Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Neurol ; 27(7): 1343-1349, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32250518

RESUMO

BACKGROUND AND PURPOSE: The purpose was to investigate our centre's experience on computed-tomography-guided (CT-guided), transforaminal, intrathecal administration of nusinersen in adult subjects with spinal muscular atrophy (SMA) type 2 and severe spinal deformity. METHOD: This is a retrospective, single-centre study investigating the feasibility and safety of CT-guided, transforaminal, lumbar puncture for the intrathecal administration of nusinersen (Spinranza®; Biogen; Cambridge, MA, USA) in a cohort of adult subjects with SMA type 2, severe neuromuscular scoliosis and previous spinal surgery. Between January 2019 and October 2019, five male, adult, SMA type 2 subjects were eligible to be treated in our centre with nusinersen. The mean age of the patients was 31 ± 9 years (range 19-43 years). The study's outcome measures were technical success, adverse events and radiation exposure. RESULTS: In total, four patients completed the four loading doses, whilst the fifth patient received only one loading dose; two patients also received their first maintenance doses. Overall, 20 consecutive transforaminal, intrathecal treatments were analysed. Technical success was 100% (20/20 intrathecal infusions). No adverse events were documented following the procedures. Mean dose-length product (DLP) value per injection was 665.4 ± 715.5 mGy*cm. Estimated mean effective dose per injection was 12.7 ± 12.9 mSv. Subgroup analysis between the chronologically first 10 versus subsequent 10 procedures demonstrated a clear trend towards less radiation exposure in the latter, although this difference did not reach statistical significance (DLP: 984.7 ± 903.3 vs. 436.7 ± 321.5 mGy*cm, P = 0.165; respectively). CONCLUSIONS: In this retrospective series, CT-guided transforaminal access for intrathecal injection of nusinersen was proven feasible and safe. A decrease in radiation dose over time was noted. Protocols to minimize radiation exposure are essential.


Assuntos
Exposição à Radiação , Atrofias Musculares Espinais da Infância , Adulto , Estudos de Viabilidade , Humanos , Injeções Espinhais , Masculino , Oligonucleotídeos , Estudos Retrospectivos , Atrofias Musculares Espinais da Infância/tratamento farmacológico , Tomografia Computadorizada por Raios X , Adulto Jovem
2.
Cardiovasc Intervent Radiol ; 39(10): 1499-505, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27230513

RESUMO

PURPOSE: To report our experience with the use of a battery-powered drill in biopsy and radiofrequency ablation of osteoid osteoma with excess reactive new bone formation. The battery-powered drill enables obtaining the sample while drilling. MATERIALS AND METHODS: During the last 18 months, 14 patients suffering from painful osteoid osteoma with excess reactive new bone formation underwent CT-guided biopsy and radiofrequency ablation. In order to assess and sample the nidus of the osteoid osteoma, a battery-powered drill was used. Biopsy was performed in all cases. Then, coaxially, a radiofrequency electrode was inserted and ablation was performed with osteoid osteoma protocol. Procedure time (i.e., drilling including local anesthesia), amount of scans, technical and clinical success, and the results of biopsy are reported. RESULTS: Access to the nidus through the excess reactive new bone formation was feasible in all cases. Median procedure time was 50.5 min. Histologic verification of osteoid osteoma was performed in all cases. Radiofrequency electrode was coaxially inserted within the nidus and ablation was successfully performed in all lesions. Median amount CT scans, performed to control correct positioning of the drill and precise electrode placement within the nidus was 11. There were no complications or material failure reported in our study. CONCLUSIONS: The use of battery-powered drill facilitates access to the osteoid osteoma nidus in cases where excess reactive new bone formation is present. Biopsy needle can be used for channel creation during the access offering at the same time the possibility to extract bone samples.


Assuntos
Neoplasias Ósseas/patologia , Neoplasias Ósseas/cirurgia , Ablação por Cateter/instrumentação , Biópsia Guiada por Imagem/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Osteogênese , Osteoma Osteoide/patologia , Osteoma Osteoide/cirurgia , Cirurgia Assistida por Computador/instrumentação , Instrumentos Cirúrgicos , Tomografia Computadorizada por Raios X/instrumentação , Adolescente , Adulto , Feminino , Humanos , Masculino , Duração da Cirurgia , Osteogênese/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...