Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Abdom Radiol (NY) ; 49(4): 1007-1019, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38329482

RESUMO

Obesity is a worldwide health concern leading to several chronic health problems and comorbidities. Its treatment requires a multidisciplinary approach where lifestyle changes are fundamental. Additionally, in the past decade, the use of different surgical procedures of various levels of complexity has grown, with the objective of reducing the gastric capacity, creating diversions, or a combination of both. The aim of this article is to review and illustrate the major types of bariatric surgical techniques, their normal post-surgical anatomy, and the possible associated complications, to aid the radiologist in their assessment and timely diagnosis.


Assuntos
Cirurgia Bariátrica , Obesidade , Humanos , Cirurgia Bariátrica/métodos , Estômago , Comorbidade , Radiologistas
2.
Can Assoc Radiol J ; 74(4): 695-704, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37011899

RESUMO

Purpose: The aim was to reduce outpatient wait time and improve patient experience by optimising oral contrast use. Methods: Our multidisciplinary stakeholder collaboration implemented two simultaneous interventions: (1) Creation of 'oral contrast policy', limiting recommended indications. (2) Creation of a new shorter oral contrast regime (30 vs 60 min). We conducted a retrospective service evaluation of oral contrast use in outpatient (OP) abdominal CT at baseline and post-intervention. Patient wait times were measured and per-patient cost-savings were reported. An image quality review was performed by 2 blinded abdominal radiologists. Patient experience was evaluated with a standard voluntary survey. Statistical analysis was performed comparing baseline and evaluation outcomes using Chi-square or Fisher Exact test for categorical variables and Student's t-test or ANOVA for continuous data. Results: Over 1-month periods, OP CT scans were assessed in baseline (pre-pandemic) n = 575, baseline (pandemic) n = 495 and post-intervention n = 545 groups. Oral contrast use reduced from 420/575, 73.0% at baseline to 178/545, 32.7% post intervention. The turn-around time reduced by 15.8 minutes per patient from 70.3 to 54.5 minutes, P < .001 (Interventions 1 and 2). The diagnostic quality did not differ between the oral contrast regimes (Intervention 2, P = 1.0, P = .08). No repeat CTs were needed due to lack of oral contrast (Intervention 1) or poor opacification (Intervention 2). There was oral contrast cost reductions of 69.1-78.4% (P < .001). Patients reported their overall experience was improved post-intervention (Interventions 1 and 2). Conclusions: Optimising the CT oral contrast service through judicious use and a shorter regime, reduced patient wait times, improved patient experience and preserved diagnostic quality.


Assuntos
Pacientes Ambulatoriais , Radiologia , Humanos , Estudos Retrospectivos , Salas de Espera , Pandemias , Tomografia Computadorizada por Raios X/métodos , Avaliação de Resultados da Assistência ao Paciente
4.
Vasc Endovascular Surg ; 54(2): 141-146, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31749415

RESUMO

OBJECTIVES: To compare outcomes in patients randomized to infrapopliteal (IP) plain balloon angioplasty (PBA) for chronic limb-threatening ischemia within the Bypass versus Angioplasty in Severe Ischemia of the Leg (BASIL)-1 trial between 1999 and 2004 with outcomes in consecutive patients undergoing IP PBA at an academic vascular unit a decade later (2009-2013, Contemporary series [CS]). METHODS: Individual patient data were obtained from prospective BASIL-1 (48 patients) and CS databases (73 patients). All had a minimum of 3-years of follow-up. Outcomes studied were amputation-free survival (AFS), overall survival (OS), major (above ankle) limb amputation, arterial reintervention, immediate technical success, and length of hospital stay for the index procedure and during the following 12-month period. Statistical analysis was performed using SAS version 9.4. RESULTS: The BASIL and CS cohorts were well matched for gender, age, diabetes, previous stroke, myocardial infarction and arterial intervention, and presence of tissue loss. More patients in BASIL-1 underwent concomitant treatment of the superficial femoral (60% vs 37%, P = .01) and above knee popliteal (60% vs 34%, P = .005) arteries. Immediate technical success increased from 73% in BASIL-1 to 90% in the CS (P = .01). Between the two cohorts, there were no differences in AFS (hazard ratio [HR] = 1.00, 95% confidence interval [CI]: 0.65-1.54, P = 1.0), OS (HR = 1.04, 95% CI: 0.66-1.62, P = .9), major amputation (HR = 0.86, 95% CI: 0.37-1.97, P = .7), or reintervention (HR = 0.61, 95% CI: 0.29-1.27, P = .2). Contemporary series patients spent significantly fewer days in hospital following the index procedure (P = .02) and also over the following 12 months (P = .002). CONCLUSIONS: Despite improvements in the immediate technical angiographic success of IP PBA between BASIL and the CS, there were no significant improvements in survival outcomes. Results from BASIL-2 and BEST-CLI are required in order to properly define the clinical and cost-effectiveness of endovascular treatment in such patients.


