Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Cancer ; 4(4): 485-501, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36997747

RESUMO

To enhance the therapeutic index of T-cell engagers (TCEs), we engineered masked, precision-activated TCEs (XPAT proteins), targeting a tumor antigen (human epidermal growth factor receptor 2 (HER2) or epidermal growth factor receptor (EGFR)) and CD3. Unstructured XTEN polypeptide masks flank the N and C termini of the TCE and are designed to be released by proteases in the tumor microenvironment. In vitro, unmasked HER2-XPAT (uTCE) demonstrates potent cytotoxicity, with XTEN polypeptide masking providing up to 4-log-fold protection. In vivo, HER2-XPAT protein induces protease-dependent antitumor activity and is proteolytically stable in healthy tissues. In non-human primates, HER2-XPAT protein demonstrates a strong safety margin (>400-fold increase in tolerated maximum concentration versus uTCE). HER2-XPAT protein cleavage is low and similar in plasma samples from healthy and diseased humans and non-human primates, supporting translatability of stability to patients. EGFR-XPAT protein confirmed the utility of XPAT technology for tumor targets more widely expressed in healthy tissues.


Assuntos
Neoplasias , Linfócitos T , Animais , Humanos , Antígenos de Neoplasias/metabolismo , Receptores ErbB , Imunoterapia/efeitos adversos , Neoplasias/tratamento farmacológico , Microambiente Tumoral , Complexo CD3/metabolismo
2.
PLoS One ; 14(4): e0213452, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30943212

RESUMO

Bone marrow stromal cells (BMSCs) include a subset of stem cells that are considered promising for developmental studies and therapeutic applications. While it is appreciated generally that BMSC populations can exhibit morphological and functional heterogeneity upon in vitro culture expansion, the potential for heterogeneity within a single colony forming unit-generated ostensibly from a single mother cell-is less explored but is critical to design of both fundamental studies and cell therapy production. Here we observed BMSC colony formation in real time via time lapsed optical imaging and analysis, to quantify whether and how heterogeneity emerged over multiple cell divisions spanning the duration of a typical colony formation unit assay. These analyses demonstrate that such colonies are neither homogeneous subpopulations of stem cells nor necessarily derived from single originating cells. While the mechanisms for and causes of this intracolony heterogeneity are not understood fully, we further demonstrate that extensive cell-cell contacts do not correlate with senescence, but that media exchange was concurrent with diversification in even the most uniform single-cell-derived colonies. These direct quantitative observations and visualizations of colony formation provide new insights that are motivated by significant implications for both basic research and stem cell-based therapies.


Assuntos
Células da Medula Óssea/fisiologia , Divisão Celular/fisiologia , Microscopia Intravital , Células-Tronco Mesenquimais/fisiologia , Células Cultivadas , Ensaio de Unidades Formadoras de Colônias , Humanos , Análise de Célula Única , Imagem com Lapso de Tempo
3.
J Tissue Eng Regen Med ; 11(1): 121-128, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-24700577

RESUMO

Recently, biomaterials-based tissue-engineering strategies, including the use of hydrogels, have offered great promise for repairing articular cartilage. Mechanical failure testing in outcome analyses is of crucial clinical importance to the success of engineered constructs. Interpenetrating networks (IPNs) are gaining more attention, due to their superior mechanical integrity. This study provided a combination testing method of apparent fracture toughness, which was applied to both articular cartilage and hydrogels. The apparent fracture toughnesses of two groups, hydrogels and articular cartilage, were evaluated based on the modified single-edge notch test and ASTM standards on the single-edge notch test and compact tension test. The results demonstrated that the toughness for articular cartilage (348 ± 43 MPa/mm½ ) was much higher than that for hydrogels. With a toughness value of 10.8 ± 1.4 MPa/mm½ , IPNs of agarose and poly(ethylene glycol) diacrylate (PEG-DA) looked promising. The IPNs were 1.4 times tougher than PEG-DA alone, although still over an order of magnitude less tough than cartilage. A new method was developed to evaluate hydrogels and cartilage in a manner that enabled a more relevant direct comparison for fracture testing of hydrogels for cartilage tissue engineering. Moreover, a target toughness value for cartilage of using this direct comparison method has been identified (348 ± 43 MPa/mm½ ), and the toughness discrepancy to be overcome between hydrogels and cartilage has been quantified. Copyright © 2014 John Wiley & Sons, Ltd.


