Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 198(9-11): 641-645, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36005962

RESUMO

Optically stimulated luminescence of quartz extracted from fired materials has been used for retrospective dosimetry for about 40 years. Quartz sensitivity to thermoluminescence and optically stimulated luminescence can vary over few orders of magnitude. These discrepancies in sensitivity for the quartz originating from different parts of the world are still not yet fully understood. We have extracted quartz from bricks produced by three different companies in the Czech Republic. Quartz was extracted from fired bricks, as well as from the bricks before firing. Significant changes in quartz sensitivity were observed after firing process. Sensitivity can either increase or decrease, depending mainly on the maximum temperature achieved during firing process. For some samples, the sensitivity increased significantly after firing (7 times). Sensitivity also increased after repeated irradiation exposures. On the other hand, there were also samples for which the sensitivity did not increase after repeated cycles of irradiation.


Assuntos
Quartzo , Dosimetria Termoluminescente , Materiais de Construção , Quartzo/efeitos da radiação , Radiometria , Estudos Retrospectivos
2.
Front Public Health ; 10: 908016, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35784234

RESUMO

Several common pharmaceuticals such as ibuprofen, paracetamol, aspirin, oral contraceptives, drugs for the prevention of motion sickness and food supplements such as table vitamins and minerals have been studied for the purposes of retrospective dosimetry using optically stimulated luminescence (OSL). The essence is that the tablets with these drug substances contain additive crystalline materials which, after irradiation and stimulation, may exhibit luminescence. For most of the pharmaceuticals and food supplements, a radiation-induced dose-dependent OSL signal was detected. Subsequently, basic dosimetric characteristics of the materials were studied, specifically sensitivity changes during repeated OSL readings, dose response, zero-dose, minimum detectable dose (MDD) and fading. The most radiation sensitive materials were food supplements with Mg providing zero-dose and MDD values at the level of several mGy. For Mg supplements, considerable sensitivity changes in OSL signal were observed. Despite this, they could be corrected using a Single-Aliquot Regenerative-dose (SAR) protocol. The OSL signals of the other materials were relatively weak but they were well reproducible and exhibited linear dose response. The MDD values were variable among the materials and ranged from 0.1 to several Gy. However, for some of the pharmaceuticals, a very high and variable zero-dose of more than 3 Gy was observed that would rule out the possibility of dose reconstruction for triage purposes. The OSL signal exhibited a significant fading rate for most of the materials. The measurements for dose reconstruction should be performed as soon as possible after irradiation, i.e. within a maximum of a few days.


Assuntos
Dosimetria por Luminescência Estimulada Opticamente , Suplementos Nutricionais , Dosimetria por Luminescência Estimulada Opticamente/métodos , Preparações Farmacêuticas , Doses de Radiação , Estudos Retrospectivos
3.
Int J Radiat Biol ; 98(5): 890-899, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34606411

RESUMO

PURPOSE: The threat of serious radiation exposures to members of the public from radiological incidents and nuclear events has led to intensive study of a number of emergency dosimetry techniques for purposes of triage. As such, a national laboratory of retrospective dosimetry was established in our institute. The purpose of this work is to provide a summary of the well-established and already implemented retrospective physical dosimetry techniques based on thermoluminescence (TL), optically stimulated luminescence (OSL) and neutron activation including their specifics. Moreover, we present some new results of the experimental work, in which we compared dosimetry potential of various dental repair materials and human teeth. MATERIALS AND METHODS: At first, an overview of already established retrospective physical retrospective methods including their main features was compiled. As regards recent research, an experimental comparative study was performed under defined conditions. The materials used were aliquots prepared from both pure and repaired teeth and aliquots of unused dental ceramics of known type. Following irradiation, we compared TL and OSL curves of the materials. We also compared dosimetry characteristics of OSL signal as reproducibility, dose dependence and fading. RESULTS: After irradiation, the teeth aliquots of dental enamel and dentin exhibited very low OSL and TL signals compared with aliquots containing some dental repair materials or aliquots of pure dental ceramics. With a few exceptions, the OSL signal of dental enamel and dentin aliquots irradiated to 2 Gy was hardly distinguishable from OSL signal corresponding to unirradiated aliquots. In contrast, aliquots of teeth containing some dental repair material and aliquots of pure dental ceramics provided a well reproducible OSL signal exhibiting linear dose response. All the materials tested exhibited a significant fading of the OSL signal. The loss of OSL signal during the first 24 hours after irradiation was from 20 to 99% of its original value obtained immediately after the irradiation. CONCLUSIONS: The already established physical methods of retrospective dosimetry use a spectrum of verified materials and techniques for dose assessment in the aftermath of serious radiological incidents and nuclear events. In the comparative study, we found that the dosimetry potential of teeth in natural state is much worse compared to teeth repaired with dental ceramics or dental cement fillings. Teeth restored with dental repair materials exhibited relatively favorable dosimetry characteristics. However, they can be usable for a dose reconstruction only on condition that the main practical problems connected with fading and optical bleaching were solved.