Assuntos
Angioplastia com Balão , Isquemia/terapia , Doença Arterial Periférica/terapia , Artéria Poplítea , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Doença Crônica , Bases de Dados Factuais , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Tempo de Internação , Masculino , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Intervalo Livre de Progressão , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Grau de Desobstrução Vascular
5.
Artigo em Inglês | MEDLINE | ID: mdl-29445272

RESUMO

Background: The aim of the study was to assess the relationship between computed tomography (CT) densitometry and routine clinical markers in patients with chronic obstructive pulmonary disease (COPD) and alpha-1 anti-trypsin deficiency (AATD). Methods: Multiple databases were searched using a combination of pertinent terms and those articles relating quantitatively measured CT densitometry to clinical outcomes. Studies that used visual scoring only were excluded, as were those measured in expiration only. A thorough review of abstracts and full manuscripts was conducted by 2 reviewers; data extraction and assessment of bias was conducted by 1 reviewer and the 4 reviewers independently assessed for quality. Pooled correlation coefficients were calculated, and heterogeneity was explored. Results: A total of 112 studies were identified, 82 being suitable for meta-analysis. The most commonly used density threshold was -950 HU, and a significant association between CT density and all included clinical parameters was demonstrated. There was marked heterogeneity between studies secondary to large variety of disease severity within commonly included cohorts and differences in CT acquisition parameters. Conclusion: CT density shows a good relationship to clinically relevant parameters; however, study heterogeneity and lack of longitudinal data mean that it is difficult to compare studies or derive a minimal clinically important difference. We recommend that international consensus is reached to standardize CT conduct and analysis in future COPD and AATD studies.


Assuntos
Pulmão/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Deficiência de alfa 1-Antitripsina/complicações , Idoso , Distribuição de Qui-Quadrado , Densitometria , Feminino , Volume Expiratório Forçado , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Capacidade de Difusão Pulmonar , Doença Pulmonar Obstrutiva Crônica/etiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/terapia , Enfisema Pulmonar/etiologia , Enfisema Pulmonar/fisiopatologia , Enfisema Pulmonar/terapia , Qualidade de Vida , Índice de Gravidade de Doença , Espirometria , Capacidade Vital , Deficiência de alfa 1-Antitripsina/diagnóstico , Deficiência de alfa 1-Antitripsina/terapia
6.
Br J Radiol ; 89(1068): 20160311, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27653990

RESUMO

OBJECTIVE: Hypertension is the leading attributable cause of cardiovascular mortality worldwide. Patients with hypertension have multiple comorbidities including high rates of concomitant renal disease. Current pharmacological approaches are inadequate in the treatment of resistant hypertension. Renal sympathetic denervation (RDN) has been shown to effectively treat resistant hypertension. The traditional use of iodinated contrast in RDN is contraindicated in patients with significant renal insufficiency. In patients with renal impairment, carbon dioxide (CO2) can be used as an alternative contrast material for RDN. This article describes the technical aspects of RDN using CO2 angiography. METHODS: Our centre is experienced in the innovative RDN procedure using CO2 angiography. We describe the protocol for CO2 angiography for RDN using a home-made CO2 delivery system and the Symplicity™ (Minneapolis MN 55432 USA) catheter (Medtronic) device. RESULTS: CO2 angiography is an excellent alternative to iodinated contrast for RDN procedures. CONCLUSION: CO2 angiography for RDN is a safe and effective alternative to iodinated contrast. RDN using CO2 angiography is an easy and feasible procedure that can be used in patients with renal insufficiency or iodinated contrast allergies. Advances in knowledge: There is a paucity of descriptive reports for CO2 angiography for RDN and we provide details of the optimal protocol for the procedure. In particular, we describe the use of a Symplicity Spyral™ catheter (Medtronic), which has not been reported to date for use in this procedure.


Assuntos
Angiografia/métodos , Dióxido de Carbono , Meios de Contraste , Aumento da Imagem/métodos , Radiografia Intervencionista/métodos , Simpatectomia , Humanos , Rim
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...