Assuntos
Materiais Biocompatíveis/química , Cartilagem Articular/patologia , Polietilenoglicóis/química , Engenharia Tecidual/métodos , Animais , Sobrevivência Celular , Condrócitos , Hidrogéis/química , Masculino , Teste de Materiais , Sefarose/química , Suínos , Resistência à Tração
4.
Stem Cells ; 34(5): 1135-41, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26840390

RESUMO

The emergence of heterogeneity in putative mesenchymal stem cell (MSC) populations during in vitro expansion is not appreciated fully by the various communities who study, engineer, and use such stem cells. However, this functional diversity holds direct implications for basic research and therapeutic applications of MSCs that require predictable phenotypic function and efficacy. Despite numerous clinical trials pursuing MSC therapies, the in vitro expansion of homogeneous populations to therapeutically relevant quantities remains an elusive goal. Variation in MSC cultures has been noted not only among donors and within populations expanded from the same donor, but also debatably within single-cell-derived colonies. The potential for even intracolony heterogeneity suggests that any purified subpopulation will inevitably become heterogeneous upon further expansion under current culture conditions. Here, we review the noted or retrospective evidence of intracolony MSC heterogeneity, to facilitate discussion of its possible causes and potential solutions to its mitigation. This analysis suggests that functional diversity within an MSC colony must be considered in design of experiments and trials for even nonclonal stem cell populations, and can be mitigated or even exploited when the mechanisms of onset are better understood. Stem Cells 2016;34:1135-1141.


Assuntos
Ensaio de Unidades Formadoras de Colônias , Células-Tronco Mesenquimais/citologia , Animais , Células Clonais/citologia , Humanos
5.
Biomaterials ; 34(33): 8241-57, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23932504

RESUMO

Hydrogels are attractive for tissue engineering applications due to their incredible versatility, but they can be limited in cartilage tissue engineering applications due to inadequate mechanical performance. In an effort to address this limitation, our team previously reported the drastic improvement in the mechanical performance of interpenetrating networks (IPNs) of poly(ethylene glycol) diacrylate (PEG-DA) and agarose relative to pure PEG-DA and agarose networks. The goal of the current study was specifically to determine the relative importance of PEG-DA concentration, agarose concentration, and PEG-DA molecular weight in controlling mechanical performance, swelling characteristics, and network parameters. IPNs consistently had compressive and shear moduli greater than the additive sum of either single network when compared to pure PEG-DA gels with a similar PEG-DA content. IPNs withstood a maximum stress of up to 4.0 MPa in unconfined compression, with increased PEG-DA molecular weight being the greatest contributing factor to improved failure properties. However, aside from failure properties, PEG-DA concentration was the most influential factor for the large majority of properties. Increasing the agarose and PEG-DA concentrations as well as the PEG-DA molecular weight of agarose/PEG-DA IPNs and pure PEG-DA gels improved moduli and maximum stresses by as much as an order of magnitude or greater compared to pure PEG-DA gels in our previous studies. Although the viability of encapsulated chondrocytes was not significantly affected by IPN formulation, glycosaminoglycan (GAG) content was significantly influenced, with a 12-fold increase over a three-week period in gels with a lower PEG-DA concentration. These results suggest that mechanical performance of IPNs may be tuned with partial but not complete independence from biological performance of encapsulated cells.


Assuntos
Hidrogéis/química , Polietilenoglicóis/química , Sefarose/química , Engenharia Tecidual/métodos , Animais , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Condrócitos/citologia , Condrócitos/efeitos dos fármacos , Feminino , Glicosaminoglicanos/química , Hidrogéis/farmacologia , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...