Assuntos
Luminescência , Radiometria , República Tcheca , Humanos , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Dosimetria Termoluminescente
4.
Appl Radiat Isot ; 178: 109947, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34536830

RESUMO

In the aftermath of an orphan radiation source find, a complex retrospective dose reconstruction can be required to estimate doses of persons who were staying in the vicinity. In retrospective dose reconstructions based on luminescence measurements of quartz extracted from bricks, high sensitivity thermoluminescence detectors (TLD) can be used as an ancillary tool for dose distribution measurements or natural radiation background measurement. We investigated the potential and limits of Al2O3:C, CaF2:Mn and LiF:Mg,Cu,P detectors for such applications. We measured depth-dose profiles in bricks using quartz and the TLDs. We factored in important dosimetry characteristics such as dose response, energy response and detection threshold. The work included Monte Carlo simulations. Depth-dose profiles and radiation spectra inside of the bricks were calculated for purposes of comparison and interpretation. The measurements and calculations were performed for two different photon spectra with mean energies of 662 and 118 keV. As regards comparison of the measured and Monte Carlo calculated depth-dose profiles, the best agreement was found for LiF:Mg,Cu,P. Quartz, Al2O3:C and CaF2:Mn tend to overestimate dose for lower photon energies and greater depths in bricks. The overestimation was the most marked for CaF2:Mn. For measurements related to quartz, especially for natural radiation background dose measurement, the most suitable TLDs are Al2O3:C and LiF:Mg,Cu,P. CaF2:Mn is the least useful material.

5.
Nanoscale ; 13(25): 11197-11203, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34142687

RESUMO

We report experimental results on damage induced by ionizing radiation to DNA origami triangles which are commonly used prototypes for scaffolded DNA origami nanostructures. We demonstrate extreme stability of DNA origami upon irradiation, which is caused by (i) the multi-row design holding the shape of the origami even after severe damage to the scaffold DNA and (ii) the reduction of damage to the scaffold DNA due to the protective effect of the folded structure. With respect to damage induced by ionizing radiation, the protective effect of the structure is superior to that of a naturally paired DNA double helix. Present results allow estimating the stability of scaffolded DNA origami nanostructures in applications such as nanotechnology, pharmacy or in singulo molecular studies where they are exposed to ionizing radiation from natural and artificial sources. Additionally, possibilities are opened for scaffolded DNA use in the design of radiation-resistant and radio-sensitive materials.


Assuntos
Nanoestruturas , DNA , Nanotecnologia , Conformação de Ácido Nucleico , Radiação Ionizante
6.
Int J Radiat Biol ; 94(12): 1142-1150, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30451562

RESUMO

PURPOSE: The purpose of the paper was to investigate the protective effect of some scavengers of OH radicals (hydroxyl radicals) on the radiation sensitivity of bacteria (in some cases also yeast) under normoxic (in air) or hypoxic (suboxic) conditions and to compare the obtained results with those published earlier for the yeast, all in a wide interval of irradiation conditions. Another aim was to investigate a possible impact of the reaction order of the reaction between the scavengers and the OH radicals on the protection of the cells. MATERIALS AND METHODS: In order to study the protective effect of OH scavengers we used various concentrations of methanol and potassium formate (in some cases also ethanol) in isotonic salt solutions. These solutions containing living bacteria (Escherichia coli) or yeast (Saccharomyces cerevisiae) were irradiated with 60Co radiation using various doses and dose rates. Irradiation was performed in air, in some cases under the hypoxic conditions. The number of surviving cells was determined prior to and after irradiation in suspension with and without scavengers. The surviving fractions after irradiation with and without scavenger were evaluated. RESULTS: The surviving fraction of bacterial cells increases linearly with increasing concentration of both scavengers. The fraction of surviving cells does not increase with increasing concentration of the scavengers under suboxic conditions. The protective effect Ϭ increases linearly with increasing scavenging efficiency and this dependence is much sharper under normoxic conditions than under suboxic ones. The specific protection k is much higher for the methanol than for the potassium formate. CONCLUSIONS: The basic characteristics of the impact of scavengers of OH radicals on radiation sensitivity of both bacteria and yeast are the same in a wide interval of doses and dose rates. The specific protection effect is much higher under the normoxic conditions. This protective effect is inversely proportional to the rate constant of the reaction between the scavenger and the OH radicals. It seems to be obvious that the presence of oxygen during irradiation is a necessary condition for the protective action of the scavengers which may be partially controlled by some transport processes and may be connected with the radiation sensitivity of the cells. On the other hand, the change of the reaction order of the reaction of the scavenger with the OH radicals has turned out to be unimportant.


Assuntos
Escherichia coli/efeitos dos fármacos , Escherichia coli/efeitos da radiação , Sequestradores de Radicais Livres/metabolismo , Sequestradores de Radicais Livres/farmacologia , Radical Hidroxila/metabolismo , Tolerância a Radiação/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Relação Dose-Resposta a Droga , Escherichia coli/citologia , Escherichia coli/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...