy and concomitant hyperthermia. Toxicity endpoints were extracted from questionnaires sent out weekly during treatment and regularly in the acute phase after treatment. Endpoints were defined for symptoms concerning obstipation, diarrhea, fecal leakage, bowel cramps and rectal bleeding. Dose surface maps were constructed for the rectum. Clinical parameters and dosimetric parameters of the bowel bag and rectum were collected for all patients. RESULTS: The use of concomitant chemotherapy and an increase in Planning Target Volume (PTV) resulted in a significant increase in reported diarrhea. The dose-volume parameters V5Gy-V25Gy of the rectum were found to be significant, unlike dose-volume parameters of the bowel bag. Additionally, a significantly higher dose to the inferior part of the rectum was found for patients reporting diarrhea. No significance was reached for fecal leakage and bowel cramps. CONCLUSION: The significance of results for patients reporting diarrhea symptoms found for PTV volume indicates a potential benefit for a plan-of-the-day protocol. Additionally, the results suggest that a reduction of inferior rectum dose could decrease patient-reported diarrhea symptoms, while the administration of concomitant chemotherapy appears to lead to radiosensitizing effects that increase these symptoms.


Assuntos
Reto , Neoplasias do Colo do Útero , Feminino , Humanos , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Neoplasias do Colo do Útero/radioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...